Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC | L1 | Accepted-AOC AS L-1 BIDDER | |
| 2 | L2₹12.3 L+₹1.6 L (14.9%)Rejected-Finance 13 SOUTH PURBACHAL HOSPITAL RD CALCUTTA KOLKATA WEST BENGAL 700078 | KOLKATA | WEST BENGAL | 700078 | L2 | Rejected-Finance AS L-2 BIDDER | |
| 3 | Not Admitted-PreQual/Technical | - | Not Admitted-PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-PreQual/Technical 07 SUKHATOLA DUMARI KASIA KUSHINAGAR UTTAR PRADESH 274402 | KUSHI NAGAR | UTTAR PRADESH | 274402 | - | Not Admitted-PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-PreQual/Technical RAJARHAT KALIBARI ROAD NORTH 24 PARGANAS WEST BENGAL 700135 | 24 PARAGANAS NORTH | WEST BENGAL | 700135 | - | Not Admitted-PreQual/Technical Not Complied with technical specification |
Tender Value
₹11.0 L
Closing Date
20 Sept 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI RAHULDEB MUKHOPADHYAY, EE
ENGINEERING SERVICES DEPARTMENT, CSIR-CGCRI, KOLKATA
Electrical modification and renovation work of Computer Division at CSIR-CGCRI, Kolkata.
2021_CSIR_87610_1
GCW/E/06/21-22(W)
Open Tender
Electrical Works
Works
120 days
CSIR-CGCRI
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
CENTRAL GLASS AND CERAMIC RESEARCH INSTITUTE
Exempted
25 Nov 2021
10 Sept 2021
21 Sept 2021
10 Sept 2021
20 Sept 2021
10 Sept 2021
90 days
Amount
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4.0 sq. mm
6 x 4.0 sq. mm
6 x 6.0 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following sizes of double locking PVC casing n caping along with accessories in surface
20 mm x 12 mm
25 mm x 16 mm
50 mm x 16 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Telephone socket outlet
Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
1 or 2 Module
3 Module
4 Module
6 Module
8 Module
12 Module
Supplying and fixing of modular type recess mounted RJ 45 socket outlet with coverplate including connection of CAT VI wire
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.
1 run of cable
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including three way backelite terminal block as required.
75 mm X 75 mm X 60 mm deep
100 mm X 100 mm X 60 mm deep
200 mm X 150 mm X 60 mm deep
Supply of 1.1 KV grade following XLPE insulated multi strand Copper conductor Armoured cable of confirming the IS: 7098 (Part 1) 1988 specification:-
4 Core 16 sq. mm.
4 Core 35 sq.mm.
Supply of 1.1 KV grade following PVC insulated and PVC round sheathed flexible bright copper conductor multi core cable cord of confirming the IS: 694:2010 specification:-
3 Core 1.5 sq.mm.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Finishing of end termination with proper size of pin / ring type copper solderless socket (Heavy duty) by crimping method of following sizes PVC insulated copper conductor
1 x 1.5 sq. mm
1 x 2.5 sq. mm
1 x 4 sq. mm
1 x 6 sq. mm
1 x 16 sq. mm
1 x 35 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 16 sq. mm (28mm)
4 X 35 sq. mm (32mm)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way (4 + 24), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 Way, Double door
Supplying and fixing of following rating, 415 volts, MCB in the existing DB complete with connections, testing and commissioning etc. as required.
63 amps, FP
Supply and fixing of MCCB following encloser box (sheet steel, 2mm /14 SWG) on the wall in surface / conceal fashion including mounting arrangement of MCCB complete in all respects.
For four pole 125/160 DPX MCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
125 Amp, 36 KA FP MCCB
Supply and fixing on wall of 400 mm wall mounted oscillating type cabin fan including connection of the same.
Supply, Installation and fixing of Electrozinc Galvanised(Z+) Wire mesh indoor type cable Tray with wire dia from 3.9 mm including supports from wall / ceiling. It shall be manufactured with a longitudinal 'T'welded safety edge. Trays shall be constructed with 50 mm / 100 mm mesh configuration. Accessories for coupling and making 'T's and bends CE25/CE30 screw based system combination must be used and mounting accessories are required of same finish of same manufacturer as per the site requirement (celing/wall mounted). The deflection of cable tray must be within 1/200-th of the distance between two supports and tested in accordance with the standard IEC 61537. Wire cable trays must be supported with a span of 0.5 mtr. Assembly with fire ressitant properties must have an E30/E90 certificate. The loading capacities of the brackets and the hanger torques must be tested in accordance with the standard IEC 61537. No hot work for trays is allowed at site.
150 mm(W) X 54mm(H) X 3.9mm(Wire Dia)
Supply, Installation and fixing of snap-on / DLP-S PVC trunking with cover for electrical and data cable wiring. The trunking should be provision for fixing modular switch -socket on itself including all fixing accessories for 100x50mm DLP Trunking.
100mm (W) X 50 mm (H) with cover
Base joint
Cover Joint
Variable internal /External Angle (90 degree)
Flat Angle (90 degree)
End Cap
tee junction
Clip-on support for 2 module frame
Clip-on support for 4 module frame
Supply & fixing of of following indoor type LED Light fittings with extra high efficiency 120-150 lumens/watt LEDs including driver and all firtting accessories. The fixture must have of CRI > 80, Colour temperature 6000K/6500K and weather & dust proof. The fitting will be hanging from ceiling by Chain / GI wire with adjusting screw as per site requirement
12 Watt 160 mm dia recess mounted
36 Watt 595 mm x 595 mm recess mounted
20 watt 1195mm batton light Aluminium body
Supply of Wire cutter for wire mesh cable tray
Supplying, Erection, testing and commissioning of floor mounted by Angle structure cubical type factory assembled dust and vermin proof segregated and compartmentalized following L.T. Panels suitable for 440V, 50 Hz, AC, having protection of IP 42 degree and CPRI approved. All dimentions and technical specifications are mentioned in Annexure I. GA and schematic drawing (General notes and legends, SLD, BOM, Control Circuit etc.) to be submitted before fabrication.
UPS cum A.C control Panel (overall dimension in mm W x H x D = 1750 x 1450 +600 Angle structure x 400)
Dismantling and reinstallation of existing Cat 6 cable with re-connection (Aprox -100 nos), Optical Fibre Cable with splicing (aprox- 50 nos) and all necessary work regarding Server, switch, patchpanel etc for relocation of the server room as per site requirement and instruction of engineer-in-charge
scientific refregeration
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .