Lt Col Aditya Vanka
GE Navy Lakshadweep Coast Guard Road Kavaratti Island UT Of Lakshadweep 682 555
PERIODICAL SERVICES TO CERTAIN BUILDINGS AT MINICOY UNDER GE NAVY LAKSHADWEEP
2021_MES_474864_1
8300/E8
Open Tender
Civil Works
Item Rate
270 days
Minicoy
As per Tender documents
8 documents required · 8 mandatory
₹500
GE Navy Lakshadweep
₹14,000
Yes
7 Jun 2022
13 Sept 2021
14 Oct 2021
13 Sept 2021
12 Oct 2021
27 Sept 2021
15 Sept 2021 - 22 Sept 2021
60 days
Amount
Material and Labour for complete removal of exisiting treatment on wall surfaces and applying damp proof coating in three layer treatement by applying first coat of Dr. fixit Dampguard classic followed by a coat of Dr. fixit Dampguard classic putty prepared by mixing 1 part of Damguard classic with 1 part of white cement (OPC) mixed so as to obtain consistency of a putty and finally applying second coat of Dr. fixit Dampguard classic, complete all as per manufacturers instructions, the treated surfaces shall be finished smooth and followed by two coats of distemper oil emulsion over a coat of alkali resistant primer, complete all as specified and directed by Engineer-in-Charge. Note: Rate quoted is deemed to include for providing 104 Dampguard classic of Make Dr. Fixit completely in three layers including layer of putty, as per manufactures instruction upto the satisfaction of Engineer-in-Charge inorder to obtain desired finish and for arresting dampness completely.
Taking down cement plaster on brick walls or stone walls any descrition etc... including raking out joints, hacking for key, scrubbing down with water etc all as specified and directed by Engineer-in-Charge.
Material and Labour for Rendering 10 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:6), finished even and smooth without using extra cement complete all as specified and as directed.
Rendering 5 mm thick cement plaster on faces of brick work or concrete surfaces in cement mortar (1:3), as in ceiling, finished even and fair without using extra cement all as specified and directed by Engineer-in-Charge.
Material and Labour Rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement including mixing of water proofing compound @ 3% by weight of cement, complete all as specified and directed by Engineer-in-Charge. Note: WPC will be measured and paid seperately as supply only item.
Supply only integral water proofing compound
Material and labour for preparation of new plastered surface of wall and applying 1.5 mm thick wall care putty and making the surface smooth followed by Two coats of Distemper oil emulsion, acrylic distemper (ready mixed), of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over a coat of alkali resistant primer complete all as specified & directed by Engineer-in-Charge.
Material and Labour three coats of white wash on surface of ceiling including preparation of new plastered surface complete all as specified and directed by Engineer-in-Charge.
Material and Labour for preparation old decorated painted surfaces of walls and applying one coat of exterior weather proof emulsion paint complete all as specified and directed by Engineer-in-Charge.
Material and Labour for preparation old decorated painted surfaces of walls and applying one coat of alkali resistant priming paint complete all as specified and directed by Engineer-in-Charge.
Material and labour for Complete removal of existing treatment and applying two or more coats of 100% Premium acrylic weather proof emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed by Engineer-in-Charge.
Material and Labour for preparation of newly plastered and concrete surfaces and applying two coats of exterior emulsion weather proof paint (Appex Ultima or equivalent) of any colour, over a coat of exterior primer, over a coat of cement based exterior putty not less than 1mm thick on wall/column projection, chajjas sides and bottom, roof projection, wall etc... completely all as specified and directed by Engineer-in-Charge.
Material and labour for Complete removal of existing treatment and applying one coat of Dr. Fixit Raincoat weatherproof coating without any dilution to maintain a spread of 4.0 Sqmt per liter per coat to achieve 120-130 micron thickness and after drying applying two or more coats of 100% Premium acrylic weather proof emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed by Engineer-in-Charge. Note: Rate quoted shall be deemed to include for necessary scaffoldings for buildings upto G+1 Storey, Dr. Fixit Raincoat weatherproof coating as per manufacturers instructions, exterior primer and Weather proof emulsion paint
Material and Labour for preparation old decorated painted surfaces of ceiling and applying one coat of white wash complete all as specified and directed by Engineer-in-Charge.
Material and Labour for preparation old decorated painted surfaces of walls and applying one coat distemper oil emulsion complete all as specified and directed by Engineer-in-Charge.
Material and Labour for preparation old decorated painted surfaces of walls and applying one coat cement base paint, for compound walls, manholes, septic tanks, kerbs, valve pits etc… complete all as specified and directed by Engineer-in-Charge.
Material and Labour for one coat of synthetic enamel paint on wooden surfaces including preparation of old painted surfaces, over 10cm width or girth, complete all as specified and directed by the Engineer-in-Charge
Material and Labour for one coat of Epoxy enamel paint on steel surfaces including preparation of old painted surfaces, over 10cm width or girth, complete all as specified and directed by the Engineer-in-Charge
BHATNAGAR ASSOCIATES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .