| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹29.0 L+₹16,112 (0.56%)Rejected-Finance VILL CHOMON ADAMPUR JALANDHAR PUNJAB 144103 UDYAM PB 10 0011450 | JALANDHAR | PUNJAB | 144103 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹31.0 L+₹2.2 L (7.52%)Rejected-Finance NEAR RAILWAY CROSSING ADAMPUR DOABA JALANDHAR JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹31.4 L+₹2.6 L (8.87%)Rejected-Finance GP RAM COLONY AMRITSAR JALANDHAR 144103 | AMRITSAR | AMRITSAR | PUNJAB | 144103 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹32.3 L+₹3.5 L (12.1%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹58,000
Closing Date
3 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Air Force
Military Engineer services AF Stn Adampur 144103
CONSTRUCTION OF VOCATIONAL LAB IN KV NO. 2 AT AF STN ADAMPUR
2024_MES_652667_1
GE/AF/ADM-07/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE AF Adampur
Refer NIT and Tender documents
8 documents required · 8 mandatory
₹500
GE AF Adampur
₹58,000
Yes
27 Jun 2024
7 May 2024
4 Jun 2024
7 May 2024
3 Jun 2024
21 May 2024
8 May 2024 - 20 May 2024
Amount
BR WORKS
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in SOFT/LOOSE soil complete, all as specified.
Excavation over areas in SOFT/LOOSE soil not exceeding 1.50 metre deep and getting out complete, all as specified.
Excavation over areas in SOFT/LOOSE soil exceeding 1.50 metre but not exceeding 3.00 metre deep and getting out complete, all as specified.
Excavation in trenches n. exc 1.5 m wide for foundations, laying cables/ pipes etc. not exceeding 1.5 m deep and getting out in SOFT/LOOSE soil complete, all as specified.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete, all as specified.
Sand filling under floors including spreading and levelling in layers n exc. 25 cm thick and well ramming including watering as required complete, all as specified.
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
Broken bricks hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete, all as specified.
Anti-termite treatment of soil by treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured) complete all as specified.
Anti-termite treatment of soil by treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified.
Anti-termite treatment of soil by treating soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified.
Anti-termite treatment of soil by treating soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified.
PCC type D-2 (1:4:8), using 40 mm graded stone aggregates as in filling & mass concrete, complete all as specified.
Cement concrete, type B-0 (1:2:4), using 12.5 mm graded stone aggregates as in lintels up to 1.5 metre clear span, bed blocks, copings and the like including weathering, slightly rounded or chamfered angles & throating including provision of necessary formwork, complete all as specified.
Reinforced cement concrete, M-25 (Design Mix), as in in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified.
Reinforced cement concrete, M-25 (Design Mix), as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified.
Reinforced cement concrete, M-25 (Design Mix), as in chajjas, and the like complete all as specified.
Reinforced cement concrete, M-25 (Design Mix), as in beams, cantilevers, bressumers, lintels over 1.5 metre clear span and the like complete all as specified.
Reinforced cement concrete, M-25 (Design Mix), as in columns, pillars, piers, posts and struts complete all as specified.
Brick work using bricks as specified in PS-II clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified.
Brick work in half brick thick wall using bricks as specified in PS-II clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:4), complete all as specified.
Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finished surfaces of concrete, complete all as specified.
Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) with fair finished surfaces of concrete, complete all as specified.
Use & waste of formwork to chajjas, troughs and similar items including edges with rough finished surfaces of concrete, complete all as specified.
Use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. with rough finished surfaces of concrete, complete all as specified.
Use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions with rough finished surfaces of concrete, complete all as specified.
Factory made, 35 mm thick, second class hard wood, plain framed, hammer marked, skelton shutter (two panel to receive wire gauge) with lock rail. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified.
Factory made, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, 30 mm thick, ISI marked, complete all as specified.
Factory made single extruded WPC (Wood Polymer Composite) solid door/ window /Ceosetory windows & other Frames/Chowkhat of size 63x51 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gm) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/Cu.m, screw withdrawl strength of 2200N Face & 1100 N (Edge), minimum compressive strength of 58 N/ Sq.mm, modules of elasticity 900 N/Sq.mm and resistance to spread of flame of Class A category with property of being termite /borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete.
Factory made single extrudeed WPC (Wood Polymer Composite) solid plain flush door shutter of 18mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), clacium carbonate and natural fibres (Wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gm) having minimum density of 650 kg/Cu.m and screw withdrawl strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50N/Sq.mm, modulus of elasticity 850 N/Sq.mm and resitance to spread of flame of Class A category with property of being termite/borer proof, water / moisture proof and fire retardant and fixing complete.
Stainless steel conduit 20 mm bore, cut to size and erected in position as curtain rod on backets, with & including SS decorative finials & brackets, PVC rings @ 10 nos. per metre, fixed to walls with PVC rawl plugs & SS screws, complete.
Stainless steel, barrel tower bolt, 150 mm long, with stainless steel screws, complete all as specified. MAKE :PRAYAG CAT NO. TBS-2150 or equivalent make mentioned in Appndix 'B'
Stainless steel (SS-202) sliding door bolt with hasp and staple (bolt type) and fixing round typeclips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy 250 mm long complete. MAKE: PRAYAG CAT NO. SLD-1210 or equivalent make mentioned in Appndix 'B'
Stainless steel, handle, 125 mm long, curve shapewith stainless steel screws, complete all as specified. MAKE: PRAYAG CAT NO. DHC-2125 or equivalent make mentioned in Appndix 'B'
Stainless steel, handle, 150 mm long, curve shapewith stainless steel screws, complete all as specified. MAKE: PRAYAG CAT NO. DHC-2150 or equivalent make mentioned in Appndix 'B'
Hasp and staple, safety type, stainless steel including bolt to hinge plate and fixed with screws of size 100 mm, ISI marked complete all as specified.
Double leg aluminium anodised door stopper with rubber foot, ISI marked and fixed to bottom rail of doors with steel screws, complete.
Aluminium (Die cast) door closer hydraulically regulated designation No. 3 aluminium body universal type suitable for door shutters of 851 to 1000 mm in width and weight between 61 to 80 kg, ISI marked, complete all as specified.
Stainless steel 100mm size auto soft closing hydraulic hinges fixed with stainless steel screws, ISI marked complete all as specified. MAKE:-Godrej / Prayag / Hettich
Galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks or galvanized wire staples, all as specified.
Framed mild steel work such as grills, grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-290-Gde E-165, complete all as specified.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
Mild steel TMT bars 5 mm and over up to and including 10 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips in stirrups, spacers and binders complete all as specified.
Factory made steel windows with side hung shutter with glazng bars each shutter having 02 No. box type hinges & two nos. tower bolts of size not less than 150 mm size and peg stays, dovetailed or welded, including one shop coat of zink chromate primer complete.
Factory made steel windows with side hung shutter without glazng bars each shutter having 02 No. box type hinges & two nos. tower bolts of size not less than 150 mm size and peg stays, dovetailed or welded, including one shop coat of zink chromate primer complete. NOTES APPLICABLE TO SERIAL ITEM NO. 45 TO 46: (a) Profile section used under these items shall be 'P' tube as shown in drawing No. CE/AF/STD-170/07, CE/AF/STD-171/07 and CE/AF/STD-172/07 as applicable. (b) Cost of one shop coat of zink chromate primer shall be measured and paid for separately under respective item of painting.
Factory made pre painted pressed steel frames, conforming to IS, having profile 125 mm x 60 mm for doors with one or more rebates made out of 1.25 mm thick mild steel sheet, including necessary fixing lugs, ISI marked 100mm long butt hinges 3 Nos each side , lock strike plate, etc., duly filled with PCC(1:3:6) type C-0 complete, all as specified.
Water Proofing Treatment to RCC roofs comprising of : -
15 mm thick (Average thickness) rendering on roof surface including flashings and junction of parapets etc., finished even and fair in cement mortar (1:4), using water proofing compound as recommended by manufacturers after brushing cement slurry @ 1.20 kg/Sq. m, when the concrete is green, complete all as specified. NOTE: Supply only WPC will be measured & paid for separately under respective item of BoQ.
APP based polymeric membrane laid on primed roofs & flashing by forced application using Butane torch and sealing all joints on primed surface by applying hot blown industrial grade bitumen @ 85/25 @ 1.20 kg/Sq.m over a coat of bitumenous primer @ 0.40 litre per square metre over clean RCC/plastered roof surfaces & flashings and thereover applying a coat of black bitumenous paint complete, all as specified.
25 mm thick, cement concrete type B-0, 1:2:4 using 12.5 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified.
75 mm thick, cement concrete type C-1, 1:3:6 using 20 mm graded stone aggregate, finished even & smooth without using extra cement, as in plinth protection, and joints shall be sealed with joint sealing comound grade 'A' complete all as specified.
75 mm thick, cement concrete type D-2, 1:4:8 using 40 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified.
Machine cut Kota stone slab flooring 15-18 mm thick and of size not less than 550x550 mm, in floors, laid over over & including 20 mm thick (average thickness) cement mortar (1:3) screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (Granite finish) complete, all as specified.
Machine cut Kota stone slab 15-18mm thick on vertical surfaces as in staircase riser skirting/ dado etc over and including 10 mm thick rendering in cement mortar (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified
Granite jet black shade, 15-18 mm thick,as in step, jambs, cooking platform and like, machine cut, machine polished, bedded and jointed with grey cement slurry & pointed with grout of matching shade including necessary cutting over & including 10 mm thick (average thickness) cement mortar (1:4), complete all as specified.
Rounding of / moulding to edges (half round) of stone of any description including rubbing and polishing (Granite finish), complete all as specified.
Glazed ceramic coloured tiles not less than 7mm thick, area of each tile exc. 0.17 Sq.m but n. exc. 0.19 Sq.m on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 10 mm thick bedding layer in cement mortar (1:4), complete all as specified.
80 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of shape approved by GE, made by table vibratory method using PU mould, laid in required pattern over and including 50mm thick compacted bed of coarse sand, compacting through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete.
Rendering 5 mm thick on fair faces of concrete surfaces, finished even and smooth on ceiling in cement mortar (1:3), complete all as specified.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:6) complete all as specified.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), mixed with water proofing compound as per manufacturers instructions, complete all as specified. NOTE: WPC will be measured and paid for separately under respective item of BoQ.
Supply only water proofing compound, ISI marked, complete all as specified.
Prepration of new plasterd ceiling surfaces of any description complete all as specified and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed). (b) Two coats of plastic emulsion over and including a coat of interior primer.
Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed). (b) Two coats of plastic emulsion paint over and including a coat of interior primer.
Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: - a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed).complete all as specified. (b) Two coats of exterior acrylic emulson over and including a coat of water based exterior primer complete all as specified.
Plain sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads in squares n. exc. 0.5 Sq.m in each pane complete all as specified.
Two coats of synthetic enamel paint over & including a coat of pink primer over wood and wood based surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces, complete all as specified.
Two coats of synthetic enamel paint over & including a coat of red oxide primer over steel or iron surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces, complete all as specified.
500 litre capacity, white, three layered polyethylene water storage tanks (cylindrical vertical with threaded lid) including hoisted and fixed in position, making connections, complete all as specified including the following acessories: - (i) Gun metal ball valves, high pressure, with metal rod & high density plastic ball complete screwed for iron pipe or brass ferrule and fixed, suitable for 20 mm bore GI pipe, complete all as specified. (iii) Gun-metal stop valve (quarter turn type) with MS lever handle, suitable for 20 mm bore GI tubes, ISI marked, screwed both ends for iron pipe, complete all as specified. (iv) Provn of 20 mm bore GI light grade tube from O/H tank to nearest mouth of RWP/outer edge of roof, complete all as specified.
Steel tubes 15 mm bore ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, complete all as speciifed.
Steel tubes 20 mm bore ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, complete all as speciifed.
Steel tubes 25 mm bore ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, complete all as speciifed.
Bib tap, cast copper alloy, chromium plated fancy type, long body with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, complete. MAKE: KEROVIT Cat No. KB2111033 or equivalent make mentioned in Appendix 'B'.
Brass chromium plated towel rail 500-600 mm long, fixed to wall with SS screws and PVC rawl plugs, complete. MAKE: KEROVIT Cat No. KA930001 or equivalent make mentioned in Appendix 'B'.
Stainless steel round slotted grating with frame, 100 mm size fixed in position with cement joints, complete all as specified.
Stainless steel (SS-304) sink made out of 1.00mm thick sheet for kitchen or laboratory with plug waste pipe washers including cantilever cast iron brackets connecting union etc overall size 405 mm x 354mm x 203mm with bowl size 914mm x 460mm x 203mm, complete all as specified. MAKE: PRAYAG Cat No. 1339D or equivalent make mentioned in Appendix 'B'.
uPVC pipes 110 mm external dia, type-B, ISI marked (IS:13592) single socketed in any length with or without rubber ring joints, fixed under floors/walls as SWR pipes, complete all as specified.
uPVC/PVC bend any radius, suitable for uPVC soil waste discharge pipes 110 mm external dia, complete all as specified.
Concrete bed to drain pipes 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; in Cement concrete 1:3:6 type C-2, complete all as specified.
Reinforced concrete pipes 150 mm bore, class NP-2, laid and jointed complete with collars, laid in trenches and jointed, ISI marked, complete all as specified.
Cutting into existing manholes for connecting new drains, of 150 mm bore pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished, reforming benching as required, complete all as specified.
uPVC / PVC 100 mm bore floor trap including jointing with solvent and embedding in cement concrete type B-1 (1:2:4),complete all as specified.
EM WORKS
Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with 3 mm thick plastic laminated sheet cover having necessary cutting for fixing switches/ sockets comprising the following: -
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified.
One Socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One socket outlet three pin, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
NOTES: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4) complete all as directed. (c) Conduit shall be laid on surface in case of RCC ceiling surfaces.
Switch piano flush button single pole one way, 6 Amp complete all as specified.
Switch piano flush button single pole one way, 16 Amp complete all as specified.
Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, flush type, complete all as specified.
Socket outlet multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, flush type complete, all as specified.
Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete, all as specified.
Fan regulator (electronic) suitable for 48”/56” sweep fan, step down type, single phase, complete all as specified.
Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, suitable for surface and flush mounting, complete all as specified comprising VTPN, 4 way with 200 Amp rated bus bar, 415 V, double door type having housing and including MCCB 4 pole 40 Amp, 16kA.
MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp complete all as specified.
MCCB 4 pole 63 Amp, 16kA with enclosure complete all as specified..
Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI wire 4 mm dia (upto the cross arms) by means of GI bolts/nuts/washers, protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI light grade pipe for watering and including funnel, wire mesh, factory made PCC earthing pit chamber & cover including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of MES Schedule Part – I. NOTE:- (i) Factory made PCC pit chamber shall be provided at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.
Environment friendly, modern design, energy saving surface mounted, decorative 10 W bulk head LED luminaire with premium quality diffuser for glarefree light, 6000K, including making connections, complete. MAKE: Havells Cat No. HEXAFT10WLED857SSYMBOPC or equivalent in makes mentioned in Appendix 'B' here-in-after.
Surface mounted environment friendly LED 10 W batten with polycarbonate housing & integrated electronic driver, lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat No. LUMILINEBS10WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
Surface mounted environment friendly with eye soft technology & glarefree diffuser LED 20 W lighting , 6500K, lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat No. ENDURALINEARNEOBS20WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
Ceiling fan 1200 mm sweep, 230 V with blades & down rod, minimum air delivery 210 CFM with service value 6.00 BEE, five star rated, brushless direct current motor (BLDC) and connecting up from ceiling rose or connector to fan, complete all as specified. MAKE: Havells Cat No. FHCEO5SWHT48 or equivalent in makes mentioned in Appendix 'B' here-in-after.
Clean dry sand ( locally available) as cushioning for under ground cable 230 mm thick (one layer of 80 mm thickness before laying the cable and other layer of 150 mm thickness after laying the cable) complete all as specified. NOTE:- Punned down thickness (over all 180 mm) shall be considered for measurement and payment.
Bricks as specified in PS clause 5.1, laid flat and dry in trenches over the cable for protection as length perpendicular to the direction of cable adjacent to each other complete, all as specified.
Steel tubes 40 mm bore ‘light grade’, galvanized with all fittings and fixed to poles/ walls/ under floors/ under road etc complete all as speciifed.
Supply, laying, jointing & testing of LT XLPE insulated cable screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor conforming to IS-7098 (Part-I -1988) laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing complete all as specified of sectional area 35 Sq. mm, 4 core.
Boring holes under road pavement / hardstanding by trenchless technology using ultrasound technique and necessary machine for inserting & including 80-100 mm bore HDPE pipe complete, all as specified.
M/s Sahib and Company
M/S GURBACHAN SINGH
AAR KAY BEE ENTERPRISES
N S ENGINEERS
siddharthenterprises
MALHOTRA AND ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .