| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC 00 PANCHARIYA NEAR SANTOSHI MATA TEMPLE MAHARASHI GOUTAM MARG NEW LINE GANGASHAHAR BIKANER BIKANER BIKANER RAJASTHAN 334401 | BIKANER | RAJASTHAN | 334401 | L1 | Accepted-AOC BEING LOWEST AFTER CONSIDERING SCH OF CREDIT AND DISCOUNT AS APPLICABLE. | |
| 2 | L2₹41 L+₹5.6 L (15.7%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
27 Jul 2022, 6:00 pmClosed
CWE JABALPUR
HQ CWE JABALPUR OPPOSITE SUPPLY DEPOT SADAR 482001
COMPREHENSIVE MAINTENANCE OF CENTRAL AC PLANT OF MILITARY HOSPITAL OF PH-II AND PH-III AND STATION MDC UNDER GE (W) JABALPUR
2022_MES_535212_1
81960/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
JABALPUR
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE WEST JABALPUR
₹90,000
Yes
17 Oct 2022
1 Jul 2022
29 Jul 2022
1 Jul 2022
27 Jul 2022
15 Jul 2022
1 Jul 2022 - 14 Jul 2022
Amount
Comprehensive periodic maintenance, repair & servicing of central Air Conditioning Plant of Make : Carrier of capacity 3 x (2 x 175) TR model:30 HXC 190 A and ventilation system existing at Military Hospital Jabalpur as per manufacturers instructions and as directed by Engr-in-Charge :- Main equipments to be maintained/ serviced are listed below :- (a) Preventive and comprehensive repair, maintenance, servicing through authorised dealer of company for 3 Nos of chilling machine of screw type compressor 350 TR, 3x ( 2 x 175)TR each single stage, 3000 RPM, 415 Volts, 3 Phase, 50 Hz, semihermatic electric motor of capacity 80 KW, shell and tube type condensor with carbon steel plate, copper tube, externally and internally to pass water flow 1400 USG/ PM, including carbon plate shell and tube flooded type chiller unit working with microprocessor based controls in sheet metal control panel etc Make : M/s Carrier Co. Note:- Refrigerant and compressor oil as and when in the opinion of Engr-in-Charge is required to be replaced, same shall be replaced immediately and cost of the same shall be deemed to be included in the unit rates quoted by the contractor. (b) Other associates parts/accessories :- (i) Condensing pump set with motor of capacity 30 KW/40 HP, 1450 RPM, 50Hz, pump head 26.5 Mtr - 02 Sets (Motor of make ALSTOM and Pump of make Kirloskar).
(ii) Chiller motor pump set complete of capacity 30 KW/ 40 HP, 1450 RPM, 50Hz, total head of pump 26.5 Mtr- 02 Sets (Motor of make : ALSTOM and Pump of make : Kirloskar) (iii) FRP cooling tower including lubrication and servicing of mechanical transmission and repair and pluging of leakages with FRP patches to bottom tank of cooling tower complete with electric motor of capacity 7.5 KW, 1460 RPM, 415Volt -02 Sets (Tower model: 9081 of make- Mihir, Electric motor of make- Navyug) (iv) Condensor water pipe line of size 300mm dia to 450mm dia complete with butterfly valve 50mm to 200mm dia of make: Kirloskar, strainer including cost of repair/ replacement of chiller/ hot water pipe less than 100mm dia and accessories complete all as per requirement. (v) AHU complete with accessories i.e. blower with casing, chilled water coil, hotwater coil, filter, filter frame drive motor, humidification kit, mortise motor control panel including lubrication and servicing of mechanical transmission etc as required. Note:- Spares shall be measured and paid for separately under relevant item of Sch'A'/ BOQ. (vi) Fan ventilation system with fan motor of capacity 2.2 KW, drive package and vibration pad installed at basement of AHU of MH, Jabalpur. (vii) Makeup/ expansion tank of capacity 5000 Ltrs of PVC of make- Sintex complete with inlet/ outlet GI pipes, PTMT float valves, installed on the roof of the plant room and Hospital bulding - 02 Sets
(viii) Control desk remote to control the AHU panel of 6 Nos AHUs located in different ward/ department in MH Jabalpur complete including replacement of control wiring with and including copper wire of existing type and size of make as approved by GE and replacement of indicating lamp of existing make complete installed at main AC plant room etc Note:- Control wiring, switches and lamps as and when in the opinion of Engr-in-Charge is required to be replaced, same shall be replaced immediately and cost of the same shall be deemed to be included in the unit rates quoted by the contractor. (ix) Mono block pump set of capacity 1.0 HP, 2700 RPM, head 17 to 23 Mtr including suction/ discharge pipe line and electric connection of type KDC 128 pump of make Kirloskar for taking out the inside flow water of the plant room.
(x) LT panel including all accessories and wiring of LT cable for exhaust/ blower control of industrial type installed at main AC plant room including blower fan heavy duty , MS impeller , blower fan and blower shaft with electric motor 10 HP. (xi) Hot water generator of capacity 800 KW with monoblock pump set, AC 415 volts, 50 Hz, 2900 RPM, 10 HP of total head 30 Mtr, 23 LPS with all accessories - 02 Sets (xii) Butterfly motorised valve with actuator gate valves etc. (xiii) Descaling of condenser units (minimum twice during Contract Period). c) Make & model of the any part of the plant which are required to be replaced, shall be the same as per existing one at site or as per OEM . (d) Comprehensive/ periodic maintenance means to ensure the optimum functioning of AC plant by synchronising the entire assembly to produce desired temperature, humidity and duct filteration levels without any extra cost. (e) Periodic maintenance shall take place at every 03 months or as directed by GE.
(f) During entire contract period any defective components and/or any other materials which is not specified/ given in Sch'A'/ BOQ but same is necessary to repair/ replace to make the plant/ machines fully functional, the cost of the same shall be deemed to be included in the unit rates quoted by the contractor and no extra payment shall be made to the contractor on this account. (g) The cost of transportation and other necessary equipment shall be arranged/ brought by the contractor to complete the job and no extra payment shall be made to the contractor on this account. Hence, bidders are advised to visit the site to assess the quantum of work to be carried out in this contract before quoting their rates. (h) Contractor shall appoint the ITI trained operator in the trade of Ref Mechanic/ Electrician or equivalent having minimum 3 years experience in similar trade. (j) Contractor shall provide the log sheets of proforma as approved by Engineer-in-Charge for maintain the records. (k) Contractor shall responsible for maintaining the temperature & humidity to the required level inside the bldg/ shed, failing which a recovery of Rs. 1000.00 per day per plant on account of penalty shall be made from the contractor's dues/ payment .
Comprehensive periodic maintenance, repair & servicing of central Air Conditioning Plant of Make : Blue Star of capacity 3 x 300 TR model: LCW2-320X07X056969 and ventilation system existing at Military Hospital Jabalpur as per manufacturers instructions and as directed by Engr-in-Charge :- Main equipments to be maintained/ serviced are listed below :- (a) Preventive and comprehensive repair, maintenance, servicing through authorised dealer of company for 3 Nos of chilling machine of screw type compressor , 3x 300 TR each single stage, 3000 RPM, 415 Volts, 3 Phase, 50 Hz, shell and tube type condensor with carbon steel plate, copper tube, externally and internally to pass water flow 1400/2000 USG/ PM, including carbon plate shell and tube flooded type chiller unit working with microprocessor based controls in sheet metal control panel etc Make : M/s BLUESTAR. Note:- Refrigerant and compressor oil shall be replaced immediately and cost of the same shall be deemed to be included in the unit rates quoted by the contractor complete all as specified and directed by Engineer-in-Charge.
(b) Other connected parts/accessories :- (i) Condensing pump set with motor of capacity 30 KW/40 HP, 1450 RPM, 50Hz, 03 Sets make : BHARAT BIJALI. (ii) Chiller motor pump set complete of capacity 30 KW/ 25 HP, 1450 RPM, 50Hz, 03 Sets make : BHARAT BIJALI. (iii) FRP cooling tower including lubrication and servicing of mechanical transmission and repair and pluging of leakages with FRP patches to bottom tank of cooling tower complete with electric motor of capacity upto 5.0 HP, 1400/1500 RPM, 415Volt -01 Sets (of suitable tower model required at site). (iv) Condensor water pipe line of size 100mm dia to 400mm dia complete with butterfly valve 50mm to 200mm dia of make: Kirloskar, strainer including cost of repair/ replacement of chiller/ hot water pipe less than 100mm dia and accessories complete all as per requirement at site. (v) AHU complete with accessories i.e. blower with casing, chilled water coil, hotwater coil, filter, filter frame drive motor, humidification kit, mortise motor control panel including lubrication and servicing of mechanical transmission etc as required. Note:- Spares shall be measured and paid for separately under relevant item of Sch'A'/ BOQ.
(vi) Fan ventilation system with of fan motor of capacity upto 5 HP, drive package and vibration pad installed at basement of AHU of MH, Jabalpur. (vii) Makeup/ expansion tank of capacity 5000 Ltrs of PVC of make- Sintex complete with inlet/ outlet GI pipes, PTMT float valves, installed on the roof of the plant room and Hospital bulding - 02 Sets (viii) Control desk remote to control the AHU panel of 6 Nos AHU`s located in different ward/ department in MH Jabalpur complete including replacement of control wiring with and including copper wire of existing type and size of make as approved by GE and replacement of indicating lamp of existing make complete installed at main AC plant room etc Note:- Control wiring, switches and lamps as and when, in the opinion of Engr-in-Charge, is required to be replaced, same shall be replaced immediately and cost of the same shall be deemed to be included in the unit rate quoted by the contractor. (ix) Mono block pump set of capacity 1.0 HP, 2700 RPM, head 17 to 23 Mtr including suction/ discharge pipe line and electric connection of type KDC 128 pump of make Kirloskar for taking out the inside flow water of the plant room.
(x) LT panel including all accessories and wiring of LT cable for exhaust/ blower control of industrial type installed at main AC plant room including blower fan heavy duty , MS impellar , blower fan and blower shaft with electric motor 10 HP. (xi) Hot water generator of capacity 320 KW with monoblock pump set, AC 415 volts, 50 Hz, 2900 RPM, 10 HP of total head 30 Mtr, 23 LPS with all accessories - 02 Sets (xii) Butterfly motorised valve with actuator gate valves etc. (xiii) Descaling of condenser units (minimum twice during Contract Period). (c) Make & model of the any part of the plant which are required to be replaced, shall be the same as per existing one at site or as per OEM. (d) Comprehensive/ periodic maintenance means to ensure the optimum functioning of AC plant by synchronising the entire assembly to produce desired temperature, humidity and duct filteration levels without any extra cost.
(e) Periodic maintenance shall take place at every 03 months or as directed by GE. (f) During entire contract period any defective components and/or any other materials which is not specified/ given in Sch'A'/ BOQ but same is necessary to repair/ replace to make the plant/ machines fully functional, the cost of the same shall be deemed to be included in the unit rates quoted by the contractor and no extra payment shall be made to the contractor on this account. (g) The cost of transportation and other necessary equipment shall be arranged/ brought by the contractor to complete the job and no extra payment shall be made to the contractor on this account. Hence, bidders are advised to visit the site to assees the quantum of work to be carried out in this contract before quoting their rates. (h) Contractor shall appoint the ITI trained operator in the trade of Ref Mechanic/ Electrician or equivalent having minimum 3 years experience in similar trade. (j) Contractor shall provide the log sheets of proforma as approved by Engineer-in-Charge for maintain the records. (k) Contractor shall responsible for maintaining the temperature & humidity to the required level inside the bldg/ shed, failing which a recovery of Rs. 1000.00 per day per plant on account of penalty shall be made from the contractor's dues/ payment .
Comprehensive periodic maintenance, repair & servicing of central Air Conditioning Plant of Make :DAIKIN of capacity 3 x 30 TR Model: UWL030B5-FB ventilation system existing at Military Hospital Jabalpur as per manufacturers instructions and as directed by Engr-in-Charge :- Main equipments to be maintained/ serviced are listed below :- (a) Preventive and comprehensive repair, maintenance, servicing through authorised dealer of company for 3 Nos of chilling machine of suitable type compressor 3 x30 TR , 415 Volts, 3 Phase, 50 Hz,rated cooling /heating capacity 101/135 KW with carbon steel plate, copper tube, externally and internally to pass User side water flow 17.4 m3/Hr, and heat source side water flow 21.7 m3/ Hr including carbon plate shell and tube flooded type chiller unit complete all as specified and directed by engineer in charge. Make : M/s DAIKIN. Note:- Refrigerant and compressor oil shall be replaced immediately and cost of the same shall be deemed to be included in the unit rates quoted by the contractor complete all as specified and directed by Engineer in Charge.
(b) Other connected parts/accessories :- (i) Condensing pump set with motor of capacity 30 KW/40 HP, 1450 RPM, 50Hz, pump head 26.5 Mtr - 02 Sets (Motor of make ALSTOM and Pump of make Kirloskar/as required at site). (ii) Chiller motor pump set complete of capacity 30 KW/ 40 HP, 1450 RPM, 50Hz, total head of pump 26.5 Mtr- 02 Sets (Motor of make : ALSTOM and Pump of make : Kirloskar/as required at site) (iii) FRP cooling tower including lubrication and servicing of mechanical transmission and repair and pluging of leakages with FRP patches to bottom tank of cooling tower complete with electric motor of capacity upto 5.0 HP, 1400/1500 RPM, 415Volt -01 Sets (of suitable tower model required at site). (iv) Condensor water pipe line of size 100mm dia to 400mm dia complete with butterfly valve 50mm to 200mm dia of make: Kirloskar, strainer including cost of repair/ replacement of chillar/ hot water pipe less than 100mm dia and accessories complete all as per required at site. (v) AHU complete with accessories i.e. blower with casing, chilled water coil, hotwater coil, filter, filter frame drive motor, humidification kit, mortise motor control panel including lubrication and servicing of mechanical transmission etc as required. Note:- Spares shall be measured and paid for separately under relevant item of Sch'A'/ BOQ.
(vi) Fan ventilation system with fan motor of capacity upto 5 HP, drive package and vibration pad installed at basement of AHU of MH, Jabalpur. (vii) Makeup/ expansion tank of capacity 5000 Ltrs of PVC of make- Sintex complete with inlet/ outlet GI pipes, PTMT float valves, installed on the roof of the plant room and Hospital bulding - 02 Sets (viii) Control desk remote to control the AHU panel of 6 Nos AHU`s located in different ward/ department in MH Jabalpur complete including replacement of control wiring with and including copper wire of existing type and size of make as approved by GE and replacement of indicating lamp of existing make complete installed at main AC plant room etc Note:- Control wiring, switches and lamps as and when, in the opinion of Engr-in-Charge, is required to be replaced, same shall be replaced immediately and cost of the same shall be deemed to be included in the unit rate quoted by the contractor. (ix) Mono block pump set of capacity 1.5 HP, 200/2700 RPM, head 15 to 23 Mtr including suction/ discharge pipe line of make Kirloskar for taking out the inside flow water of the plant room.
(x) LT panel including all accessories and wiring of LT cable for exhaust/ blower control of industrial type installed at main AC plant room including blower fan heavy duty , MS impeller , blower fan and blower shaft with electric motor upto 10 HP. (xi) Hot water generator of capacity upto 200 KW with monoblock pump set, AC 415 volts, 50 Hz, 2900 RPM, 5 HP of total head upto 30 Mtr, 23 LPS with all accessories - 02 Sets (xii) Butterfly motorised valve with actuator gate valves etc. (xiii) Descaling of condenser units (minimum twice during Contract Period). (c) Make & model of the any part of the plant which are required to be replaced, shall be the same as per existing one at site or as per OEM . (d) Comprehensive/ periodic maintenance means to ensure the optimum functioning of AC plant by synchronising the entire assembly to produce desired temperature, humidity and duct filteration levels without any extra cost.
(e) Periodic maintenance shall take place at every 03 months or as directed by GE. (f) During entire contract period any defective components and/or any other materials which is not specified/ given in Sch'A'/ BOQ but same is necessary to repair/ replace to make the plant/ machines fully functional, the cost of the same shall be deemed to be included in the unit rate quoted by the contractor and no extra payment shall be made to the contractor on this account. (g) The cost of transportation and other necessary equipment shall be arranged/ brought by the contractor to complete the job and no extra payment shall be made to the contractor on this account. Hence, bidders are advised to visit the site to assess the quantum of work to be carried out in this contract before quoting their rates. (h) Contractor shall appoint the ITI trained operator in the trade of Ref Mechanic/ Electrician or equivalent having minimum 3 years experience in similar trade. (j) Contractor shall provide the log sheets of proforma as approved by Engineer-in-Charge for maintaining the records. (k) Contractor shall responsible for maintaining the temperature & humidity to the required level inside the bldg/ shed, failing which a recovery of Rs. 1000.00 per day per plant on account of penalty shall be made from the contractor's dues/ payment .
Attending emergency break down & making functional AC Plant of Make-Carrier of capacity 3x (2x175) TR of model-30 HXC 190 A /AC Plant of Make-Daikin of capacity 3x 30 TR of model-UWL030B5-FB / AC Plant of Make- Blustar of capacity 3x 300 TR of model- LCW2-320X07X056969 ventilation system complete which exist at Military Hospital Jabalpur alongwith equipments as associated as per item No.01 to 03 above. Notes:- (i) The cost of parts/ accessories/ materials if required to be replaced, same shall be paid separately under respective items here-in-after as Supply only as considered/ taken for item No. 01 to 03 above. (ii) Emergency break down shall be attended immediately ON CALL, if emergency break down is not attended immediately on GE's call, a lump sum recovery of Rs. 10000.00 on account of penalty shall be made from the contractor's dues/ payment .
Supply only heating coil of suitable layers, shape and size as per existing one to be fixed under item No. 01 here-in-before complete all as directed. Make:- Voltas or Carrier or Blue Star or Aeco or Universal as approved by GE.
Supply only cooling coil of suitable layers, shape and size as per existing one to be fixed under item No. 01 here-in-before complete all as directed. Make:- Voltas or Carrier or Blue Star or Aeco or Universal as approved by GE.
Supply only heating coil of suitable layers, shape and size as per existing one to be fixed under item No. 02 here-in-before complete all as directed. Make:- Voltas or Carrier or Blue Star or Aeco or Daikin or Universal as approved by GE.
Supply only cooling coil of suitable layers, shape and size as per existing one to be fixed under item No. 02 here-in-before complete all as directed. Make:- Voltas or Carrier or Blue Star or Aeco or Daikin or Universal as approved by GE.
Supply only cassette type line filter made out of 22 gauge MS GI sheet with araldite, non woolen synthetic media having efficiency 95% down to 10 micron as per existing one to be fixed under item No. 01 here-in-before complete all as directed. Make:- Ten Acoty or Athelete or Purolator or Air Tech or Turolaior or Champharm as approved by GE.
Supply only ABSOLUTE (Heppa) filter of size (560 x 560 x 140) mm having rated flow (CMH) = 1700, IPD (mm WG) less than 25 and efficiency more than 99.97 down to 0.3 micron as per existing one to be fixed under item No. 01 here-in-before complete all as directed. Make:- Ten Acoty or Athelete or Purolator or Air Tech or Turolaior or Champharm as approved by GE.
Supply only ABSOLUTE (Heppa) filter of size (610 x 610 x 305) mm having rated flow (CMH) = 1700, IPD (mm WG) less than 25 and efficiency more than 99.97 down to 0.3 micron as per existing one to be fixed under item No. 01 here-in-before complete all as directed. Make:- Ten Acoty or Athelete or Purolator or Air Tech or Turolaior or Champharm as approved by GE.
Supply only PVC fins of size 22 x 10 inch suitable for cooling tower of 350 TR capcity as per existing one to be fixed under item No. 01 /02/03 here-in-before complete all as directed. Make:- Voltas or Carrier or BlueStar or Aeco or Universal as approved by GE.
Supply only power contactor 3 pole, ML-6 type with 2 NO + 2 NC aux contacts, 415 Volt, 50 Hz, rating 160 Amps to be fixed under item No. 01 here-in-before complete all as directed. Make:- Siemens or L&T or EE or GE as approved by GE.
Supply only power contactor 3 pole, ML-5 type with 2 NO + 2 NC aux contacts, 415 Volt, 50 Hz, rating 25 Amps to be fixed under item No. 01 here-in-before complete all as directed. Make:- Siemens or L&T or EE or GE as approved by GE.
Supply only power contactor 3 pole, ML-4 type with 2 NO + 2 NC aux contacts, 415 Volt, 50 Hz, rating 90 Amps to be fixed under item No. 01 here-in-before complete all as directed. Make:- Siemens or L&T or EE or GE as approved by GE.
Supply only power contactor 3 pole, ML-2 type with 2 NO + 2 NC aux contacts, 415 Volt, 50 Hz, rating 32 Amps to be fixed under item No. 01 here-in-before complete all as directed. Make:- Siemens or L&T or EE or GE as approved by GE.
Supply only power contactor 3 pole, ML-1.5 type with 2 NO + 2 NC aux contacts, 415 Volt, 50 Hz, rating 32 Amps to be fixed under item No. 01 here-in-before complete all as directed. Make:- Siemens or L&T or EE or GE as approved by GE.
Supply only power contactor 3 pole, ML-0 type with 2 NO + 2 NC aux contacts, 415 Volt, 50 Hz, rating 12 Amps to be fixed under item No. 01 here-in-before complete all as directed. Make:- Siemens or L&T or EE or GE as approved by GE.
Supply only Electronic timer 0 to 30 Second as per existing one to be fixed under item No. 02 here-in-before complete all as directed. Make:- L&T or EE or GE as approved by GE.
Supply only heating element of capacity 25 KW, 3 phase as per existing to be fixed under item No. 01 here-in-before complete all as directed. Make:- Dass Pass or Rapid Cool as approved by GE.
Supply only bearing of size as per existing suitable for induction motor of capacity 40.0 HP to be fixed under item No. 01 here-in-before complete all as directed. Make:- TATA or SKF or NBC or MNR as approved by GE.
Supply only bearing of size as per existing suitable for induction motor of capacity 25.0 HP to be fixed under item No. 01 here-in-before complete all as directed. Make:- TATA or SKF or NBC or MNR as approved by GE.
Supply only bearing of size as per existing one suitable for induction motor of capacity 10.0 HP to be fixed under item No. 01 here-in-before complete all as directed. Make:- TATA or SKF or NBC or MNR as approved by GE.
Supply only bearing of size as per existing one suitable for induction motor of capacity 7.50 HP to be fixed under item No. 01 here-in-before complete all as directed. Make:- TATA or SKF or NBC or MNR as approved by GE.
Supply only bearing of size as per existing one suitable for induction motor of capacity 5.0 HP to be fixed under item No. 01 here-in-before complete all as directed. Make:- TATA or SKF or NBC or MNR as approved by GE.
Supply only MCCB 4 pole with enclosure, 415 volts, 50 Hz, 400 Amps with breaking capacity 35 kA to be fixed under item No. 01 here-in-before complete all as directed. Make:- Havells or L&T or C&S as approved by GE.
Supply only MCCB 4 pole with enclosure, 415 volts, 50 Hz, 100 Amps with breaking capacity 25 kA to be fixed under item No. 01 here-in-before complete all as directed. Make:- Havells or L&T or C&S as approved by GE.
Supply only MCCB 4 pole with enclosure, 415 volts, 50 Hz, 63 Amps with breaking capacity 10 kA to be fixed under item No. 01 here-in-before complete all as directed. Make:- Havells or L&T or C&S as approved by GE.
Supply only power indication lamps with complete accessories 230 volts, single phase as per existing duly approved by Engr-in-Charge to be fixed under item No. 01,02&03 here-in-before complete all as directed.
Supply only over load relay range 9 to 15 Amps, MN-2 type to be fixed under item No. 01 here-in-before complete all as directed. Make:- Havells or L&T or CG as approved by GE.
Supply only over load relay range 3 to 5 Amps, MN-2 type to be fixed under item No. 01 here-in-before complete all as directed. Make:- Havells or L&T or CG as approved by GE.
Supply only negative sequence voltage sensing phase failure relay, single phase preventor VSPDL 230 volts 50 Hz, AC to be fixed under item No. 01 here-in-before complete all as directed. Make:- L&T or Minilac as approved by GE.
Supply only butter fly valve with side handle operated type of 65 mm dia to be fixed under item No. 01 here-in-before complete all as directed. Make:- Kirloskar or Unique or Castle as approved by GE.
Supply only butter fly valve with side handle operated type of 80 mm dia to be fixed under item No. 01 here-in-before complete all as directed. Make:- Kirloskar or Unique or Castle as approved by GE.
Supply only butter fly valve with side handle operated type of 125 mm dia to be fixed under item No. 01 here-in-before complete all as directed. Make:- Kirloskar or Unique or Castle as approved by GE.
Supply only butter fly valve with side handle operated type of 150 mm dia to be fixed under item No. 01 here-in-before complete all as directed. Make:- Kirloskar or Unique or Castle as approved by GE.
Supply only temperature gauge (digital type) bottom connected, direct mounting type, range 0 to 100° C or 32 to 212°F complete as per existing make duly approved by GE to be fixed under item No. 01 here-in-before complete all as directed.
Supply only V belt 'B' section of size B-60 as per existing one to be fixed under item No. 01 here-in-before complete all as directed. Make:- Fenner or Dunlop as approved by GE.
Supply only V belt 'B' section of size SPA-1532 as per existing one to be fixed under item No. 01 here-in-before complete all as directed. Make:- Fenner or Dunlop as approved by GE.
Supply only V belt 'B' section of size A-56 as per existing one to be fixed under item No. 01 here-in-before complete all as directed. Make:- Fenner or Dunlop as approved by GE.
Supply only V belt 'B' section of size A-47 as per existing one to be fixed under item No. 01 here-in-before complete all as directed. Make:- Fenner or Dunlop as approved by GE.
Supply only water flow switch of type RC-61 MWP 150 PSI electric rating 250 volts, 50Hz, 15 Amps with senser and lead as per existing make duly approved by GE to be fixed under item No. 01 here-in-before including testing and commissioning complete all as directed.
Supply only pressure gauge round type of 10cm dia metal cased between pressure range 0 to 10 kg/cm2 including syphon assembly with stop/ ON knob as per existing make duly approved by GE to be fixed under item No. 01 here-in-before complete all as directed.
M&L for dismantling & taking out the old unserviceable/ burnt winding wire after taking out the 3 phase, 50 Hz, 415 volts electric motor of capacity 1.0 HP from existing position and rewinding the same with superior quality copper winding wire of suitable gauze and number of turns including insulating materials (PVC insulation sleeve, tape, film paper, varnish, cotton & heating process etc) as required including replacement of existing DE & ND side bearings and re-fixing the motor in existing position after re-assembling and testing on completion complete all as specified & directed.
M&L for dismantling & taking out the old unserviceable/ burnt winding wire after taking out the 3 phase, 50 Hz, 415 volts electric motor of capacity 1.50 HP from existing position and rewinding the same with superior quality copper winding wire of suitable gauze and number of turns including insulating materials (PVC insulation sleeve, tape, film paper, varnish, cotton & heating process etc) as required including replacement of existing DE & ND side bearings and re-fixing the motor in existing position after re-assembling and testing on completion complete all as specified & directed.
M&L for dismantling & taking out the old unserviceable/ burnt winding wire after taking out the 3 phase, 50 Hz, 415 volts electric motor of capacity 2.0 HP from existing position and rewinding the same with superior quality copper winding wire of suitable gauze and number of turns including insulating materials (PVC insulation sleeve, tape, film paper, varnish, cotton & heating process etc) as required including replacement of existing DE & ND side bearings and re-fixing the motor in existing position after re-assembling and testing on completion complete all as specified & directed.
M&L for dismantling & taking out the old unserviceable/ burnt winding wire after taking out the 3 phase, 50 Hz, 415 volts electric motor of capacity 3.0 HP from existing position and rewinding the same with superior quality copper winding wire of suitable gauze and number of turns including insulating materials (PVC insulation sleeve, tape, film paper, varnish, cotton & heating process etc) as required including replacement of existing DE & ND side bearings and re-fixing the motor in existing position after re-assembling and testing on completion complete all as specified & directed.
M&L for dismantling & taking out the old unserviceable/ burnt winding wire after taking out the 3 phase, 50 Hz, 415 volts electric motor of capacity 5.0 HP from existing position and rewinding the same with superior quality copper winding wire of suitable gauze and number of turns including insulating materials (PVC insulation sleeve, tape, film paper, varnish, cotton & heating process etc) as required including replacement of existing DE & ND side bearings and re-fixing the motor in existing position after re-assembling and testing on completion complete all as specified & directed.
M&L for dismantling & taking out the old unserviceable/ burnt winding wire after taking out the 3 phase, 50 Hz, 415 volts electric motor of capacity 7.50 HP from existing position and rewinding the same with superior quality copper winding wire of suitable gauze and number of turns including insulating materials (PVC insulation sleeve, tape, film paper, varnish, cotton & heating process etc) as required including replacement of existing DE & ND side bearings and re-fixing the motor in existing position after re-assembling and testing on completion complete all as specified & directed.
M&L for dismantling & taking out the old unserviceable/ burnt winding wire after taking out the 3 phase, 50 Hz, 415 volts electric motor of capacity 10.0 HP from existing position and rewinding the same with superior quality copper winding wire of suitable gauze and number of turns including insulating materials (PVC insulation sleeve, tape, film paper, varnish, cotton & heating process etc) as required including replacement of existing DE & ND side bearings and re-fixing the motor in existing position after re-assembling and testing on completion complete all as specified & directed.
M&L for dismantling & taking out the old unserviceable/ burnt winding wire after taking out the 3 phase, 50 Hz, 415 volts electric motor of capacity 25.0 HP from existing position and rewinding the same with superior quality copper winding wire of suitable gauze and number of turns including insulating materials (PVC insulation sleeve, tape, film paper, varnish, cotton & heating process etc) as required including replacement of existing DE & ND side bearings and re-fixing the motor in existing position after re-assembling and testing on completion complete all as specified & directed.
M&L for dismantling & taking out the old unserviceable/ burnt winding wire after taking out the 3 phase, 50 Hz, 415 volts electric motor of capacity 40.0 HP from existing position and rewinding the same with superior quality copper winding wire of suitable gauze and number of turns including insulating materials (PVC insulation sleeve, tape, film paper, varnish, cotton & heating process etc) as required including replacement of existing DE & ND side bearings and re-fixing the motor in existing position after re-assembling and testing on completion complete all as specified & directed.
M&L for dismantling blower shaft of AHU up to 80 TR by removing the belt & pully, blower drum and remetaling the shaft with welding, turning & grinding to obtain its original dimensions, balancing the shaft and refitting in AHU including reassembling the blower, pulley, bearing etc. and testing the AHU on completion for satisfactory operation complete all as specified & directed.
M&L for repair/ overhaulling of hot water generator of capacity 250 KW out put by unscrewing and draining out to detect leakages, welding where-ever necessary, removing burnt/ unserviceable heating element from bottom level of tank, scraping out rust/ sludge including putting new insulation sleeves to bare conductors, fixing of 4 Nos new/ fresh heating elements of suitable capacity, replacement of PCC kit with new one and reassembling all the dismantled components and testing on completion for satisfactory operation complete all as specified & directed.
M&L for complete repair/ over-hauling to FRP based cooling tower of 350 TR capacity by dismantlinlg fins, couplings, cooling fan, draining out of water moving algey deposited and cleaning, servicing of mechanical components, welding wherever necessary, scraping out rust/ sludge including putting descaling solution and replacing of gear box, bearings, gear oil, mechanical couplings as per site requirement and over-hauling the complete transmission system of cooling tower and painting the complete system as per existing one duly approved by GE and reassembling all the dismantled components and testing on completion for satisfactory operation complete all as specified & directed.
Supply and fixing of presure gauge of size 4" dia, 30 to 150 Pa as per existing make duly approved by GE complete all as specified & directed.
Supply and fixing of new temperature sensor with sensor cable of central Air Conditioning Plant of Make : Carrier of capacity 3 x (2 x 175) TR model:30 HXC 190 A exist at Military Hospital Jabalpur as per existing make/ as per manufacturer's recommendations duly approved by GE after taking out the old unserviceable temperature sensor with sensor cable complete all as specified & directed.
Supply and fixing of new transducer of central Air Conditioning Plant of Make : Carrier of capacity 3 x (2 x 175) TR model:30 HXC 190 A exist at Military Hospital Jabalpur as per existing make/ as per manufacturer's recommendations duly approved by GE after taking out the old unserviceable transducer complete all as specified & directed.
Supply and fixing of new transducer of central Air Conditioning Plant of Make : Daikin of capacity 3 x 30 TR model: UWL030B5-FB exist at Military Hospital Jabalpur as per existing make/ as per manufacturer's recommendations duly approved by GE after taking out the old unserviceable transducer complete all as specified & directed.
Supply and fixing/ installation of 5.4mm thick MS pipe line heavy grade as per IS-3589 (Part-I) -2004 of size 150mm bore suitable for hot/ cold water for central air conditioning plant including necessary grouting, clipping on wall surface and all machine works i.e. cutting threding, welding, jointing etc as required including all necessary fittings i.e. elbows, tees, sockets, union, flange, coupling etc and leakage testing on completion at desired pressure and commissioning complete all as specified & directed. Make:- Tata Steel or Jindal or Electrosteel as approved by GE.
Supply and fixing/ installation of 4.85mm thick MS pipe line heavy grade as per IS-3589 (Part-I) -2004 of size 80mm bore suitable for hot/ cold water for central air conditioning plant including necessary grouting, clipping on wall surface and all machine works i.e. cutting threding, welding, jointing etc as required including all necessary fittings i.e. elbows, tees, sockets, union, flange, coupling etc and leakage testing on completion at desired pressure and commissioning complete all as specified & directed. Make:- Tata Steel or Jindal or Electrosteel as approved by GE.
Taking out compressor of Air Conditioning Plant of Make : Carrier of capacity 175 TR model : 30 HXC 190 A from its existing position i.e. from MH Jabalpur for transporting the same to the Carrier Service Centre DELHI after storing of refrigerant gas into empty refrigerant cylinder, opening & dismantling of all electrical connections and refrigerant piping and removing & loading of compressor chiller in to the truck with the help of chain pullies & skilled labours for complete overhauling and replacement of following parts/ items & servicing after dismantling & opening of compressor and checking of all electrical and mechanical components at workshop of Carrier Service Centre and re-assembling & transporting back the same from Carrier Service Centre DELHI to its existing location after making the compressor fully fuctional including loading of compressor chiller in to the truck with the help of chain pulley & skilled labours and installation of compressor at its existing position with the help of chain pulley & skilled labours, making all electrical & refrigerant piping connctions, re-filling of stored refrigerant gas in to the compressor and tightening of all connection nuts, bolts, screws & gasket etc and testing on completion at desired pressure upto 24 hours and commissioning complete all as specified & directed :- (a) Cleaning of housing, screw, piston and rewinding of stator complete as per Manuacturer's recommendations. (b) Replacement of both sides bearings, O-ring complete as per Manuacturer's recommendations. (c) Replacement of loading unloading mechanical arrangement and replacement of suction discharge rids complete as per manuacturer's recommendations. (d) Measurement of all clearance after refitting of compressor complete as per manuacturer's recommendations. (e) Charging of Nitrogen upto the desired pressure as directed and to withstand the pressure up to 24 hours for detecting the leakage and repairing of leakage if any found and re-testing the same with again charging of Nitrogen upto the desired pressure as directed and to withstand the pressure upto 24 hours for testing of leakage complete.
S&F Discharge Senser suitable for compressor 175TR capacity of model : 30HXC 190A carrier complete all as specified and directed.
supply only compressor oil synthetic suitable for compressor 175TR capacity of model : 30HXC 190A carrier complete all as specified and directed.
S&F H.P. Switch suitable for compressor 175TR capacity of model : 30HXC 190A carrier complete all as specified and directed.
S&F oil solenoid valve suitable for compressor 175TR capacity of model : 30HXC 190A carrier complete all as specified and directed.
loading and unloading of solenoid valve suitable for compressor 175TR capacity of model : 30HXC 190A carrier complete all as specified and directed.
S&F internal oil filter suitable for compressor 175TR capacity of model : 30HXC 190A carrier complete all as specified and directed.
S&F external oil filter suitable for compressor 175TR capacity of model : 30HXC 190A carrier complete all as specified and directed.
S&F dryer core suitable for compressor 175TR capacity of model : 30HXC 190A carrier complete all as specified and directed.
Supply & fix/ installation of new display board (mother board) as per existing one duly approved by GE suitable for Air Conditioning Plant of Make : Carrier of capacity 3 x (2 x 175) TR model : 30 HXC 190 A having all parameters to start/ stop of chiller, checking facilities of running hours of chiller and all key functions of Air Condtitioning plant etc after taking out old unserviceable display board and testing on completion for satisfactory operation complete all as specified & directed.
M&L for cleaning/ preparation of complete surfaces of cooling tower & all pipe lines of condenssor/ chiller of Air Conditioning Plant of Make : Carrier of capacity 3 x (2 x 175) TR model : 30 HXC 190 A for painting after complete removal of existing paint and applying two coats of synthetic enamel paint of shade as approved by GE over and incluading a coat of red oxide primer complete all as specified and directed.
M&L for cleaning/ prepration of complete surfaces of cooling tower & all pipe lines of condenssor/ chiller of Air Conditioning Plant of Make : Daikin of capacity 3 x 30 TR model : UWL030B5-FB for painting after complete removal of existing paint and applying two coats of synthetic enamel paint of shade as approved by GE over and incluading a coat of red oxide primer complete all as specified and directed.
Supply & fix/ installation of new discharge NRV as per existing duly approved by GE suitable for Air Conditioning Plant of Make : Carrier of capacity 3 x (2 x 175) TR model : 30 HXC 190 A after shut down the air conditioning unit & opening of compressor and taking out of old unserviceable discharge NRV and leakage testing on completion at desired pressure and commissioning complete all as specified & directed.
M&L for repairing of chiller evaporator tube leakages after find out the number of tube leakages with charging of Nitrogen upto the desired pressure as directed and stop/ sealed tube leakage with and icluding dead nuts or tube expender and to withstand the Nitrogen pressure upto 24 hours for detecting the leakage and repairing of leakage, if any, found and re-testing the same with again charging of Nitrogen upto the desired pressure as directed and to withstand the pressure upto 24 hours including removing/ flushing water from refrigement system with the help of a grad nitrogen and making vacuum and dehydration of system as per job replacement and testing on completion at desired pressure and commissioning complete all as specified & directed.
Supply & fix/ installation of new SCPM Card as per existing one duly approved by GE suitable for Air Conditioning Plant of Make : Carrier of capacity 3 x (2 x 175) TR model : 30 HXC 190 A having configuration such as start the compressor through SCPM Card and checking of all key functions set & safety of compressor, oil level safety, high pressure safety, motor current safety and all other fault of Air Condtitioning plant etc after dismantaling of old unserviceable SCPM card from machine and testing on completion for satisfactory operation complete all as specified & directed.
M&L for mild steel work Fe-410-W (Gde-E-250) quality-A as in duct cover in repairs with mild steel chequered plates or any other sections of any thickness as required at site including lifting handle/ arrangement as required etc including all necessary welding and applying two coat of black bituminous paint over and including a coat of red-oxide primer after preparation of surfaces complete all as specified and directed.
Schedule of credit amount of Rs. 71,763.00 be deducted during AOC
kiran electrical and hardware centre
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .