| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.5 L+₹1.0 L (4.74%)Rejected-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹23.7 L+₹2.2 L (10.2%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹25.6 L+₹4.1 L (18.8%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹26.0 L+₹4.5 L (21.0%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
23 Jan 2021, 6:00 pmClosed
GE UTILITIES
GE UTILITIES UDHAMPUR PO-GARHI PIN -182121
Repair/Maintenance of LT panel with replacement of control switches, meters, service connections, LT UG cables, Lt overhead line and allied works at JNE area under GE Utilities Udhampur
2020_MES_407605_2
GE/U-72/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
GE Utilities Udhampur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹60,000
Yes
22 Feb 2021
9 Jan 2021
25 Jan 2021
9 Jan 2021
23 Jan 2021
11 Jan 2021
Amount
M & L in repair LT end termination kit, heat shrinkable outdoor type suitable for XLPE, armoured cables taking down the cable form over head line for making joint and reconnecting to overhead lines for cable of size 3.5 Core 25 Sqmm to 50 Sqmm complete all as specified and as directed. Make:- Raychem/ Denson/ M-Seal
All as per serial item No: 1.00 here-in- before but LT cable size of 70Sqmm to 150 Sqmm x 3.5 Core
M & L in repair for LT heat shrinkable straight through joint for PVC/XLPE insulated armoured cable of size upto 50 Sqmm complete all as specified and as directed. Make:- Raychem/Denson/M-Seal
All as per serial item No: 3.00 here-in- before but for LT cable size of 70 Sqmm to 150 Sqmm x 3.5 Core
All as per serial item No: 3.00 here-in- before but for LT cable size of 185 Sqmm to 240 Sqmm x 3.5 Core
Repair of incomming and outgoing cables of LT Panel/feeder pillar box/DB, 415 Volt, drassing, crimping, replacement of gland, lugs, terminal nuts and bolts, etc. complete all as required at site. NOTE : Excavation, returning filling, bricks, sand and spares ie. gland, lugs, terminal nuts and bolts, etc to be measured and paid separately.
Dismantling of MCCBs/Change over switches of any capacities complete all as specified and directed.
Dismantling of bus bar chamber of any description complete all as specified and directed.
M & L for replacement of burnt out aluminium lugs of sizes 400 Sqmm (03 Nos) and 300 Sqmm (01 Nos) complete after taking down old unsrviceable one and after cutting and sealing the cable required at site as directed by Engr-in-Charge.
Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed.
Material and labour for Dry sand cushioning to underground cables provided with a layer of sand 8 cm thick before laying the cable and 15 cm thick after laying and stretching the cable, sand cushion shall be punned to 18 cm thickness complete all as specefied and directed by Engr-in-charge. Note : Only punned thickness shall be measured and paid.
Supply and fixing burnt brick sub class B for cable protection laid adjacent to each other perpendicular to the direction of cable in trenches complete all as specified and directed.
Supply and Laying Galvanised iron steel tubes, ISI marked light grade of size 40 mm bore for cable protection along the poles under road under drains, laid in trenches/fixed on walls/poles with suitable clamps bolts nuts etc complete all as specified and directed by Engineer-in-Charge.
Supply and Laying Galvanised iron steel tubes, ISI marked light grade of size 80 mm bore for cable protection along the poles under road under drains, laid in trenches/fixed on walls/poles with suitable clamps bolts nuts etc complete all as specified and directed by Engineer-in-Charge.
Taking down the unserviceable LT cable of any size from trenches/ walls /floor etc complete all as specified and as directed by engineer in charge .
Supply, laying, jointing & testing in replacement XLPE insulated, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 2 core laind in trenches or passing through pipe or fixed on poles complete all as specefied and directed by Engr-in-Charge.
All as per serial item No: 18.00 here-in- before but of size 16 Sqmm 4 core.
All as per serial item No: 18.00 here-in- before but of size 25 Sqmm 3.5 core.
All as per serial item No: 18.00 here-in- before but of size 35 Sqmm 3.5 core.
All as per serial item No: 18.00 here-in- before but of size 50 Sqmm 3.5 core.
All as per serial item No: 18.00 here-in- before but of size 70 Sqmm 3.5 core.
All as per serial item No: 18.00 here-in- before but of size 95 Sqmm 3.5 core.
All as per serial item No: 18.00 here-in- before but of size 120 Sqmm 3.5 core.
All as per serial item No: 18.00 here-in- before but of size 150 Sqmm 3.5 core.
S & F in replacement MCCB four pole 63 Amps, 50 Hz with breaking capacity 16KA, Ics = 100% Icu , 415 Volts, Adjustable thermal & Fixed magnetic setting including making all incoming/ outgoing connections complete all as specified and directed by Engineer in Charge.
All as per item Sr. No: 33 but 250 Amps with breaking capacity 25 KA.
Supply and fix busbar chamber 250 amps rating, 8 way complete all as specefied and directed by Engr-in-charge. Havells Cat No cat no IHBC025008 of Make:- Havells Cat No IHBC025008 or equivalent in Lagrand /ABB
Supply and fix Modular box of size 280x170x130mm made of FRP inpact resistance plastic & heat resistant materials including MCB SP 6 A, Connector terminal block 4 pole 16 A capacity and fixing to the street light or post top light pole with suitable sizes of clamps, nuts and bolts complete all as specefied and directed by Engr-in-charge.
Supply, Laying, jointing & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 4 Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc complete all as specefied and directed by Engr-in-charge.
M & L PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation for poles, filling of mass concrete complete all as specified and as directed
M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping for old and new poles including form work complete all as specified and as directed by Engineer-in-Charge.
Supply, Installation , testing and commissioing in replacement of outdoor type, weather proof, cubicle panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40x40x6 mm equal angle, embedded in PCC 1:2:4 type B-1 blocks of size 15x15x15 cm front and back openable, double door openable up to minimum 150 degree & removable type having magnetic catche system, lockable/openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable foamed in PU gasket to make it dust/vermin proof, IP 54 protection, powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliset for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produced to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete suitable cable glands for cable entry. The panel shall accomodate the following equipments:-
Aluminium Bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 800 Amps for phases and neutral - 01 set
Panel indicating lamp neon/LED type (Red, Yellow & Blue) with lamp holders - 03 Nos
Panel instrumental wiring with FRLS suitable size but not less than 2.5 Sqmm copper wire single core - 01 Job
INCOMING (a) MCCB 4 Pole, Ics = 100% Icu, 50 KA, 415 Volts, 500 Amps, with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos
OUT GOING (a) MCCB 4 Pole, Ics = 100% Icu, 35/36 KA, 415 Volts, 250 Amps, with thermal adjustable and fixed magnetic setting with extended terminals - 02 Nos (b) MCCB 4 Pole, Ics = 100% Icu,25/26KA, 415 Volts, 200 Amps, with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos (c) MCCB 4 Pole, Ics = 100% Icu,25/26KA, 415 Volts, 100 Amps, with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos
Supply, Installation , testing and commissioing in replacement outdoor type, weather proof, cubicle panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40x40x6 mm equal angle, embedded in PCC 1:2:4 type B-1 blocks of size 15x15x15 cm front and back openable, double door openable up to minimum 150 degree & removable type having magnetic catche system, lockable/openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable foamed in PU gasket to make it dust/vermin proof, IP 54 protection, powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliset for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produced to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete suitable cable glands for cable entry. The panel shall accomodate the following equipments:-
Aluminium Bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 800 Amps for phases and neutral - 01 set
Panel indicating lamp neon/LED type (Red, Yellow & Blue) with lamp holders - 03 Nos
Panel instrumental wiring with FRLS suitable size but not less than 2.5 Sqmm copper wire single core - 01 Job
INCOMING (a) MCCB 4 Pole, Ics = 100% Icu, 35/36 KA, 415 Volts, 400 Amps, with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos
OUT GOING (a) MCCB 4 Pole, Ics = 100% Icu,25/26KA, 415 Volts, 200 Amps, with thermal adjustable and fixed magnetic setting with extended terminals - 02 Nos (b) MCCB 4 Pole, Ics = 100% Icu,25/26KA, 415 Volts, 100 Amps, with thermal adjustable and fixed magnetic setting with extended terminals - 02 Nos
Supply, installation and commissioning in replacement LT Feeder pillar box of size 75x75x45 cm outdoor type factory made manufactured by a CPRI approved manufacturer, made out of 3.15 mm thick CRCA sheet and self supporting, built upon Rigid frame work suitable fo 440 volt 3 phase 4 wire system having front and rear hinger doors with neorprene rubber gasket epoxy powder coated with danger plate, earthing strip point and bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etc having colour code aluminium bus bar interconnections for easy identification including incoming/outgoing cable holes at bottom, provision of six nos connectors and embedded with mild steel anglr iron frame of size 50x50x6 mm and 450 mm above normal ground level complete with PCC foundation in cement concrete (1:2:4) type B1 graded stone aggregate and testing after installation including taking down unserviceable Feeder Pillar box with connected acessories after disconnecting all incoming and outgoing cable etc, complete all as specefied and comprising with the following:-
Aluminium Bus-bar 400 Amp, supported with suitable size of Heavy Duty Porcelain Stand Lock with suitable size of Brass Nut, Bolts and Washer with Heat Shrinkable PVC Sleeving. The Bar shall be Colour Coded (Red, Yellow & Blue) for Three Phases and Black for Neutral. – 04 Nos
MCCB 4 Pole, Ics = 100% Icu, 35/36 KA, 415 Volts, 250 Amps, with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos (AS INCOMING)
Material and labour for road cuttig existing road for crossing of underground electric cable for laying of any size GI tubing including necessary excavation and earth work including repairing the same as per existing with pre mix bituminious carpet complete all as specefied and as directed by Engr-in-charge. (Note : Width of trench shall be 15 cm and depth shall be up to 30 cm.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600mm x6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32x6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40 x 40 x 5 mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by the Engineer-in-Charge. Note: On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
Dismantling of old unserviceable/broken/jointed ACSR conductor or earth wire from poles and removing from site of work complete all as specefied and directed by Engr-in-charge
Taking down existing old cross arms of MS channel or angle sections etc all as specified and directed by Engineer-in-Charge.
Taking down burnt and broken out insulators of any size from LT Poles complete all as specefied and directed by Engr-in-charge.
Labour only for re-stretching properly sagged/loose ACSR conductor of any size fixed on LT poles by means of machine method to the permissible limit at different location including tightening of cross arms or D clamps and binding with new binding wire, tightening of jumpers complete all as specified and directed. (Note: 1. Each line of conductor shall be measured. 2. Rate including unwinding of old winding wire and rewind with new binding wire after restretching)
S & F in replacement Shackle type porcelain vitreous white, brown or green insulator of size 75 mm height & 90 mm dia including galvanized mild steel straps of size 31 x 3 mm and bolt of size 12 mm dia, washers and nuts of 75 mm height & 90 mm dia for working pressure 1100 volts grade complete all as specefied and directed by Engr-in-charge.
Supply and fix in replacement Pin type, porcelain, vitreous, white, brown or green insulator 1100 V grade including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Stay assembly complete with acessories as shown in electrical plate no 1 (loop type insulator, stay clamps, stay wire, excavation and concrete measured separately) with 16 mm dia stay rod complete all as specefied and directed by Engr-in-charge including taking down old U/S same items.
S&F in replacement MS Channel/angle iron/flat iron of required size and bend to shape as cross arms, bracing and support including, MS clamps back plates with bolts, nuts, and washers drilled for insulators including painting two coats of synthetic enemel paint (Aluminium shade) over a coat of red oxide primer complete all as specefied and directed by Engr-in-charge.
S & F in replacement Aluminium conductor steel reinforced (ACSR) any size on poles, stretched on LT poles without any kink and bends of various sizes complete including fixing to insulator with Aluminium binding wire complete all as specefied and directed by Engr-in-charge.
M&L for fabrication and fixing of fire point hut, with angle iron roof and supporting frames made out of MS angle iron of 60 x 6 mm size with overall dimensions of roof frame 2000 mm x 1000 mm with MS plain sheet roof of 2 mm thick welded to the frame at required slope as directed and fixed on 2 Nos supporting angle iron posts of 2000 mm high with necessary hooks for fire beaters / buckets, grouted to the foundation including necessary PCC foundation of 1500 mm x 1000 mm x 400 mm complete including applying a coat of synthetic enamel paint of approved colour over a coat of red oxide primer and writing the words "FIRE POINT" by fixing / sticking white coloured fluorescent radium letters of appropriate size as directed on both sides of the roof sheet complete all as specified and as directed.
K S BUILDERS
FANGALIA TRADERS
MOHAN LAL AND SONS
proach associates
shivom builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .