Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹29.0 L+₹3.1 L (12.0%)Rejected-Finance 302 SIDDHIVINAYAK APPT A WING MUMBAI K K MARG JACOB CIRCLE MUMBAI CITY MAHARASHTRA 400 011 | MUMBAI | MAHARASHTRA | 400011 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹32.0 L+₹6.1 L (23.7%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹32.5 L+₹6.6 L (25.6%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹35.5 L+₹9.6 L (37.0%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
30 Jun 2021, 6:00 pmClosed
GE NW NOFRA
GE NW NOFRA DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR REPLACEMENT AND MAINTENANCE OF EM FITTING FIXTURES INCLUDING DBs MAIN SWITCHES SUB MAIN SERVICE CONNECTION EARTHING AND DAY TO DAY MAINT OF GEYSER AT NOFRA AREA UNDER GE NW NOFRA COLABA MUMBAI
2021_MES_448645_1
8913
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Mumbai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NW NOFRA
₹80,000
Yes
24 Jul 2021
4 Jun 2021
5 Jul 2021
4 Jun 2021
30 Jun 2021
18 Jun 2021
4 Jun 2021 - 17 Jun 2021
Amount
Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces complete all as specified and directed by Engineer in charge.
Supply and fix in repair submain wiring two single core FRLS 6 Sqmm for sub main witing with copper conductor multistranded PVC insulated and unsheathed 1100Volts grade in and including PVC conduit not less than 25mm dia with fixing accessories including one run of 6.0 Sqmm copper conductor complete all as specified and directed by Engineer in charge. Note :- (i) Two runs of 06 Sqmm cable, one run of 6.0 Sqmm earth cable and one run of PVC casing Capping /conduit shall be measured as one running meter. (ii) Each submain wiring shall run in seperate PVC casing caping/conduit Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision
Supply and fix submain wiring in repair 2 single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sqmm in and including PVC conduit not less than 25mm dia including 1 single core cable with stranded copper conductor of size 10 sqmm (green colour) for earthing complete all as specified and directed by Engineer in charge. Note :- (i) Two runs of 10 Sqmm cable, 1 run of PVC casing caping/ conduit and 1 run of 10 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping / conduit Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision
Supply and fix in repair sheet metal enclosure 12 way Double door type having protection IP-54, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as specified and directed by Engineer in charge of comprising of the following :- Make - Legrand/ Schneider/ GE
(a) MCB SPN 63 Amps, 240 Volts - 01 No Make - Legrand/ Schneider/ GE
(b) MCB SP 6-32 Amps, 240 Volts. Make - Legrand/ Schneider/ GE
Supply and fix in repair MCB, DB, SPN 8 way double door with protection type IP-54 with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as specified and directed by Engineer in charge., as approved comprising following :- Make - Legrand/ Schneider/ GE
(a) MCB SPN 40 Amps 240 Volts - 01 No. Make - Legrand/ Schneider/ GE
(b) MCB SP 6- 32 Amps 240 Volts - 2 No. Make - Legrand/ Schneider/ GE
Supply and fix in repair single phase sheet metal powder coated double door distribution board 4 way complete all as specified and directed by Engineer in charge comprising with following :- (a) MCB SPN 40Amps 240Volts, 10KA - 1 No. (b) MCB SP 6 - 32Amps 240Volts - 2 No. Make - Legrand/ Schneider/ GE
Supply and fix in repairs sheet metal enclosure 2 way without bus bar with MCB complete all as specified and directed by Engineer in charge comprising following Make - Legrand/ Schneider/ GE
(a) Isolator DP 63 Amps Breaking capacity 10 KA. Make - Legrand/ Schneider/ GE
Supply & fix in repair MCB DB, TPN 8 way vertical type, 415 V with 200 Amps rated bus bar and double door connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as specified and directed by Engineer in charge , comprising of the following : - (a) MCCB 3 Pole, 415 V fixed type, 160 Amps with breaking capacity 25 KA-01 Nos (incoming) MAKE: Legrand, Schneider, GE (b) MCB TP 63 Amps, 10KA - 06 Nos (Outgoing) MAKE: Legrand, Schneider, GE (c) MCB SP 40 Amps, 10KA - 06 Nos (Outgoing) MAKE: Legrand, Schneider, GE
Taking down carefully aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc to be measured separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer in charge.
Material and Labour for point wiring complete with 4 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic casing and caping of size not less than 25mm width, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular boxes surfaced on wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly complete all as specified and directed by Engineer in charge. Make of wire- Polycab/ Finolex/ Havells Make of casing caping- Precision/ Pressfit
Supply and fix in repair Modular Switch, 16Amp, One way, 1 module complete all as specified and directed by Engineer in charge. Make- Legrand (Aretor)/ Goldmedal (Nixon)/ Schneider (Zencelo)
Supply and fix in repair Modular Socket oulet, 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and directed by Engineer in charge. Make- Legrand (Aretor)/ Goldmedal (Nixon)/ Schneider (Zencelo)
Supply and fix in repair Modular white cover plate with Frame 3 Module complete all as specified and directed by Engineer in charge. Make- Legrand (Aretor)/ Goldmedal (WEGA)/ Schneider (Zencelo)
Supply and fix in repair Modular PVC flush box 3 module complete all as specified and directed by Engineer in charge. Make- Legrand (Aretor)/ Goldmedal (WEGA)/ Schneider (Zencelo)
S&F in repair switch socket combination multipurpose 2 in 1 for 3 pin 15 Amps & 3pin 5 Amp controlled by one switch flush type complete all as specified and directed by Engineer in charge. Make- Anchor / Legrand/ Goldmedal
Supply and fix in repair heating element 2KW /3KW, of instant type water heater as per existing capacity at site complete all as specified and directed by Engineer in charge.
Supply and fix in repair heating element 1KW, of storage type water heater 25 Ltr capacity at site complete all as specified and directed by Engineer in charge.
Supply and fix in repair heating element 1.5 KW, of storage type water heater 50 Ltr capacity at site complete all as specified and directed by Engineer in charge.
Supply and fix in repair thermostat / thermal cut out suitable for storage type water heater 25/50 Ltr capacity complete all as specified and directed by Engineer in charge.
Supply and fix in repair thermostat / thermal cut out suitable for instant type water heater 01 /06 Ltr capacity complete all as specified and directed by Engineer in charge.
Supply and fix in repair hot water extension pipe made out of copper chromium plated 450mm long with brass adaptor and fixing in position complete all as specified and directed by Engineer in charge.
Supply and fix in repair 450mm long PVC connector with brass adaptor, washer and fixing in position complete all as specified and directed by Engineer in charge.
Taking down and Supply & fix PVC cable multistranded insulated copper conductor 1100 volts grade of 4 sqmm 3 core, ISI markedcomplete all as specified and directed by Engineer in charge. Make- Polycab/ Havells/ finolex
Material and Labour for replacement of Inner tank made of SS 304 suitable for electric water heater capacity 25 Ltrs including PUF insulation for trap the heat in inner tank, high pressure withstanding enabling to use in high rise building complete all as specified and directed by Engineer in charge.
Material and Labour for replacement of Outer body made of CRCA, colour- Ivory/white suitable for electric water heater capacity 25 Ltrs for multiple safety for dry heating & overheating complete all as specified and directed by Engineer in charge.
Material and Labour for replacement of Inner tank made of SS 304 suitable for electric water heater capacity 06 Ltrs including PUF insulation for trap the heat in inner tank, high pressure withstanding enabling to use in high rise building complete all as specified and directed by Engineer in charge.
Material and Labour for replacement of Outer body made of CRCA, colour- Ivory/white suitable for electric water heater capacity 06 Ltrs for multiple safety for dry heating & overheating complete all as specified and directed by Engineer in charge.
Material and Labour for replacement of Inner tank made of SS 304 suitable for electric water heater capacity 01 Ltrs including PUF insulation for trap the heat in inner tank, high pressure withstanding enabling to use in high rise building complete all as specified and directed by Engineer in charge.
Material and Labour for replacement of Outer body made of CRCA, colour- Ivory/white suitable for electric water heater capacity 01 Ltrs for multiple safety for dry heating & overheating complete all as specified and directed by Engineer in charge.
Supply and fix RCCB with MCB of 2 pole, 25 Amp rating,IP 20 with sensitivity of 30 mA suitable for 240Volts including metal box 2P, IK 08 complete all as specified and directed by Engr-in-Charge. Make- Legrand/ ABB/ Schneider
Supply and fix in repair 15 Amps plug top, AC 230 volts, ISI marked complete all as specified and directed by Engineer in charge. Make- Anchor/ Havells/ Legrand
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or burried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6 mm galvanised iron strip complete all as specified and directed by Engineer in charge.
Earthing with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, burried directely in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip32 x 6 mm with the help of bolts, nuts, and washers of galvanised iron or steel, including necessary excavation, PCC 1:3:6 type C2 and PCC cover 1:2:4 type B1 watering arrangement with GI pipe funnel, jali, complete all as specified and shown in electrical plate No. 5 of SSR Pt-1, including testing on completion complete all as specified and directed by Engineer in charge.
the bhimani group of companies
M/S V N ENTERPRISES
DHARMESH ENTERPRISES
shubham construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .