Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.7 LAccepted-Finance VIII GHORAULI KALA P O NIGAH DISTT SINGRAULI M P | SINGRAULI | SINGRAULI | M P | ₹54.7 L | L1 | Accepted-Finance L1 |
| 2 | L2₹55.5 LRejected-Finance VILL BASI PO BINA DISTT SONEBHADRA UP 231220 | BINA | SONEBHADRA | UTTAR PRADESH | 231220 | ₹55.5 L | L2 | Rejected-Finance L2 |
Updated dates
Tender Value
₹92.9 L
EMD Value
₹1.2 L
Closing Date
2 Jan 2026, 11:00 amClosed
S.O.(CIVIL)
S.O.(CIVIL) Khadia Area Dist.-Sonebhadra U.P.
Development works of dragline section and making rooms for office, store, welding etc. for dragline bucket repair yard at Khadia Project
2025_NCL_349211_1
GM/KHD/C/25-26/ETN-87 Date11/12/2025
Open Tender
Civil Works - Others
150 days
Khadia Area Dist.-Sonebhadra U.P.
REFER NIT
5 documents required · 5 mandatory
₹1.2 L
12 Feb 2026
11 Dec 2025
3 Jan 2026
11 Dec 2025
2 Jan 2026
12 Dec 2025
11 Dec 2025 - 22 Dec 2025
Item Description/ Heading
PART A
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu- ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Brick work with FALG bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Supplying at site : R.C.C. Standards post/ struts/rails/ pales of mix 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs wherever required as per direction of Engineer-in- charge (cost of earth works in excavation, concrete works in foundation to be paid separately).
Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :- Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
Providing and fixing bolts including nuts and washers complete.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and .I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.80 mm thick with zinc coating not less than 275 gm/m²
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.80 mm thick with zinc coating not less than 275 gm/m²
Extra for providing and fixing wind ties of 40x 6 mm flat iron section.
Supply of 10Sqmm 4Core Copper cable including overhead lying with proper support with steel conductor at both side or underground with min 1.5 mtr depth as required. ISI marked confirming to IS694. as per the instruction of EIC.
Wiring for light/ power plug/Separate AC connection with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required (Make-Havells, Anchor, Polycab or equivalent)
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire) (Make-Havells, Anchor, Polycab or equivalent)
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2 X 6 sq. mm + 1 X 6 sq. mm earth wire) (for Mains to Sub Mains Wiring) (Make-Havells, Anchor, Polycab or equivalent)
Supplying and fixing following modular type switch/ socket on the existing switch box/ cover including connections etc. as required.15/16 A switch
Supplying and fixing following modular type switch/ socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 A socket outlet
Supplying and fixing following size/ modules, PVC box along with modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm)
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/led light of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, Testing and Commissioning of exhaust fan in the existing opening or or with drilling hole of suitable size as required , including making good the damage, connection, testing, commissioning es required including wiring with 2.5 sq. mm FRLS PVC insulated, copper conductor (Upto 450 mm sweep)
Supplying, installing, testing and commissioning of 100A TPN made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections with copper lugs, earthing,concreting etc. as required
Supplying and fixing of 12 way,double door, single pole and neutral, sheet steel, MCB distribution board, 240V/415V,on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthingetc. as required. (But withoutMCB/RCCB/Isolator)
Supplying and fixing 5A to 32A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning including wiring inside DB etc. as required.
Supplying and fixing of 63 amp, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply and fixing of 100A 4P MCCB confirming to IS/IEC 60947-2,with 30kA short circuit breaking capacity,with adujstable trip characteristics setting including installation in a suitable size fixed feeder panal with proper earting including supply of panel and ground concreting as required.
Supply and fixing of 200A 4P MCCB confirming to IS/IEC 60947-2,with 30kA short circuit breaking capacity,with adujstable trip characteristics setting including installation in a suitable size fixed feeder panal with proper earting including supply of panel and ground concreting as required.
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Erection, testing and commissioning of maintenance free earthing electrodes including brick work around the earth pit
supply of Safe and maintenance free earthing electrodes (GI pipe dia-40mm, length- 03 mtr as secondary electrodes and 02 nos hot dipped galvanized strip size 25x6 mm length 03 mtr as primary electrodes.
supply and filling of Side filling compound (Bentonite powder)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supplying,installation,testing and commissioning of Astronomical time switch capable of following output in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required including supply of suitable size contactor with enclousre box and complete installation and fitting, wiring (one output per phase and suitable for single phase supply)
Supply, Installation, testing and commissioning of wall fan 600MM sweep 220V/230V fully enclosed, confiring to IS, Alumi
nium 3 blades, Copper motor winding, 1440RPM, 0.75hp motor, Verticle adjustment, osslication adjustment, including wiring with 2.5 sq. mm FRLS PVC insulated in surface / recessed medium class PVC conduit, copper conductor, single core cable including earting wire, as required. (Make-Havells, Bajaj, Philips or Equivalent)
Supply of exhaust fan 450MM sweep size 220V/230V 1400RPM fully enclosed with louver shutter, confirming ot IS 2312, . (Make-Havells, Bajaj, Philips or Equivalent)
Total impact of GST for the purpose of CTC
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 2.78 MB
BOQ_361944.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid