Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-AOC R G BARUAH ROAD NEAR SHIV MANDIR GUWAHATI AIRPORT GUWAHATI 781015 | KAMRUP METRO | ASSAM | 781015 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹21.6 L+₹4.2 L (24.0%)Rejected-Finance SHREE KUNJ HOUSE NO 22B JIBAN KRISHNA PATH NEAR L P SCHOOL HENGRABARI GUWAHATI PIN 781036 | GUWAHATI | KAMRUP | ASSAM | 781036 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹22.9 L+₹5.6 L (32.0%)Rejected-Finance 3RD FLOOR STAR ENCLAVE GNB ROAD PAN BAZAR GUWAHATI 781001 | GUWAHATI | KAMRUP METRO | ASSAM | 781001 | L3 | Rejected-Finance Other than L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
13 Sept 2023, 6:00 pmClosed
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati-15, Assam, Pin- 781015 Tele 0361 - 2840127
REPAIR/MAINT OF VRF AC PLANT AT CERTAIN TECHNICAL AND DOMESTIC AREA OF 19 WING, AF AND SUPPLY OF REFRIGERANT GAS UNDER GE (AF) BORJHAR
2023_MES_612112_1
8352/BOR/E8
Open Tender
Electrical and Maintenance Works
Percentage
180 days
GE (AF) Borjhar
MES Contractor enlisted as Class E category c (i) having deposited Standing Security of Rs 50,000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Borjhar
₹50,000
Yes
4 Nov 2023
4 Aug 2023
20 Sept 2023
4 Aug 2023
13 Sept 2023
18 Aug 2023
Amount
M&L for repair and comprehensive maintenance of moudular type Variable Refrigerant Flow (Make Samsung) system (22 x 3 HP, 12 x 2 HP ) equipped with invertor, compressors, acrylic precoated heat exchanger, low noise Condenser fan, auto check function for connection error, auto address setting with any capacity Modules and any location Including replacement of all thermocol foams insulating materials and any type of packing material, PVC drain pipe connections and any item required for replacement like as copper tubling gasket pumps, fan motor etc through authorised service provider for the complete plant by servicing/replacing any type spare parts as and when required to outdoor, indoor units including compressor, condensor, PCBs, valves, fan motors, piping, insulation refrigerant during the period of contract and in one year liability period complete all specified and as directed.
M&L for repair and comprehensive maintenance of moudular type Variable Refrigerant Flow (Make Carrier) system 12x4HP equipped with invertor, compressors, acrylic precoated heat exchanger, low noise Condenser fan, auto check function for connection error, auto address setting with any capacity Modules and any location Including replacement of all thermocol foams insulating materials and any type of packing material, PVC drain pipe connections and any item required for replacement like as copper tubing gasket pumps, fan motor etc through authorised service agent of manufacturer for the complete plant by servicing/replacing any type spare parts as and when required to outdoor, indoor units including compressor, condensor, PCBs, valves, fan motors, piping, insulation refrigerant during the period of contract and in one year liability period complete all specified and as directed.
NOTE (for Serial Items No. 1 & 2) (i) one year guarantee certificate to be submit by the contractor before completion of work (ii) The cost of thermocol foams and any type of packing material, PVC drain pipe etc shall be deemed to be included in the unit rate of this item. Nothing extra shall be entertained on this account (ii) Spare parts like as PCBs, Harmony, thermistors, drain pump & motor shall be measured & paid as Supply only seperatly under respective item No. 3 to 16 of this schedule. Fixing charges of spare parts shall be deemed to be included in the unit quoted rate.
Supply and fixing new Fan PCB Main assembly complete all as specified and as directed. Make : Samsung, Cat No.DB92-03341A or equivalent model from MES approved makes.
Supply and fixing new SUB (HUB) PCB Main assembly complete all as specified and as directed. Make: Samsung, Cat No.DB92-03342A or equivalent model from MES approved makes.
Supply and fixing new Invertor PCB Main assembly complete all as specified and as directed. Make-Samsung, Cat No.DB92-03526A or equivalent model from MES approved makes.
Supply and fixing new Main Display PCB Main assembly complete all as specified and as directed. Make-Samsung, Cat No.DB92-03340A or equivalent model from MES approved makes.
Supply only new EMI PCB Main assembly complete all as specified and as directed. Make-Samsung, Cat No.DB93-13529A or equivalent model from MES approved makes.
Supply only new Drain pump complete all as specified and as directed. Make-Samsung/Carrier/Blue Star/Voltas
Supply only new Thermostat complete all as specified and as directed. Make :Samsung/Carrier/Blue Star/Voltas
Supply only new Coil Harmonic complete all as specified and as directed. Make : Samsung, Cat No.DB27-00094A or equivalent model from MES approved makes.
Supply only new Motor complete all as specified and as directed. Make-Samsung, Cat No.DB31-00578A or equivalent model from MES approved makes.
Supply only new fan motor PCB Main assembly suitable for 12 HP VRF AC Plant complete all as specified and as directed. Make-Carrier/Blue Star/Voltas/LG
supply only new float switch suitable 24 HP VRF AC plant complete all as specified and directed by Engr-in-Charge. Make : Carrier/ Samsung or equivalent MES approved make.
Supply only new DC Invertor PCB Main assembly complete all as specified and as directed. Make- Carrier/Blu Star/Voltas/LG
Supply only new main Display PCB Main assembly complete all as directed by Engr-in Charge. Make- Carrier/Votas/Blue Star/LG
supply only new indoor unit PCB for VRF AC plant complete all as specified and as directed by Engr-in-Charge. Make :Carrier/ Samsung or equivalent MES approved make.
supply only new indoor unit Motor for VRF AC plant complete all as specified and as directed by Engr-in-Charge. Make :Carrier/ Samsung or equivalent MES approved make.
Disconnecting to unserviceable sealed compressor of suitable for 24 HP VRG AC plant and replaced with new hermatical sealed compressor of existing make and model including soldering of liquid/ gas pipe, cleaning the system arresting the leaking, vacuum sing, initial charging of oil and refrigerant gas as requited including installation, testing and commissioning complete all as specified and as directed by Engr-in-Charge.
M&L for insulation for drain pipes and condensor copper pipes as per existing type rubber insulating materials suitable for VRF Plant ccomplete all as specified and as directed.
Supply and fixing 2.5 sq.mm multi core sheated cable for connection between indoor unit inluding with accessories PVC conduit of size 15/20mm dia complete all as specified and as directed. Note: The VRF AC Plant must be repaired or serviced through OeM (Carrier and Samsung) or his authorized Service Centre. Necessary documents as required to be submitted by the bidder to Engineer-in-Charge prior qualifying of the bidding.
Supply of refrigerant gas, R-134A in 10 Kg cylinder
Supply of refrigerant gas, R-410A in 8 Kg cylinder
Supply of refrigerant gas, R-22 in 10 Kg cylinder
Supply of refrigerant gas, R-32 in 7.5 Kg cylinder
Supply of refrigerant gas, R-407C in 7.5 Kg cylinder
M/S PRASANTA MAHANTA
saitraders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .