Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-AOC | L1 | Accepted-AOC Lowest quoted amount overall reasonable | |
| 2 | L2₹33.6 L+₹2.0 L (6.35%)Rejected-AOC | L2 | Rejected-AOC 2nd lowest hence rejected | |
| 3 | L3₹35.5 L+₹3.9 L (12.3%)Rejected-AOC | L3 | Rejected-AOC 3rd lowest hence rejected | |
| 4 | L4₹35.6 L+₹4.0 L (12.7%)Rejected-AOC | L4 | Rejected-AOC 4th lowest hence rejected | |
| 5 | L5₹35.7 L+₹4.1 L (13.1%)Rejected-AOC | L5 | Rejected-AOC 5th lowest hence rejected |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
9 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Belgaum
Garrison Engineer Belgaum Laxmi Tek Camp Belgaum 590009 Karnataka
REPAIRS TO EXTERNAL PLASTERING, FINISHES AND ALLIED WORKS OF CERTAIN BLDGS AT HARDING LINE, NAGZERA LINE, FORT, RA LINE AND QG AREAS UNDER GE BELGAUM
2021_MES_422806_1
GE/ BEL/ OF 2020-2021
Open Tender
Civil Works
Item Rate
270 days
Belgaum
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Belgaum
₹90,000
Yes
17 Mar 2021
16 Feb 2021
11 Mar 2021
17 Feb 2021
9 Mar 2021
17 Feb 2021
60 days
Amount
Taking down chowkhat with shutters (without taking off shutters from the frame) area not exc 1.5 Sqm each all as specified and directed.
Taking down chowkhat with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n exc 4 Sqm each all as specified and directed.
Taking down cement plaster on brick or stone walls, ceilings, etc. including racking out joints hacking for key scrubbing down with water etc., all as specified and directed.
Hacking out old broken glass (any thickness/ size, quality or description) from wooden frames, glazed with putty or fixed with beads all as specified and directed.
M&L for pre-cast cement concrete solid block masonry, exc 10 cm width, blocks cast in PCC 1:3:6, type C0, using 12.5 mm graded stone aggregate and setting in CM 1:6 including demolition of existing masonry and making good disturbed surfaces all as specified and directed.
M&L plain cement concrete 1:3:6, type C-1, using 20mm graded stone aggregate as in coping including use of necessary form work including demolition of existing unserviceable PCC coping of any description and making good the disturbed surfaces all as specified and directed.
Cutting, chases for concealed water tubing and making good in CM 1:3 cutting not exceeding 10 cm girth in PCC block walls/ stone walls all as specified and directed.
M&L for 2nd class hard wood in scantling, clean sawn fixed in unframed work including dismantling of existing unserviceable timber scantling 40 Sq.cm and over in section and in any position in un-framed work and making good disturbed members all as specified and directed.
Dismantling timber scantling 40 Sq.cm and over in section in any position in un-framed work and re-fixing the same in new or old position all as specified and directed.
M&L for 2nd class hard wood plain fillets, rails, posts, rafters, purlins, etc. square, rectangular or triangular in section, wrought, secured with nails or beads; sectional area exc 6 and n.exc 13 Sq.cm including dismantling of existing timber fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section all as specified and directed.
M&L for 2nd class hard wood board, 20mm thick, planned on one side and the other clean sawn, with butt joints and fixed with nails in any situation including dismantling unserviceable boarding of any description and making good disturbed members all as specified and directed.
Dismantling boarding of any description and size, fixed in any position with nails and re-fixing the same in new or old situation, with butt joints and fixed with nails all as specified and directed.
M&L for 2nd class hard wood chowkhat or frames, plain, solid, wrought, framed and rebated on the solid rounded or chamfered, put together with glue pinned at joints, fixed in position all as specified and directed.
M&L for 35 mm thick second class hard wood, Plain framed, panelled shutter (two panel) with lock rail and panel of 12mm thick plywood BWR 9 ply with commercial veneers on both faces with size of rails and stiles sizes of members of shutters as specified in SSR Part I, Section 8. Clause 8.24 (a) and fitted to chowkats all as specified and as directed.
M&L for 35mm thick 2nd class hard wood glazed/ gauged shutters, open rebated and prepared to receive glass, gauze, etc. (divided into square with plain, chamfered or rounded, mitred and rebated sash bars any numbers), edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.24 (a) and fitted to chowkats all as specified and as directed.
M&L for 30mm thick 2nd class hard wood glazed/ gauged window/ ventilator shutters, open rebated and prepared to receive glass, gauze, etc. (divided into square with plain, chamfered or rounded, mitred and rebated sash bars any numbers), edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.24 (b) and fitted to chowkats all as specified and as directed.
M&L for solid PVC Door Frame of size 50mm x 47mm made out of 5mm prelaminated PVC sheet on both sides reinforced with M.S. Square tube, supplying and fixing in opening as per specification and drawing all as specified and as directed.
M&L for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded prelaminated PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and prelaminated PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of prelaminated PVC sheets on both sides to be fitted in the M.S. frame welded / sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawing all as specified and directed
M&L for powder coated aluminium frame work as in doors, partitions and windows using standard aluminium extruded sections (15 micron) including provision of glazing clips, hinges, handles, etc., fixed in repairs, all as specified and as directed. Notes: (i) All the aluminium sections provided under this item shall be measured and converted into weight for payment with the designated unit weight mentioned in the manufacturer's catalogue for the corresponding aluminium sections/ fittings. (ii) The rate quoted deemed to include necessary grouting/ embedding of the aluminium frames/ supports into floors/ walls and making good the disturbed surfaces to match with the existing surfaces and provision of necessary rubber gaskets. (iii) Particle board/ glass panels shall be measured and paid separately.
S&F MS butt hinges 100mm in size, medium weight, cold rolled all as specified and directed.
S&F MS butt hinges 75mm in size, medium weight, cold rolled all as specified and directed.
S&F in repairs 300mm long mild steel helical door spring, ordinary rat tail pattern spring, including roller and roller plate complete fixed to wooden/ steel chowkats all as specified and as directed.
S&F aluminium anodised barrel tower bolt of extruded section, 150mm long all as specified and directed.
S&F aluminium anodised barrel tower bolt of extruded section, 100mm long all as specified and directed.
S&F 100mm long extruded section aluminium alloy anodised handles fabricated type all as specified and directed.
S&F 150 mm long extruded section aluminium alloy anodised handles fabricated type all as specified and directed.
S&F 300mm long aluminium anodised sliding door bolt with hasp, staple (bolt type) and fixing clip of sheet cast or extruded section and fixing bolts plate type with bright bolt not less than 12mm dia all as specified and directed.
S&F 150mm long aluminium anodised hasp and staple, safety type with hinge pin including bolt to hinge plate fixed with screws complete all as specified and as directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire & average width of aperture 1.40mm fixed in panel of joinery with stainless steel wire staples all as specified and directed.
S&F in repairs stainless steel wire cloth 0.36 mm nominal dia of wire & average width of aperture 1.40mm fixed in panel of joinery with stainless steel wire staples all as specified and directed.
M&L for mild steel hold fast and similar small article conforming to Fe-290 Grade-E-165 all as specified and as directed.
M&L for rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters, fixed with angle cleats or other connecting plates conforming to Fe-410-W Gde-E-250 quality-A including dismantling of existing unserviceable mild steel sections of any description and size all as specified and as directed.
M&L for mild steel flats as in wind ties for roof including securing bolts and necessary drilling, conforming to Fe-290 Gde E-165 including dismantling of existing unserviceable mild steel wind ties of any description and size all as specified and as directed.
Dismantling of existing serviceable mild steel wind ties from roof and re-fixing the same including provision of new securing bolts and necessary drilling all as specified and as directed.
S&F mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe-290 Gde- E-165 including dismantling of existing unserviceable mild steel grill work of any description and size all as specified and as directed.
S&F 6mm thick asbestos cement corrugated or semi-corrugated sheets in roofs, walls, etc. fixed with L-type or J-type or cranked hook bolts including dismantling of existing unserviceable AC roofing sheets of any description and size and making good disturbed roof members all as specified and directed.
S&F 6 mm thick asbestos cement two piece adjustable serrated ridge for corrugated sheets in roofs fixed with ‘L’ type or ‘J’ type or cranked hook bolts including dismantling of existing unserviceable AC ridge sheets of any description and size and making good disturbed roof members all as specified and directed
S&F pre-painted galvalume coated high tensile corrugated/ trapezoidal profile steel sheets, AZ-70 coating mass, 550 Mpa yield strength, 0.45mm thick (TCT), as in roofing/ cladding fixed with self drilling fasteners as per manufacturers instructions including dismantling of existing unserviceable corrugated roofing sheets of any description and size and making good disturbed roof members all as specified and as directed. Note: Measurement shall be taken flat as fixed without any allowance for laps, etc.
S&F pre-painted galvalume coated high tensile plain steel sheets, AZ-70 coating mass, 550 Mpa yield strength, 0.45mm thick (TCT), as in ridges, valleys, hips, claddings, etc. fixed with self drilling fasteners as per manufacturers instructions including dismantling of existing unserviceable plain ridges, valleys, hips of any description and size and making good disturbed roof members all as specified and as directed. Note: Measurement shall be taken flat as fixed without any allowance for laps, etc.
S&F PVC (SWR) eaves gutter, half rounded/ square, 150mm bore/ size including all accessories PVC holder bats bolts nuts etc. including taking down existing unserviceable gutters of any description and size and making good disturbed surfaces all as specified and directed.
S&F 110mm bore UPVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/ columns/ pillars/ posts etc. with necessary clamps/ batten holders as in rain water pipes including taking down existing unserviceable rain water pipes of any description and size and making good disturbed surfaces all as specified and directed.
M&L for providing roof treatment with APP modified water proofing membrane with the following specifications all as specified and directed.
Removing existing roof/ chajjas treatment of any type like plastic felt/ HP tiles of any description including taking down existing plastering/ concrete of any thickness and cleaning the top surface of RCC slab with wire brush including removal of debris to a distance exc 50m but n exc 100m
Brushing with neat cement slurry @ 3Kg/Sqm on cleaned RCC slab surfaces and rendering 10 mm thick in CM 1:3 mixed with water proofing compound and finishing surfaces even and smooth without using extra cement. Note: Water proofing compound shall be measured and paid separately
Preparation of plastered surfaces by removing dust, dirt & applying oil bound bituminous primer at 0.3 litre per Sqm & providing APP modified water proofing membrane 4mm thick reinforced with non oven polyester mat weight not less than 160gms per Sqm including min 10cm side/over lap & including applying a coat of blown hot bitumen grade 85/25 over membrane at 1.2kg per Sqm & on drying apply a coat of solar reflective bituminous aluminium paint at 0.1kg/sqm.
NOTE: APP modified water proofing membrane shall be of any one of the approved makes as specified here-in-after and shall conform to specifications given IS 16540-2017/ IS 16532-2017. Contractor shall produce necessary test certificate of the manufacturer to the Engineer-in-charge before incorporation in the work. Necessary independent tests shall also be carried out by the contractor without any extra cost to the Deptt as per relevant IS specifications and membranes with satisfactory test results shall only be incorporated in the work.
M&L for providing sunken floor treatment with APP modified water proofing membrane with the following specifications all as specified and directed.
Removing existing floor treatment of any type and any description including taking down existing plastering of any thickness and cleaning the top surface of RCC slab with wire brush including removal of debris to a distance exc 50m but n exc 100m
Brushing with neat cement slurry @ 3Kg/Sqm on cleaned RCC slab surfaces and rendering 10mm thick in CM 1:3 mixed with water proofing compound and finishing surfaces even and smooth without using extra cement. Note: Water proofing compound shall be measured and paid separately
Preparation of plastered surfaces by removing dust, dirt & applying oil bound bituminous primer at 0.3 litre per Sqm & providing APP modified water proofing membrane reinforced with non oven polyester mat weight not less than 160gms per Sqm including min 10cm side/over lap & including applying a coat of blown hot bitumen grade 85/25 at 1.2kg per Sqm or cold application of bituminous elastomeric coat at 0.70 kg/ sqm
S&F 4mm thick High Pressure Steam Cured (HPSC) non asbestos fibre cement building board in false ceiling with aluminium anodized snap grids of 60x60cm with Tee section 35x25x1.25mm, angle section 25x25x1.25mm thick including 2mm dia GI hanging wire including all hanger fittings etc and applying three coats of white wash on ceiling including dismantling of existing unserviceable false ceiling boards of any description and size alongwith snap grid frame works including making good disturbed wall/ ceiling surfaces all as specified and directed.
M&L for plain cement concrete 1:5:10, type E2, using 40mm graded stone aggregate as in filling under sunken floors all as specified and directed.
M&L for 25mm thick plain cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate as in sub base for flooring including finishing the surface fair and even and demolition of existing cement concrete sub base/ floor of any description and making good the disturbed surfaces all as specified and directed.
M&L for 40mm thick plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in flooring including finishing the surface even and smooth without using extra cement and demolition of existing cement concrete floor of any description and making good the disturbed surfaces all as specified and directed.
M&L for 3mm thick glass dividing strips 38mm wide, inserted in position, conforming to design all as specifiedand as directed.
M&L for coloured vitrified tiles, square or rectangular, light shade, 9 to 10mm thick, area of each tile not exc 0.36 Sqm, as in floors/ skirtings, set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigments to match the shade of the tile laid over and including 15mm thick screed bed in cement mortar 1:4 including dismantling of existing unserviceable tiling alongwith cement mortar bedding (but not backing) and removing rubbish off the premises all as specified and directed.
M&L for coloured non skid ceramic tiles, 7mm thick, area of each tile exc 0.06 Sqm but not exc 0.11 Sqm as in floor, set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigments to match the shade of the tile laid over and including 15mm thick screed bed in cement mortar 1:4 including dismantling of existing unserviceable tiling alongwith cement mortar bedding and removing rubbish off the premises all as specified and directed.
M&L for coloured glazed ceramic tiles 450mm x 300mm x 7 mm thick on vertical surfaces such as skirting, dados etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with surfaces including 10mm thick backing coat in CM 1:4 including dismantling of existing unserviceable tiling alongwith cement mortar plaster and removing rubbish off the premises all as specified and directed.
M&L for plain cement concrete 1:3:6, type C1, using 20 mm graded stone aggregate, 75mm thick as in plinth protection, finishing the surface fair and even, in panels & filling joints with mortar, etc. including demolition of existing plain cement concrete plinth protection of any description and size and making good disturbed surfaces all as specified and directed
M&L for removal of existing vegetations/ trees not exceeding 30cm girth on top/ sides of buildings including digging out roots, pouring sulphuric acid, making good disturbed portions with cement mortar 1:3 and provision of two coats of cement based paint over a coat of primer including necessary preparation of surfaces all as specified and as directed.
M&L for weather proof coating to external wall surfaces with Rain coat with the following specifications all as specified and directed.
The external wall surfaces shall be prepared and made free from all dust, loose particles, laitance and sharp edges, fungus, algae, organic matters, etc. including removal of debris outside of MOD premises
All wide shrinkage cracks shall be cut open and Dr. Fixit crack X paste (for cracks upto 5mm)/ Dr. Fixit crack shrink free paste (for cracks upto 10mm) or equivalent shall be filled in the cracks and finished.
All masonry wall & RCC column separation/ masonry wall & RCC beam separation shall be filled with polymer modified mortar admixed with Dr. Fixit URP or equivalent at the ratio of 1:3 with polymer dosage of 12-20%.
Over the prepared surfaces one primer coat of Dr. Fixit Primeseal acrylic water based penetrating primer or equivalent shall be applied as a bonding coat.
Over the primered surfaces water proof coating shall be applied with two coats of Dr. Fixit Rain Coat or equivalent to form weather proof and decorative coating with 80-100 micron thick and 100% elongation properties.
NOTE: Water proofing chemicals shall be procured from approved manufacturer with prior written approval of GE. Full quantity of fresh chemicals required for incorporating in the work shall be brought to site with sealed containers. Water proofing treatment shall be carried out through authorised applicator of the manufacturer and the contractor shall produce necessary certificate of authentication to the Engineer-in-charge before commence of the work.
M&L for providing water proof treatment to RCC roof with acylic polymer heavy duty fibre reinforced coating with the following specifications all as specified and directed.
The RCC roof surface shall be prepared and made free from all dust, loose particles, laitance and sharp edges, fungus, algae, organic matters, etc. including removal of debris outside of MOD premises
All cracks shall be repaired by cutting 'V' groove along the longitudinal section of cracks and filling with polymer modified mortar admixed with Dr. Fixit Pidicrete URP or equivalent at the ratio of 1:5:15 (URP : Cement :Sand respectively)
All potholes and uneven surfaces shall be repaired with polymer modified mortar over a bonding coat of Dr. Fixit Pidicrete URP or equivalent at the ratio of 1:1 (URP : Cement respectively)
Over the prepared surfaces one priming/ efflorescent coat of Dr. Fixit Primeseal or equivalent shall be applied by diluting the primeseal with water at the ratio of 2:1 (Primer: Water respectively)
Over the primered surfaces water proof coating shall be applied with acylic polymer heavy duty fibre reinforced coating of Dr. Fixit New Coat or equivalent consisting of three coats of application to form 1mm thick heavy duty water proofing coating.
NOTE: Water proofing chemicals shall be procured from approved manufacturer with prior written approval of GE. Full quantitiy of fresh chemicals required for incorporating in the work shall be brought to site with sealed containers. Water proofing treatment shall be carried out through authorised applicator of the manufacturer and the contractor shall produce necessary certificate of authentication to the Engineer-in-charge before commence of the work.
M&L for rendering 5mm thick in cement mortar 1:4 mixed with water proofing compound over 10mm thick backing coat in cement mortar 1:6 on fair faces of brick work or PCC block masonry surfaces finished even and smooth without using extra cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
Supply only integral water proofing compound all as specified and as directed.
M&L for 4mm thick sheet glass ordinary quality and glazing with oil putty/ neoprene rubber gasket in square n. exc. 0.5 sqm in each pane all as specified and directed.
M&L for 5mm thick sheet glass ordinary quality and glazing with oil putty/ neoprene rubber gasket in square n. exc. 0.5 sqm in each pane all as specified and directed.
M&L for 5mm thick sheet glass ordinary quality and glazing with oil putty/ neoprene rubber gasket in square exc. 0.5 sqm in each pane all as specified and directed.
M&L for three coats of white wash on newly plastered surfaces of walls, pilasters, cornices, etc. including necessary preparation of surfaces all as specified and as directed.
M&L for two coats of oil bound distemper (Acrylic distemper washable) on walls, pillasters, cornices, etc., including complete removal of existing treatment and necessary preparation of surfaces with chalk whiting all as specified and as directed.
M&L for two coats of cement based paint, any colour, on newly plastered surfaces of walls, pilasters, cornices, etc., over a coat of alkali resistant primer including necessary preparation of surfaces all as specified and directed.
M&L for two coats of weather proof exterior emulsion on newly plastered surfaces of walls, pillasters, roof projections, facias, drops, chajjas, etc., over a coat of alkai resistant primer including necessary preparation of surfaces by washing, rubbing down and stopping all as specified and as directed.
M&L for two coats of weather proof exterior emulsion on old decorated surfaces of walls, pillasters, roof projections, facias, drops, chajjas, etc., including necessary preparation of surfaces by washing, rubbing down and stopping all as specified and as directed.
M&L for one coat of plastic emulsion paint on old painted walls, pillasters, cornices, etc., including necessary preparation of surfaces all as specified and as directed.
M&L for two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces over 10 cm width or girth including necessary preparation of surfaces all as specified and directed.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint including necessary preparation of surfaces all as specified and as directed.
M&L for one coat of synthetic enamel paint on old painted steel surfaces of any description over 10cm width or girth including necessary preparation of surfaces all as specified and as directed.
M&L for preparation of new steel surfaces of any description n exc 10 cm width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
S&F 15mm bore unplasticised PVC pipes of pressure rating 10kg/cm2, with all fittings, fixed complete to walls, ceilings or laid in floors including taking up or down existing unserviceable GI tubes of any grade and making good disturbed surfaces all as specified and directed.
S&F 20mm bore unplasticised PVC pipes of pressure rating 10kg/cm2, with all fittings, fixed complete to walls, ceilings or laid in floors including taking up or down existing unserviceable GI tubes of any grade and making good disturbed surfaces all as specified and directed.
S&F in repairs 15mm bore bib taps, brass CP, long body, fancy type, screwed for iron pipe or for brass ferrule and fixed all as specified and as directed.
S&F in repairs 15mm bore PTMT bib taps, standard type, (Minimum weight 90gms) any colour, high pressure screwed for iron pipe all as specified and as directed.
S&F in repairs 15mm bore stop valves, cast copper alloy screwed down high pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions all as specified and as directed.
S&F in repairs 15mm bore stop valves, fancy type, brass chromium plated, screwed down high pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions all as specified and as directed.
S&F in repairs 15mm bore stop valves, fancy type brass CP, with long shank and cup (concealed type), screwed down high pressure, screwed both ends for iron pipe for unions all as specified and as directed.
S&F in repairs vitreous china squatting pan, Orissa pattern of size 580 x 440 mm, white, with integral foot rest (excluding flushing cistern) including 'P' or 'S' trap etc complete all as specified and directed.
S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white, including 'P' or 'S' trap, plastic water closet seat of any colour as approved by GE, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device, fixing bolts etc, connecting to drain pipe and flushing pipe including provision of PVC flush pipe complete all as specified and as directed.
S&F in repairs syphonic action type low level PVC flushing cistern, 10 litres capacity, white, with inlet, ball valve, float, handle and flush pipe etc complete all as specified and directed.
S&F in repairs 110mm bore UPVC (SWR) bends any radius all as specified and directed.
M/s. KIRAN M CHOUGULE
SHRI.H.R.PATIL
ASHOK M RAJGOLKAR
M/s. VIJAY ELECTRICALS
N K CONSTRUCTION
M/s B C CHOUGULE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .