| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-Finance | ₹5.9 L | L1 | Accepted-Finance Qualified as L1 |
| 2 | L2₹6.1 L+₹19,423 (3.29%)Accepted-Finance | ₹6.1 L+₹19,423 (3.29%) | L2 | Accepted-Finance Qualified as L2 |
Tender Value
₹5.7 L
EMD Value
₹11,457
Closing Date
2 Apr 2024, 3:00 pmClosed
O/o the Executive Engineer (E), BSNL, Bhubaneswar
O/o the Executive Engineer (E), BSNL, Bhubaneswar Door Sanchar Bhawan, Unit-IX, Bhubaneswar-751022
Electrical Repairing of BSNL Staff Quarters under Bhubaneswar BA.
2024_BSNL_192229_1
150/BSNL-EDB/2023-24
Open Tender
Electrical Works
Item Rate
365 days
Bhubaneswar BA
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
A O (Cash), BSNL, O/o GMTD, Bhubaneswar.
₹11,457
Yes
6 Nov 2024
22 Mar 2024
3 Apr 2024
22 Mar 2024
2 Apr 2024
22 Mar 2024
22 Mar 2024 - 30 Mar 2024
Amount
Checking, testing and attending minor faults of the fans, fittings, switches, MCBDBs, meter boxes and Service connection cable etc. of the newly allotted staff Quarters and switching on the power supply to the staff quarters etc. as required.
Replacement of the burnt out wires /wirings by the following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1 x 1.5 sq. mm
2 x 1.5 sq. mm
3 x 1.5 sq. mm
6 x 1.5 sq. mm
2 x 4 sq. mm
3 x 4 sq. mm
4 x 4 sq. mm
2 x 6 sq. mm
3 x 6 sq. mm
Replacement of damaged conduits by the following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Replacement of modular type switch boards by following size/ modules, GI box (at least 1.2mm thick) along with modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75 mmX75 mm)
3 Module (100 mmX75 mm)
4 Module (125 mmX75 mm)
6 Module (200 mmX75 mm)
8 Module (125 mmX125 mm)
12 Module (200 mmX150 mm)
Replacement of faulty switches and sockets by following modular / Piano type switch/ socket on the existing modular plate/switch box including connections but excluding modular plate etc. as required.
6/10 A One way Modular switch
3 pin 6/10 A Modular socket
16/20A Modular switch
6 pin 16/20A Modular socket
6A Piano type Switch
15/16A Piano type Switch
6A 3 pin Piano type Socket
15/16A 5/6 pin Piano type Socket
Modular type Bell push
Replacement of faulty fan regulators by new ones of two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Painting of ceiling fan in installed position with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent etc. as required.
Rewinding of 1200mm/1400mm ceiling fan by superior quality super enameled copper conductor i/c heat varnishing, testing etc. as required.
Overhauling of Ceiling Fan i/c dismantling, heat varnishing of windings, greasing of bearings, refitting, testing etc. as required.
Replacement of the defective Capacitors / Fan regulators/ bearings for ceiling fans etc. by the new one of following ratings etc. as required. (Make- Anchor/Havells/Cona/ISI)
2.25 mfd 440 volts Capacitor for Ceiling Fan
Bearings for Ceiling fans (6201 & 6202) etc. as required. (Make: SKF/SS)
Ceiling Fan hanging Clamp with nuts and bolts
Replacement of damaged and life expired ceiling fans by new ones of 1200 Ceiling Fans for the Officers Quarters i/c installation, connection and testing etc. as required. (Havells Elegant White Or Equivalent of Usha/Bajaj/Crompton)
Replacement of faulty / damaged and life expired exhaust fans by new ones of 200 polycarbonate Exhaust Fans for the Officers Quarters i/c installation, connection and testing etc. as required. (Havells Veltil Air DX HS Or Equivalent make of Usha/Bajaj/Crompton)
Replacement of faulty Energy meters of staff quarters by new factory tested, direct connected type 1 phase 2 wire Digital energy meter of rating 10-60 amp, accuracy class-1.0, suitable for operation on 230/240V (P-N), 50 Hz+5% AC supply, operating temperature range from +55 deg C to -10 Deg C, protection class of IP-51 compliance to IS-13779, IEC-62052-11 and IEC-62053-21 with engineering plastic enclosure and provision for sealing of mains and terminal covers, etc.as reqd. (Make L&T EM101/equivalent model of Secure/Siemens)
Replacement of faulty main switches by new 32 Amps 240 volts SPN main switch on existing angle frame/surface of wall/board i/c connection etc. as required.
Replacement of faulty and damaged FTL fittings by new one of following ratings, 65000K LED Batten suitable for operation on 140 volts to 270 volts AC, 50Hz i/c fixing and connection etc. as required. (Havells /Phillips / Surya / Polycab / Crompton)
20/22 watt 65000K LED Batten Polycarbonate/Aluminium body
18 watt 6500K LED panel (Round/Square) (Trim Clipon LED panel of Havells/SS)
Polycarbonate Bulk head fitting with 6.5 watt 6000K LED lamp
15 watt BC LED Lamp
Angle/batten Holder
Ceiling Rose
Replacement of damaged distribution board enclosures by following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make-Legrand/L&T/Siemens/Schneider)
8 way, Double door
12 way, Double door
Replacement of faulty MCBs by new 6A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make-Legrand/L&T/Siemens/Schneider)
Single pole
Double pole
Replacement of faulty Isolators by following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 A Double Pole
63 A Double Pole
63 A Four Pole
100 A Four Pole
Replacement of faulty and damaged street light fittings by following watt LED street light fitting made up of pressure diecast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening separate driver compartment with IP66 protection and impact resistance of IK08. (Make: Havells / Phillips/Crompton/Bajaj)
Replacement of damaged loop in and loop out boxes by SMC Junction box of size 200mm x 140mm x 95mm (inside dimensions) with hinged door type including supply and fixing of 1no. 4 pole stud connector with nuts and bolts etc. as required. (Sintex GSJB2014/SS)
Replacement of damaged compound light brackets by 32 mm dia X 1.5metres long G.I. pipe (medium class) bracket along with 2 nos. 40 mm X 3 mm flat iron clamps with nuts, bolts and washers for mounting of street light fitting on pole including bending the pipe to the required shape, painting the clamps with primer and finish paint etc. including cost of all materials as required; complete all as directed by Engineer-in-charge.
Replacement of faulty Service connection cables by new one of 2 core X4sqmm PVC insulated and PVC sheathed Aluminium conductor weather proof cable etc. as required.
Replacement of faulty electrical cables by following sizes PVC insulated & PVC sheathed Aluminium conductor armoured cable 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 i/c transportation to respective sites etc. as required for replacement of faulty/burnt out cables.
2 core 6 sqmm
4 core 10 sqmm
4 core 16 sqmm
4 core 25 sqmm
3.5 core 50sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Up to 35sqmm
Above 35 sq. mm and upto 95 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Up to 35sqmm
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size Up to 35sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
Up to 35sqmm
Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size Up to 35sqmm in the existing Duct/Air as required.
Up to 35sqmm
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Replacement of damaged MV cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 X 6 sq. mm (19mm)
4 X 16 sq. mm (28mm)
4 X 25 sq. mm (28mm)
3½ X 50 sq. mm (35mm)
SRIKANTA KUMAR DAS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .