Loading…
Loading…
Tender Value
₹11.6 L
EMD Value
₹23,200
Closing Date
20 Jul 2026, 10:30 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
45 days
Expenditure
Capital (Works)
Above/Below/Par
GENERAL
17 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees. N = Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The balance sheet and all other financial documents attested/certified by CAs to substantiate fulfilment of Financial Eligibility Criteria should be with UDIN, failing which the offer is likely to be rejected without any further reference.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Substantially Completed Work means an ongoing work in which payment equal to or more than 90% of the present contract value (excluding the payment made for adjustment of Price variation (PVC), if any) has been made to the contractor in that ongoing contract and no proceedings of termination of contract on Contractor's default has been initiated. The credential certificate in this regard should have been issued not prior to 60 days of date of invitation of present tender.
Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Defination of Similar Work :- Supply, installation, testing and commissioning of HT panels/LT panels, cable laying, wiring/rewiring of any building/office in Central Government or State Government or Public Sector Undertakings (also called Public Sector Enterprise)
40 conditions · 7 needing a document upload
Mandate form should be uploaded as per attached format in document tab
GST: Tenderer has to fulfills GST Compliance as per Govt. norms
Tenderer may upload GST registration number and certificate.
Security Deposit: As per Indian Railways Standard General Condition of Contract 2022. 16.(1) Security Deposit: The Security Deposit shall be 5% of the contract value. The Bid Security submitted by the Contractor with his tender will be retained/encashed by the Railways as part of security for the due and faithful fulfillment of the contract by the Contractor. Provided further that, if Contractor submits the Cash or Term Deposit Receipt issued from a Scheduled commercial bank of India or irrevocable Bank Guarantee Bond from a Scheduled commercial bank of India, either towards the Full Security Depositor the Part Security Deposit equal to or more than Bid Security, the Railway shall return the Bid Security, to the Contractor. Balance of Security Deposit may be deposited by the Contractor in cash or Term Deposit Receipt issued from Scheduled commercial bank of India or irrevocable Bank Guarantee bond issued from Scheduled commercial bank of India, or may be recovered at the rate of 6% of the bill amount till the full Security Deposit is recovered. Provided also that in case of defaulting Contractor, the Railway may retain any amount due for payment to the Contractor on the pending "on account bills" so that the amounts so retained (including amount guaranteed through Performance Guarantee) may not exceed 10% of the total value of the contract. The Irrevocable Bank Guarantee submitted towards Security deposit shall be initially valid up to the stipulated date of Maintenance period plus 60 days and shall be extended from time to time, depending upon extension of contract granted in terms of Clause 17A and 17B of the Standard General Conditions of Contract. Note: Security Deposit deposited in cash by the Contractor or recovered from the running bills of a Contractor or submitted by contractor as Term Deposit Receipt(s) can be refunded/returned to the contractor, in lieu of irrevocable Bank Guarantee bond issued from scheduled commercial bank of India, to be submitted by him, for an amount equal to or more than the already available Security Deposit, provided however that, in a contract of value less than Rs. 50 Crore, such refund/ return of the already available Security Deposit is permitted up to two times and in a contract of value equal to or more than Rs. 50 Crore, such refund / return of the already available Security Deposit is permitted up to three times
Refund of Security Deposit: Security Deposit mentioned in sub clause (1) above shall be returned to the Contractor along with or after, the following: (a) Final Payment of the Contract as per clause 51.(1) and (b) Execution of Final Supplementary Agreement or Certification by Engineer that Railway has No Claim on Contractor and (c) Maintenance Certificate issued, on expiry of the maintenance period as per clause 50.(1), in case applicable. 16. (2) (ii) Forfeiture of Security Deposit: Whenever the contract is rescinded as a whole under clause 62 (1) of these conditions, the Security Deposit already with railways under the contract shall be forfeited. However, in case the contract is rescinded in part or parts under clause 62 (1) of these conditions, the Security Deposit shall not be forfeited. 16.(3) No interest shall be payable upon the Bid Security and Security Deposit or amounts payable to the Contractor under the Contract, but Government Securities deposited in terms of Sub- Clause 16.(4) (b) of this clause will be payable with interest accrued thereon.
The successful bidder shall submit thePerformance Guarantee (PG) in any ofthe following forms, amounting to 5%of the original contract value andAdditional Performance Guarantee asper Clause 16(4)(h) of GCC-2022, inany of the following forms:- (i) A deposit of Cash; (ii) Irrevocable BankGuarantee; (iii)Government Securitiesincluding State Loan Bonds at 5%below the market value; (iv) PayOrders and Demand Drafts tendered byany Scheduled Commercial Bank ofIndia; (v) Guarantee Bonds executed or Deposits Receipts tendered by any Scheduled Commercial Bank of India;(vi) Deposit in the Post Office Saving Bank; (vii) Deposit in the National Savings Certificates; (viii) Twelve years National Defence Certificates; (ix) Tenyears Defence Deposits; (x) National Defence Bonds and (xi) Unit TrustCertificates at 5% below market valueor at the face value whichever is less.Also, FDR in favour of FA&CAO (freefrom any encumbrance) may beaccepted. New Para 16(4) (h) of Part-IIof GCC'22: If a tender is accepted on the quoted rates of bidder which is below the advertised tender value, an additional performance security shall be submitted by the bidder as below: (i) If Bid quoted in % of advertised costis Below 0 - 5% (inclusive), Additional Performance Guarantee (%) will be'Nil'. (ii) If Bid quoted in % of advertised cost is Below 5%, AdditionalPerformance Guarantee (%) will be'5%.
Performance Guarantee : Thesuccessful bidder shall have to submita Performance Guarantee (PG) within21 (Twenty one) days from the date ofissue of Letter of Acceptance (LOA).Extension of time for submission of PGbeyond 21 (Twenty one) days and upto60 days from the date of issue of LOAmay be given by the Authority who iscompetent to sign the contractagreement. However, a penal interestof 12% per annum shall be charged forthe delay beyond 21(Twenty one) days,i.e. from 22ndday after the date ofissue of LOA. Further, if the 60thdayhappens to be a declared holiday in theconcerned office of the Railway,submission of PG can be accepted onthe next working day. In all othercases, if the Contractor fails to submitthe requisite PG even after 60 daysfrom the date of issue of LOA, thecontract is liable to be terminated. Incase contract is terminated railwayshall be entitled to forfeit Bid Securityand other dues payable to thecontractor against that particularcontract, subject to maximum of Amount. In case a tenderer has not submitted Bid Security on the strength of their registration as a Startup recognized by Department of Industrial Policy and Promotion (DIPP) under Ministry of Commerce and Industry, DIPP shall be informed to this effect. The failed Contractor shall be debarred from participating in re-tender for that work. However the clause may alsoapplicable as amended time to time.
The Performance Guarantee shall be submitted by the successful bidder after the Letter of Acceptance (LOA)has been issued, but before signing of the contract agreement. This P.G. shall be initially valid upto the stipulated date of completion plus 60 days beyond that. In case, the time for completion of work gets extended, the Contractor shall get the validity of P.G.extended to cover such extended time for completion of work plus 60 days
The value of PG to be submitted by the Contractor is based on original contract value and shall not change due to subsequent variation(s) in the original contract value.
The Performance Guarantee (PG) shall be released after physical completion of the work based on 'Completion Certificate' issued by the competent authority stating that the Contractor has completed the work in all respects satisfactorily. The Security Deposit shall, however, be released only after expiry of the maintenance period and after passing the final bill based on No Claim Certificate from the contractor
The value of PG to be submitted by the Contractor is based on original contract value and shall not change due to subsequent variation(s) in the original contract value.
Whenever the contract is rescinded, the Security Deposit shall be forfeited and the Performance Guarantee shallbe encashed. The balance work shallbegot done independently without risk cost of the failed contractor. The failed contractor shall be debarred from participating in the tender for executing the balance work. If the failed contractor is a JV or a Partnershipfirm,then every member/partner of such a firm shall be debarred from participating in the tender for the balance work in his/her individualcapacity or as a partner of any otherJV/partnership firm.
In case of Bank Guarantee submitted as a Performance Guarantee then Bank confirms that it is on the SFMS(Structured Financial Messaging System) and shall invariably send the advice of this Bank Guarantee to the following bank details - IFSC CODE -SBIN000RAIL IFSC TYPE - BRANCHBANK NAME - STATE BANK OF INDIABRANCH NAME - RAIL CITY NAME -NAVI MUMBAI ADDRESS - SECTOR-11,CBD BELAPUR, NAVI MUMBAIDISTRICT - NAVI MUMBAI STATE -MAHARASHTRA BG ENABLED - YES
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Guarantee: The installation will be handed over to the Department after necessary testing and commissioning. The installation will be guaranteed against any defective design/ workman-ship. Similarly, the materials supplied by the contractor will be guaranteed against any manufacturing defect, inferior quality.
Shramikkalyan portal:- (i) Contractor is to abide by the provisions of various labour laws in terms of above clause 54,55, 55-A and 55-B of Indian Railways Standard General Conditions of Contract. In order to ensure the same, an application has been developed and hosted on website 'www.shramikkalyan.indianrailways.gov.in'. Contractor shall register his firm/company etc. and upload requisite details of labour and their payment inthis portal. These details shallbe available in public domain. The registration /updation in Portal shall be done as under: (a)Contractor shall apply for one time registration of his company/firm etc. in the Shramikkalyan portal with requisite details subsequent to issue of Letter of Acceptance. Engineer shall approve the contractor's registration in the portal within 7 days of receipt of such request. (b)Contractor once approved by any Engineer, can create password with login ID (PAN No.) for subsequent use of portal for all Letter of Acceptances (LoAs)issued in his favour. (c)The contractor once registered on the portal, shall provide details of his Letter of Acceptances (LoAs)/ Contract Agreements on shramikkalyan portal within 15 days of issue of any LoA for approval of concerned Engineer. Engineer shall update (if required) and approve the details of LoA filled by contractor within 7 days of receipt of such request. (d)After approval of LoA by Engineer, contractor shall fill the salient details of contract labours engaged in the contract and ensure updating ofeach wage payment to them on shramikkalyan portal on monthly basis. (e)It shall be mandatory upon the contractor to ensure correct and prompt uploading of all salient details of engaged contractual labour & payments made thereof after each wage period. (ii)While processing payment of any'On Account Bill' or 'Final Bill' or release of 'Advances' or 'Performance Guarantee / Security deposit', contractor shall submit a certificate to the Engineer or Engineer's representatives that "I have uploaded the correct details of contract labours engaged in connection with this contract and payments made to them during the wage period in Railway's Shramikkalyan portal at 'www.shramikkalyan.indianrailways.gov.in' till____Month,____Year.
Please read the Explanatory note for detail description of work, their make etc and all other attached documents before submission of Tender.
Any other reputed make/ brand other than as mentioned in the explanatory note may be included during the execution of the works on an urgent basis/as per direction when needed with approval of competent authority.
Electrical work regarding Provision of AT, where IPS is available, at 4 nos. Mid- section LC gate goomties in Kharagpur Division.(SRC jurisdiction)
Elect-Chg-OT-26-27-AT-07~SER
Elect-Chg-OT-26-27-AT-07
Open
Works - General
12 Months
Howrah, West Bengal
₹0
₹23,200
20 Jul 2026
26 Jun 2026
6 Jul 2026
59 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 11,59,260.24 | ||
| — | 20.00 | — | — | ||
| Concealed Wiring of light and fan point by 1.5 sq. mm, Single Core, Multistrand (22/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR- LSH), PVC insulated Cable of 1100V grade, Type-C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked. Earthing the point with 1.5 sq. mm, Single Core, Multistrand (22/0.3mm), Copper Conductor (flexible), Unsheathed, FR-LSH, PVC insulated Cable of 1100V grade, Type-C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked,through PVC Conduit Pipe of Nominal Size 20mm/25mm(as per site requirement) and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark. Modular Electrical Switch, 6 A, 230 V, SP, 1 Way, 1 Module, Unenclosed type as per Clause no.7.1.3, Method of Activation of switch shall be of Rocker type as per Clause no. 7.1.5, Switch shall be Flush type as per Clause no.7.1.6 and shall be installed as per Design A mentioned in the Clause no.7.1.7, Current carrying material as per Clause no. 22.5, with cover made of tough non-ignitable insulating material and bare of tough non-ignitable insulating material or of vitrified ceramic material, Conforming to IS:3854/1997 (reaffirmed 2017) with latest amendments and ISI mark. including supply of all required materials like lamp holder,Aluminium, batten type, with shade carrier ring,ISI marked, Base: B-22 suitable for use at 250V, Conforming to IS: 1258(Rev.-3)-2005)with amdt-3. With BACK plate of 53 MM. Dia & 45 MM PCD.., ceiling rose, Modular type Socket outlet suitable for 3 pin plug, 6A, 230V, 2 Module, Shuttered (Operation of Shutter should be independant of Earthing Point), Cover made of tough Non-Ignitable insulating material, material of base -vitrified ceramic, Conforming to IS : 1293-2019, Amendment no. 1 or latest with ISI mark ,suitable moduler stainless steel JB box with moduler PVC cover , stainless steel switch Board with moduler PVC cover,PVC Spacers, PVC Saddles,PVC Bends, PVC Tees to be provided as and where required as per direction of consignee,. Provision of moduler fan regulator should be kept on switch board . The plate should include 2 blank space for further installation of switches.including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.Covers or cover parts or parts of them, which are intended to ensure protection against electric shock, shall be held in place at two or more points by effective fixings..The cost includes supply of all materials to complete job. ( Two 5-ampere socket point treated as one point). | — | — | — | 17,960 | |
| — | 30.00 | — | — | ||
| Concealed Sub circuit wiring by 2.5 sq. mm, Single Core, Multistrand (36/0.3mm), Copper Conductor(flexible), Unsheathed, Flame Retardant Low Smoke and Halogen (FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS: 694- 2010(reaffirmed 2020), ISI marked. with 2.5Sq mm earthing wire of Single Core, Multistrand (36/0.3mm), Copper Conductor(flexible), Unsheathed, Flame Retardant Low Smoke and Halogen (FR- LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS: 694-2010(reaffirmed 2020), ISI marked. through PVC Conduit Pipe of Nominal Size 25mm and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark with Supply & fixing of PVC Circular Box and Ceiling rose if required with connection from running circuit as per direction of Consignee. including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.The cost includes supply of all materials to complete the job. *Quantity per meter means-one meter conduit with 2 (two) meters Cu. cable of size 2.5 sq mm for phase & neutral and 1mtr of 2.5 Sq.mm PVC Cu. cable as earthing with Supply of PVC Circular Box and Ceiling rose as per direction of Consignee. | — | — | — | 5,477.4 | |
| — | 10.00 | — | — | ||
| Supply of Batten with 20 W LED tube light (with constant current driver having short circuit and overload protection) with Length of LED Batten (Nominal)- 1150 mm (±5%), Operating Voltage range 140-270V, Rated Voltage 220-240 V, Input Frequency- 50Hz, Lamp efficacy 110 lm/Watt, LED chip efficacy 130 lm/Watt, Color temperature- 6500K (Cool White), Housing & Diffuser material made of polycarbonate with Inbuilt Driver having efficiency 85%, Color Rendering Index (CRI) 80, confirming ingress protection level of IP20, SMD based LED chip, Lumen Maintenance should be 80% after 6000 burning Hrs. as per LM 80, Power factor0.9, Surge voltage withstand capacity- 2.5KV, Life of LED should be minimum 50000 Hrs., Warranty for free replacement- 5yrs and 02 nos. of stainless steel mounting clamp and screws for surface mounting of batten with following certification on demand: 1) Availabilty of BIS CRS compliance as per IS 10322(Part 5 sec1 2012: latest. 2) Availability of Photo Biological Safety of LED as per IS:16108 /2012/IEC:62471:2006 3) ISO certification :9001:2015 4) LM79/80 report | — | — | — | 2,449.8 | |
| — | 10.00 | — | — | ||
| Fixing and Commissioning of any kind of Batten with 18W or higher wattage LED tube light with 02 nos. of stainless steel mounting clamp and screws for surface mounting of batten. | — | — | — | 385.2 | |
| — | 4.00 | — | — | ||
| Brushless DC (BLDC) Motor Ceiling Fan, ISI marked, Sweep size: 1200 mm, Minimum Air delivery-210 Cubic Meter/Min, total harmonic distortion- 8% [max], Rated Voltage: 230 V, 50 Hz, Single phase AC, Winding Material- Copper having purity of minimum 99.90 %, Class of Insulation- Class B or higher, Blade thickness (Min): 1.1 mm, Blade material : Aluminium, Bearing : Double ball bearings, Down rod size (without shackle) : 300 mm, Shank & Shackle thickness (Min) : 2 mm, canopy : 2 nos., The PCB shall be installed either inside the motor housing or externally in an enclosure with a degree of protection not less than IP55. If mounted externally, the enclosure shall be fully covered by the canopy. Colour standard: white, BEE rating: 5 star (as per Ministry of Power Notification Number: S.O. 2210 (E) and S.O. 2211 (E) dated. 12th May 2022, S.O. 246(E) dated 17.01.2024, S.O. 3471(E) dated 14.08.2024 or latest), Rated power-28 watt [max], Warranty [Min] 30 Months. Conforming to- (i) IS:374/2019 with Amendment No. 1/2022 or latest (ii)IS:302 (Part 2/Sec 80) - For safety requirement (iii)IS:14700 (Part 3/Sec 2) for THD (iv) IS 191:2007 with amendment no. 2 or latest for Copper purity. Speed control with electronic regulator (step type with minimum 5 running positions) and Regulators shall be provided with radio and television interference suppressing devices as per clause 10.7 of Amendment No. 1/2022 to IS 374/2019 or latest. Cost includes Suitable size of Stainless steel fastener, screw, nuts, bolts, washer, Down rod etc. as per site requirenment. Firm has to supply 5% of Additional Identical PCBs (as used in Ceiling Fans) along with the Ceiling Fans for post warranty repairs. Packing of PCBs should be free from moisture and damages. (i) The Firm shall submit Type test report along with Offer for the offered model & make of the BLDC fan with Electronic Regulator step type with minimum 5 running positions. Test report shall be from the NABL accredited Test lab. (ii) Routine test Certificates has to be submitted along with supply of materials. (iii) Acceptance test shall be carried out by Inspection Agency as per IS 374/2019 with Amendment No. 1/2022 or latest and Acceptance Test Report has to be submitted along with supply of material. (iv)The Firm shall submit Test report along with Offer for the purity of the copper used in the winding of the Offered model & make fan. Test report shall be from the NABL accredited Test lab. (v) Firm shall submit Valid BIS License Certificate for the offered product conforming to IS 374 along with the offer. (vi) Only those BLDC fan models shall be considered which are approved by BIS with speed regulators. (vii) The firm shall submit technical data sheet in the prescribed format. | — | — | — | 12,952 | |
| — | 4.00 | — | — | ||
| Fixing and commissioning of Brushless DC (BLDC) Motor Ceiling Fan, ISI marked, Sweep size: 1200mm / 1400mm, with electronic regulator. Cost includes Suitable size of Stainless steel fastener,clamp, hook, screw,nuts, bolts ,washer,Down rod etc as per site requirenment and connection with flexible twin twisted multistrand Copper wire of 0.75 Sq.mm with flexible pipe and removing of the existing old fan (if any) and handing over of the same to Railway Store with clear acknowledgement, as per site requirement. | — | — | — | 434.28 | |
| — | 2.00 | — | — | ||
| Supply of SPN 6-way DB (Double Door) consisting with DP 20A, 10kA MCB with 2PP, Type B- 01 No. as incoming and SP 10A, 10kA MCB with 1PP, Type B- 04 Nos. as outgoing with bus- bar, Neutral links, Spreader Link and Earth bar etc as applicable. Thickness of DB material (in mm): 1.6 mm (CRCA Sheet Steel). Cost includes all other accessories including stainless steel fastener, Pin Type Terminal End Lugs to complete job as per specification attached | — | — | — | 7,148 | |
| — | 2.00 | — | — | ||
| Fixing and Commissioning of SPN 6-way DB (Double Door) consisting with DP 20A, 10kA MCB with 2PP, Type B- 01 No. as incoming and SP 10A, 10kA MCB with 1PP, Type B- 04 Nos. as outgoing with bus-bar, Neutral links, Spreader Link and Earth bar etc. and all other accessories as applicable. including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached with complete wiring to complete job. | — | — | — | 899.46 | |
| — | 2.00 | — | — | ||
| Supply of 100A Copper Busbar Chamber Box made of Polycarbonate/ Thermoplastic of size: 450 X 300 X 210 mm or above including 4 Nos. Cu Busbar of size- 25X3mm or above as approved by competent authority, 5 sets of metal cable glands suitable for 35-95 sq.mm Alm Armoured cable. The Box should have Ingress Protection of IP65 or better, Impact Protection of IK09 or better, with rust, dust, moisture and shock proof, anti corrosive, fire retardant properties. Make: Grasp/Cape/Hensel/Any Indian Make IS standard. | — | — | — | 31,340.8 | |
| — | 2.00 | — | — | ||
| Fixing & Commissioning of 100A Copper Busbar Chamber Box made of Polycarbonate/ Thermoplastic with 5 sets of metal cable glands suitable for 35-95 sq.mm Alm Armoured cable. Cost also includes fixing of the box in wall or electric pole with suitable fixing arrangement and proper termination and connection of cables to complete the job. | — | — | — | 3,134.08 | |
| — | 4.00 | — | — | ||
| Supply of 25 KVA AT Connection box made of CRCA Sheet Steel of thickness (minimum): 2mm with power coated paint, with necessary arrangement suitable for mounting on AT mast, with Double Door arrangement (Front side openable & operatable compartmental doors and front side outer door is to be provided) to meet Ingress Protection of IP 63 or higher, a canopy at the top made of minimum 2.0mm thick CRCA Sheet Steel to protect panel from rainwater, consisting with TP 160A, 25kA MCCB [Moulded Case Circuit Breaker, 3-pole, capacity 160A, rated voltage 415V, 50Hz, conforming to IS/IEC 60947-1&2, breaking capacity 25KA, insulation voltage 690V AC or higher, capable to withstand 50°C ambient temperature, fitted with adjustable thermal magnetic overload release and fixed magnetic short circuit release, impulse withstanding voltage capacity of 8KV or higher, having indication of ON/OFF/Tripped with locking arrangement in OFF position to avoid accidental ON position]-01 No. as incoming and 200A Porcelain rewirable fuse link with 200A fuse base -03 Nos. as outgoing including internal connection with suitable size Flexible, Multistrand Cu wire of FR-LSH grade, appropriate spreader link for MCCB, Stud Terminals suitable for termination of 2 Core X 150 sq. mm Alm cable, LED Indication lamp for incoming and outgoing point, glass fuse and with rotary turn panel lock arrangement for each compartmental doors, necessary item for seal the cable entry points and necessary accessories to complete job as per site requirement and direction of Consignee. Incoming and outgoing cable entry point will be on bottom side. Only Stainless Steel (SS) clamps, fasteners, nut-bolts to be used for fixing purpose. *Warranty - 1 years. | — | — | — | 2,36,484 | |
| — | 4.00 | — | — | ||
| Installation, testing and commissioning of 25 KVA AT connection box 2.0MM CRCA metal sheet & 2mm gland plate, mast mounted, made of out door type made of cubicle type compartmentalized/ non-compartmentalized as per site requirement, water proof with necessary accessories. Stainless steel fastener, clamp nut/bolts should be used for fixing purpose or as per site requirements or as per consignee. | — | — | — | 26,276 | |
| — | 400.00 | — | — | ||
| Laying of cable/ cables in underground along the road through cable trench etc . as per standard drawing including necessary termination, connection and testing. Trenching and laying of U/G cables in any kind of soil trench of size minimum 0.40 mtr wide and 1 mtr deep covered with necessary bricks for protection of the cables including filling of space between brick and cable/cables with sand and refilling the trench with excavated soil, levelling up, and restoring the surface duly rammed. | — | — | — | 59,372 | |
| — | 100.00 | — | — | ||
| Laying of cable/ cables across the road, track, drain etc through RCC/GI pipe confirming to IS standard of size 100mm or 150mm (or any suitable size as per field requirement based on the actual size of the cable) as per relevant specification and as per standard drawing with necessary termination, connections and testing .Cost also includes collection of cable/cables from Railway store if required.GI pipe will be supplied by contractor. | — | — | — | 33,977 | |
| — | 50.00 | — | — | ||
| Laying of cable/ cables on wall / structure through PVC casing pipe of size 4inches or 3inches with accessories or as per site requirement with suitable clamp / saddle/ fixtures etc with necessary termination, connection and testing as per standard drawing. Cost also includes collection of cable/cables from Railway store if required. | — | — | — | 5,103.5 | |
| — | 200.00 | — | — | ||
| Laying of extra cables in the excavated same trench as per consignee requirement. | — | — | — | 3,684 | |
| — | 2.00 | — | — | ||
| Transportation of cables in rolls with or without wooden drums from the store of concerned SSEE or any store of SRC jurisdiction to the site of works. | — | — | — | 2,342.22 | |
| — | 10.00 | — | — | ||
| Supply, transportation and fixing of RCC Cable Route Marker size L-12",B-6" and H- 2.6" with all accessories. | — | — | — | 4,978.1 | |
| — | 16.00 | — | — | ||
| Supply, erection, testing and commissioning of LT XLPE cable gland made of stainless steel with aluminium lugs/sockets (2 Nos.) suitable for termination work of LT 2 Core X 150 sq. mm XLPE aluminium conductor armoured cable. | — | — | — | 7,360 | |
| — | 6.00 | — | — | ||
| Supply of street light LED 45 watt or higher wattage street light as per Specification No. CEE/S/185/ LED/12/21/Rev-0, 2021 dated 22/12/2021 suitable for fixing in 42.4mm arm, including system lumen efficiency 110 lm/Watt (±5%), Power factor 0.90 at full load, normal voltage of luminary: 230V AC ±5%, 50HZ, Operating Voltage range: 140-270V AC, working temperature should be -10°C to 55°C, The complete unit cubicle together with its mounting arrangement shall be subjected to shock testing as per latest IEC 61373, LED life expectancy 50000 burning hrs., Colour temperature range 5500-6500K, Colour Rendering Index (CRI) 70 with driver featuring (Constant current driver with open & short circuit protection), THD<10%, efficiency 85%, SPD for External surge protection-of minimum 10KV to be separately installed with the each fixture (As per ANSI C 136'2- 2014), Lamp shall be Distortion free, clear, heat resistance toughened glass of thickness 4.00 mm, polycarbonate lens Fire retardant FR grade, Ingress Protection of IP-66 or better, The housing shall be single housing, side entry high pressure aluminium die cast/extruded aluminium, grey colour corrosion-resistant polyester powder coated with separate optical and control gear compartments, high conductivity (LM/6/ADC12/LM24) with integral heat sink and heat proof silicon rubber, silicon gasket between housing & cover, Impact Resistance of IK-07 or better. Cover to be fixed to the housing by mean of stainless steel screws and stainless steel fastener. 1) Unit shall with stand 300 volt AC for 1 minutes and cut off. It will automatically ON when voltage comes in oparating voltage range. Warranty for free replacement for 05 years. 2) Shall be oparated with reverse polarity for 3 minutes at maximum value of voltage range between supply terminal and body off the unit. 3) Shall be tested at 1500 volt AC for 1 minutes between supply terminals and body of the unit. | — | — | — | 14,089.62 | |
| — | 6.00 | — | — | ||
| Fixing and commissioning of LED 45 watt or higher wattage street light including wiring of light from loop box with proper termination by Pin Type Terminal End Lugs including fixing to the arm by mean of stainless steel screws and stainless steel fastener as per site requirement, to complete the job. | — | — | — | 1,379.52 | |
| — | 2.00 | — | — | ||
| Supply of Automatic Supply Change Over color light signalling panels, for 3 source single phase supply suitable for 25 KVA, 240V AT as per Latest RDSO specification CLS panel | — | — | — | 2,04,966 | |
| — | 2.00 | — | — | ||
| Fixing & Commissioning of Automatic Supply Change Over color light signalling panels, for 3 source single phase supply suitable for 25 KVA, 240V AT as per Latest RDSO specification CLS panel. | — | — | — | 26,249.34 | |
| — | 50.00 | — | — | ||
| Supply of 110mm dia HDPE pipe of Grade PE-100 or as per site requirement conforming IS 4984: Latest. | — | — | — | 34,439.5 | |
| — | 50.00 | — | — | ||
| Supply of 110mm dia HDPE pipe of Grade PE-100 or as per site requirement conforming IS 4984: Latest. | — | — | — | 2,037.5 | |
| — | 40.00 | — | — | ||
| Supply, laying, fixing and commissioning of 25 x 5mm GI strip as and where required extra for earth connection, at 0.5 Mtr below ground between earth electrode and main switch/ DB/ Electric pole etc. as per site supervisor's instruction, including connection & terminating with stainless steel nut, bolt, spring, washer etc, as required. (joining shall be done by overlapping and with 2 sets of stainless steel nut bolt & spring kit complete as per IS, IE rules and site requirement. | — | — | — | 4,486.8 | |
| — | 4.00 | — | — | ||
| Supply of Earthing arrangement with supply of Hot Dip Galvanized (HDG) earth cone and all other requisite materials as per CEE/GRC's Drg. No.CEE/G/A3/P-150, Alt.1 including sump box with salt and charcoal, metalic cover etc. as per site supervisor's instruction. Cost includes supply of all materials mentioned in the Drawing including 02 mtrs 25x5mm GI strip for connection from earth electrode pipe to light pole /Rail pole etc. | — | — | — | 16,478.68 | |
| — | 4.00 | — | — | ||
| Erection of Earthing arrangement with erection of Hot Dip Galvanized (HDG) earth cone and all other requisite materials as per CEE/GRC's Drg. No.CEE/G/A3/P-150, Alt.1 including sump box with salt and charcoal, metalic cover etc. as per site supervisor's instruction. Cost includes erection of all materials mentioned in the Drawing including 02 mtrs 25x5mm GI strip for connection from earth electrode pipe to light pole /Rail pole etc. | — | — | — | 3,975.44 | |
| — | 750.00 | — | — | ||
| Supply of 2 x 150 sq. mm, XLPE Insulated, 1100 Volts Grade, LT Cable with improved fire performance category C2-FRLS, Stranded Aluminum Conductor complying with Class 2 of IS 8130, Cores Laid up, Inner sheath of PVC applied by extrusion, Galvanised round steel wire or Galvanized steel formed wire (strip) Armoured, Cores' identification by Coloured strip applied on the cores or by Colouring of XLPE Insulation, Outer Sheath of PVC Compound applied by extrusion conforming to the requirement of type ST2 as per IS 5831 & also meet the requirement of C2 Category tests under clause 15.1.1 & 15.2.1, Conforming To IS: 7098 Part-1 with amendment no. 1,2,3,4,5 or latest & ISI Marked. (i) Type Test Certificate Conforming to IS:7098 Part-1 from NABL Accredited lab has to be submitted along with the offer and along with the supply of material for similar type of cable having conductor cross-sectional area not less than the mentioned size in description. (ii) Routine test Certificate has to be Submitted along with Supply of materials. (iii) Acceptance test as per IS:7098 Part-1 has to be conducted by Inspection Agency. | — | — | — | 3,89,400 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
JPOfordiggnigwork.pdf
ATTACHMENT
LEDSpecificationScan_compressed.pdf
ATTACHMENT
JPOforconcealedwiring.pdf
ATTACHMENT
3.0GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27_04_22_1.pdf
ATTACHMENT
4.0GCC-2022Correctionslip1.pdf
ATTACHMENT
MANDATEFORM.pdf
ATTACHMENT
CerInfregEmp.Par.ofRet.RailwayEmployees.pdf
ATTACHMENT
GeneralConditions.pdf
ATTACHMENT
AdvanceCorrectionSlipNo.2.pdf
ATTACHMENT
ExplanatorynoteMidsectionAT1.pdf
ATTACHMENT
GeneralArrgt.ofEarthConeCableTrenchfor11KvPILCDSTACableCableMarker---CEE_G_A3_P-134--Alt.-Nil.pdf
ATTACHMENT
ExplanatorynoteMidsectionAT1.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .