| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC 329 COD COLONY KOYLA NAGAR PO KIDWAI NAGAR KANPUR 208011 | KANPUR | KANPUR | UTTAR PRADESH | 208011 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹7.2 L+₹35,070 (5.16%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹7.2 L+₹42,020 (6.18%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹8.0 L+₹1.2 L (17.4%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹8.9 L+₹2.1 L (31.1%)Rejected-Finance BHU | L5 | Rejected-Finance Being L5 |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
14 Dec 2021, 6:00 pmClosed
GE I R and D Kanpur
GE I R and D Kanpur DMSRDE Complex, GT Road Kanpur 208013
REPAIR/REPLACEMENT/MAINTENANCE OF INTERNAL WIRING, DISTRIBUTION BOARDS, SUB MAIN WIRING, TPN/SPN, DBS, EARTHING, SECURITY LIGHT FITTING, MODULAR TYPE ACCESSORIES AND OTHER CONNECTED WORKS ITEMS AT TECHNICAL AREA UNDER GE (I) R and D KANPUR.
2021_MES_488497_1
8257/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE I R and D Kanpur
As Per NIT
8 documents required · 8 mandatory
₹500
GE I R and D Kanpur
₹28,000
Yes
4 Mar 2022
16 Nov 2021
16 Dec 2021
16 Nov 2021
14 Dec 2021
30 Nov 2021
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for point wiring complete with FR PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and including cutting/chasing on brick wall not exc. 10 cm girth (excluding ceiling surface for existing pipe) and supply and fixing concealed PVC conduit pipe medium grade of nominal size 20 mm dia along with connected fittings/junction boxes and sunken terminal boxes pressed MS/GI steel terminal boxes not less than 1.20 mm thick for mounting switch, socket etc including 3 mm thick Hylam brand sunmica laminated sheet cover with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed and suitable for the following: -
i) One light point or one fan point controlled by one way, single pole switch
(ii) One 3 pin socket outlet, 6 Amp on “independent board” but below the switch board of the light point in same vertical plane.
(iii) One 3 pin socket out let, 6 amps on the "same board" with other switches
(iv) One 3 pin socket outlet, 6 Amp on “independent board”
All as per item No. 2 here in above but point wiring using 2.5 Sqmm (Nominal area) FR PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on “independent board”.with 1.5 sqmm with one single run copper wire as continuous earth wire to common earth dolly complete all as specified and directed.
.---do--- item No 3 but One 3/6 pin socket outlet, 6/16 Amp on “independent board” but below/side the switch board of the light point in same vertical plane complete all as specified and directed.
M&L fordrawing the wire in existing conduit steel/PVC complete with point wiring with FR PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and sunken terminal boxes pressed MS/GI steel terminal boxes not less than 1.20 mm thick for mounting switch, socket etc including 3 mm thick Hylam brand sunmica laminated sheet cover with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed and suitable for the following: -
i) One light point or one fan point controlled by one way, single pole switch
(ii) One 3 pin socket outlet, 6 Amp on “independent board” but below/side the switch board of the light point in same vertical plane.
(iii) One 3 pin socket out let, 6 amps on the "same board" with other switches
(iv) One 3 pin socket outlet, 6 Amp on “independent board”
All as per item No. 5 here in above but drawing in existing conduit for point wiring using 2.5 Sqmm (Nominal area) FR PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on “independent board”.with 1.5 sqmm with one single run copper wire as continuous earth wire to common earth dolly complete. Make of wire: Havells/Polycab/Finolex
Supply and fixing switch piano flush button type, 6 Amp one way, 240 Volt, single pole , ISI marked conforming to IS 3854 style double colour series with cover plate complete all as specified and directed. Code No.7001& 7301of make Cona or equivalent of Anchor/SSK/Crabtree or as approved by GE (I).
Supply and fixing socket out let, 2 in 1, 5 pin, 6 Amp, 240 Volt AC, flush type, style double colour series with cover plate complete all as specified and directed. Code No. 7021& 7306 of make Cona or equivalent of Anchor/SSK/Crabtree as approved by GE(I).
Supply and fixing switch socket combination multipurpose 5 in 1, 6 pin, 6 and 16 Amp, 240 Volt AC, style duoble colour series" with cover plate complete all as specified and directed. Code No. 7096 & 7316 of make Cona or equivalent of Anchor/SSK/Crabtree as approved by GE(I).
Supply and fixing FASHION batten/angle holder with colour ring. Code No. 2476/2471 of make Cona or equivalent of Anchor/SSK/Crabtree as approved by GE(I).
Supply and fixing FASHION ceiling rose with colour ring. Code No. 2186 of make Cona or equivalent of Anchor/SSK/Crabtree as approved by GE(I).
Supply and fixing medium step type fan regulator 80 Watt, 240 Volt AC, style double colour series "style medium step" ISI marked complete all as specified and directed. Code No.7066 & 7306 of make Cona or equivalent in Anchor/SSK/Crabtree as approved by GE (I).
Supply and fixing in replacement of old porch/balcony light by energy efficent LED 240 volt, AC Surfae mounted LED downlighter 12 watt, 5700CCT(K) in white colour including driver control etc complete all as directed at site. Make: Philips/Havells/Bajaj/Crompton
Supply and fixing in replacement of Mirror optic fitting by recess/surface mounted mirror optic LED luminaire fitting with paralite P5 louvers, 5700 K, 30 watt LED dimention 2 ft x 2 ft fitting for grid type ceiling including control driver and other accessories complete all as specified and directed. Make: Philips/Havells/Crompton.
Supply and fixing in replacement of old inserviceable security light by energy efficeant LED security light 240 volt AC 30 watt pressure die cast LED street light complete with 25mm dia Light grate GI pipe suitable size incl 3 core FR PVC insulated wire connection from Ceiling rose etc all as directed at site . Make:Philips/Cromton/Bajaj.
Supply and fixing in replacement of Kit Kat DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, confirming to IS 13032 & 8623 complete all as specified and directed. Cat No. Schneider (Electric)/Legrand/L & T/Indoasian .
Supply & Fixing MCB TPN, 100 Amps 415 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make -Schneider Electric/L&T/Legrand/Indoasian.
Supply & Fixing MCB SPN, 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make -Schneider Electric/L&T/Legrand/Indoasian.
Supply and fixing MCB SP, 06 to 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make -Schneider Electric/L&T/Legrand/Indoasian.
Supply and fixing MCB TPN, 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make -Schneider Electric/L&T/Legrand/Indoasian.
Supply and fixing MCB TP, 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make -Schneider Electric/L&T/Legrand/Indoasian.
Supply and fixing in replacement of AC/Geyser box by sheet steel enclosure in single pole and neutral fitted with two pin and earth plug and socket complete with one single pole MCB, 240 volt, 20 Amps , 'C' series of suitable rating complete all as specified and directed . Make -Schneider Electric/L&T/Legrand/Indoasian.
Supply and fixing in replacement of Kit Kat DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way, confirming to IS 13032 & 8623 complete all as specified and directed. Make -Schneider Electric/L&T/Legrand/Indoasian.
Supply & Fixing in replacement of Kit Kat DB by TPN Distribution Box vertical, double door of protection grade IP 43 provn for 4 Pole MCCB frame F2+24 modules upto 250 Amps , upto 50 KA breaking capacity as incomer in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, confirming to IS 13032 & 8623 including chasing/cutting of wall and concealed and making good as existing surface complete all as specified and directed. Make -Schneider Electric/L&T/Legrand/Indoasian.
Supply and fixing in replacement of Kit Kat DB by TPN Distribution Box double door of protection grade IP 43, in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, confirming to IS 13032 & 8623 including chasing/cutting of wall and concealed and making good as existing surface complete all as specified and directed. Make -Schneider Electric/L&T/Legrand/Indoasian.
supply and fixing of MCCB 200 Amps 25 KA with fixed thermal magnetic release frame F2 optim 1.0 , 4pole all as specified and directed.Make -Schneider Electric/L&T/Legrand/Indoasian.
M&L in replacement of worn out sub main of worn out aluminium conductor by sub main wiring with four run of FR PVC insulated unsheathed flexible copper conductor (multistrands) single core of size 10.0 Sqmm 1100 volts grade and two run of 6.0 Sqmm FR PVC insulated unsheathed (in green colour) flexible copper conductor (multistrands) for continuous earthing conforming to IS 694 with latest amendments and ISI marked drawing in PVC rigid conduit and providing flexible conduit at each end point connecting incoming/out going electric connection by using required size copper lugs/thimbles and making good the disturbed surface to match with existing surface complete. Note :- 1. four run of single core cable with two run of contineous earth wire of copper conductor wire flexible (Multistrand) of FR PVC insulated shall be measured and paid as one unit length 2. PVC conduit pipe with fitting shall be measured and paid separately .
M&L in replacement of worn out sub main of worn out aluminium conductor by sub main wiring with four run of FR PVC insulated unsheathed flexible copper conductor (multistrands) single core of size 16.0 Sqmm 1100 volts grade and two run of 10.0 Sqmm FR PVC insulated unsheathed (in green colour) flexible copper conductor (multistrands) for continuous earthing conforming to IS 694 with latest amendments and ISI marked drawing in PVC rigid conduit and providing flexible conduit at each end point connecting incoming/out going electric connection by using required size copper lugs/thimbles and making good the disturbed surface to match with existing surface complete. Note :- 1. four run of single core cable with two run of contineous earth wire of copper conductor wire flexible (Multistrand) of FR PVC insulated shall be measured and paid as one unit length 2. PVC conduit pipe with fitting shall be measured and paid separately .
Supplied and fixing in replacement PVC conduit by Non Metallic Rigid PVC conduit, ISI Marked, conforming to IS 9537, medium grade of size 32 mm dia including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles, pipe hooks etc complete all as specified and directed.
M & L for sub main wiring in replacement of worn out aluminium conductor wire with two run of FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 4.0 Sqmm, 1100 Volts grade and one run of 2.5 Sqmm FR PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and including draw in PVC rigid conduit 25 mm dia , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing colour (distumber, Oil bound, Samosem etc ) complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire flexible (Multistrand) of FR PVC insulated shall be measured and paid as one unit length 2. PVC conduit pipe with fitting shall be measured and paid separately .
M & L for sub main wiring in replacement of worn out aluminium conductor wire with two run of FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6.0 Sqmm, 1100 Volts grade and one run of 4.00 Sqmm FR PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and drawing in PVC rigid conduit , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FR PVC insulated shall be measured and paid as one unit length. 2. PVC conduit pipe with fitting shall be measured and paid separately .
Supplied and fixing in replacement PVC conduit by Non Metallic Rigid PVC conduit, ISI Marked, conforming to IS 9537, medium grade of size 25 mm dia including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including Cutting & Chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and distemper / colour wash etc to match with existing surfaces including facing / finishing complete all as specified and directed.
Supply only LED lamp retrofit 12 Watt, 230 volts,50 HZ,AC supply with base holder B22 white colour with polycarbonate body and aluminium heat sink complet all as specified and directed. Make Philips/Crompton/C&S.
Supply and fixing in replacement of old unserviceable 4 pin tube rod by LED light tube rod for recess mounted batten fitting of wattage 18 watt. Make:Crompton/Philips/WIPRO cat part D611865
Supply and fixing of MCCB Eclosure of Optipro enclosure for frame-1 Optium 4 pole MCCB, "ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make -Schneider Electric/L&T/Legrand/Indoasian.
supply and fixing of MCCB 160 Amps 16 KA with fixed thermal magnetic release frame F1 optim 1.0 , 4pole all as specified and directed.Make -Schneider Electric/L&T/Legrand/Indoasian.
Supply and fixing in replacement of old unserviceable FTL fitting by LED light fitting trend wall mounted batten with extruded aluminum housing with intregated LEd driver with LED tube aluminum extrusion 18 watt complete. Make:CAT PART OF WIPRO : LL20-281-XXX-65AL/Crompton/ Philips/HAVELLS.
Supply and fixing in replacement of old unserviceable Tube rod by LED light tube rod for wall mounted batten with extruded aluminum housing with intregated LEd driver with LED tube aluminum extrusion 20 watt complete. Make: Cat part : LT8-20-865(2) of Crompton/Philips/WIPRO catpart: D612065
NOTE FOR LED LAMP AND LED LIGHT FITTINGS :- GUARANTEE FOR LED LIGHT FITTING AND LED LAMPS :- Contractor shall submit a guarantee of LED lamp and LED light fittings for a period of 02 (Two) years from the date of completion of work. In case any LED lamp and LED light fittings are not found functioning during this period, the same shall be replaced by the contractor without any extra cost to the department. The contractor should furnish a written guarantee for the satisfactory performance of LED lamp and LED light fittings for period of 02 years in favour of GE. The department may hold guarantee money equal to 2.5% of amount quoted against respective items.The contractor shall furnish FDR for said amount in favour of GE (I) R&D Kanpur.
YS CONSTRUCTION
BRIGHT TRADRES
SAKSHAM SUPPLIERS BUILDERS
Lalta Prasad vijay kumar Forwarding Agency
Himanshu Construction and Suppliers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .