| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.1 LAccepted-AOC | ₹38.1 L Quoted ₹41.4 L | L1 | Accepted-AOC Accepted due to being Lowest Bidder |
| 2 | L2₹42.0 LRejected-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | ₹42.0 L | L2 | Rejected-AOC Rejected due to not being lowest bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Rejected due to non fulfiiling the requisite category as per NIT |
| Sl No | Description | Qty | Unit | M/s Rohit Construction Co. L2 | BHADU BUILDERS L1 |
|---|---|---|---|---|---|
| .10Notes:- (i) 100 percent nonperishable items of the work shall be deposited by the L1 bidder within 30 days after placing of work order. (ii) The critical path network shall be submitted by L1 bidder immediately after the acceptance of tender and approved by GE. (iii) The bidders must ensure to visit the site, check relevant documents and makes of materials required to be incorporated under the subject from concern Engineer-in-Charge. (iv) The unserviceable material obtained under the schedule of credit shall be handed over to the contractor by the Engineer-in-Charge on a proper gate pass. (v) In case of non-availability of any make mentioned under list of Makes, the L1 Bidder shall obtain non-availability / non-manufacturing certificate from the concern authorised dealers and submitted to Accepting Officer.In such case contractor shall be allowed to procure approved Group X item of SWC, Only after prior approval of GE. (vi) L1 Bidder shall produce E-way bill alongwith test certificate from OEM / manufacturer for costly items / major items of amount above Rs 50,000/- along with RAR’s and Final Bill. (vii) L1 Bidder shall be maintained an album containing Photos of all the material brought at site and each stage wise work progress and kept at site. Same shall be deposited in Engineer-in-Charge office after completion of work. (viii) The cost of all the above provisions shall be deemed to be included in the quoted rate of bidder, nothing extra shall be paid to the bidder. | |||||
| 1.00 | Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays, joints or laying underground cable etc. in soft/loose soil, complete all as specified and directed by Engineer-in-Charge. | 2,430 | Cubic metre | 100 ₹2.4 L | 60 ₹1.5 L |
| 2.00 | All as per item No. 01 above but exc 1.5m depth and not exc 3 mtr in depth complete all as specified and directed by Engineer-in-Charge. | 0.16 | Cubic metre | 300 ₹48 | 80 ₹12.80 |
| 3.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge | 1,400 | Cubic Metre | 20 ₹28,000 | 40 ₹56,000 |
| 4.00 | Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level n. exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-Charge. | 1,030 | Cubic Metre | 20 ₹20,600 | 40 ₹41,200 |
| 5.00 | Supply and fixing HDPE DWC Pipe dia inner dia 75mm and outer dia 90mm for laying of cable laid in trenches complete all as specified and as directed by the Engineer-in-Charge.
Note:- excavation and earth work shall be measured and paid for separately. | 1,600 | RM | 100 ₹1.6 L | 95 ₹1.5 L |
| 6.00 | Supply and fixing HDPE DWC Pipe dia inner dia 50mm and outer dia 63mm for laying of cable laid in trenches complete all as specified and as directed by the Engineer-in-Charge.
Note:- excavation and earth work shall be measured and paid for separately. | 600 | RM | 55 ₹33,000 | 70 ₹42,000 |
| 7.00 | Supply and fixing HDPE DWC Pipe dia inner dia 32mm and outer dia 40mm for laying of cable laid in trenches complete all as specified and as directed by the Engineer-in-Charge.
Note:- excavation and earth work shall be measured and paid for separately. | 7,000 | RM | 26 ₹1.8 L | 50 ₹3.5 L |
| 8.00 | Supply and fixing GI pipe light grade 50 mm bore (ISI marked) laid in trenches/ road crossings/ fixed to poles/ceiling / along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, complete all as specified and as directed by the Engineer-in-Charge. | 158 | RM | 300 ₹47,400 | 480 ₹75,840 |
| 9.00 | Supplying, laying, jointing, commissioning and testing in replacement XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 95 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. | 1,390 | RM | 530 ₹7.4 L | 450 ₹6.3 L |
Updated dates
Tender Value
₹44.2 L
EMD Value
₹88,360
Closing Date
7 Nov 2025, 6:00 pmClosed
GE (A) Suratgarh
GE ARMY SURATGARH MIL STN
SPL REPAIR FOR REPLACEMENT OF LT OH LINE INTO UG CABLE OF TARAPORE ENCLAVE AND SPL REPAIR FOR REPLACEMENT OF OLD UNSV SEWAGE NON CLOG PUMP IN THE AOR OF AGE EM UNDER GE SURATGARH AT SURATGARH MIL STN
2025_MES_734131_1
GE (A) SOG Token No 47/25-26
Open Tender
Electrical and Maintenance Works
180 days
Suratgarh
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (A) Suratgarh
₹88,360
Yes
1 Jan 2026
7 Oct 2025
10 Nov 2025
7 Oct 2025
7 Nov 2025
25 Oct 2025
Amount
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays, joints or laying underground cable etc. in soft/loose soil, complete all as specified and directed by Engineer-in-Charge.
All as per item No. 01 above but exc 1.5m depth and not exc 3 mtr in depth complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level n. exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-Charge.
Supply and fixing HDPE DWC Pipe dia inner dia 75mm and outer dia 90mm for laying of cable laid in trenches complete all as specified and as directed by the Engineer-in-Charge. Note:- excavation and earth work shall be measured and paid for separately.
Supply and fixing HDPE DWC Pipe dia inner dia 50mm and outer dia 63mm for laying of cable laid in trenches complete all as specified and as directed by the Engineer-in-Charge. Note:- excavation and earth work shall be measured and paid for separately.
Supply and fixing HDPE DWC Pipe dia inner dia 32mm and outer dia 40mm for laying of cable laid in trenches complete all as specified and as directed by the Engineer-in-Charge. Note:- excavation and earth work shall be measured and paid for separately.
Supply and fixing GI pipe light grade 50 mm bore (ISI marked) laid in trenches/ road crossings/ fixed to poles/ceiling / along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, complete all as specified and as directed by the Engineer-in-Charge.
Supplying, laying, jointing, commissioning and testing in replacement XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 95 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge.
All as per item No 09 above but cable of cross sectional area 70 sq mm 3.5 core.
All as per item No 09 above but cable of cross sectional area 50 sq mm 3.5 core.
All as per item No 09 above but cable of cross sectional area 35 sq mm 3.5 core.
All as per item No 09 above but cable of cross sectional area 16 sq mm 04 core for security light.
All as per item No 09 in replacement above but cable of cross sectional area 16 sq mm 04 core.
Dismantling existing unserviceable earth wire or copper conductor, service feeder or distributor span from overhead lines on LT poles, of any type and any size complete all as specified and as directed by Engineer-in-charge
Dismantling existing unserviceable Aluminium conductors, steel reinforced (ACSR conductor) from overhead lines on LT poles, of any type and any size complete all as specified and as directed by Engineer-in-charge
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m on LT poles, of any type and any size complete all as specified and as directed by Engineer-in-charge.
Dismantling existing unserviceable insulators of any type & any size on LT poles complete all as specified and as directed by Engineer-in-charge
Dismantling existing unserviceable stay assembly and concrete, etc complete all as specified and as directed by Engineer-in-charge
Suppyling, installing, testing and commissioning factory made outdoor type bus bar chamber having MCCB 4 Pole, 415 Volts, 125 Amps, 25KA of suitable size for operation on 415 volts, 3 phase, 4 wire, 50 Hz, outer shell made out of 3.15mm thick CRCA sheet duly powder coated coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the 200 Amps aluminium bus bar fixed Horizontally in staggred manner minimum length 450mm, 3 phases and neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty DMC insulators duly connected with 125Amps MCCB including provision for taking out incoming and outgoing cables detachable plate at bottom for cable entry and making six Nos hole in each bus bar including with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm complete all as specified and as directed by Engineer-in-charge.
Supplying and fixing in replecement same position new pre-stressed concrete pole 09 meter long of cross section 102mm x 172mm at the top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1978, including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.5 metre height from PCC coping and applying one coat of aluminum paint over cross arms, brackets, bracings, clamps, hooks etc. and marking pole number complete all as specified and as directed by Engineer-in-charge. Note: - (i) Earth work and PCC in foundation & coping shall be measured and paid for separately.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in new / old coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge
M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation for poles, struts & mass concrete including necessary form work and fair finishing to exposed surfaces complete all as specified and directed by Engineer-in-charge
Taking down LED security/street light fitting safely for reuse and refixing the same on new pole including connection with cable PVC insulated stranded copper conductor, 1100 Volts grade, 2.5 Sqmm 3 core size of ISI marked from Security light to Pole Box complete all as specified and directed by Engineer-in-Charge. Notes :- (i) Ladder wheel shall be arranged by the Contractor. (ii) Any T & P and Ladder wheel required for the work shall be arranged by the Contractor. The rate of this aspect is included in this item and nothing extra shall be paid on this account.
S & F in replacement LED Security light fitting of 45 watt including LED lamps complete with body robust corrosion resistant superior finish and without any cracks or through holes made in a single piece by high pressure die cast aluminium alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP 66 protection as per IS 10322-1982 (part-I) with latest amendments and input voltage range 140 - 300 V AC, frequency 50-60 Hz, P.F should be more than 0.9. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 and FRLSH cable PVC insulated stranded copper conductor, 1100 Volts grade, 2.5 Sqmm 3 Core size of ISI marked for Security light to Pole Box complete all as specified and directed Engineer-in-Charge. Havells cat Part LHEXBAP7PN7J050/ Crompton cat part No TRP-417-45-57-SL-LM-NBK/ Wipro Cat part No- LR02-501-XXX-57-G1
S&F cable junction box of size not less then 300x200x105mm, made of high quality thermo plastic polystyrene, weather proof, dust, jet water proof, chemical, acid corrosion, impact, insulated & shock proof IP 66 / 67 for outdoor Installation with internallly embedded gasket (PUR) including the box fitted with connector 8 way 40 Amps 01 No including Emlex stud type TB 4 Nos incoming / outcoming cable at controlled with MCB SP 6 Amps 01 No & enclosed along pole with MS flat iron clamp of suitable size complete all as specified and directed by Engineer-in-Charge. Make :- Sintex Cat Part No. GSJB-3020 or equivalent in Indokop / Hensel Note :- Cost of flat iron clamp is deemed to include in unit rate of this items.
Dismantling existing unserviceable service brackets, any type on LT poles, of any type and any size complete all as specified and as directed by Engineer-in-charge
Supply and fixing 32 mm dia 1.2 metre long GI pipe light grade bracket for fixing street light made to shape at including MS clamps (FI Plate 25X4mm as per site requirement) 02 Nos and nut and bolts duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete as required at site complete all as specified.
Supply and fixing weather proof PVC insulated, sheathed three core stranded aluminium conductor cable of size 1.5 Sqmm, 1100 Volts grade conforming to IS:9968 (Part-I) 1988 or IS:694-1990 complete all as specified and directed by Engineer-in-Charge. Make :- Havells / Finolex / Polycab
S&F Galvanized iron tubing, 15 mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ
Taking down old unserviceable sewage non clog submersible pump by disconnecting all electric connections and supply,installation,testing and commissioning of sewage non clog submersible pump set, capacity 7.5 HP, flow not less than 1100LPM at 14 mtr head, non clog to pass upto 40mm solids with 80mm dia section pipe necessary connections cable from pump to starter panel complete all as specified and directed.
M/s Rohit Construction Co. (BID ID -3463892)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
tender47.pdf
Tender Documents • 0.93 MB
BOQ_822061.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid