Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC PLOT NO 783 JAIL ROAD JHARPADA BHUBANESWAR PIN 751006 | KHORDHA | ODISHA | 751006 | ₹36.0 L | L1 | Accepted-AOC First lowest and qualified through transparent lottery system |
| 2 | L1₹36.0 LRejected-AOC PLOT NO 92 DHAGABANPUR PATRAPADA BHUBANESWAR DIST KHURDA | BHUBANESWAR | KHURDA | ODISHA | ₹36.0 L | L1 | Rejected-AOC First lowest |
| 3 | L1₹36.0 LRejected-Finance | ₹36.0 L | L1 | Rejected-Finance Dis qualified as per DTCN |
Tender Value
₹42.4 L
EMD Value
₹42,400
Closing Date
15 Jan 2026, 5:00 pmClosed
SE R and B Division No-II
Office of SE R and B Division No-II
Electrical Work
2025_EICCL_123943_2
RC(RANDB) RGD NO. II/ 14 /2025-26
Open Tender
Electrical Works
60 days
Rayagada
Please refer tender documents
2 documents required · 2 mandatory
₹6,000
₹42,400
Yes
14 May 2026
2 Jan 2026
16 Jan 2026
2 Jan 2026
15 Jan 2026
2 Jan 2026
WPB 160x152mm (30.44kg/mtr),11mtr with base plate 300x300x12mm
33kV F clamp 2.9kg each(Pole top bracket)
11KV V Cross Arm(22kg each)GI
GI Back Clamp for "V"Cross Arm
33KV DISC(B&S) 90KN Insulator Polymer
33KV H/W Fitting (B&S) type
33KV Pin Insulator 320CD Polymer
100x50x6mm GI channel for straight cross arm 1.8mtr each & 0.2mtr long -including top piece(cut point pole-4nos)
Fish plate (0.661kg/item)=0.661xRs.106.5=Rs.70.4
H.T.Stay set(Complete)
7/8 SWG G.I.Stay wire
33KV Stay Insulator
HT Stay clamp (1.9Kg/Pair) for stud @2/pole
Earthing device Coil type (GI)
8SWG GI wire for earthing
100mm2 AAAC
PG clamp for 100mm2 AAAC (cut point)
G.I.Bolts,Nuts&Washers
Anticlimbing Device (GI barbed wire 3kg per support)
Back clamp for Barbed wire anticlimbing device 25x3mm flat
Danger board
Back clamp for Danger board 25x3mm flat, 0.59kg/mtr
75x40x6mm channel st cross arm 1.5mtr @ 6.8kg/mtr (with galvanisation) for road cross Guarding
No.6 GI wire for road cross guarding 1no.
40mm dia nominal bore pipe (medium gauge) earthing device with 3mtr long
No. 25x6mm GI flat for earthing
No.6 GI wire for earthing.
Eye Hook
Sundries (painting,danger board, clamp, connectors, anticlimbing device, blinding tape etc.)
WPB 160x152mm (30.44kg/mtr),11mtr with base plate 300x300x12mm
Top Pressure chennel 100x50x6mm ,2.8mtr long 2 Nos. (9.2kg/mtr) with galvanisation)
Bracing channel 75x40x6mm GI 2.8mtr long 2nos. (6.8Kg/mtr)
Bracing Angle 50x50x6mm GI 4mtr long 2nos. (6.8Kg/mtr)
33KV DISC(B&S) 90KN Insulator Polymer
33KV H/W Fitting (B&S) type
33KV Pin Insulator type polymer
PG clamp for 100mm2 AAAC (cut point)
Fish plate 50x8mm (0.661kg/item)=0.661xRs.106.5=Rs.70.4
AB switch mounting channel 75x40x6mm ,4.3mtr long 8 Nos. (7.14kg/mtr) with galvanisation)
AB Switch side support GI channel (100x50x6)mm 9.56kg/mtr ,each channl length 0.35Mtr 2nos. Channel required/AB switch
GI channel for support for down pipe 75x40x4.8mm 7.14kg/mtr , each channel length 0.8mtr 1no channel required/AB switch
33KV Lightening Arrestor 30KV ,10KA station class-2
33Kv AB Switch 3Pole ,400A
Earthing device Coil type (GI)
No-8 GI wire (Dia-4.6mm) 0.131Kg/Mtr -2Mtr for connecting pole with coil earthing
Danger board
Back clamp for Danger board 25x3mm flat, 0.59kg/mtr
Anticlimbing Device (GI barbed wire 3kg per support)
Back clamp for Barbed wire anticlimbing device 25x3mm flat
No. 50x6mm GI flat for earthing
GI Nuts ,bolts, and washers
75x40x6mm GI channel st cross arm 1.5mtr @ 6.8kg/mtr (with galvanisation) for road cross Guarding
No.6 GI wire for33KV road cross guarding 1no.
40mm dia nominal bore pipe (medium gauge) earthing device with 3mtr long
No-6 GI wire (Dia-4.6mm) 0.131Kg/Mtr -2Mtr for connecting pole with coil earthing
Eye Hook for guarding
Sundries (painting,danger board, clamp, connectors, anticlimbing device, blinding tape etc.)
Stay Concrete material in ratio 1:2:4 as per TPSODL specification and drawing =0.2Cum @6648.85
Concreting of 11mtr poles in ratio 1:1.5:3=0.45Cum @6648.86
Couping of poles in ratio 1:1.5:3=0.1125Cum @6648.85
Materials for masonary works for earth pit,charcoal, salt etc including construction of earthing chamber (size 2"x2") and RCC slab cover
Dismantelling of 11/13mtr Joist/WPB poles after digging the pit and taking out pole , transportation and stacking the pole aat safr=er posituion within 10km / site store and refilling the pit with loose earth and ramming
Dismantalling of ACSR/AAAC from overheas lines ,recoiling, loading, transportation, uloasding and stacking at proper place
Electrical Inspection fee
WPB 160x152mm (30.44kg/mtr),11mtr
9mtr long 300KG PSC pole
11kV F clamp 2.9kg each(Pole top bracket)
11KV V Cross Arm(10.2kg each)
GI Back Clamp for "V"Cross Arm
11KV DISC(B&S) 70KN Insulator Polymer
11KV H/W Fitting (B&S) type
11KV Pin Insulator Polymer
100x50x6mm GI channel for straight cross arm 1.2mtr each & 0.2mtr long -including top piece
Fish plate (0.661kg/item)=0.661xRs.106.5=Rs.70.4
H.T.Stay set(Complete)
7/10 SWG G.I.Stay wire
11KV Stay Insulator
HT Stay clamp (1.9Kg/Pair) for stud @2/pole
Earthing device Coil type (GI)
No-8 GI wire (Dia-4.6mm) 0.131Kg/Mtr -2Mtr for connecting pole with coil earthing
RCC base plate (500mmx500mmx10mm) for PSC pole
80mm2 AAAC
PG clamp for 80mm2 AAAC (cut point)
G.I.Bolts,Nuts&Washers
Anticlimbing Device (GI barbed wire 3kg per support)
Back clamp for Barbed wire anticlimbing device 25x3mm flat
Danger board
Back clamp for Danger board 25x3mm flat, 0.59kg/mtr
75x40x6mm GI channel st cross arm 1.5mtr @ 6.8kg/mtr (with galvanisation) for road cross Guarding
No.6/8 GI wire for road cross guarding 1no.
40mm dia nominal bore pipe (medium gauge) earthing device with 3mtr long
No-6 GI wire (Dia-4.6mm) 0.131Kg/Mtr -2Mtr for connecting pole with coil earthing
Eye Hook for guarding
No. 25x6mm GI flat for earthing
Sundries (painting,danger board, clamp, connectors, anticlimbing device, blinding tape etc.)
9mtr long 300KG PSC pole
Pressure chennel 100x50x6mm ,2.8mtr long 2 Nos. (9.2kg/mtr) with galvanisation)
Transformer mounting channel 100x50x6mm ,2.8mtr long 2 Nos. (9.2kg/mtr) with galvanisation)
AB switch mounting channel 75x40x6mm ,2.8mtr long 4 Nos. (6.8kg/mtr) with galvanisation)
HG fuse mounting channel 75x40x6mm ,2.8mtr long 4 Nos. (6.8kg/mtr) with galvanisation)
Cantilever channel for supporting HG fuse 75x40x6mm MS Angle 1mtr long 2nos. (6.8Kg/mtr)with Galvanisation
Cantilever channel for supporting AB switch 50x50x6mm MS Angle 1mtr long 2nos. (6.8Kg/mtr)with Galvanisation
Angle mounting for LT Distribution Box 50x50x6mm MS Angle 3mtr long 2nos. (4.5Kg/mtr)with Galvanisation
AB Switch side support GI channel (100x50x6)mm 9.2kg/mtr ,each channl length 0.35Mtr 2nos. Channel required
GI channel for support for down pipe 75x40x6mm 9.2kg/mtr , each channel length 0.8mtr 1no channel required
Transformer belting 50x50x6mm MS Angle 2.8mtr long 2nos. (4.5Kg/mtr) with side angle total (7mtr)with Galvanisation
11Kv AB Switch 3Pole ,200A
11Kv HG fuse 3Pole ,200A
11KV Lightening Arrestor 9KV ,10KA
11KV Disc Insulator (T&C) 45KN ,polymer
11KV H/W fittings (T&C) 45KN ,polymer
HT stay set complete REC standard
7/10 GI stay wire (Grade-2)
HT stay Insulator Type-C
Stay clamp(1.9Kg/pair)
GI pipe earthing 40mm dia medium gauge 3mtr long earth device
GI Flat(25x6)mm
LT distribution box with MCCB , Al. busbar of single bay with Kitkat fuse for 25KVA DSS
G.I.Bolts,Nuts&Washers
55sqmm AAA conductor for jumpering
1x70sqmm ,1core LT pVC cable Unarmoured DTR to LTDB
RCC base plate (500mmx500mmx10mm) for PSC pole
Earthing for supports (Coil type)
No-8 GI wire (Dia-4.mm) 0.131Kg/Mtr -2Mtr for connecting pole with coil earthing
Danger board
Back clamp for Danger board 25x3mm flat, 0.59kg/mtr
Anticlimbing Device (GI barbed wire 3kg per support)
Back clamp for Barbed wire anticlimbing device 25x3mm flat
Sundries (painting,danger board, clamp, connectors, anticlimbing device, blinding tape etc.)
WPB 160x152mm (30.44kg/mtr),11mtr with base plate 300x300x12mm
RCC base plate (500mmx500mmx10mm) for PSC pole
Pressure chennel 100x50x6mm ,2.8mtr long 2 Nos. (9.2kg/mtr) with galvanisation)
Bracing channel 75x40x6mm GI 2.8mtr long 2nos. (6.8Kg/mtr)
Bracing Angle 50x50x6mm GI 4mtr long 2nos. (6.8Kg/mtr)
11KV DISC(B&S) 70KN Insulator Polymer
11KV H/W Fitting (B&S) type
11KV Pin Insulator type polymer
PG clamp for 80mm2 AAAC (cut point)
Fish plate (0.661kg/item)=0.661xRs.106.5=Rs.70.4
H.T.Stay set(Complete)
11KV Stay Insulator
HT Stay clamp (1.9Kg/Pair) for stud @2/pole
7/10 SWG G.I.Stay wire
Earthing device Coil type (GI)
No-8 GI wire (Dia-4.6mm) 0.131Kg/Mtr -2Mtr for connecting pole with coil earthing
Danger board
Back clamp for Danger board 25x3mm flat, 0.59kg/mtr
Anticlimbing Device (GI barbed wire 3kg per support)
Back clamp for Barbed wire anticlimbing device 25x3mm flat
GI Nuts ,bolts, and washers
75x40x6mm GI channel st cross arm 1.5mtr @ 6.8kg/mtr (with galvanisation) for road cross Guarding
No.6/8 GI wire for road cross guarding 1no.
40mm dia nominal bore pipe (medium gauge) earthing device with 3mtr long
No. 25x6mm GI flat for earthing
No-6 GI wire (Dia-4.6mm) 0.131Kg/Mtr -2Mtr for connecting pole with coil earthing
Eye Hook for guarding
Sundries (painting,danger board, clamp, connectors, anticlimbing device, blinding tape etc.)
8mtr long 200KG PSC pole
9mtr long 300KG PSC pole
Pole clamp with I hook
Dead End clamp
I hooh for Dead End clamp
GI Nuts ,bolts, and washers
LT Stay set Complete
LT Stay Insulator
LT Stay Clamp (1.4Kg/pair)
7/12SWG G.I.stay wire
RCC base plate (500mmx500mmx10mm) for PSC pole
Earthing device Coil typr(GI)
No-8 GI wire (Dia-4.6mm) 0.131Kg/Mtr -2Mtr for connecting pole with coil earthing
Anticlimbing Device (GI barbed wire 3kg per support)
Back clamp for Barbed wire anticlimbing device 25x3mm flat
Danger board
Back clamp for Danger board 25x3mm flat, 0.59kg/mtr
Sundries (painting,danger board, clamp, connectors, anticlimbing device, blinding tape etc.)
Stay Concrete material in ratio 1:2:4 as per TPSODL specification and drawing =0.2Cum @6648.85
Concreting of 8mtr poles in ratio 1:1.5:3=0.375Cum @6648.85
Concreting of 9mtr poles in ratio 1:1.5:3=0.375Cum @6648.86
Concreting of 11mtr poles in ratio 1:1.5:3=0.45Cum @6648.86
Couping of poles in ratio 1:1.5:3=0.1125Cum @6648.85
Materials for masonary works for earth pit,charcoal, salt etc including construction of earthing chamber (size 2"x2") and RCC slab cover
Dismantelling of 8/9mtr PSc poles after digging the pit and taking out pole , transportation and stacking the pole aat safr=er posituion within 10km / site store and refilling the pit with loose earth and ramming
Dismantalling of ACSR/AAAC from overheas lines ,recoiling, loading, transportation, uloasding and stacking at proper place
Dismantalling of , steel structure (Anglr/channel/flats/nuts/bolts)from overheas lines ,recoiling, loading, transportation, uloasding and stacking at proper place
Dismantelling of 25KVA Transformer loading, transportation, uloasding and stacking at proper place
Electrical Inspection fee
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_573611.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.36 MB
DTCN_S_Hatamuniguda.pdf
Tender Documents • 1.64 MB
BOQ_573611.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid