| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
17 Jan 2020, 2:00 pmClosed
Er. A.K. Chhibber
Office of the Deputy General Manager, JKPCC Ltd., Unit Electrical, Rail Head Complex Jammu.
Internal Electrification of Remaining portion at Forest Resource and Management Bhavan, Narwal Jammu
2019_PWDJK_88995_1
e-NIT NO 14/ELECT of 2019-20 Dt. 24-12-2019
Open Tender
Electrical Works
Item Rate
365 days
JAMMU
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
Financial Controller, JKPCC Ltd.
₹29,000
Yes
O/o General Manager, JKPCC Ltd., Jammu
17 Feb 2020
24 Dec 2019
20 Jan 2020
24 Dec 2019
17 Jan 2020
4 Jan 2020
3 Jan 2020
Amount
WIRING Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Group B
Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 4 Pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
3 Pin 5/6 A socket
15/16 A switch
6 Pin 15/16 A switch
Telephone socket outlet
TV antenna socket outlet
Bell push
Supplying and fixing fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 3 Module (100 mmX75 mm)
6 Module (200 mmX75 mm)
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
supply, Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required 18 Watt
Supply, Installation, testing and commissioning of ceiling fan 1200 mm five star rating, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supply, Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Supplying and fixing PVC batten/ angle holder including connections etc. as required along with 9 watt LED Lamp
P/F OF MCCB, MCB & DB'S Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole 6-32 A
Triple pole and neutral 40/63 A
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door TPN
Providing & Fixing of 32 A DP Switch
Providing & Fixing of LED 1' Mirror Fittings
Providing & fixing of Main LT Panel with Incomer 250 A, 4 Pole , 50 KA MCCB = 1 No. outging 63/40 A , MCCB , Pole =5 Nos., Changeover switch=125 A, 4 Pole =1 No. Panel should be =3'x3'x1'6"
Providing & Laying of LT Cable 3.5 Core 120 sq. mm
Electromechanics Engineers And Contractors
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .