Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹5.2 Cr
EMD Value
₹10.4 L
Closing Date
6 Mar 2026, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Executive Officer, WBSAMB
729 Anandapur P.O and P.S Anandapur Kolkata 700 107 West Bengal
Construction of G PLUS 3 Market Complex with allied works at Temathani under Paschim Medinipur District.
2026_WBSMB_998679_1
WBSAMB / CEO / 42 / 2025 - 26
Open Tender
CIVIL AND ELECTRICAL WORKS
Percentage
548 days
Paschim Medinipur Zilla RMC
Please refer Tender documents.
5 documents required · 5 mandatory
₹15,000
₹10.4 L
Yes
West Bengal State Agricultural Marketing Board
3 Feb 2026
3 Feb 2026
10 Mar 2026
3 Feb 2026
6 Mar 2026
11 Feb 2026
10 Feb 2026
CIVIL WORK
Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary). (Payment to be made on area cleared)
Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof.
DismantlingR.C. floor,roof,beamsetc. Including cutting rods and removing rubbish as directed withinaleadof75m. includingstackingof steel bars. (a) In ground floor including roof.
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Providing Bored Cast-in-situ M30 (Batch Mixed concrete with approved concrete pump) grade R.C.C. pile in position as per specifications in all kinds of soil including cost of boring using drilling mud to stabilize the bore and flushing the bore of excess mud with freshly prepared drilling fluid by using pumps prior to placing concrete by tremie pipe in one continuous operation and including the cost of all materials and labour for placing of concrete and also including the cost of mobilization and hire charges of all equipment necessary for boring, welding of reinforcement cage as necessary and lowering of reinforcement cage, preparation and placing of concrete, including the cost of concrete but excluding the cost of reinforcement and labour for bending binding etc. complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m. Work to be executed as per IS: 2911 (Part II Sec 2). (b) Using Tripod. ii) Pile diameter -500 mm.
Performing Vertical load test on single Pile in accordance with IS:2911(Part-IV) by hydraulic jacks on pile/piles with 1.5 times the design load including preparation of the head of piles with concrete of required strength for receiving the jacks with all ancillary arrangements for setting up gauges,construction of suitable platforms, keeping the loads and dismantling and removing all arrangement etc. complete as per IS specification and direction of Engineer-in-chargeconformity of Municipal Corporation Rules using tanker including loading and unloading the same with pump, clearing the site complete in all respect as per direction of the Engineer-in-charge. i) Testing load up to 100 T.
Performing Lateral load test on two piles or two groups of piles by introducing a hydraulic jack with gauge between two piles or pile groups under test by applying horizontal loads in increments of about 20% of the estimated safe load at each stage andapplying the next increment after the rate of displacement is nearer to 0.1 mm. per 30 minutes till the total displacement becomes, 12 mm at the cutoff level including the cost of arranging the entire set-up, hire charges of all implements including atleast two dial gauges, preparing the pile head ifnecessary, and removal of all arrangement after completion etc. complete in all respect includingcost of carriage of all materials and as per IS specification and direction of Engineer-in-charge.
Integrity testing of Pile using Low Strain / Sonic Integrity Test / Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerized equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-incharge. b) For Rest of South Zone & West Zone
Removal of mud/sludge/slurry/liquid earth obtained during piling work from the working site and disposal of the same beyond the KMC/Municipal or any suitable area with conformity of Municipal Corporation Rules using tanker including loading and unloading the same with pump, clearing the site complete in all respect as per direction of the Engineer-in-charge. 500 mm dia Pile
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
Earth work in filling in foundation trenches or plinthwith good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.
(c) Anti termite treatment to the top surfaceof the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates(1%concentration)withwaterbyweight at he rate of 5 Litres per sq.m.of the surface before sand bed or sub-grade is laid.Holes upto 50mm. to 75mm. deep at 150mm. centre to centre both ways shall be made with 12mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion.The work shall be carried out as per specification described inpara 6.4 of code IS 6313 (part-II)1981. (Mode of measurment will be per Sq.m of plan area of plinth treated.)
(A)Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to bemade onmeasurement of finished quantity)
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
(I) Cement concrete with graded stone ballast (20 mm size excluding shuttering)/In ground floor (A) [Pakur Variety]/(a) 1:3:6 proportion
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 320 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 30 Grade (i) Pakur Variety. In Ground Floor.
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 320 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade (i) Pakur Variety. In Ground Floor.
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 320 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade (i) Pakur Variety. In First Floor.
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 320 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade (i) Pakur Variety. In 2nd Floor.
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 320 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade (i) Pakur Variety. In 3rd Floor.
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 320 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade (i) Pakur Variety. In 4th Floor.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.a). (i) Tor steel/Mild Steel. For works in foundation and upto roof of ground floor/upto 4 m - (I. SAIL/ TATA/RINL)
a) For works in First Floor Level
a) For works in Second Floor Level
a) For works in Third Floor Level
a) For works in Fourth Floor Level
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. c)Steel shuttering or 9to12 mm thick approved quality ply board shuttering in any concrete work. (upto ground floor)
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. c)Steel shuttering or 9to12 mm thick approved quality ply board shuttering in any concrete work. ( 1st floor Level)
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. c)Steel shuttering or 9to12 mm thick approved quality ply board shuttering in any concrete work. ( 2nd floor Level)
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. c)Steel shuttering or 9to12 mm thick approved quality ply board shuttering in any concrete work. ( 3rd floor Level)
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. c)Steel shuttering or 9to12 mm thick approved quality ply board shuttering in any concrete work. ( 4th floor Level)
Brick work with 1st class bricks in cement mortar (1:6). (a) In foundation and plinth
Brick work with 1st class bricks in cement mortar (1:6). (b) In superstructure, ground floor
Brick work with 1st class bricks in cement mortar (1:6). (b) In superstructure, 1st Floor
Brick work with 1st class bricks in cement mortar (1:6). (b) In superstructure, 2nd Floor
Brick work with 1st class bricks in cement mortar (1:6). (b) In superstructure, 3rd Floor
Brick work with 1st class bricks in cement mortar (1:6). (b) In superstructure, 4th Floor
125mm. Thick brick work with1st class bricks in cemen tmortar (1:4) in Ground floor.
125mm. Thick brick work with1st class bricks in cemen tmortar (1:4) in 1st floor.
125mm. Thick brick work with1st class bricks in cemen tmortar (1:4) in 2nd floor.
125mm. Thick brick work with1st class bricks in cemen tmortar (1:4) in 3rd floor.
125mm. Thick brick work with1st class bricks in cemen tmortar (1:4) in 4th floor.
Labour for Chipping of concrete surface before taking up Plastering work.
b) Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties bymixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 20 mm th.Plaster with 1:6 Cement morter i) Ground Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 20 mm th.Plaster with 1:6 Cement morter i) 1st Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 20 mm th.Plaster with 1:6 Cement morter i) 2nd Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 20 mm th.Plaster with 1:6 Cement morter i) 3rd Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 20 mm th.Plaster with 1:6 Cement morter i) 4th Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 15 mm th.Plaster with 1:6 Cement morter i) Ground Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 15 mm th.Plaster with 1:6 Cement morter i) 1st Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 15 mm th.Plaster with 1:6 Cement morter i) 2nd Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 15 mm th.Plaster with 1:6 Cement morter i) 3rd Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 15 mm th.Plaster with 1:6 Cement morter i) 4th Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 10 mm th.Plaster with 1:4 Cement morter i) Ground Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 10 mm th.Plaster with 1:4 Cement morter i) 1st Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 10 mm th.Plaster with 1:4 Cement morter i) 2nd Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 10 mm th.Plaster with 1:4 Cement morter i) 3rd Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 10 mm th.Plaster with 1:4 Cement morter i) 4th Floor
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc.
Artificial stone in floor, dado, staircase etc. with cement Concrete (4:2:1) with stone chips ,laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (2:1) including smooth finishing and rounding off corners and including application of cement slurry before flooring woks, using cement @ 1.75 Kg./sq.m. all complete including all materials and labour. In ground floor 35mm. thick.,3 mm. thick topping with ordinary cement
18mm. to22mm. thick, kota stone slab set in 20mm thick (avg) cemen tmortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer-in-charge to match with the existing work. [Slurry for bedding @ 4.4kg/Sq.mandpointing @ 2.0 kg/Sq.m] For Ground Floor .
18mm. to22mm. thick, kota stone slab set in 20mm thick (avg) cemen tmortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer-in-charge to match with the existing work. [Slurry for bedding @ 4.4kg/Sq.mandpointing @ 2.0 kg/Sq.m] For 1st Floor .
18mm. to22mm. thick, kota stone slab set in 20mm thick (avg) cemen tmortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer-in-charge to match with the existing work. [Slurry for bedding @ 4.4kg/Sq.mandpointing @ 2.0 kg/Sq.m] For 2nd Floor.
18mm. to22mm. thick, kota stone slab set in 20mm thick (avg) cemen tmortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer-in-charge to match with the existing work. [Slurry for bedding @ 4.4kg/Sq.mandpointing @ 2.0 kg/Sq.m] For 3rd Floor .
Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Kota Stone.
Extra cost of labour for grinding Kota Stone Floor in treads and riser of Steps.
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide of required to match colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor. With Sand Cement Morter (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 kg/Sq.m & joint filling using white cement slurry @ 0.20 kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m .ii) Other than Coloured decorative including white.
For 2nd Floor
For 3rd Floor
For 4th Floor
(B) Wall With Sand Cement Morter (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 kg/Sq.m & joint filling using white cement slurry @ 0.20 kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m. ii) Other than Coloured decorative including white.
For 2nd Floor
For 3rd Floor
For 4th Floor
Supplying and laying true to line and level vitrified tiles of approved brand (sizenot less than 600mm X600mm X10 mm thick) in floor, skirting etc. set in 20mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using [email protected]./sq Morusing polymerised adhesive (6mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurryusing1.75Kgof cement per sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colourof tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e) I (I) With application slurry @1.75kg/ Sq.m, 20mm sand cement mortar(1:4) & 2mm thick cement slurry at backside of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (A) Deep Colour & White. 1st Floor
2nd Floor
3rd Floor
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) Ground Floor
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) For 1st Floor
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) For 2nd Floor
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) For 3rd Floor
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) For 4th Floor
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. For Ground Floor
For 1st Floor
For 2nd Floor
For 3rd Floor
For 4th Floor
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (InteriorGrade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx).
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 16 Kg./sq.mtr and above. For Ground Floor
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 16 Kg./sq.mtr and above. For 1st Floor
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 16 Kg./sq.mtr and above. For 2nd Floor
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 16 Kg./sq.mtr and above. For 3rd Floor
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 16 Kg./sq.mtr and above. For 4th Floor
Supplying solid flush type doors of deluxe decorative (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings (a) 35 mm thick shutter,Single Leaf. Ground Floor.
1st Floor
2nd Floor
3rd Floor
4th Floor
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal Malayasian Ground Floor.
1st Floor
2ndFloor
3rd Floor
4th Floor
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.. (i) 66mm x 90mm
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. For 1st Floor
2nd Floor
3rd Floor
4th Floor
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)
Iron butt hinges of approved quality fitted and fixed with steel screws,with ISI mark. (v) 75mm. X 60mm. X 3.15mm. ( or Oxidised Fittings))
(i) Door stopper.(Brass)
ii) Godrej Hydraulic door closer fitted and fixed complete. (b) Medium type for Flush Door
(a) Supplying 'Godrej' mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete.
Anodised aluminium barrel/tower/socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws : (ix) 300 mm. long x 10 mm. dia bolt
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in- charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1956 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. I) For structural members of specified sections weighing less than 22.5 Kg./m In 7th floor
Providing and fixing of factory made uPVC Sliding window (White Colour) complete, (U value=1.9-1.3 W/m2 K, flame resistant, self extinguishing, lead free) comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (±0.2 mm) duly reinforced with G.I. section 1.6 mm (±0.2 mm), wherever required. All corners of frame and sash will be fusion welded. After placing 5 mm Clear Annealed glass in the sash, uPVC glazing bead, interlock, EPDM gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window frame will be fixed to the wall with 100mm long and 8mm dia. Fasteners and after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size, of approved quality complete in all respect as per as per approved drawing & direction of Engineer-In-Charge. (Note: Profile manufacturer & Window Manufacturer must be one & same, Only manufacturer Waranty is aceptable) a) 2 Track 2 Sash window frame of size 67 x 54 mm & Sash of size 64 x 47 mm both having wall thickness of 2.3 ± 0.2 mm
Anodised Aluminium D-Type handle of apprv. Brand etc. (a) With Continious Base Plate. (vi) 150 mmx10 mm dia rod.
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. i) ii) 4mm thick coloured / tinted / smoke glass.
Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G. of approvd type, steel latche section 75 mm. wide, fitted with coilwas spring to necessitate the fitting of required no. of C.I.pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially built up side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
b)Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand includings mootheningsurfacebysandpaperingetc. including using of approved putty etc. on the surface, if necessary : (iv) Two coats (with any shade except white)
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly,complete as permanufacturer's specification and as per direction of the EIC. (b) Two Coats . i) Water based interior grade Acrylic Primer
Acrylic Distemper to interior wall,ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats
Applying exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface thoroughly.complete as per manufacture,s specifications and as per direction of the E.I.C. (a) Two Coat Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality as per manufacture,s specification and as per direction of the E.I.C to be applied over acrylic primer as required The rate includes cost of materials,labour,scaffolding and all incidental charges but excluding the cost of primer.In ground floor Two coats (a)Nomal Acrylic Emulsion. Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
Supplying profiles of required section made of Aluminium Alloy Extrusion conforming to IS: 732-1983 and IS: 1285-1975; Anodised with required film thickness and specified colour/natural matt finished conforming to IS:1868-1983for fabrication of Structural Glazing, Curtain Wall formed of basic sections of any ISI embossed/certified make and brand as per direction of Engineer-in-charge. ( Payment will be made on finished length of the work). 15 micron colour anodising Structural glazing /Curtain Wall Mulion & Transom (Weight @1.819 Kg per Meter)
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; (A) clear, toughened glass conforming to IS: 2553-1992 (part-II) (B) coloured, toughened glass conforming to IS: 2553-1992 (part-II) (iii) 10mm thick
Labour charge for fabrication and installation of structural Glazing/Curtain Wall made from annodized extruded allooy aluminium sections for the following units: Structural Glazingmade of extruded and annodized alloy aluminium sections, fabrications including cutting to proper shape and size,drilling including cost of brackets, fastenerbolt, mullionbolt, nuts& washers, maskin tape, double side adhesieve crosslink foam(used for guard of glazed siliconon sub-frame), tissue paper foam(usedas fillerbetween sub-frame and under backing of weather silicon), screws and other necessary hardwares, fixing of glass as per drawing, specification and direction of Engineer-in-Charge. (The rate includes hire charges of all tools and plants, including all incidental charges,adhesieve, joinerssuch as screw, cleateangle,etc. but excluded thecost of extrudedaluminium sections, glass, glazed silicon, weather silicon etc.)
Supplying, fitting and fixing in position C.I. manhole/ pit cover with rim. a) Round. iii) 450 mm X 100 mm X 50 kg (approx.)
Supplying fitting fixing UPVC pipes A-type & fittings confirming to IS :13592-1992 with all necessary clamps nails inc making holes in walls floor etc. cutting trenches in any soil through masionary concrete structures etc if necessary mending good damages including joining with jointing materials concrete UPVC pipes (160mm) dia
a) Plain Tee. (iii) 160 mm. Dia.
c) Bend 87.5 degree. (iii) 160 mm. Dia.
d) Shoe (iii) 160 mm. Dia.
Supplying, fitting and fixing shower rose of approved brand and make. (ii) Chromium plated round shower with revolving joint (Equivalent to Code No. 541(N) & Model- Tropical / Sumthing Special of ESSCO or similar brand).
Supplying, fitting and fixing Peet's valve fullway gunmetal standard. (iii) 65 mm dia
(iv) 50 mm dia
(v) 40 mm dia
(vii) 25 mm dia
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, 65 mm Dia.
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work 65 mm Dia
50 mm Dia
40 mm Dia
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (b) For Concealed Work 25 mm Dia
20 mm Dia
15 mm Dia
(a) (ii) Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special ofESSCO or similar brand)
(b) (ii) Chromium plated Concealed Stop Cock (Equivalent to Code No. 514(A) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
(b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar).
Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model Florentine of Jaquar or similar brand).
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. (iii) 630 mm X 450 mm size
Suppling, fitting and fixing WALL HUNG TYPE water closet (European type) size -500 x 360 x 350 mm of white glazed vitreous chinaware of approved make and brand in position complete with necessary nut and boalts (MODEL CARAT of CERA or equivalent.)
Supplying, fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (iii) 600 mm long
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 (a) 75 mm dia. (internal)
(b) 110 mm dia. (internal)
(c) 160 mm dia. (internal)
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (v) Double Socketed 1.2 Meter Length 3 Meter Length (ii) 110 mm dia. (internal)
x) Bend 87.5º (a) 75 mm
xxviii) Reducing Tee (160 X 110 mm) 75 mm
xx) 125/110 P Trap with W.C. Ring
(xi) Door Bend (T.S.) (b) 110 mm
(xi) Door Bend (T.S.) (c) 160 mm
xviii) W.C. Connector (450 mm long) W / lipring
xv) Vent Cowl (c) 160 mm
(iii) Door Tee (b) 110 mm
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary etc. Above Ground 110 mm. dia
Above Ground 160 mm. dia
Under Ground 110 mm. dia
Under Ground 160 mm. dia
e) (ii) CP Wall Mixture without spout but with provision for connnection to Telephone Shower and exposed pipe for Overhead shower (Equivalent to Code No. 5215 & Model - FLORENTINE of JAQUAR or similar brand).
Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (b) Sink with drain board 1050 mm X 450 mm X 180 mm
Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges. (ii) 600 mm X 450 mm
Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass (ii)25mm dia. and 600mm long
Supplying, fitting and fixing 18 mm thick marble partition slab with chawk doongri marbel square cut, both sides polished with two front corners rounded and edges polished.
Supplying, fitting and fixing C.I. round grating. (i) 100 mm
Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. i) C.P. Flush Pipe
Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. (iii) 900 mm long.
(f) Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model ALLIED of Jaquar or similar).
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (h) 5000 litre capacity.
Labour for hoisting plastic water storage tank. (ii) Above 1500 litre upto 5000 litre capacity. (a) Upto 7th story from G.L.
Constructing Inspection pit of inside measurement 600 x 600 mm x upto 600 mm. (depth) with 250 mm. thick 1st class brick work in cement mortar (4:1) on all sides, bottom of the pit consisting of 100 mm. thick cement concrete (6:3:1) with Stone chips over a layer of jhama brick flat soling 15 mm. thick (4:1) cement plaster to inside walls and outside walls upto G.L. and 20 mm. thick (4:1) plaster to bottom of the pit, providing necessary invert with cement concrete (6:3:1) with Stone chips as per direction, neat cement finishing to entire internal surfaces, top of hte pit covered with 100 mm. thick R.C.C. Slab (3:1.5:1) with stone chips and necessary reinforcements upto 1% and shuttering including 10 mm. thick cement plaster (4:1) in all external surfaces of the slab and one 560 mm. dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earth work in excavation in all sorts of soil , filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With pakur variety. Varity (JSW/JSPL/SHYAM/SRMB/BMASL/UEL/ ECTROSSTEEL/SSL)
Construction of Septic tank of different capacities as per approved drawing awith 1st class brick work in cement mortar (4:1) including two 560 mm. dia. R.C.C. manhole cover of approved make supplied , fitted and fixed in the 100 mm thick R.C.C. (1:1.5:3) top slab with necessary fittings, 20 mm. thick cement plaster (4:1) with neat cement finish tot he internal surfaces and 15 mm. thick cement plaster (4:1) to outside wall upto 200 mm. below G.L. floor finished with 25 mm. thick grey artificial stone 100 mm thick R.C.C. (1:1.5:3) bottem slab including supplying, fitting and fixing all necessary specials, fittings, S.W. tees, C.I. foot rest etc. including excavating earth in all sorts of soil, shoring, bailing and pumping out water as necessary, ramming,dressing the bed and refilling the sides of the tank with earth,removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes,joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 5% by weight of cement with all costs of labour and materials. (iii) For 50 users A) With Pakur variety. (Other than SAIL/TATA/RINL) i) With pakur variety.
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (4:1) band all round and cement brick work (4:1) upto 0.90 metre from top with 20 mm thick cement plastering (4:1) to inside face upto the depth of cement brick work, 15 mm thick cement plaster (4:1) on outer face from top of the well upto G.L. and 10 mm thick cement plaster (4:1) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement concrete (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. (a) With 250 mm thick dry brick work and 250 mm thick cement brick work (6:1) and 1.00 m.inside dia. (Other than SAIL/TATA/RINL)
Supplying,fitting and fixing in position R.C.C. Manhole/pit cover of approved make with rim of approved make (Heavy type). (ii) 560 mm dia.
Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approvedquality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary under lay complete in all respect with all labour and material. [Border concrete if necessary to be paid separately]. Note: Sub-grade CBR should not be less than 5. (c) 60 mm thick interlocking designer concrete paver block M 35 grade for light-traffic zone,commercial & office complex,tourist resort as per IS:15658- 2006 (over20-40mm medium sand bed on 250mm thk WBM/WMM basecourse & 250 mm thk bound gnaular /granular sub-base course including cost of sand for sand bed but excluding cost of base ,sub-base course & subgrade preparation.) (ii) Coloured Decorative
Providing & fixing Concrete Sign Board as per IRC specification of size 900 x 750 x 37 mm. thick made with RCC 1:1½:3 with pakur variety stone chips reinforced with double layer IRC febric (75 x 75 mm. mesh) and fixed with necessary nuts & bolts on two RC precast posts 100 mm. x 150 mm. of height 2.65 m. of which top 750 mm. is of section 100 x 13 mm. and 1.90 metre above GL & 0.75 metre below GL including digging hole, repacking the same with cement concrete 1:3:6 with jhama khoa or with local stone chips etc. complete including painting two coats on both faces lettering sign marks etc. as per direction of the Engineer-in-Charge. (The rate is inclusive of cost of reinforcement, concrete, shuttering, nuts & bolts, washer etc. complete.)
ELECTRICAL WORK
Supplying and fixing 415V, 250A TPN SFU with steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make -L&T or equivalent)
Supplying & fixing 4 bars 415 V, 315 A Busbar chambers (4 x40x5mm) sheet metal (16 SWG) Iron Clad. Dimension of Sheet Metal Box 500x150mm Cu. bars on angle iron frame on wall, incl.earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991)
Supplying & fixing 4 bars 415 V, 100 A Busbar chambers (4 x15x3mm) sheet metal (16 SWG) Iron Clad. Dimension of Sheet Metal Box 500x150mm Cu. bars on angle iron frame on wall, incl.earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991)
Supply of following size L.T. cable, working voltage 1.1 KV grade, heavy duty XLPE insulated, armoured, screened, stranded, Al distribution power conductor cable. 4C, 16 sqmm.
4C, 25 sqmm.
3.5C, 70 sqmm.
3.5C, 150 sqmm.
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (40-63)A, 415V, FP MCB
(6-32)A, 240V, SP MCB
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA / 35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. 63A
Supplying and fixing MCCB SS enclosure with IP-20/30 protection, pwder coated provision for housing Four pole (4P) MCCB, concealed in wall after cutting the wall & mending good the damages to original finish / on flat iron frame incl. painting, connection & provision for earthing attachment
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 4 way
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Up to 160A. 4 way
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+4 way
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. 2 Way
Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and necessary conection.
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. 32A, 240V, DP
Supplying and fixing 415V, TPN on load front operated Change over switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc. 160A, 415V, FP
Fixing only starters (for motor control) on flat iron frame / angle iron frame on wall. On angle iron frame (for higher rating)
Laying of cable upto 3/4 core 25 sqmm on wall / surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Laying of cable above 3½ core 50 sqmm and upto 3½ core 95 sqmm on wall / surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall / surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE / PVC armoured cables as below : For 4 core upto 16 sqmm
upto 25 sqmm
For 3½ core upto 70 sqmm
upto 150 sqmm
Finishing the end of following XLPE / PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 4 core 16 sqmm cable
4 core 25 sqmm cable
3½ core 70 sqmm cable
3½ core 150 sqmm cable
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. 100 mm dia
Fixing only bulk head ceiling fitting on wall / ceiling by screws etc.
Fixing only single / twin florescent light fitting complete with all accessories Directly on wall / ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) (Considered for chandelie)
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 23 cm (9")
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long). For Al. 23 cm Exhaust fan (9")
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC - [ DB to 16A Socket Point etc. ]
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Brand approved by EIC) fixed on Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish . Average run 8 mtr.
Average run 12 mtr.
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V+C18 5A 3 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switc board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish.On Board.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
Supply of 20 watt ECO Compact industrial batten suitable for single T8 LED tube.Model No.DIJB12LT8-20.Make- Crompton or equivalent
Supply of 20 watt ULTRON LED polycarbonate T8 tube with in built driver and metal heat sink. Efficacy of 100 Lumens/W.Model No.LT8-20-865-(2) .Make- Crompton or equivalent
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
Supply of 10 watt LED ADORE 2 star Lamp. Model No-LHLDEUEEML8R010. Make- Crompton or equivalent
Supply, Installation, Testing & commissioning of 2 H.P. submersible motor pump set including flat cable for office building purpose having capacity of 20 L / min - 100 L / min dischage (Lump Sum). Model no-CORA 1C/50G+UMAI100-1.5/22 1.5 SQMM.Make- KSB or equivalent reputed brand.
Supplying of max. motor Output for 2 HP, 1.5 KW DOL Starter.
Fixing only starter (for motor control ) on angle iron frame on wall ,Direct on line Satrter for motor up to 5 HP
Supply of 12 Watt PEARL NIOS - R Round surface mounted LED panel. PDC aluminum housing and high translucent frosted plastic diffuser makes it a robust Luminaire. Efficacy 100lm/w Model No. LCDSPLN-R-12-NW
Supply of 240V 300 mm(1400 RPM) heavy duty exhaust fan. Color-Grey) (Make: Orient )
Excavation of soil for installation of Earth Electrode and filling & ramming. For Morrum Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm diax 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below : By TATA-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall / floor with staples buried inside wall / floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. Solid GI wire. No. 8 SWG
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall / floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1)
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation of overhead reservoir (vertical run)
Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc.
Supply, Installation & Commissioning 9.90 Kw Roof Top On Grid Solar System with poly crystaline modules, 330 wp Solar PV modules - 30 Nos (Make-Tata Power Solar), AJB, 2 I/P 2 O/P, with Fuse, SPD Type-II -1 No.(Make-Trinity/Hensel/Eligent/TPS), Grid Connected Solar Inverter (1X5 Kw, 415 V AC 50 Hz MPPT) DC:AC=1:3 max -1 no.(Make-Growatt/Goodwe/Powerone), Dongle GPRS (wifi enable)- 1 set(Make-ITAPS), ACDB with SPD 3ph -1 set (Make-Eligant/TPS) , Earthing Kit 1.5M,14.2 mm dia, copper B-3 Set,Lightening Arrestor Height 2 Mtrs Conve -1set, Installation Kit (Comm Cable etc)- 1 set including Net metering documentation charges.
Supply , Installation & Commissioning of cumulative roof top of elevated structure for 9.9 Kw for solar power plant
Supplying & fixing ABC Stored Pressure type Fire Extinguisher og 6 kg capacity consisting of welded cylinder squeeze lever discharge valve fitted with pressureindicating guage with internal discharge tube,discharge hose and nozzle,suspension bracket,conforming to IS:15683 duly charged with ISI Market Mono Ammonium Phosphate Base ABC Powder conforming to IS:14609 And pressurized with nitrogen gas. Temparature Range(-)30ºC to (+)55ºC.Fire Rating-2A & 21B. Make- Fireshield or equivalent reputed brand.
Supplying & fixing CO2 type Fire Extinguisher og 4.5 kg capacity conforming to IS:15683:2006 made from seamless cylinder conforming to IS:7285 duly approved by chief controller of Explosive,Nagpur,fitted with ISI Marked Controlled valve conforming to IS:3224,high pressure 1 mtr. long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket suitable for operating between (-)30ºC to (+)55ºC,Fire Rating Class-13B. Make- Fireshield or equivalent reputed brand.
Supply , Installation ,Testing And Commissioning of 8 passengers (544 Kg) capacity Fully Automatic microprocessor based V3F lift for G+3 building with ARD system.Speed. 1 mt/sec. No of Stops & Opening G+3, 3 stops, 3 opening, Power Supply.415 volt A.C 3phase 50 Hz +/- 10% Operation: Simplex full collective control with auto/attendant ,Indicator. Up – Down indication arrows and 7 segments for car and floor Position indicator. Car Enclosure : S.S-304 Sheet with Hair line finish, light fan, & Marble flooring. Car Door SS-304 automatic gates . Fan to be provided in the car. The fan is automatically switched off when there is no call for saving electricity. Car Light Decorative LED light to be provided in the car. The light is Automatically switched off when there is no call for one preset period of time. Make : Engineering Vertical System or Equivalent.
FIRE FIGHTING ARRANGEMENT WORK
FIRE PUMP ROOM EQUIPMENT . FIRE PUMP DRIVEN BY ELECTRICAL MOTOR. SITC of "Electrically Driven Centrifugal Pump" suitable for automatic/manual operation & consist of the following, Horizontal, end suction, high pressure centrifugal pump, suitable for operation on 415 volts ± 6%, 3Phase, 50 Hz A.C supply. Fire pump shall have C.I. casing, CS diffusers, bronze impeller (hard finished and dynamically balanced) and S.S. (304) Shaft with mechanical seal. Horizontal, end suction, high pressure centrifugal pump, suitable for operation on 415 volts ± 6%, 3Phase, 50 Hz A.C supply. Fire pump shall have C.I. casing, CS diffusers, bronze impeller (hard finished and dynamically balanced) and S.S. (304) Shaft with mechanical seal. Squirrel cage induction motor, suitable for operation on 415Volts, 3Phase 50Hz A.C supply for the above pump conforming to IP 55 protection & Class-F insulation. The motor shall conform IS : 1520 with flexible coupling and coupling guard etc. complete as required. Common base plate for pump and motor from M.S. Channel for required size. FIRE HYDRANT/SPRINKLER PUMP :Pump Capacity - 2850 LPM.Pump Head - 70Mtr.RPM - 2900.
FIRE PUMP DRIVEN BY DIESEL ENGINE. SITC of "Diesel Engine Driven Fire Pump" conforming to BS : 649/ IS : 10002/ IS : 1601 & amended upto date & suitable for automatic/manual operation & consist of the following,Horizontal, end suction, high pressure centrifugal pump, suitable for operation on diesel supply. The installation shall be complete with flexible coupling and coupling guard as required. Fire pump shall have C.I. casing, CS diffusers, bronze impeller (hard finished and dynamically balanced) and SS (304) shaft with mechanical seal. The installation shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side.The engine rating shall be suitable to drive the pump at 150% of its rated discharge capacity at least a head of 65% of the rated head. The shut off head should not exceed 120% of rated head. The engine shall have 10% overload capacity for 1-Hour in any period of 12Hrs. continuous run. Heat exchanger cooled (secondary cooling) diesel engine with automatic/ manual starting mechanism and other accessories with fuel tank of 200Liter(fabricated from 3mm MS sheet, painted with two coats of synthetic enamel paint over a coat of primer) of capacity for 8 hours continuous working. The tank shall be fitted with Magnetic oil level indicator, MH with cover, drain valve, air vent including structural supports (painted with approved shade), 1Nos x 12Volt battery, heat exchanger with necessary piping connections & fittings, flexible coupling, coupling guard & exhaust pipe connection complete as required.Common base plate for pump and motor from M.S. Channel for required size. DIESEL PUMP: Pump Capacity - 2850, LPM.RPM - 1500.
JOCKEY PUMP :Pump Capacity - 180 LPM.Pump Head - 70Mtr.RPM - 2900.
MOTOR CONTROL PANEL
SLTC of "1.1kV, LT XLPE(E) Armoured Cable". The rate shall be inclusive of necessary supporting & clamping arrangement for laying of cables within tray/pipe/trench. The installation should confirm to IS: 1255.1983 & amended upto date. 3C X 70Sqmm XLPE Aluminium Cable.
3C X 10Sqmm XLPE Aluminium Cable.
4C X 16Sqmm XLPE Aluminium Cable.
CONTROL CABLE. 10C X 1.5Sqmm XLPE Copper Cable.
3C X 1.5Sqmm XLPE Copper Cable.
XLPE Cable end termination Fire Pump
SITC of heat shrinkbale indoor type "LT Cable End Termination" suitable for the 1.1kV with cable lugs, ferruls, double compression brass cable glands, taping, crimping and armour earthing etc. complete. The installation should confirm to IS : 1255.1983 & amended upto date.3C X 70Sqmm XLPE Cable End Termination.
4C X 16Sqmm XLPE Cable End Termination.
10C X 1.5Sqmm XLPE Cable End Termination.
3C X 1.5Sqmm XLPE Cable End Termination.
CABLE TRAY. Supplying and fixing of perforated G.I.sheet cable tray with necessary angle iron suspension supports, anchor fasteners etc. complete. Maximum height of suspension shall not exceed 500 mm.Size of the tray shall be suitable for laying the above mentioned cables. 300mm wide and 50 mm in depth & 2.5mm thckness
150mm wide and 50 mm in depth & 2.5mm thckness
100mm wide and 50 mm in depth & 2.5mm thckness
SLTC of "MS Black ERW Pipe" shall confirm IS : 1239 up to 150mm dia and IS : 3589 above 150mm Dia. The quoted rate shall also include necessary hanger & clamp support arrangment for fixing on the wall or suspend from the ceiling/truss and painting with single coat of zinc chromate primer & two coats of synthetic enamel paint & welding etc. complete in all respect. 200mm nominal dia
150mm nominal dia
100mm nominal dia
80mm nominal dia
50mm nominal dia
Supplying, installing, testing and commissioning of C.I. Non-return valves as per IS:5312 (PN 16) swing check type with required flanges, nuts, bolts and gaskets etc. complete. 150 mm nominal dia
80 mm nominal dia
50 mm nominal dia
Supply, Erection, Testing and commissioning of C.I.Gate valves as per IS:14846 ( PN 1.0 Rating, for delivery side of the pumps) and rising spindle type with flanges, bolts, nuts, washers, gaskets etc. 150mm nominal dia
100mm nominal dia
80 mm nominal dia (Test Line)
50 mm nominal dia
Supplying, Installing, testing and commissioning CI butterfly valves as per BS 5155 ( PN 16) slim seal standard lever operated type with required flanges, nuts, bolts etc. complete. 150mm nominal dia.
50mm nominal dia
Supplying, installing, testing and commissioning of Gun metal Ball valves with fittings of screwed end type. 15mm dia.
25 mm dia
Supply and installation of Pressure switches of suitable range for pump sets with fittings like unions / collars / reducers etc.
Supply and installation of Pressure gauges of suitable range for pump sets and pipe lines with siphon, fittings like unions / collars / reducers etc. Glycerine filled pressure gauges to use on pump discharge lines.
Exhaust pipe for Diesel engine: Supply, erection, commissioning of additional length of exhaust pipes M.S. Medium grade Class B with mineral wool insulation with aluminum sheet with long radius bend from residential silencer with necessary clamps, fixture. 150 mm dia M.S. Medium grade with mineral wool insulation with aluminum sheeting.
Supply & Fixing of "CI Foot Valve Swing Type" shall confirm IS : 4038, Grade PN-0.2 with srainer, flanges, unions, pad locking arrangement etc. complete. 150 mm Dia.
80 mm Dia.
HYDRANT SYSTEM. SLTC of "MS Black ERW Pipe" shall confirm IS :1239 up to 150mm dia and IS : 3589 above 150mm Dia. The quoted rate shall also include necessary hanger & clamp support arrangment for fixing on the wall or suspend from the ceiling/truss and painting with single coat of zinc chromate primer & two coats of synthetic enamel paint & welding etc. complete in all respect. 150mm nominal dia .
80mm nominal dia
SLTC of "MS Black ERW Pipe" shall confirm IS :1239 up to 150mm dia and IS : 3589 above 150mm Dia. The quoted rate shall also include necessary necessary puddle flanges for tank connection, laying of pipes in excavated trenches, proper supports at bottom. ( Excavation, Foundation & refilling of Civil works)The pipes shall be anti corrosive wrapping treated. Wrapping material shall consist of Wrapping is applied over two coats of anti corrosive rubber modified bituminous primer of density 0.92 gm/cu cm and viscosity of 500 to 1000 cps applied at 150 gms per Sq.M. (under groung piping ). 150mm nominal dia.
80mm nominal dia
Supplying, Installing, testing and commissioning CI butterfly valves as per BS 5155 ( PN 16) slim seal standard lever operated type with required flanges, nuts, bolts etc. complete. 150mm nominal dia
80mm nominal dia
Supplying, erecting and commissioning of YARD/Landing Hydrants comprising of the following in the Fire duct,All the hydrant accessories shall be given serial number for identification,numbers hall be written in the white paint. Supply and Fixing of "63mm dia GM Single Headed Hydrant Valve" with flanged inlet, brass spindle controlled 63mm dia female instantaneous outlet type, G.M. coupling, blank cap, chain, twist release type lug & all accessories shall confirm IS : 5290.
Supply and Fixing of "Fire Hose Cabinet" fabricated from 16G MS sheet with full front glass door and locking arrangement duly painted and suitably mounted on wall for internal or with support arrangement for outdoor as required.
15 M long, 63mm dia RRL hose with instantaneous couplings and Hoses shall be stored in side the hose cabinet with Bracket and required accessories.
1 no. Gun metal short branch pipe of 63 nn dia. with nozzle.
Hose reel drum of swinging type with 19mm dia Rubber braided hose of 40M. length with Gate valve ( upstream) and Shut off nozzle, complete.
Fire duct Shutter fabricated out of M.S.sheet and frame, door shall be 900mm x 1200 mm min. & fixed with 4 mm thick Glass, suitable Rubber beedibg and Locking arrangement. Quoted rate shall be includes all fasteners etc, and complete shutter shall be powder
Supplying, installing and commissioning of fire brigade inlet inlet connection of 4 way with 4 nos. 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arranged on 150 mm dia. Pipe manifold and connected to wet riser main as well as to Fire water tank. Quoted rate shall be included with C.I. Butterfly valve, C.I. Non-return valve and M.S. cabinet of suitable size with mounting supports etc. complete.
Supplying and fixing 2 way Fire Brigade draw off of size 150 mm dia. with 2 No. 63mm (2.1/2") size GM male outlets ( bronze male coupling) including metallic cover of mild steel and glass front, indicator plates,foot valve as directed by Architect etc.complete from tank
Supplying installation testing and commissioning MS Air Release Valve of 25mm dia of approved make on the top of each 150mm dia wet riser as per standard fire practice with necessary cut off & accessories as per instruction and drainage arrangement to release water hammers & air locks
Supplying, installing, testing and commissioning of Gun metal Ball valves with fittings of screwed end type. 25 mm dia.
15 mm dia.
Supply and installation of Pressure gauges of suitable range for pump sets and pipe lines with siphon, fittings like unions / collars / reducers etc. Glycerine filled pressure gauges to use on pump discharge lines.
FIRE EXTINGUISHERS. Supplying, installing and commissioning Portable Fire extinguishers of following type & capacity. ISI marked (IS:15683:2006) Carbon-did- oxide type fire extinguisher of 4.5 kgs. Capacity, CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel, with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket/Floor tralley and suitable sinages etc. complete, confirming to IS: 2878.
ISI marked (IS:15683:2006) Dry chemical powder type fire extinguisher of 6 Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket/Floor tralley and suitable sinages etc. complete, confirming to IS:2171.
Set of 3 fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter "FIRE" in black out side and handle with mounting bracket complete conforming to IS:2546.
Fire bucket stand fabricated by MS angles to install 3 Nos. of buckets.
Supply and installation of RCC hume pipes of 300 mm dia & NP 3 Class with collars for road / below floor crossing of Fire water pipes. The rate shall includes excavation, PAC ( 1:4:8 100 mm thick) bed and ends shall be closed with Brick masonry work as directed by site engineer.
AUTOMATIC SPRINKLER SYSTEM . SLTC of "MS Black ERW Pipe" shall confirm IS :1239 up to 150mm dia and IS : 3589 above 150mm Dia. The quoted rate shall also include necessary hanger & clamp support arrangment for fixing on the wall or suspend from the ceiling/truss and painting with single coat of zinc chromate primer & two coats of synthetic enamel paint & welding etc. complete in all respect. 150mm nominal dia
80mm nominal dia
65mm nominal dia
50mm nominal dia
40mm nominal dia
32mm nominal dia
25mm nominal dia
Supplying, Installing, testing and commissioning CI butterfly valves as per BS 5155 ( PN 16) slim seal standard lever operated type with required flanges, nuts, bolts etc. complete. 150mm dia
80mm dia.
Supplying, installing, testing and commissioning of Gun metal Ball valves with fittings of screwed end type. 25 mm dia.
15 mm dia.
Supplying, installing, testing and commissioning Standard response chromium plated brass Sprinkler with quartzoid bulb,15mm screwed end connection of 68 deg. C. temperature rating and K factor of 80 and orifice shall not be less than 6mm.Sprinklers shall be UL Listed & FM approved. Pendent sprinkler
Wall Mounted sprinkler
Supplying, installing, testing and commissioning of hydraulically operated Sprinkler control valve, with water motor gong bell and trims as required, pressure gauges, drain valves, isolation valves, check valves, strainers etc. complete. Alarm valve shall be UL listed & FM approved. 150mm dia.
Supplying, installing, testing and commissioning flow switch on sprinkler distribution header on each floor and shall be connected to Annunciation panel through cable. Cable / panel shall be measured separately.It shall have UL Listed & FM approved. 80 mm nominal dia.
SITC of "Digital Type Main Flow Indicator Panel" for sprinkler system with ON/OFF (Red/Green) indication lamps for 20Sets of flow meters for sprinkler system including all wiring, connections and control terminals, earthing etc. complete in all respect.
Supplying, drawing, connecting, testing and commissioning of FRLS 2c x 1.5 sq. mm armoured cable, PVC insulated and screened stranded copper wire
Stainless steel corrugated braided flexible pipe(hose) for dropping sprinklers below false ceiling, pipe shall be 16 bar pressure rating and with union / reducer collar, clamps etc. as required.It shall have UL Listed & FM approved. 1500 mm long 25 mm dia.
1000 mm long 25 mm dia
Supply & fixing of approved type rosette plates ( Recessed type, in two piece) for Sprinklers below false ceiling area. The Rosette shall be fabricated by M.S. plate of 2mm thick and the finish shall be powder coated and color shall be as approved by architects / clients.
Supplying installation testing and commissioning MS Air Release Valve of 25mm dia of approved make on the top of each 150mm dia Sprinkler riser as per standard fire practice with necessary cut off & accessories as per instruction and drainage arrangement to release water hammers & air locks
AUTOMATIC FIRE ALARM SYSTEM. SITC of microprocessor based "1-Loop Analogue Addressable Fire Alarm Control Panel" expandable up to 5 loop suitable for connecting multisensing detectors, devices & repeater panels etc. for fire detection and alarm system. All addressable units shall be connected to the FACP through the loop cards and shall be addressed through individualized numbers. The loop length should not be less than 1km & 1no loop having minimum capacity of 125 detectors and 125 devices. The FACP should be compitable with networking devices for interpanel communications with BMS/IBMS. The panel shall have its own battery backup of a minium 48 hours in normal run and half an hour in the alarm condition. The battery shall be of 24V DC and of sealed maintenance free type, housed inside the panel. The rate shall be inclusive of fixing & mounting accessories. Complete installation with main panel, detectors and devices shall be of EN 54, UL, FM, LPCB certified.
SITC of Grade-I "Analogue Addressable Photoelectric & Smoke Combination Detectors" with dual chamber solid state design with indicating lamp, mounting base, built in fault isolation module on false/true ceiling etc. complete. The rate shall be inclusive of fixing & mounting accessories.
SITC of Grade-I "Analogue Addressable Heat Detectors" with solid state design with indicating lamp, mounting base, built in fault isolation module on true ceiling etc. complete. The rate shall be inclusive of fixing & mounting accessories.
SITC of " Analogue Addressable Manual Call Points" with built in fault input/monitor module on wall etc. complete. The rate shall be inclusive of fixing & mounting accessories.
SITC of "Isolator Module" with accessories etc complete.
SITC of " Analogue Addressable Hooter on wall etc. complete. The hooer shall be loop powered only. The rate shall be inclusive of fixing & mounting accessories.
SITC of "Control Control Module" with accessories etc complete.
SITC of "Monitor Module" with accessories etc complete.
Supply & Laying of 1.1KV grade XLPE insulated unarmoured cables in 2.0mm thick UPVC/MS conduits for connecting detectors & devices. The rate shall be inclusive of all fittings, fixing accessories, indentification tags, juntion boxes for incoming & outgoing cables etc. complete. 2C X 1.5Sqmm FRLS Copper Cable.
Supply & Installation of 1.5KVA(865Watt) UPS for 60minutes battery backup for FACP.
WIREMESH TYPE CABLE TRAY. Supply and Erection of following "Wire Mesh Cable Tray". The tray shall be fabricated of pre-galvanised Electro Zinc/Hot Dipped Galvanized/SS 316L/Black Painted shall confirm IEC 61 537 & amended upto date. The rate shall be inclusive of top cover and steel items as required. 150mm wideX50mm depth.
EXIT SIGNAGE Providing & Fixing of "Rechargeable Exit Signage" with inbuilt Ni-Cd rechargeable battery 16 to 24Hrs recharging period & back-up facility.
SAFETY SIGNAGE :Supply and Fixing in position the following type of "Safety Sign Boards" made out of 3mm thick "Opaque" PVC foam board, mirror fasteners etc. complete. Signage printed "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" of 1.25cm height letters in red with white back ground. The size of the board shall be 10" x 12" and shall be fixed at the height of 2mts from finished floor near manual call points.
Floor indentification signage (i.e., GROUND FLOOR, FIRST FLOOR …etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 5cm with contrasting colour from back ground.Size shall be 4"x18".
Fire Exit signage (i.e., "FIRE EXIT") above the door of each stair enclosure on every floor, indicating the direction of exit in case of fire emergency, lettering size shall be 5cm with contrasting colour from back ground.Size shall be 6"x12".
Providing and Fixing in position the signages " FIRE ORDER" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerised cut, PVC Nosn-reflective self adhesive vinyle painted foam board of 2'x3'.
Add GST @ 18 %
Add Labour Welfare Cess @ 1%
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.79 MB
BOQ_2445524.xls
BOQ • 0.82 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .