Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 CrAccepted-AOC ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹6.4 Cr Quoted ₹6.5 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹6.6 Cr+₹6.1 L (0.93%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹6.6 Cr+₹6.1 L (0.93%) | L2 | Rejected-Finance L2 |
| 3 | L3₹6.6 Cr+₹11.3 L (1.72%)Rejected-Finance ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | ₹6.6 Cr+₹11.3 L (1.72%) | L3 | Rejected-Finance L3 |
| 4 | L4₹6.8 Cr+₹25.3 L (3.86%)Rejected-Finance | ₹6.8 Cr+₹25.3 L (3.86%) | L4 | Rejected-Finance L4 |
| 5 | L5₹6.9 Cr+₹36.1 L (5.52%)Rejected-Finance NATIONAL TOWER 5TH FLOOR SCO 89 DSC RANJIT AVENUE AMRITSAR 143001 PUNJAB | AMRITSAR | AMRITSAR | PUNJAB | 143001 | ₹6.9 Cr+₹36.1 L (5.52%) | L5 | Rejected-Finance L5 |
Tender Value
₹7.2 Cr
EMD Value
₹6.8 L
Closing Date
27 May 2024, 6:00 pmClosed
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
ADDN/ ALTN AND UPGRADATION OF CERTAIN MD ACCN FOR OFFRS/ JCOs/ ORs AT NAMS
2024_MES_643741_1
81065/E8
Open Tender
Civil Works
Item Rate
365 days
Jalandhar Cantt
All documents as per NIT
8 documents required · 8 mandatory
₹3,000
Garrison Engineer NAMS
₹6.8 L
Yes
19 Jul 2024
28 Mar 2024
4 Jun 2024
28 Mar 2024
27 May 2024
13 May 2024
Amount
Note: Please refer Schedule 'A' Notes given on serial page No. 20, 21, 22(R) & 23 of tender documents.
LIST OF WORKS FOR BUILDING WORKS
Demolition of cement concrete (unreinforced) in ground floors and paving not exc. 15 cm thickness including part chipping (below or above ground level) complete all as specified and directed.
Dismantling of terrazzo in dado, walls tiles, including bedding but backing and rubbish off premises complete all as specified and directed
Demolition of reinforced cement concrete above the ground floors not exc. 15 cm thickness (Reinforcement cut as required to facilitate demolition) such as cooking platform, chajjas etc complete all as specified and directed.
Material and labour for treatment of soil under existing floors using emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed
Material and labour for anti termite treatment along the external wall below concrete or masonry around using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed
Material and labour for 10mm thick light shade Vitrified tiles double charged in floors, exc 0.18 Sqm but not exc. 0.36 Sqm set & jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed.
Material and labour for vitrified double charged tiles 9 to 10mm thick square/rectangular) polished area of each tiles not exceeding 0.36 Sqm as in vertical surfaces such as dado/ skirting etc. set and jointed in neat cement slurry and in coloured cement to match including plaster (backing coat) 10mm thick in cement mortar 1:3 complete all as specified and directed
Material and labour for 7 to 8mm thick non-skid ceramic tiles in floors, exc. 0.18 Sqm but not exc. 0.38 Sqm set & jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed
Material and labour for non-skid ceramic coloured tiles 7 to 8mm thick (Square or rectangular) area of each tile exc. 0.18 Sqm but not exceeding 0.38 Sqm, as in skirting, dado in vertical surfaces etc. and including 10mm thick backing cement plaster 1:3 etc complete all as specified and directed
Material and labour for Non-Skid ceramic colour tiles 7 to 8mm thick (Square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 15mm thick rendering in CM 1:6 complete all as specified and directed
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed.
Material and labour for Baroda green marble work 18 to 20mm thick (table rubbed and polished) laid over and including 20mm thick screed bed of CM 1:6 as in flooring and jointed with grey cement slurry mixed with pigment to match the shade, rubbing & polishing complete all as specified and directed
Material and labour for Baroda green marble work 18 to 20mm thick (table rubbed and polished) laid over and including 10mm thick cement plaster of CM 1:3 as in riser /skirting and jointed with grey cement slurry mixed with pigment to match the shade, rubbing and polishing and complete all as specified and directed. Note for Srl Item No. 13.00 & 14.00 : Green marble shall be of single piece & from same lot & uniform in colour
Material and labour for 25mm thick cement concrete (1:2:4), type B-0, using 12.5mm graded aggregate as in floors including finishing the surface rough & even for receiving kota stone/ tiles and similar works like under sunken floor etc complete all as specified and directed
Material and labour for glazed ceramic coloured tiles of size 450 mm x 300 mm x 7mm on vertical surface such as skirting, dados, risers to steps etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, over and including rendering 10mm thick in cement mortar (1:3), etc. complete all as specified and directed
Demolition of brick work built in cement mortar including all quoins, arches, pillars, etc complete all as specified and directed
Material and labour for Brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in CM (1:6) complete all as specified and directed.
Material and labour for Brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 as in half brick thick wall complete all as specified and directed.
Material and labour for PCC 1:4:8 type D-2 (using 40mm graded aggregate) as in foundation, sub base, mass concrete etc. complete all as specified and directed
Material and labour for 50mm thick cement concrete 1:3:6 type C2, using 40 mm graded stone aggregate as in plinth protection, finishing cement concrete surfaces even and smooth without using extra cement, joints of plinth protection shall be filled with bitumen mastic (1:3) complete all as specified and as directed
Material and labour for PCC 1:2:4 type B1 using 20 mm graded stone aggregate for insertion of hold fast including necessary form work etc. complete all as specified and directed
Material and labour for repairing of RCC projection, chajjas, facia, bands, shelves, beams, RCC railing, balcony and similar works by dismantling of loose/ disintegrated portion RCC at any height and in any sitution floor (including provn of support, with chicken wire mesh and dubbing/ filling with PCC (1:2:4), type B-0, using 12.5 mm graded aggregate,15 to 25 mm thick after applying cement slurry @ 3 kg/sqm, finished even and smooth to desired shape and applying two coats of finishes to match with existing surfaces complete all as specified and directed
Taking down cement plaster on wall/ceiling/roof etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed.
Material and labour for 15mm thick cement plaster in CM 1:4 on fair faces of brick or concrete work and finishing the surface even and smooth (without using extra cement) with liquid WPC as per manufacturer's instructions complete all as specified and directed. Note : Liquid WPC will be measured and paid separately under appropriate item.
Material and labour for 12 mm thick rendering on fair faces of brick or concrete surfaces in CM (1:6), finished even and smooth (without using extra cement) complete all as specified and directed.
Material and labour for applying finishing walls with Acrylic smooth exterior paint of required shade : New surface work (Two coats applied @ 1.67 Ltr/10 Sqm each coat) over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified and as directed.
Material and labour for preparation of old surfaces of walls, pillars, cornices etc. including scrapping down smoke, soot, and efflorescent salts and treating oil and greasy spots, brooming down or steel wire brushing removing nails making good holes, cracks etc. on plastered or un-plastered surfaces and finishing walls with Acrylic Smooth exterior paint of required shade : Old surface work (Two coats applied @ 1.67 Ltr/10 Sqm each coat) complete all as specified and directed
Material and labour for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces of ceiling and finishing the surfaces even and smooth complete all as specified and directed.
Supply only liquid water proofing compound, ISI marked complete all as specified and directed.
Material and labour for applying two coats of oil bound distemper over a coat of primer including 1 mm thick wall care putty on wall of newly plastered surfaces of walls, pillars cornices etc. complete all as specified and directed
Material and labour for applying 3mm thick wall care putty to achieve even and smooth surfaces on old plastered surfaces wall/ceiling and obtain using sand paper complete all as specified and directed
Material and labour for preparation of newly plastered surfaces of ceiling including pilasters, cornices etc and applying three coats of white wash complete all as specified and directed
Material and labour for preparation of old surfaces of walls, pillars, cornices etc. including scrapping down smoke, soot, and efflorescent salts and treating oil and greasy spots, brooming down or steel wire brushing removing nails making good holes, cracks etc. on plastered or un-plastered surfaces and applying two coats of oil bound distemper on wall (white or tinted) complete all as specified and directed
Material and labour for preparation of old surfaces of ceiling including scrapping down smoke, soot, and efflorescent salts and treating oil and greasy spots, brooming down or steel wire brushing removing nails making good holes, cracks etc. on plastered or un-plastered surfaces and applying one coat of white wash on ceiling surface complete all as specified and directed
Taking down chowkats or frame with shutters of any description (without taking off shutters from the frames) not exc. 1.5 Sqm each complete all as specified and directed.
All as per Srl item No 36.00 above but exc 1.5 Sqm but not exc. 4 Sqm each complete all as specified and directed
Material and labour for 30mm thick factory made solid PVC (Wood plastic composite) moulded gauged door shutter with wire mesh in any number of division with brown wood grain texture, including stainless steel wire mesh shall be fixed with 15 x 15 Square tubes in is rails with screwing 8 x 28 mm heat metal zinc coated screws can be remove or fix again after changing of wire mesh when needed. The density shall be as per manufactures instructions complete all as specified and directed
Material and labour for Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 Kg/Cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk stainless steel screws, complete all as specified and directed. Note : Stainless steel butt hinges and necessary stainless screws shall be paid separately.
Material and labour for Factory made single extruded WPC (Wood Polymer Composite) solid door frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 Kg/Cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant including making good after complete all as specified and directed.
All as per Srl item No 40.00 above but of frame size 65 x 125 mm including all fittings making good after complete all as specified and directed
Taking down chowkhats or frames of any description not exc 1.5 Sqm each complete all as specified and directed
Supply and fix anodised aluminium powder coated frame any colour minimum coating 50 micron three track windows/ventilators with one or more rebates including joining cleat for fixing etc. complete and making good to disturbed surface with cement concrete 1:2:4 and cement mortar 1:4 complete all as specified and directed. Note :- Sheet glass, wire cloth, etc shall be measured and paid separately
Supply and fixing anodised aluminium powder coated three track window and ventilator shutters, sliding/side hung type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary aluminium joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1 No.), hinges type B-21 100mm long (2 Nos.) suitable handle (1 No.), rollers etc. complete all as specified and directed
Supply and fixing 5.0mm thick, black tinted glass panes with nano coating fixed to aluminium doors/ windows/ vents with necessary rubber gaskets complete all as specified and directed
Supply and fixing stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staple/ wooden beads complete all as specified and directed
Supply and fixing 100mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed
Supply and fixing aluminum alloy anodised sliding door bolts with hasp & staple & fixing clips of sheet cast extruded section & fixing bolts & sliding bolts of extruded section 300mm long complete all as specified and directed
Supply and fixing 300mm mild steel ordinary rat tail rod pattern spring including roller plate complete all as specified and directed
Supply and fixing 200 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed
Supply and fixing 150mm extruded aluminium alloy handles, fabricated type anodised complete all as specified and directed
Supply and fixing floor door stopper 140 mm overall length of cover plate of aluminium alloy body and tongue, anodised. With hard drawn spring, fixed in floor complete all as specified and directed
Supply and fixing 100 mm long hasp & staple aluminium anodised wire type, including bolt to hinge plate and fixed with screw complete all as specified and directed
Supply and fixing 100mm dia extruded brass handle, fabricated type polished fixed to board complete all as specified and directed
Supply and fixing 30 mm wide continuous (piano) hinges, mild steel, bright finish or electro galvanised complete all as specified and directed
Supply and fixing in repair, glass shelf with CP brackets and with decorative railing fixed to wall complete all as specified and directed
Supply and fixing in repair glass corner (set of three) complete all as specified and directed
Supply and fixing MS Peg set of six Nos hooks powder coated complete all as specified and directed
Supply and fixing in repair, 20mm dia, 1mm wall thickness stainless steel fancy type, decorative curtain rod with decorative ball type side brackets (as per Sample) fix with wooden gutties complete all as specified and directed
Taking up or down steel tubing and connections for 15mm bore of pipe complete all as specified and directed
Taking up or down steel tubing and connections for 20mm bore of pipe complete all as specified and directed
Supply & laying of CPVC pipes 20mm outer dia, SDR 11 & Plain CPVC SDR 11 fitting on wall/ ceiling or laying in floors including all necessary fittings conforming to IS complete all as specified and directed
Supply & laying of CPVC pipes 25mm outer dia, SDR 11 & Plain CPVC SDR 11 fitting on wall/ ceiling or laying in floors including all necessary fittings conforming to IS complete all as specified and directed
Supply and fixing in repair, for 15mm bore fancy type central hole basin mixer with 135mm extension body fixed spout without popup waste system with 450mm long braided hoses of 15 degree flow angle complete all as specified and directed
Supply and fixing in repair, chromium plated single lever wall mixer 3-in-1 with connector for hand shower arrangement with connecting legs, wall flanges and wall brackets for hand shower complete all as specified and directed
Supply and fixing in repair, brass chromium plated single lever wall mixer 3-in-1 system with provision of both overhead shower with 115 mm long bend pipe connecting legs and wall flange (without head shower) complete all as specified and directed
Supply and fixing in repair, 15mm bore single lever Sink mixer complete all as specified and directed
Supply and fixing in repair, Vitreous China counter top Wash Hand Basin size 565 x 415 x 190mm including PVC waste pipe but excluding taps, etc. complete all as specified and directed
Supply and fixing in repair, Vitreous China Wash Hand Basin, white, flat back, size 550 x 400 mm including brass coupling, mild steel brackets fixed to wall with pedestal etc. complete all as specified and directed.
Supply and fixing in repair, White Vitreous China wash down water closet one piece closet with integrated cistern, seat cover and twin flush fittings complete all as specified and directed.
Supply and fixing in repair, Vitreous China Squating pan 'Orissa' pattern WC size 575 x 440 mm white with integral foot rest and trap and including connection to trap, and to flushing pipe, anti-syphonage pipe, etc all as specified and directed.
Supply and fixing in repair, Viterous China wash down water closet pan (pedestal pattern) coloured including 'P' or 'S' trap with flush pipe of chromium plated brass 32 mm dia for low level flushing cistern including plastic seat cover white closed pattern with float bottom and cover and jet connection and mild steel chromium plate or aluminized hinging device complete all as specified and directed.
Supply and fixing in repair, 10 Ltr capacity PVC valve less shyphonic action type low level flushing cistern white with inlet, ball valve, float valve and handle including bracket and flush pipe of low level of 32mm dia fixed to wall complete all as specified and directed
Supply and fixing in repair, 8 mm dia brass, chromium plated health faucet (Hand shower) with 01 meter long flexible tube and wall hook complete all specified and directed.
Supply and fixing in repair, PVC connection 15mm dia size and 450 mm long with 2 Nos check nuts with washers complete all as specified and as directed.
Supply and fixing in repair, PVC Bath Cabinet made from hard thermosetting material with mirror, white/ivory colour, 400 x 500mm size complete all as specified and directed.
Supply and fixing in repair, Bib tap 15 mm bore, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
Supply and fixing in repair, brass chromium plated tubular towel rail 20 mm dia 60 cm long between flanges complete all as specified and directed.
Supply and fixing in repair, angle cock 15 mm bore fancy type chromium plated, with capstan head, high pressure, screwed down, screwed for iron pipe or for brass ferrule fixed to iron pipe complete all as specified and directed.
Supply and fixing in repair, CP two way angle valve with wall flanges 15 mm bore, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
Supply and fixing in repair 15 bore dia chromium plated concealed Angle/stop cock screwed down high pressure with crutch or butterfly handle & screw both end for iron pipe or for unions complete all as specified and directed
Supply and fixing in repair, CP, soap dish holder complete all as specified and directed.
Supply and fixing in repair, Soap Dispenser with glass bottle complete all as specified and directed.
Supply and fixing in repair, tumbler holder complete all as specified and directed.
Supply and fixing in repair, Towel ring round with round flange complete all as specified and directed.
Supply and fixing in repair, sinks with drainage board made of stainless steel 1mm thick kitchen with plugs, washers and wastes, & waste pipe including bedding in cement mortar to dwarf wall or including fixing suitable sizes of cantilever brackets and connecting union to pipe overall size 915 x 460mm, bowl size 410 x 330 x 160mm complete all as specified and directed
Supply and fixing in repair, 0.63mm thick kitchen plate rack made of stainless steel 900 x 750 x 220mm size fixing with wooden plug with suitable size of screws complete all as specified and directed
Supply and fixing in repair, chromium plated overhead shower rose swivel type 125 mm with CP arms 300 mm long complete all as specified and directed
Supply and fixing PVC (SWR) 'P' trap for 110mm dia etc. complete all as specified and directed
Supply and fixing in repair, chromium plated toilet paper holder complete all as specified and directed.
Material and labour for RCC as in kitchen platform, shelves & chajjas etc type B1 1:2:4 (20 mm graded aggregate) including necessary form work complete all as specified and directed.
Material and labour for 18-20 mm thick granite slab (of any type) work (table rubbed and polished) in cooking platforms, steps, window cills, incl edge moulding & cutting holes for gas pipe through drill machine and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc. complete all as specified and directed
Supply and fixing PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
Supply and fixing PVC (SWR) pipes 75 mm bore single socketed in any length with rubber ring joints laid in floors, trenches complete all as specified and directed.
Supply and fixing PVC (SWR) pipes 50mm bore single socketed in any length with rubber ring joints laid in floors, trenches complete all as specified and directed.
Supply and fix clamp made out of 50 x 5 mm flat iron, 16mm dia round iron stays including bolts & nuts and securing ends of stays to wall or roof for 110mm PVC pipe complete all as specified and directed.
Supply and fixing PVC (SWR) plain bend any radius for 75mm bore pipe complete all as specified and directed.
Supply and fixing PVC (SWR) bends any radius provided with access door of 110mm dia complete all as specified and directed.
Supply and fixing PVC (SWR) plain bend T (Single T) equal or unequal any radius for 110mm bore complete all as specified and directed
Supply and fixing PVC (SWR) plain bend T (Single T) equal or unequal any radius for 75mm bore complete all as specified and directed
Supply and fixing in repair, PVC (SWR) floor/ gully trap, square or round mounted, any type of size 125 x 100mm, setting and jointing with solvent cement (1:1) complete all as specified and directed
Supply and fixing in repair, cockrage trap with grating of size 100 mm x 100 mm complete all as specified and directed
Supply and fixing PVC (SWR) branch pieces, single (equal or un equal), ordinary or inverted (spigot or socket type) or with parallel branches of 110 mm dia with access door complete all as specified and directed
All as per Srl item No 105.00 above but 75 mm bore complete all as specified and directed
Supply and fixing PVC (SWR) vent cowl 110 mm bore complete all as specified and directed.
Supply and fixing in repair PVC (SWR) nahani/ floor trap, plain with grating with or without waste hole including jointing with solvent cement 75mm dia etc complete all as specified and directed.
Dismantling water tanks of capacity exc 250 but not exc 500 Ltrs complete all as specified and directed.
Dismantling water tanks of capacity exc 500 but n.exc 1000 Ltrs complete all as specified and directed
Supply and fixing 500 ltr capacity rotational moulded polyetheylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position all as per SSR Part-I other than black colour including 25mm dia overflow pipe & washout pipe complete all as specified and directed.
Supply and fixing 1000 Ltr capacity rotational moulded polyetheylene water storage tanks triple layer(cylindrical vertical with closed top) hoisted and fixed in position all as per SSR Part-I other than black colour including 25mm dia overflow pipe & washout pipe complete all as specified and directed.
Supply and fixing ball valves 20mm dia high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms) complete all as specified and directed
Supply and fixing in repair Gun metal, globe or gate valve with iron wheel head, 20mm bore, screwed both ends for iron pipe complete all as specified and directed
Material and labour for plain cement concrete (1:5:10) type E-2 using 40 mm graded stone aggregate as in filling in sunken floors including demolition of cement in concrete (unreinforced) in ground floor and pavings any thickness (below or above ground level) complete all as specified and directed.
Material and labour for Water proofing treatment to sunken floors of kitchen, toilets, laboratories, bath and WC's etc shall be as under :- (a) Application of Two component Acrylic modified cementitious coating (i) The surfaces to be applied shall be completely dry and free from containments such as dirt, dust, oil, surface treatments and old coatings. Concrete substrates must be mechanically prepared using abrasive blast cleaning or milling to remove cement laitance, existing coatings and achieve a gripping profile that is clean, dry and free from laitance and any other form of surface contamination. The installation instructions in manufacturer’s published literature should be strictly complied with, including but not limited to the following :- (ii) Chipping out any visible cracks in “V-Groove” pattern as applicable. Special attention on this part. Cleaning of cracks & then filling those cracks with SIKA latex SBR 100 putty/ Dr Fixit 302 SBR latex / Perma latex SBR / FOSROC Nitabond SBR latex / Asian Paints latex as required. Final cleaning of surface with power grinder, wire brush, hair brush & vacuum pressure if required. (iii) Dampen all surfaces immediately ahead of application of Acrylic modified Cementitious coating of Sika Top Seal – 107 / Brush Bond FOSROC/ Dr Fixit/ STP/CICO. (iv) Whilst the surface is still damp from saturation (S.S.D), apply one coat of Acrylic modified Cementitious coating of Sika Top Seal – 107 / Brush Bond FOSROC/ Dr Fixit/ STP/CICO of viscosity as per manufacturer’s instructions. (v) Apply Glass Fabric Sheet of Sika Fab 1 / FOSROC/ Dr Fixit/ STP whilst the first coat is wet. (vi) Once touch dry, apply second coat of Acrylic modified Cementitious coating of Sika Top Seal – 107 / Brush Bond FOSROC/ Dr Fixit/ STP/CICO of viscosity as per manufacturer’s instructions on the entire area. (vii) Second coat shall be applied after 6-8 Hrs of application of previous coat and in the direction right angle to the previous coat.
(viii) The waterproofing coating should be taken to a height minimum 300 mm above the finished floor level on the vertical surface. (ix) It is essential to cure Acrylic modified Cementitious coating immediately after application (minimum 6-8 Hrs drying) for a minimum of 3 to 5 days to ensure full cement hydration and to minimize cracking. (x) A protection plaster (12-15mm thick) in CM 1:3 admixed with appropriate Integral water proofing compound has to be applied on the walls. Admixture : Sika Plastocrete Plus / FOSROC / Dr Fixit / STP / CICO confirming to IS 2645. Providing and applying a protection screed of 50mm thick 1:4, cement sand mortar admixed with Sika Plastocrete over the applied water proofing coating on horizontal surfaces. Admixture : Sika Plastocrete Plus / FOSROC / Dr Fixit / STP / CICO confirming to IS 2645 (xi) All the corners and joints should be pre-treated with an elastic waterproofing sealing tape with a Woven bonding mesh on each surface and an elastic expansions zone in the centre of Make Sika Seal Tape S/FOSROC/Dr Fixit/STP. (xii) The membrane has to be protected in accordance with the manufacturer’s recommendations until placement of concrete. The membrane to be inspected for damage just prior to concrete placement and make repairs in accordance with manufacturer’s recommendations (xiii) Waterproofing treatment has to be carried out through applicators authorised
(b) All the joints of pipes and traps within the sunken portion shall be sealed properly by epoxy sealant. (c) Al CI traps in sunken slabs to be enclosed with PCC 1:1.5:3 (min 15cm) All-round. (d) The sunken portion shall be filled with PCC 1:5:10 type E-2 (using 40mm stone aggregate) complete all as specified (e) Providing drainage spout pipe GI 40 mm dia bore light grade upto outside of outer wall (Approx 450 mm to 600 mm long) including cutting to existing wall and making good the disturbed surface complete all as specified and directed. (f) Providing 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in flooring for laying floor finish all as specified. Note: Items No 116 (d), (e) & (f) shall be measured and paid separately.
Supply and fixing drainage spout pipe GI 40 mm dia bore light grade upto outside of outer wall (Approx 450 mm to 600 mm long) including cutting to existing wall and making good the disturbed surface complete all as specified and directed.
Dismantling boarding any description fixed in any position with nails complete all as specified and directed
Supply and fixing 18mm thick, PVC sheet one side pre-laminated of approved texture ("Celuca ply of Rajshree make or equivalent as in Kitchen cabinet, cub board (with shelves and partitions) including necessary fitting & fixture as per manufacturer’s instructions complete all as specified and directed
Supply and fixing modular kitchen accessories (basket/ tray/ plate racks etc) made of top quality 304 grade stainless steel, nickel chromium plates (Ni 4%) approved design and pattern complete all as specified and directed
Supply and fixing telescopic channels (exc 300mm but not exc. 500mm) complete all as specified and directed
Supply and fixing handles of 150mm including all connection fitting complete all as specified and directed
Supply and fixing cupboard locks as complete all as specified and directed
Supply and fixing stainless steel hinges including all connection fitting complete all as specified and directed
Dismantling brick tiles or terracing single layer as in roofing complete all as specified and directed
Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed.
Material and labour for 50 mm average thickness PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as roof padding, hunching, sub base floor complete all as specified and directed
Material and labour for preparation of roof surface & applying evenly a tack coat of industrial bitumen primer 85/25 grade @ 1.6 Kg/Sqm including APP based polymeric membrane minimum weighing 3 Kg/Sqm and minimum 3 mm thick reinforced with polyester non wove fabric (weight not less than 150 gms/sqm) land on primed surface by forced application, joints to be touched hot and width of overlaps shall be 75mm length wise and 100mm width wise of membrane complete all as specified and directed
Material and labour for 40mm thick brick tiles laid and joints in cement mortar (1:3) over and including 15mm thick screed bed in cement mortar 1:6 and flush pointing as work proceed complete all as specified and directed
All as per Srl item No 129.00 above but except bricks tiles complete all as specified and directed
Material and labour for damproofing to wall with two component Acrylic polymer cementitious water proof elastomeric coating four grade mix to form uniform slurry and apply with paint brush as first coat then laying a layer of fibre glass mesh cloth as first coat is still green with overlap of joints of fibre mesh not less than 100 mm, then finally apply second layer mix by brush to entire surface of container covering 0.6 - 0.75 Sqm /Kg at 1 mm thickness in two coat depending on the level of substrate and curing it for minimum 3 days. Note : Quoted rate shall be deemed to be inclusive of materials all labours, tools and plants, scaffolding and working upto height 6 metre etc. Make : Pidilite Industries Ltd/ Fosroc India Ltd/ IWL India Ltd, BASF/T-Guard ANTC of Make - Trermax, complete all as specified and directed.
Material and labour for cement concrete (1:2:4), type B0, using 12.5 graded stone aggregate in roof kerbs coved fillets of 75mm radius at junction of roof slab and parapet wall, vertical surfaces and like etc complete all as specified and directed
Cutting chases, pinning in brick walls /stone concrete block or slab walls, making good to facings where required using expended metal in required size & pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc; & cutting chases for concealed water tubing or concealed conduit wiring, etc. & making good, cutting exc 10cm but not exceeding 20cm girth complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5m depth in soft/loose soil etc complete all as specified and directed. Breakdown of Qty B/R-242.88 Cum E/M-336.15 Cum
Returning, filing in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm etc complete all as specified and directed. Breakdown of Qty B/R-218.59 Cum E/M-195.64 Cum
Removal of excavated materials not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed. Breakdown of Qty B/R-24.29 Cum E/M-140.51 Cum
Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortar for 150mm internal dia of pipe complete all as specified and directed
Material and labour for laying DWCP 150mm dia pipes in trenches Class SN-8 conforming to IS 16098 (Part -2) in 6 mtr length with coupler complete all as specified and directed
Material and labour for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 150mm bore of pipe with cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate complete all as specified and directed
Material and labour for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 150 mm internal dia of pipe complete all as specified and directed.
Supply and fixing ornamental stainless steel tubular pipes/ sheets, pieces such as pipe caps globe at top 18 gauge and grade 304 as in staircase railing including welding, moulding riveting nut and bolt with all necessary fittings complete all as specified and directed
Material and labour for preparation of old painted surfaces of steel of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed
Taking down steel gate exc 2 Sqm but n.exc 12 Sqm any weight and refixing in the same opening on bearing after repairing, painting of gate and making good disturbed portion complete all as specified and directed
Dismantling wrought iron or mild steel work of any description complete all as specified and directed
Supply and fixing framed work as in doors or gates of angle or other section with gusset plates, rails, braces staircase etc. complete drilled for fixing of steel gate sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing confirming to Fe-290 (Gde E-165) complete all as specified and directed
Material and labour for Welding in repairs not exc 2.5 cm in length complete all as specified and directed.
Supply only angle Iron / MS plate / MS sheet for welding where ever required for repair work complete all as specified
Material and labour for preparation of newly steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
Material and labour for RCC 1:1.5:3, type A1, using 20mm graded stone aggregate as in suspended slabs supported on walls/columns, in floors, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use and waste of form work to soffit of suspended slabs such as roof slabs, floor slabs, landings and similar works not exceeding 20cm thick and rough finished surfaces of concrete all as specified and directed
Supply and fixing mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
Supply and fixing Mild steel TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
Removing building materials upto to a distance of 1.00 Km or under, including loading, unloading and stacking at the destination complete all as directed by Engineer-in-Charge
E/M WORKS
Taking down carefully existing point wiring of any type (i.e. on wooden batten, surface conduit, casing capping or concealed conduit except existing concealed conduit) complete for light, fan, socket or power point with fittings and fixtures such as ceiling rose, electric fittings, holders, switches, sockets wooden batten, conduit etc including accessories such as wooden gutties/ rawal plug, screw etc including removing materials from site for taking credit of unserviceable items and re-fixing the serviceable items as per schedule and making good disturbed surface of walls, floors etc, complete all as specified and directed. Notes :- (i) The existing conduit of concealed wiring will not be removed from site and same will be reused for point wiring under respective item hereunder. (ii) The qty of serviceable/ unserviceable items will be ascertained by the BOO detailed by GE and serviceable items (such as LED fittings/LED tube and bulb /ceiling/ Exhaust Fans and geysers) will be re-fixed under respective item hereunder and unserviceable items such as switches, sockets, ceiling rose, holders, brackets, bulkhead fittings, LED fittings, MCB DBs, sunken boxes and fixtures etc. shall be issued to contractor under schedule of credit all as specified and directed.
Material and labour for point wiring with 1.5 sqmm, PVC insulated but unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through existing metallic/ rigid PVC concealed conduit including replacement of pressed steel terminal mounting box for mounting fitting like P/T switches, sockets, and providing covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated( green colour) 1.50 sqmm size copper conductor cable as a earth wire and connected to common earth dolly for one light/ one fan/ one bell point controlled by one, one way switch complete all as specified and directed. (For JCO/ORs Md Accn against the existing points)
All as per Srl item No. 156.00 above but one light point controlled by two Nos of two way switch
All as per Srl item No. 156.00 above but one socket outlet point 5 amps on the same board
All as per Srl item No. 156.00 above but one socket outlet 5 pin 5 Amp controlled by one, one way switch on independent board
All as per Srl item No. 156.00 above but wiring with using cable 2.5 Sqmm size copper wire (FRLS) and earth wire of PVC insulated (Green colour) 2.5 Sqmm size copper wire for one 6 pin socket outlet, 16 Amp on independent board
Material and labour for point wiring with 1.5 Sqmm, PVC insulated but unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through existing metallic/ rigid PVC concealed conduit including replacement of pressed steel terminal mounting box , for mounting fitting like modular switches, sockets, and fixed with brass screws and cup washers including one continuous run of PVC insulated 1.50 Sqmm size copper conductor cable green in colour as an earth wire and connected to common earth dolly for fan point/ exhaust fan point/ one light point/ bell/ buzzer controlled by one switch/ bell push complete all as specified and directed. (For Officer Md Accn against existing points) Note : Cost of Metal boxes and modular accessories like cover plates will be paid separately in respect items
All as per Srl item No. 161.00 above but one light point controlled by two Nos of two way switch
All as per Srl item No. 161.00 above but one socket outlet point 5 amps on the same board.
All as per Srl item No. 161.00 above but one socket outlet point 5 amps on the independent board.
All as per Srl item No. 161.00 above but with 2.5 Sqmm wire and earth wire of 2.5 Sqmm for 3 Pin 15 Amp modular type socket outlet
Material and labour for Point wiring complete with 1.5 Sqmm (nominal area), FRLS PVC insulated unsheathed and stranded copper conductor cable ISI marked drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonry wall for fixing conduit and plastering the external surfaces and matching the same with existing surface) and pressed steel terminal boxes of thickness not less than 1.2 mm for mounting fitting like P/T switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of FRLS PVC insulated green in colour 1.50 Sqmm size copper conductor cable as earth wire and connected to common earth dolly for one light/ one fan/ one bell point controlled by one, one way switch complete all as specified and directed. (For JCO/ORs Md Accn against new SOA 2022 and existing unserviceable and dismantle conduit points)
All as per Srl item No. 166.00 above but one light point controlled by two Nos of two way switch
All as per Srl item No. 166.00 above but one socket outlet 5 pin 5 Amp controlled by one, one way switch on same board
All as per Srl item No. 166.00 above but one socket outlet 5 pin 5 Amp controlled by one, one way switch on independent board
All as per Srl item No. 166.00 above but wiring with using cable 2.50 Sqmm size copper wire FRLS and earth wire of PVC insulated (Green colour) 2.50 SQMM size copper wire for one 6 pin socket outlet, 16 Amp on independent board
Material and labour for point wiring with 1.5 Sqmm, PVC insulated but unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non-metallic rigid PVC concealed conduit medium grade 20mm dia (minimum) or higher size as specified and cutting chasing on wall complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc/ fittings ISI marked for modular fittings and brass screws and cup washers including 1.5 Sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories for fan point/ exhaust fan point / one light point / bell/ buzzer controlled by one switch/ bell push complete all as specified and directed. (For Officer Md Accn against new SOA 2022 and existing unserviceable and dismantle conduit points) Note : Cost of Metal boxes and modular accessories like cover plates will be paid separately in respect items.
All as per Srl item No. 171.00 above but one light point controlled by two Nos of two way switch
All as per Srl item No. 171.00 above but one socket outlet point 5 amps on the same board
All as per Srl item No. 171.00 above but one socket outlet point 5 amps on the independent board
All as per Srl item No. 171.00 above but with 2.5 Sqmm wire and earth wire( green colour) of 2.5 Sqmm for 3 Pin 15 Amp modular type socket outlet
Supply and fixing modular metal flush box made out of GI sheet, thickness not less than 1.2mm with earthing terminal, 1/2 module complete all as specified and directed.
Supply and fixing modular metal flush box made out of GI sheet, thickness not less than 1.2mm with earthing terminal, 3 module complete all as specified and directed.
Supply and fixing modular metal flush box made out of GI sheet, thickness not less than 1.2mm with earthing terminal, 4 module complete all as specified and directed.
Supply and fixing modular metal flush box made out of GI sheet, thickness not less than 1.2mm with earthing terminal, 6 module complete all as specified and directed.
Supply and fixing modular metal flush box made out of GI sheet, thickness not less than 1.2mm with earthing terminal, 8 module complete all as specified and directed.
Supply and fixing modular metal flush box made out of GI sheet, thickness not less than 1.2mm with earthing terminal, 12 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame, 1 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame, 2 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame, 3 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame, 4 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame, 6 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame, 8 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame, 12 module complete all as specified and directed.
Supply and fixing modular Dummy plate complete all as specified and directed.
Supply and fixing Modular switch 6 Amp 1 way 1 module size complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing modular switch 6 Amp 2-way 1 module complete all as specified and directed by Engineer-in-Charge
Supply and fixing Modular switch 16 Amp 1 way with indicator 1 module size complete all as specified and as directed by Engineer-in-Charge
Supply and fixing Modular socket shuttered 6 Amp 2/3 pin combined 2 module size complete all as specified and as directed by Engineer-in-Charge
Supply and fixing Modular socket 16Amp multipurpose type 2 module size complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Modular Fan regulator step type 120 watts 2 Module size complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Modular bell switch 6 Amp 1 module size complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing switch piano flush button single pole one-way 5 Amp complete all as specified and directed.
Supply and fixing switch piano flush button single pole Two-way 6 Amp complete all as specified and directed.
Supply and fixing socket outlet 5 Amp, 2 and 3 pins (TOTAL 05 PINS), flush type 250 volts AC complete all as specified and directed.
Supply and fixing switch piano flush button single pole one-way 15 Amp complete all as specified and directed.
Supply and fixing socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amps flush type, 250 volts AC complete all as specified and directed.
Supply and fixing fan regulator electronic step type socket size and making all necessary connections complete all as specified and directed.
Supply and fixing Ceiling rose, surface bakelite 3 terminal, 240 volts, 5 Amps with back plate of 3 mm thick bakelite, laminated hylem sheet of appropriate size ,complete ,all as specified.
Supply and fixing lamp holder, PVC / polycarbonate type insulated body with back plate suitable for batten / angle fittings including led lamp 9 watt complete all as specified and directed.
Supply and fixing decorative wall light fixture made of polycarbonate type insulated body with back plate suitable for Led lamp B22 base including led lamp 9 watt complete all as specified and directed.
Supply and fixing single phase call bell ‘DING DONG’, AC 230 volts single pole fixed over and including pressed steel sunk box of size 175 X 100 mm duly covered with 3 mm thick bakelite sheet complete all as specified and directed.
Supply and fixing bell push, flush type, single pole 5 amps complete all as specified and directed.
Supply and fixing MCB single pole, 240 volts, 6 to 32 Amp, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed.
Supply and fixing MCB single pole, 240 volts, 6 to 32 Amp, rupturing capacity 10 KA, ‘C’ curve type complete all as specified and directed.
Supply and fixing MCB SPN, 240 volts, 40 to 63 Amp, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed.
Supply and fixing sheet metal enclosure for DB’s (Double door type) when MCB’s to be used, single pole and neutral, 12 ways with 200 Amp rated bus bar, 240 volts fixed sunk / flush to the wall with IP-43 and IK-09 protection complete all as specified and directed.
Supply Install, testing and commissioning LT Distribution Panel (CPRI Approved) cubicle type IP-56 wall mounted, indoor type conforming to IS-5039 of 1983, factory fabricated made out of 2mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories/ fittings compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulated with colour coated heat shrinkable sleeve and shall be mounted on DMC supports. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC and having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall colour coated sleeves. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painted with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment , front & back opening type, and fixing 2 Nos danger notice plate with letter , figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following (For Officer Md Accn) :- (a) Aluminium Bus bar for 3 phase 4 wire system of 4X 150 A rated insulated copper strip mounted on resin cast insulator in independent compartment having front openable shutter - One Set. (b) MCCB, four pole, 415 Volt, 100 Amps, 25 KA with adjustable overload setting - 01 No. (c) MCB DP 40 to 63 Amp ,10KA -04 Nos (d) MCB SP 10 A - 01 Nos (e) Indicator lamp LED in Red/Yellow/Blue colour- one set of three . Note :- (i) The LT panel board will be fixed to the wall in the place of existing U/S panel Bd with suitable no of fastener and lugs, PVC insulated connectors , PVC sleeves including necessary civil work reqd to re-fix the panel as per std Engg practice and make the good disturbed surface to match with existing specification of wall.
(ii)Taking down of 4 Nos old serviceable meter, recording of meter reading and re-fixing the same meter in new panel in their respective qtr is included in quoted rate. (iii) LT panel Board should be of make having valid CPRI type tested approved and as per IS-5039 of 1983. (A copy of valid CPRI type test report to be enclosed while obtaining approval from GE). (iv) SLD diagram for LT Panel will be got approved from GE before placing the order and final diagram will be fixed on the front and rear door. (v) Rate for the same is deemed to included in the quoted rates.
Supply Install, testing and commissioning LT Distribution Panel (CPRI Approved) cubicle type IP-56 wall mounted, indoor type conforming to IS-5039 of 1983, factory fabricated made out of 2mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories/ fittings compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulated with colour coated heat shrinkable sleeve and shall be mounted on DMC supports. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC and having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall colour coated sleeves. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painted with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment , front & back opening type, and fixing 2 Nos danger notice plate with letter , figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following ( For JCO/OR Md Accn ) :- (a) Aluminium Bus bar for 3 phase 4 wire system of 4X 100 A rated insulated copper strip mounted on resin cast insulator in independent compartment having front openable shutter - One Set. (b) MCCB, four pole, 415 Volt ,63 Amps,25 KA with adjustable overload setting - 01 No. (c) MCB DP 40 to 63 Amp ,10KA -04 Nos (d) MCB SP 10 A - 01 Nos (e) Indicator lamp LED in Red/Yellow/Blue colour- one set of three. Note:- (i) The LT panel board will be fixed to the wall in the place of existing U/S panel Bd with suitable no of fastener and lugs, PVC insulated connectors , PVC sleeves incl necessary civil work reqd to re-fix the panel as per std Engg practice and make the good disturbed surface to match with existing specification of wall.
(ii) Taking down of 4 Nos old serviceable meter, recording of meter reading and re-fixing the same meter in new panel in their respective qtr is included in quoted rate. (iii) LT panel Board should be make having valid CPRI type tested approved and as per IS-5039 of 1983. (A copy of valid CPRI type test report to be enclosed while obtaining approval from GE). (iv) SLD diagram for LT Panel will be got approved from GE before placing the order and final diagram will be fixed on the front and rear door. (v) Rate for the same is deemed to included in the quoted rates.
Material and labour for sub main wiring with 1100 volt grade two single core FRLS Wire PVC insulated and unsheathed cable with stranded copper conductor 10 Sqmm drawn into and including electrical grade PVC conduit not less than 25mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 10 Sqmm multi-stranded copper conductor as earth wire in green colour Including taking down old unserviceable sub main wiring complete all as specified and directed. Note : Two runs of 10 Sqmm PVC FRLS multi stranded copper cable wire and One run of 10 Sqmm PVC FRLS multi stranded copper cable earth wire and One run PVC conduit of suitable size ISI mark will be measured and one unit length
Material and labour for sub main wiring with 1100 volt grade two single core FRLS Wire PVC insulated and unsheathed cable with stranded copper conductor 6 Sqmm drawn into and including electrical grade PVC conduit not less than 25mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 6 Sqmm multi-stranded copper conductor as earth wire in green colour including taking down old unserviceable sub main wiring complete all as specified and directed. Note : Two runs of 6 Sqmm PVC FRLS multi stranded copper cable wire and One run of 6 sqmm PVC FRLS multi stranded copper cable earth wire and One run PVC conduit of suitable size ISI mark will be measured and one unit length
Material and labour for sub main wiring with 1100 volt grade two single core FRLS Wire PVC insulated and unsheathed cable with stranded copper conductor 4 Sqmm drawn into and including electrical grade PVC conduit not less than 25mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 4 Sqmm multi-stranded copper conductor as earth wire in green colour including taking down old unserviceable sub main wiring complete all as specified and directed. Note : Two runs of 4 Sqmm PVC FRLS multi stranded copper cable wire and One run of 4 Sqmm PVC FRLS multi stranded copper cable earth wire and One run PVC conduit of suitable size ISI mark will be measured and one unit length
Supply and fixing in replacement of LED tube light fitting for all purpose surface and wall mounted with single side connection polycarbonate LED batten with polycarbonate housing and integrated electronic driver of capacity 18 W, four feet and connection with PVC insulated twin core 23/0.0076 twisted copper cable from ceiling rose to tube light fitting complete all as specified and directed. Make: Havells cat part No. LUMILINEEOBS18WLED865SPCWH or equivalent make as mentioned in Appx 'B'
Fixing only serviceable LED Tube light fitting 18/20/22 watts, as per item Srl No. 155 after B/R repairs and making electrical connection complete all as specified and directed
Supply and fixing wall/ ceiling mounting LED 9/10 Watt tube light fitting with polycarbonate housing and integrated electronic driver complete with all accessories 1x9 Watt LED, with CCT of 6000k suitable for domestic application, 240 Volts, 50 Hz, and internally pre-wired with 1.5 Sqmm twin twisted flexible cable copper conductor and connection complete all as specified and directed. Make: Havells cat part No. LUMILINEBS9WLED865SPCWH or equivalent make as mentioned in Appx 'B'
Supply and fixing energy saving new generation 10 watt LED built up, 6000k bulk head luminaire with opal diffuser light fitting complete with all accessories and connection complete. Make : Havells cat part No. RUGBYGENXFTS10WLED865SSYMBOPC or equivalent make as mentioned in Appx 'B'
Supply and fixing in replacement of security light fitting LED 35 Watt with dusk and dawn sensor aluminium pressure dia cast housing with touched glass cover IP-66 protection including suitable size GI Bracket and accessories complete mounted including connection with 3 core PVC insulated overall sheathed flexible cable with multi-stranded copper conductor of size not less than 1.0 Sqmm from ceiling rose to fitting terminal including taking down old CFL security light fitting all as specified and as directed.
Material and labour for earthing complete with galvanised earth plate electrode 600 X 600 X 6mm thick buried directly in ground (earth pit not less than 2.25m below ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part-I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6mm dia mild steel round bars @ 150mm both ways centre to centre with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1, GI protection pipe light grade 15mm bore up to 7.5m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200 X 150 X 15mm & painting of earth result etc. including testing on complete all as specified and directed. Notes :- (i) Earth lead and protection pipe beyond 7.5 m shall be measured and Paid separately. (ii) On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
Material and labour for laying of LT cable of 1100 volt XLPE insulated and PVC sheathed of size 35 Sqmm 3.5 core with cable gland including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge. ( For Officer Md Accn)
Material and labour for laying of LT cable of 1100 volt XLPE insulated and PVC sheathed of size 25 Sqmm 4 core with cable gland including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge.( For JCO/OR Md Accn)
Material and labour for brick protection to cable using old size sub class 'B' bricks, laid flat, dry butt jointed, laid lengthwise perpendicular to the axis of cable all as specified & directed
Material and labour for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after lying of cable in trenches complete all as specified & directed. Note : Punned down thickness shall be measured for payment.
Material and labour for boring of hole under road for passing of electric cable including double wall corrugated (DWC) pipes made of high density polyethylene (HDPE) of size 75mm outer dia and 61mm inner dia complete all as specified and directed
Supply and fixing /laying galvanised pipe 50 mm bore medium grade fixed to pole with clamps nuts, bolts and washers or laid under road crossing or fixed to wall complete all as specified and directed.
Supply and fixing high speed wall mounted fan of sweep size 300 mm complete with wide oscillation with motorised control including fitting and fixtures as per site requirement and two core PVC insulated, PVC sheathed copper conductor for connection all as specified and directed.
Supply and fixing fresh air fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230 V, 50 Hz, RPM 1200, copper winding of sweep 250 mm size including cutting opening and fixing/grouting of frame in wall complete and connection with and including PVC insulated multi-stranded wire complete all as specified and directed by Engineer-in-Charge
Fixing only of geyser (Electric Water heater storage type) of capacity 25 Ltr, kept in safe custody as per srl No. 155, after B/R repairs. Note: Cost of minor petty items if required such as nut bolt/PVC pipe is included in quoted rate
Supply and fixing electric water heater, storage type steel body with SS 304 inner tank and heating element upto 2 KW capacity 25 litre, BEE , 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection pipes etc. all as specified and directed
Fixing only ceiling fan 1200/1400 mm size, as per item srl No. 155 after B/R repairs all as specified and directed. Note: Cost of minor petty items if required such as nut bolt/clamp is included in quoted rate
Fixing only exhaust fan/ fresh air, kept in safe custody as per item srl No. 155 after B/R repairs all as specified and directed. Note: Cost of minor petty items if required such as nut bolt/ clamp is included in quoted rate
Supply and fixing exhaust fans metal body of 300 mm sweep, 1400 RPM, heavy duty, ISI marked suitable for single phase 230 V/250 V, 50 Hz AC supply complete including cutting opening and fixing/grouting of frame in wall complete and connection with and including PVC insulated, unsheathed FRLS cable with multi-stranded copper conductors from ceiling rose to fan complete all as specified and directed
Supply and fixing sheet metal enclosure (plug & socket type DB) complete including single pole and neutral enclosure with two pin, earth plug and socket complete with one SP MCB C Curve type of capacity 20 Amp, 10 KA all as specified and directed.
M/S ANIL KUMAR
NARINDER KUMAR SONS
A.V BUILDERS
NAFREF ENGINEERS PVT LTD
Megha Construction Co.
Shekhar Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .