| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-Finance E 84 OF HQ CWE NW MUMBAI AGE 87 1 3 GEETA NAGAR NAVY NAGAR COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-Finance Lowest one | |
| 2 | L2₹28.0 L+₹1.5 L (5.67%)Rejected-Finance ROOM NO 680 GANESH MURTY NAGAR PART NO 03 CAPT PRAKASH PETHE MARG COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Other than lowest one | |
| 3 | L3₹28.8 L+₹2.3 L (8.79%)Rejected-Finance | L3 | Rejected-Finance Other than lowest one | |
| 4 | L4₹33.2 L+₹6.7 L (25.1%)Rejected-Finance | L4 | Rejected-Finance Other than lowest one | |
| 5 | L5₹33.6 L+₹7.1 L (27.0%)Rejected-Finance | L5 | Rejected-Finance Other than lowest one |
Tender Value
Refer Docs
EMD Value
₹99,980
Closing Date
25 Jun 2024, 6:00 pmClosed
GE NW NOFRA
Dr Homi Bhabha Road New Navy Nagar Colaba Mumbai
REPAIR REPLACEMENT OF OLD DETERIORATED STREET LIGHT POLES AND LED STREET LIGHTS STREET LIGHT DRIVER DECORATIVE LIGHT LOOPING BOX AND GARDEN LIGHTS STREET LIGHT CABLES AT INS SHIKRA BOAT POOL PASTA LANE NT POOL AND OUTLAYING AREAS UNDER GE (NW) NOFRA
2024_MES_658202_1
8272
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Mumbai
please refer tender documents
8 documents required · 8 mandatory
₹500
GE NW NOFRA
₹99,980
Yes
1 Jul 2024
6 Jun 2024
27 Jun 2024
6 Jun 2024
25 Jun 2024
20 Jun 2024
6 Jun 2024 - 13 Jun 2024
Amount
Note : (a) Uniform for all deployed staff in duty supervisor as approved by GE. (b) Functional tools & plants shall be carried by tradesman all time for attending any site. (c) Necessary ladder / cloth or any other material reqd. (d) Debris / site clearance immediately before leaving site. (e) Safety eqpt to be carried all time. (f) In case of non-adherence of any of above fine/ penalty to be carried as under:- (i) 1st Time - Rs 200/- (ii) 2nd Time - Rs 500/- (iii) 3rd Time - Warning to contractor. (g) In case of 3 warning to contractor, it will be reflected in WLR for slow progress. (h) Complaint registered upto 11:00AM & emergency complaint to be attended same day. (j) Complaint Team consist of 02 Electrician alongwith reqd helpers.
Excavation in trenches not exceeding 1.5 Mtrs. wide and not exceeding 1.5 Mtrs. in depth for foundation, laying of cablesetc and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc. 25cm depth in soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material (Soil) n.exc 50 m and depositing where directed at a level n. exc 1.5 Mtrs. above the starting point complete all as specified and directed by Engineer-in-Charge.
Cutting and removing grass, vegetation bushes etc and brooming in side/outside of water supply electric supply installation and removing all rubbish to a distance not exceeding 50 m as directed and cleaning/ brooming in water /electric supply station complete all as specified and directed by Engineer-in-Charge.
Trimming tree branches on the route of LT line nearer to LT/HT line , pump house , pipe , roof, street light fitting & poles complete all as specified and directed by Engineer-in-Charge.
Taking down, Checking and repairs to street light fitting from Truss ,Highbay light, flood light , Perimeter light , Post Top Lanterns, Obstruction light, Avaition light fittings inside / out side of NT POOL, SASSON COMPLEX , BOAT POOL, TALWAR CAMP, REIVERA & HARBOUR HEIGHTS, DUXBURY, ADITI AHILYA, VISHAKHA , VANDNA AND FOMA HOUSE , fitting any height street light pole (7/9/11) mtrs, hanger, truss, wall repair and checking and cleaning internal complete wiring, bulb, ignitor, holder, rectifying the defects and removing of burnt cable if any including repair/replacing the unserviceable items as mentioned in below items (wherever necessary) and testing the same on ground at site for its serviceability and refixing the same at original place/location complete all as specified and directed by Engineer-in-Charge. Note :- (a) If the contractor have not given job card to his tradesman in any working day and have not attended any complaint , the necessory recovery of Rs. 500/- per day shall be imposed by Engineer-in-charge . (b) Routine check shall be done for all types of non opps street / security light fitting in each and every location in routine wise manner every day by tradesman. (c) Driver and cable shall be measured paid and separately.
S&F cable junction boxes IP 66/67 weather proof for out door installation with knock outs cable entry junction box size should be 205x255x112mm with terminals including complete all accessories, all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable junction box. S&F of new cable junction boxes IP 66/67 weather proof for outdoor installation (with knock outs cable entry junction box size should be 300x100x450 mm aluminium bus bar 4 strip mounted on protection insulator with two Nos and front openable hinged and locking arrangements including complete all accessories , all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable garden light. Supply and fixing of LED garden light 9 W cylindrical shaped integral decorative LED bollard with Opal acrylic diffuser and IP 65 With all acessories including PCC foundation tapper plug bolts,nuts,screwed and GI pipe of suitable dia etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix new generation ruby LED post top series IP 65 LED post-top 35 Watt, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source Clear Cover offers bright illumination for different applications including suitable dia of GI pipe and taking down old post top complete all as specified and directed be Engr in Charge.
Supply and fix Cone NXG series 8 watt LED Bollard acts as an imposing street furniture with touch of aesthetic innovative design with uniformly lit diffuser at the upper portion acts a beacon of path guidance in a landscape environment with robust IP 65 rating including PCC foundation, nut bolts etc including taking down old unsv bollard complete all as specified and directed by Engr in Charge.
Supply and fix Street light timer, Astronomical time operation, sunrise sunset based operations, Current Rating (In Amps): 20 Amp, Display : Digital, Operating Temperature: -10 to 55, Power/Voltage: 110 - 240VAC including taking down old street light panel complete all as specified and directed.
Material and Labour for Attending Faults/Trippings and rectifying /repairing the faults in street light panel/ Junction box/ cable fault/ connection/ busbar including PVC insulating Tapes/Nut bolts and all as specified and directed by Engineer-In-Charge. [Note : Damaged/Burnt MCCB/MCB/cable/changeover switch will be measured and paid separately]
Supply only MCCB,4Pole,250 Amps,25kA, 415Volts,50Hz AC including taking down old MCCB complete all as specified and directed by Engr-in-charge.
Supply only MCCB,4Pole,160 Amps,25kA, 415Volts,50Hz AC including taking down old MCCB complete all as specified and directed by Engr-in-charge.
Supply only MCCB,4Pole,100 Amps,25kA, 415Volts,50Hz AC including taking down old MCCB complete all as specified and directed by Engr-in-charge.
Supply only MCCB,4Pole,63 Amps,25kA, 415Volts,50Hz AC including taking down old MCCB complete all as specified and directed by Engr-in-charge.
Supply only Change Over Switch ,4Pole, 63 Amps, Open Execution,ON LOAD type 415Volts,50Hz AC including taking down old changeover switch complete all as specified and directed by Engr-in-charge.
Supply only Change Over Switch ,4Pole, 100 Amps, Open Execution,ON LOAD type 415Volts,50Hz AC including taking down old changeover switch complete all as specified and directed by Engr-in-charge.
Supply only Change Over Switch ,4Pole, 250 Amps, Open Execution,ON LOAD type 415Volts,50Hz AC including taking down old changeover switch complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair Steel tubular swaged street light poles complete with pole arms 1.2 m & cast iron base plate ,finial taper plug,bolts,nuts and screws as specified type 410 SP-31 , 8.5 mtr long and painting with two coat of aluminium paint over one coat of primer on exposed surface of pole including taking down old rusted pole complete all as specified and directed by Engineer-in-Charge. (NOTE- Excavation & PCC will be measured and paid separately)
Supply & fix hot dip galvanized anti corroded weather proof octagonal electric poles 6 mtrs long top mounting on foundation complete with base plate and final including PCC foundation as per manufacturer design with 1500 mm long Arms bracket,tapper plug,bolts nuts and screws incl aluminium painting etc as specified complete all as specified and directed including taking out existing damaged pole with street light bracket complete.
S&F in repair of new 45 watt LED new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting Source and LENs embedded toughned glass cover with IP66 Protection and impact resistance of IK07 including taking down old light complete all as specified and directed by Engineer-in-Charge.
S&F LED Bldg security light 70 Watt indus series powder coated pressure die cast aluminium high power LED bldg security light with heat resistant toughned glass with lens with IP66 Protection including taking down old light complete all as specified and directed by Engineer-in-Charge.
S&F 120 WATT LED street light made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 including taking down old light complete all as specified and directed by Engineer-in-Charge.
S&F 150 WATT LED street light made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 including taking down old light complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of Industrial highbay integral LED fittings of capacity 120 watt complete and all accessories at top of any height of workshop hanger including proper hanging fixing with angle/rond bar flat iron with clamping as good appearance including taking down old light complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of Industrial highbay integral LED fittings of capacity 150 watt complete and all accessories at top of any height of workshop hanger including proper hanging fixing with angle/rond bar flat iron with clamping as good appearance complete all as specified and directed by Engineer-in-Charge.
Supply only LED driver for street light / highbay light fitting / flood light from 45 watt to 250 Watt 230 volt of any type and size etc to match with existing complete all as specified and directed by Engineer-in-Charge.
S&F driver for 2 x 2 feet, 36 Watt 230 volt recess mounted LED light of suitable size including taking down old driver complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of MCB, SPN 40/63 Amps 10 KA capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed by Engineer-in-Charge.
Supply only of MCB SP 6-32 Amps, 240 Volts complete all as specified and directed by Engineer-in-Charge.
Supply only MCB , TPN 40-100 Amps capacity, C Curve type suitable for 240 volts AC supply short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed by Engineer-in-Charge.
S&F 120 Watt LED flood light with high performance luminare with pressure die- cast housing toughened glass and secondary lens optics with IP 66 ingress protection efficency 120 lm/W including taking down old light complete all as specified and directed.
S&F 150 Watt LED flood light with high performance luminare with pressure die- cast housing toughened glass and secondary lens optics with IP 66 ingress protection efficency 120 lm/W including taking down old light complete all as specified and directed.
S&F 250 Watt LED flood light with high performance luminare with pressure die- cast housing toughened glass and secondary lens optics with IP 66 ingress protection efficency 120 lm/W including taking down old light complete all as specified and directed.
Supply and fix test Link for connecting the earth pit and down conductor including taking down old complete all as specified and directed by Engineer-in-Charge.
Supply and fix 1x50 sqmm copper conductor with 0.5 mm thick PVC sheathed cable including taking down old cable complete all as specified and directed.
Supply and fix iron clamp (flate 25 x 4 MM) with nuts, bolts, washers and removing old clamps complete all as specified and directed by Engineer-in-Charge.
Supply and fix bracket for street/security light fitting made of GI pipe 25 / 40 mm light grade 1.2 m long bend to shape including two Nos of clamps nuts and bolt as required including taking down old bracket complete all as specified and directed by Engineer-in-Charge.
supply and fix bracket for street/security light fitting made of GI pipe 50 mm light grade 1.2 m long bend to shape including two Nos of clamps nuts and bolt as required including taking down old bracket complete all as specified and directed by Engineer-in-Charge.
M&L for straight through jointing heat shrinkable kit for cable of 240/300 sqmm 3.5 core suitable for aluminium conductor including earth work complete for LT cables complete all as specified and directed by Engineer-in-Charge.
M&L for straight through jointing heat shrinkable kit for cable of 95 to 185 sqmm 3.5 core suitable for aluminium conductor including earth work complete for LT cables complete all as specified and directed by Engineer-in-Charge.
Supply and lay Insulated screened PVC bedded, copper electric cables 1100 Volts grade with stranded Copper conductor of size 1.5 sqmm 2 core. laid in duct / along pole/wall etc including making connection and taking down old cable complete all as specified and directed.
Supply and lay Insulated screened PVC bedded, copper electric cables 1100 Volts grade with stranded Copper conductor of size 2.5 sqmm 2 core. laid in duct / along pole/wall etc including making connection complete all as specified and directed by Engineer-in-Charge.
Supply and laying copper cable PVC bedded, electric power cables (heavy duty) 1100 Volts grade with stranded sheathed copper conductor of size 4 Sqmm 2 core. laid in junction box / along pole /street light fitting /wall etc including making connection and taking down old unsv rusted cable complete all as directed.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 10 sq mm 3 core laid in duct / along pole/wall etc including making connection and taking down old cable complete all as specified and directed by Engineer-in-Charge.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 3.5/4core laid in duct / along pole/wall including making connection complete all as specified and directed by Engineer-in- Charge.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5/4 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed by Engineer-in-Charge. [Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.]
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as directed.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed by Engineer-in-Charge.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as directed.
M&L For Cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregates), in foundation and mass concrete etc complete all as specified and as directed.
M&L For Cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregates) as in coping, blocks, bed plates, kerbs etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary formwork as required complete all as specified and directed.
M&L For Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Engineer-in-Charge.
S&F HDPE of pressure rating 6kg/cm sq pipe of 65 mm outer dia including necessary bends, elbows, Tees etc on cable protection complete all as specified and directed by Engineer-in-Charge.
S&F HDPE of Pressure rating 6kg/cm sq pipe of 40 mm dia including necessary bends,elbows,Tees etc on cable protection complete all as directed.
M&L for scraping the old paint from steel tublar poles by wire brush not more than up to 9/11 mtr length above ground level including street light arms applying one coat of steel primer and two coat of aluminium paint and marking pole no. complete all as specified and directed by Engineer-in-Charge.
Supply and fix recesss mounted 2 x 2 feet panel 36 Watts LED luminary back lit recess mounting , CRCA housing white powder coated, with decorative polymer diffuser complete with accessories locking arrangement, clips , per wire for connection and fixing in falls ceiling including taking down old light complete all as directed by Engr -in-Charge.
Material and labour for refixng of Old uprooted lightening arrestor strips including saddling of strips with suitable saddles and nails all as directed at site by Engineer - in - Charge.
M&L in replacement Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strips 25 x 4 mm including taking down old strip complete all as specified and directed be Engr in Charge.
Testing of earthing for earth resistance provided for various electrolde/ digital meter in panels /bldgs /main DB of building inside / motor/ DG set / transformer/ OVB/VCB/ etc all as per clause 19.146.3 of SSR part-I and recording the test results complete including providing earth megger and test leads complete all as specified and as directed. (Note :- The results are to be recorded in register as directed by Engineer-in-charge)
Material and labour for refixng of Old uprooted Air Termination Rods including saddling with suitable saddles and nails all as directed at site by Engineer - in - Charge.
M&L in Replacement Air termination, single pointed aluminium rod 12mm dia and 300mm long
M & L for in Repair/replacement coping of existing street light poles complete with PCC 1:2:4 D2 type 20 mm graded stone, painting after PCC work complete all as specified and directed at site by Engr - in- Charge.
B P ENTERPRISES
ORIENT ELECTRIC CO
shubham construction
SRISHTI CONSTRUCTIONS
SHREE JAGDISH FURNITURE CO.
M/s ASPIRE ENGINEERING ENTERPRISES
NOEL ENGINEERS
Shree Ayyappa Engineering
M/S V N ENTERPRISES
DHARMESH ENTERPRISES
SHRI SAI ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .