Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹5.2 L+₹41,175 (8.58%)Rejected-Finance 0 SALEHPUR KOTLA BSR ROAD PO DAHANA HAPUR HAPUR UTTAR PRADESH 245101 | HAPUR | UTTAR PRADESH | 245101 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹6.1 L+₹1.3 L (27.5%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹5.3 L
EMD Value
₹10,600
Closing Date
16 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BKT
GE (AF) BKT, LUCKNOW
PROVN OF CERTAIN MINOR WORKS (PHASE-IV) AT AF STN BKT
2023_MES_581520_1
8655/BKT/E
Open Tender
Civil Works
Item Rate
120 days
GE (AF) BKT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) BKT
₹10,600
Yes
10 Apr 2023
17 Feb 2023
18 Mar 2023
17 Feb 2023
16 Mar 2023
2 Mar 2023
Amount
Dismantling of PQC slab including concrete upto depth of 1.00 m by mechanical machine without disturbance of existing adjacent surfaces to avoid any cracks on other connected concrete surfaces, including removal of debris from site to a distance n.exc 500m complete all as specified and directed.
Fixing/grouting of mooring rings at site all as specified and directed by Engr-in-Charge Note :- Mooring rings will be issued by the Users )
M&L for cement concrete (1:2:4) type B2 using (40mm graded stone aggregate) as in foundation filling and mass concrete as in sub base of floors complete all as specified and directed.
M&L for 290 mm thick pavement quality concrete (PQC) as per design mix using crushed stone aggregate having minimum field flexural strength of 45 Kg/Sq cm with and including non circular/triangular synthetic fibre as per manufacturer’s instructions @0.25 % by weight of cement ( minimum cement content shall be 400 Kg / cum using OPC) laid to level, gradient and camber, spread. paved and compacted including necessary form work complete all as specified and directed. Note: (i) In the event of increase in cement content as per design mix formula, nothing extra shall be admissible and quoted rates are deemed to include for the same. (ii) Non-circular synthetic fibres shall be measured and paid separately as supply only under respective item of BOQ.Design mix to be prepared after incorporating fibre.
Supply only non circular synthetic fibres of length 12 mm, designed for melting point of 240 'C -260 'C and having specific gravity 1.34 to 1.40, UV stable and alkali resistant( as per ASTM C 1116-02 and ICAO AC 32) to be used up to 0.25% by weight of cement complete all as per manufacturer's specification complete all as specified and directed
M&L for forming 25 mm thick and full depth of PQC of expansion joints filled with compressible closed cill premoulded high performance joint filler board HD-100 on top of filler board for complete width of joint provision of closed cell polyethylene rod 30mm dia filler with polyuethane sealent (minimum dpeth of sealent above polyethylene rod shall be of 15mm) complying with BS-5212 & BS-4254 and EN 141875-2003 (for hyddrolysis/water resistance test) pumpng the sides with minimum MAF + 30% (with ten years performance gurantee) and applying masking tape on edges of joint to prevent accidental spilage of sealent and removing the masking tape after sealent is applied by mechanical means complete all as specified and directed
M&L for forming dummy joint cutting with diamond cutter to depth of 80mm and 8mm wide initially and top 25mm, to accommodate polythylene rod and sealent 6mm wide provision of closed cell polythylene rod of 10mm dia sealent with (15mm depth minimum above polyethylene rod) polyurethene sealent complying with BS-5212 & BS -4254 and EN -14875-2003 (for hydrolysis/water resistance test) priming the sides with minimum MAF + 30%((with ten years performance gurantee) and applying masking tape on edges of joint to prevent accidental spilage of sealent and removing the masking tape after sealent is applied complete all as specified and shown on drawing
M&L for application of approved resign based aluminised refelctive curing compound @ 5 Sqm/litre over concrete surface having a water retention efficiency index of 90% in accordance with BS specification No-7542 or ASTM C-309-11 type-II relevent IS/IRC code
M&L for 10 mm thick layer of sand including watering and rolling over DLC all as specified and directed.
M&L for 400 micron transparent High Density Polyetyhlene (HDPE) film sheet Grade I conforming to IS-10889 laid over sand layer complete all as specified and directed. Note:-(i) Side lap of 150 mm and end lap of 300 mm shall be provided wherever required. The rate quoted shall be deemed included for the laps. (ii) Clear area only shall be considered for payment purpose and nothing extra shall be allowed for laps.
S&F MS plates (plain ro chequered) channels, angle, flats, square cut or notched (ordinary and counter sunk) forming holes, without any attachment and any cutting of PCC/brick work masonary complete all as specified and directed.
M & L for preparing new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M deep and getting out in soft/loose soil for laying of cable etc complete all as specified and directed
All as per item No 12 above but exceeding 1.5 M depth and not exc 3.00 M complete all as specified and directed
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm with excavated soil complete all as specified and directed
Removal of excavated soil to a distance not exc 50 m and depositing where directed complete all as specified and directed
Supply & laying well burnt sub class 'B' bricks, locally best available, laid in trenches for protection of underground cable complete all as specified & directed.
M&L for dry sand cushioning to underground cable provided with a layer of 8cm deep before laying the cable and 15cm deep after laying the cable including punning the sand up to 18 cm complete all as specified and directed
Supply, laying in trenches/ducts/through pipe/on wall/floor/ceiling, connecting and testing cable XLPE Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core,complete all as specified and directed. Make of cable- Finolex/ Grandlay/ Havells/ RPG(Asian)/ RR Kable
M & L for fabrication of MS chamber of suitable size out door type weather/vermin proof with one side opening duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted on CRCA sheet encloser including grouting on ground in suitable angle iron frame with four corners 1.5 mtr long grouted in PCC upto 0.9 mtr with PCC (1:3:6) with fixing of sheet metal enclosure single door distribution board SPN 6 way inside with MCB DP 40 amp-01 Nos and MCB SP 6 - 32 Amp-04 Nos complete all as sepcified and directed
M&L for submain wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable of size 2.5 Sqmm 1100 volts grade and one run of PVC insulated unsheathed solid copper conductor cable of size 2.5 Sqmm 1100 volts grade as earth continuity conductor drawn through in and including rigid metallic surface conduit of suitable size 20 /25 mm on roof/wall/ceiling including making good the disturbed surfaces of wall etc complete all as directed by Engr-in-Charge (Note : Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the unit rate
Supply and fix LED flood Light fittings 120 Watt 230 Volt AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection with impact and corrosion resistant with driver and lamp complete all as specified and directed.
M& L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire of 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I including and connecting to earthing test point and testing on completion with and including 40 mm bore light grade G.I. protection pipe (upto 7.5 M beyond outer edge of earth pit) PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1 (40 mm thick) cover reinforced with 6 mm dia M.S bars 3 Nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore medium grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earth work complete all as specified and directed
M/s A S Associates
M/S S J CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .