Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹63.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹69.8 L+₹6.8 L (10.8%)Rejected-Finance 62 A GANDHI NAGAR JAMMU DISTRICT JAMMU PIN 180004 JAMMU KASHMIR | JAMMU | JAMMU AND KASHMIR | 180004 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹80.0 L+₹17.0 L (27.0%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹80.6 L+₹17.6 L (28.0%)Rejected-Finance | L4 | Rejected-Finance BEING L4 | |
| 5 | Not Admitted-Fee/PreQual/Technical 415 A GANDHI NAGAR JAMMU J K PIN 180004 | JAMMU | JAMMU AND KASHMIR | 180004 | - | Not Admitted-Fee/PreQual/Technical Others-Firm under suspension period for Banning of Business Dealings with NHPC Ltd |
Tender Value
₹71.4 L
EMD Value
₹1.4 L
Closing Date
11 Mar 2024, 5:00 pmClosed
General Manager Procurement and Contract
PnC Division Salal Power Station NHPC Limited Jyotipuram Reasi UT of JandK
ReWiring of Admin Building II, GM Office at Salal Power Staion, Jyotipuram
2024_NHPC_791247_1
NH/SPS/CD/NIT21/23-24/909-919
Open Tender
Electrical Works
Item Rate
184 days
Salal Power Station Jyotipuram
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,180
NHPC LIMITED
₹1.4 L
Yes
13 May 2024
20 Jan 2024
15 Mar 2024
20 Jan 2024
11 Mar 2024
20 Jan 2024
Amount
Supply of PVC Insulated and PVC Sheathed/ XLPE Power Cable of 1.1 KV grade of 3.5 Core 300 Sq mm Aluminum Conductor cable on wall surface as required.
Laying & fixing of PVC Insulated and PVC Sheathed/ XLPE Power Cable of 1.1 KV grade of 3.5 Core 300 Sq mm Aluminum Conductor cable on wall surface as required.
Supply & Installation of Main Distribution Board Panel, comprising of 2 Nos 400 A, I/Comer 6 Nos 200 Amp O/g feeder with 4 pole MCCB's, Bus Bar, 1 No 3 LCD Phase Energy Meter along with CT suitable for above, 8 Nos of 3 Phase Multifunctional meters along with CT suitable for above, 3 Nos LED Phase indicators etc. as required, (as per drawing enclosed)
Supplying and fixing of 8 way (4 + 24), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.
Providing and fixing 100 A, 16kA, TPMCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
Supplying and fixing 16 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 12 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing Single Pole 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40A rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the 4 X 16 sq. mm + 2 X 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 6 sq. mm + 1 X 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 4 sq. mm + 1 X 4 sq. mm earth wire sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Supplying & Drawing UTP- 4 Pair Cat 6 LAN Cable in the surface/recessed PVC conduit medium class PVC conduit as required
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required (GROUP C)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 1 No 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch & 1 Nos 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 Nos 5/6 amps modular socket outlet and 3 Nos 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 1 No RJ-45 Jack Cat 6 (for LAN) modular socket outlet, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 1 Nos 5/6 amps modular socket outlet and 1 Nos 5/6 amps modular switch, connection etc. as required.
Supply & Installation of exhaust fan-12" in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing Modular Stepped type electronic Fan Regulator including connection etc. as required.
Supplying and making end termination with brass compression gland and aluminium lugs for 3½ X 300 sq. mm (70 mm) of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required.
Supply and fixing 63 Amp rating, double pole single phase and neutral) 240 Volt resudual current circuit breaker(RCCB) having the 30 Main the exisiting MCB DB complete with connection, testing and commissioning etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required
Earthing with copper earth plate 600mmX600mm x 3 mm thick including accesories and providing masonary enclosure with cover plate with locking arranment with watering pipe with 2.7 mtr longh.
Providing and fixing 25 mmX 5 mm copper strip on surface or in receces and connection as required.
Supply and fixing PVC batten/angle holder including connection etc as required.
RL SHARMA
JK Electric Engineers Pvt. Ltd.
JP Infratech
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .