Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹30.5 LAccepted-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹32.1 L+₹1.4 L (4.43%)Rejected-Finance 5 A KALPANA NAGAR 7TH CROSSING MORAR GWALIOR MP | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L-2 | Rejected-Finance Being other than lowest. | |
| 3 | Rejected-Technical 91 DEFENCE ESTATE PHASE II NEAR AMBEDKAR PARK DEORI ROAD AGRA UP | AGRA | UTTAR PRADESH | 282001 | - | Rejected-Technical Due to not enlisting in appropriate Cat b (iii) | |
| 4 | Rejected-Technical | - | Rejected-Technical Due to non uploading of GST. |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
7 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GEAFADMAREAAGRA
GEAFADMAREAAGRA
OUTSOURCING OF SERVICES OF OPERATION OF ELECTRIC SUPPLY TOP NO 02 UNDER GE AF ADM AREA AGRA
2020_MES_336617_3
8000-1800/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GEAFADMAREAAGRA
Class D Cat d (v) and b (iii) and for un enlisted firms docs as per NIT
8 documents required · 8 mandatory
₹500
GEAFADMAREAAGRA
₹60,000
Yes
8 Sept 2020
17 Jun 2020
9 Jul 2020
17 Jun 2020
7 Jul 2020
24 Jun 2020
60 days
Amount
SCH 'A', PART-I : Operation, maintenance, repair and upkeep of 33 KV Main Receiving Station, 33 KV switch yard, 33 KV outdoor VCBs indoor remote control panel, 11 KV incoming/ out going VCBs and automatic tape changing control panel on round the clock basis by deputing operating staff in 3 shifts including recording of reading in log sheet including maintaining of all type of tripping record of 33 KV VCBs and all feeders of complete sub station, including labour for repair/ replacement of defective parts as and when required, all fixed and moving parts of isolator, drop out fuses etc, all as specified and directed. Note :-(i) Contractor shall provide and maintain all installation charts displayed daily recored of log sheet and cammunication system (mobile phone etc) and deemed to be included in the quated rate. (ii) Contractor shall provide uniform to each operator/ electrician and helper to maintain identity of operating staff employed by the contractor. (iii) Contractor shall provide protection shoes/ hand gloves and required tools for operation and maintance of 33 KV intallation. The details of staff are as under :- (i) SBA/ Skilled technician – 01 No (in each shift) (ii) Helper/ Mate Unskilled-01 No. BRIEF OF SUB STATION : (a) Transformer 33/ 11KV, 2 MVA capacity with OLTC - 02 Nos. (b) Transformer 33/ 0.433 KV, 100 KVA capacity - 01 No (c) 33 KV switch yard - 01 No (d) 11 KV VCB - 06 Nos (e) 33 KV outdoor VCB indoor remote control panel - 02 sets (f) Bus coupler of VCB 11 KV -01 No
SCH 'A', PART-II : Disconnecting & taking out of VCB for periodic maintenance of any description and any make/ capacity of rating 11 KV, dismantling/ opening of the VCB for servicing/ overhauling, taking out and removing found unserviceable/ defective parts including cleaning & servicing ,greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling/ servicing and its testing complete all as specified and directed. Notes :- (i) The quoted rates by the contractor includes for fixing of serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of BOQ as "supply only".
Supply only following spare parts for 11 KV VCB, 400/ 630 Amps capacity of Make: Crompton Greaves conforming to the respective cat part given as under :- Note : (i) Fixing & testing element of following items is deemed to be included under BOQ item No 2.00 here-in-before. (ii) Quantity of under mentioned items are tentative and contractor shall have no claim on account of variation of qty or non execution of any of the item. (a) Set of 3 Nos SPOUT bushing with CC parts (contact plug) upper 630/800 Amps.
(b) Set of 3 Nos SPOUT bushing with CC parts (contact plug) lower 630/800 Amps.
(c ) Vaccum intruppter type VL-35409 C2 or as per sample
( d) Space Heater
(e) Bridge rectifier
(f) Motor cut off limit switch.
(g) Auxiliary Switch (7 NO + 7 NC)
(h) Closing coil assembly 30 volts DC
(j) Tripping coil assembly 30 V DC
(k) Motor & Gear assembly 110 V AC/DC VMG - 14 type
Disconnecting & taking out of out door VCB for periodic maintenance of any description and any make/capacity of rating 33 KV, dismantling / opening of the VCB for servicing / overhauling, taking out and removing found unserviceable/defective parts including cleaning & servicing ,greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling / servicing and its testing complete all as specified and directed by Engineer-in-Charge. Notes :- (i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of BOQ as `supply only '
Supply only following spare parts for 33 KV VCB, 630 Amps capacity of Make: Crompton Greaves, conforming to the respective cat part given as under :- Note :(i) Fixing & testing element of following item is deemed to be included under BOQ item No 4.00 here-in-before.. (ii) Quantity of under mentioned items is tentative and contractor shall have no claim on account of variation of qtys or non execution of any of the item. (a) Vaccum intruppter type VL-35146-13F or as per sample
(b) Spring charging motor
Disconnecting & taking out VCB with its PT of any description and any make / capacity of rating 33 KV, dismantling / opening of the VCB and PT for servicing / overhauling, taking out and removing unserviceable/ defective parts including cleaning & servicing ,greasing, oiling of the parts etc and replacement of minor unserviceable parts ie. nut bolts , seal etc with new one, reassembling the same and its testing complete all as specified and directed.
Disconnecting & taking out non functional air break switch of any description and any make of rating upto 400 Amps, 33 KV, strip opening of the Air break switch for servicing/repairing, taking out and removing unsericeable/ defective parts from air break switch, cleaning & servicing including greasing, oiling decarbonising existing serviceable parts etc, fixing the serviceable parts in position and replacement of unserviceable parts with new one, making proper adjustement and setting, reassembling the Air break switch, fixing in position and its testing complete all as specified and directed. Note :- The quoted rates by the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for serparately under appropriate item of BOQ as “supply only”. .
Supply only the following spare parts suitable for GOD of 33 KV repaired under BOQ item No 7.00 here-in-before. NOTE :- (i) The new parts shall be suitable to match with the existing GOD. (ii) Fixing element of these items is deemed to be included under the rates quoted by the contractor for respective BOQ item No 5.00 here-in-before. (a) 33 KV post type insulator
(b) Male contact/ moving contact blade
(c) Female contact/fix contact Jaw
Supply and fix pin type, porcelain, vitreous, white, brown and green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150 mm dia for 33 KV all as specified and directed.
Supplying & fixing single disc assembly for disc type insulator porcelain vitreous 145mm high and 255mm dia including ball and socket , white , brown or green all as specified & directed by Engineer-in-Charge for HT overhead lines.
Filtration/ dehydration of transformer oil in transformer 33/11 KV and 11/.433 KV with centrifuging machine. The machine continuously run round the clock till obtaining the test of oil upto 60 KV dielectric strength in 2.5 mm gap and topping up with new transformer oil including commissioning and testing of transformers complete all as specified and directed. Note:- Transformer oil for topping up shall be measured in relevant items.
Supply, heating and filling/ topping up/ replacement of transformer insulating oil EHV grade having dielectric strength not less than 60 KV (R.M.S) at 2.5 mm gap high viscosity in transformer confirming to IS-335 of 1983 all as directed.
M&L for painting with two coats of aluminium paint on complete steel structure after scrapping the old paint from steel structures of 33 KV yard structure complete all as specified and directed.
Disconnecting and taking out existing unserviceable indicator lamps with holder of any description and in any position and Supply & fixing LED type indicating lamp suitable for 30 Volt DC /110 Volt AC/230 volts AC supply complete all as specified and directed.
Surface dressing and getting out including cleaning of 33 KV installation wild growth cutting in soft and loose soil complete once in a two months complete all as specified and directed. (Measurement shall be recorded at every cutting/ dressing and paid)
Testing of over current & earth fault High set IDMT microprocessor relays as per time/current characteristics by secondary injection test O/C 50%, 75%, 200% & E/F 20-80% plug setting and operating time at twice the set value & TMS 1 including well cleaning and decarbonizing of relay contacts.
M&L for complete checking of wiring including repair/calibration of VCB panel buchholz alarm relay,buchholz trip relay, 33 KV VCB alarm, VCB trip relays and make system serviceable complete checking of VCB 33 KV all as specified and directed.
Supply and fixing in replacement of auxilary relay 24 to 30 Volts DC type AVA 33 for 33 KV VCB control relay panel (Make- Ashida Electronic/L & T)
Supply and Fixing in replacement of PVC control cable 2.5 sqmm 12 core with PVC insulated and multistranded copper conductor including heavy duty PVC conduit and laid in existing cable duct from 33 KV outdoor VCB to indoor type control realy panel complete all as directed. Make- Havells/Plaza/Finolex.
Supply and fixing in replacement of PVC control cable 1.5 sqmm 4 core with PVC insulated and multistranded copper conductor including heavy duty PVC conduit and laid in existing cable duct from 33 KV outdoor VCB to indoor type control realy panel complete all as directed. Make- Havells/Plaza/Finolex.
Supply and fixing in replacement of PVC control cable 1.5 sqmm 2 core with PVC insulated and multistranded copper conductor including heavy duty PVC conduit and laid in existing cable duct from 33 KV outdoor VCB to indoor type control realy panel complete all as directed. Make- Havells/Plaza/Finolex.
Supply and fixing HRC fuse 2 to 10 Amps complete all as specified and directed.
M & L for replacement of PG clamps, parallel grove clamps, tee clamps & GI nut, bolts of required size other connectors for connecting ACSR dog conductors for jumpring all as required at site all as specified and directed.
M & L for jump ring PTs, CTs, Outdoor VCB, isolators, DO fuse by using parallel grove clamp, Tee Clamps other connectors required by using ACSR conduc tor size Dog (6/4.72+7/1.57) including dismantling old conductor and clamp complete all as specified and directed.
M & L for checking and finding out pin point location of fault in HT 11 KV grade underground cable with the help of fault locating mobile machine complete all as directed. (Note :- Rate for rent of the fault locating mobile machine, charges for operator, engineer, electricians etc are deemed to be included in the quoted rate.
Supply, jointing and testing straight through cold shrinkable joint including all materials and accessories suitable for 3 core x 240/400 sqmm XLPE cable of 11000 Volt grade all as per manufacturers recommendation complete all as specified and directed. Make : Dension/M Seal/Cab Seal.
.-Ditto- all as per item No 26.00 here-in-before but suitable for 3 core 120 to 185 sqmm.
Supply, jointing and testing indoor type cold shrinkable end termination cable joint including all materials and accessories suitable for 3 core x 240/300 sqmm XLPE cable of 11000 Volt grade all as per manufacturers recommendation complete all as specified and directed. Make : Dension/M Seal/Cab Seal
.-Ditto- all as per item No 28.00 here-in-before but suitable for 3 core 120 sqmm to 185 sq mm.
Supply, jointing and testing outdoor type cold shrinkable end termination cable joint including all materials and accessories suitable for 3 core x 240/300 sqmm XLPE cable of 11000 Volt grade all as per manufacturers recommendation complete all as specified and directed. Make : Dension/M Seal/Cab Seal
.-Ditto- all as per item No 30.00 here-in-before but suitable for 3 core 120 sqmm to 185 sqmm.
Supply, jointing and testing indoor type cold shrinkable end terminal cable joint including all materials and accessories suitable for 3 core x 240/300 sqmm XLPE cable of 33000 Volt grade all as per manufacturers recommendation complete all as specified and directed. Make : Dension/M Seal/Cab Seal
M&L for painting with two coats of smoke gray paint on VCB panel after cleaning dust, dirt and oil and scrapping old paint including writing SM No/ MES No/ Machine No and capacity etc all as specified and directed.
M&L for painting of transformer 33/11 KV after scrubbing out dust, dirt and oil from all places of 2 MVA transformer including connection steel structure complete as per existing at site and applying with one coats of synthetic enamel paint of existing colour or as approved by GE including writing MES/ SM No capacity/ Make etc all as specified and directed.
-Ditto- all as per item No 34.00 here-in-before but 33/0.433 KVA transformer.
Disconnecting and taking out existing unserviceable current transformer of any description and in any position and supply , fixing and testing of cast resin type 11 KV current transformer having a ratio 200-100/5 A having protection core SP-10 burden of 15 VA and metering core class 1.0 and burden of 15 VA breaking capacity 13.1 KV for 1.0 second complete all as specified and directed. (Make : Jyoti/Skipper/Alsom/Crompton Greaves)
Disconnection and taking out of unserviceable supervision relay of any type from existing HT VCB panel in any position and supplying, installation, commissioning & testing of electronic type Product cod trip supervision relay 24 V to 110 V DC. Make - Cromption Model No. TH 30 or equivalent
S & F high voltage insulating mats class C categary III, thickness 3.0mm confirming to IS : 15652 (ISI marked) pastable type,permanently fixed smooth trolly movement,moisture proof fire retardant,no adverse effect of acids,alkalis transformer oil & disel suitable for working up to 11 to 33 KV electrical installations.(Make :-Jyothi Rubber/Nexans/3M/Catu)
S & F in replacement of high set HT 11KV power factor display digital type and fixed on existing power factor VCB including testing as directed. Make- L&T/CG/Easun Reyroll/AE/Arvea
Disconnecting and taking out existing unserviceable differential current transformer of any description and in any position and supply , fixing and testing of cast resin type 11 KV differential current transformer having a ratio 150/100/5/5 1Amp 3 core having protection core complete all as specified and directed. (Make : Jyoti/Skipper/Alsom/Crompton Greaves)
Supply and fixing in replacement of 33KV out door type gang operated switch rotating type, double break, or currecnt rating upto 400 Amps, triple pole, each pole consisting of galvanised steel base, HT insulators as per IS, non ferrous knife and spray, loaded contacts, arcing horns of adquate section to break magnetizing current of the transformers horizontal GI pipe of adequate length for phase separation, adequate length of GI pipe for operation from ground level and operating handle with locking arrangement complete in both OFF & ON positions. All ferrous parts hot dripped galvanized and non ferrous heavily tinned to withstand weather and suitable for vertical mounting complete all as specified and directed. (Make : Jaipuria Brothers /HEI/ECE Kolkatta/Pectal)
S&F marshelling box with all connectors of factory made of IP 65 protection,dust proof,water proof polycarbonate double insulated gasket inbuilt,fire retrdant of size 300 mm x 450 mm of suitable depth complete all as specified and directed.
S&F marshelling box with all connectors of factory made of IP 65 protection,dust proof,water proof polycarbonate double insulated gasket inbuilt,fire retrdant of size 200 mm x 250 mm of suitable depth complete all as specified and directed.
Supply and Replacement of fresh silica Gel complete all as specified and directed.
Replacement of air breather assembly any type complete with filled silica Gel as per sample.
Replacement of winding temp indicator with senser as per original size.
S&F digital type Volt meter 0-15KV, PT operated 110 Volt input complete all as specified and directed. Make - AE/ Nippen
S&F digital type Ammeter CT operated, 5 Amp input complete all as specified and directed. Make - AE/ Nippen
S&F in replacement of box type display in cuboid shape made of acrylic both side framed with stainless steel pipe of size of 6x4 feet including LED strip of suitable size fixed inside of size of text 20 cm to 10 cm or as directed. sheet board of 6 mm size heavy duty including writing alphabetic letters computerised with rflective sheets to be made as all directed by Engineer-in-Charge.(Note :- 150mm fonts and fixed with stainless steel pipe heavy duty of size 40 to 50 mm bore and to be fixed in the installations duly burried the ground along with required PCC and FFL top of the sign board should be 2.5 mtr will be deemed in quoted rates).
S&F in replacement post top lantern 35/ 40 Watts, 230 volts, 50 Hz with IP 65 protection, mushroom or oval shaped in opal/ prismatic finish made out of polycarbonate, suitable for 40 Watts LED all accessories and prewired complete all as specified and directed. Make:- Crompton Cat Part No:- LPTO-40-CDL / Havells Cat Ref RUBYPT35WLED757PSYMTOPC.
S&F in replacement LED bollard of 8/10 watts, 230 volts, 50 Hz with IP 65 protection with robust design and efficient light distribution complete all as specified and directed. Make:- Havells Cat Ref BAMBOOBL8WLED757PSYMTOPC.
M/S SANTOSH CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .