| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹44.6 L+₹5.2 L (13.1%)Rejected-Finance R O Y K PURA QAZIGUND ANANTNAG 192221 J K | ANANTNAG | JAMMU AND KASHMIR | 192221 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹45.0 L+₹5.6 L (14.3%)Rejected-Finance BALSUA P O JHAKOLARI PATHANKOT PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹45.1 L+₹5.7 L (14.4%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹45.8 L+₹6.4 L (16.2%)Rejected-Finance 30 B 1 DEEN DAYAL NAGAR NAWABGANJ DEEN DAYAL NAGAR KANPUR NAGAR UTTAR PRADESH 208002 | KANPUR NAGAR | UTTAR PRADESH | 208002 | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | N K BUILDERS L1 | M/s Koul & Sons L4 | GANDOTRA CONSTRUCTION CO L3 | ASHISH AND CO L5 | M/S BHAT ENGINEERS L2 | SUMEET TRADING CORPORATION L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | S&F in repair SDC Laminated flooring 8mm thick of any coloured, manufactured by Direct Pressure Laminated (DPL) wherein the empty Abrasive aluminium oxide overlay alongwith metamine impregnated decorated film is directly fused with the back with flooring locking profile in designed with double click locking system on the length and single locking width alongwith desire locking strength laid over 1mm thick foam base, complete including removal of existing flooring, all as directed by the Engr-in-Charge. | 122 | Sqm | 1,300 ₹1,58,600 Lowest | 1,450 ₹1,76,900 | 1,800 ₹2,19,600 | 1,399 ₹1,70,678 | 1,430 ₹1,74,460 | 1,700 ₹2,07,400 |
| 2.00 | S&F in repair Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed by Engr-in-Charge. | 1 | Each | 1,100 ₹1,100 | 1,200 ₹1,200 | 1,200 ₹1,200 | 899 ₹899 Lowest | 1,700 ₹1,700 | 4,500 ₹4,500 |
| 3.00 | Dismantling plain or corrugated steel sheeting any guage, thickness including nainital or similar pattern roof covering and wall cladding complete all as specified and directed by Engr-in-Charge. | 348 | Sqm | 1 ₹348 Lowest | 15 ₹5,220 | 10 ₹3,480 | 9 ₹3,132 | 7 ₹2,436 | 5 ₹1,740 |
| 4.00 | S&F pre-painted galvalume aluminum zinc coating GI based corrugated/ trapzodal, semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws / L-type or J-type or cranked hook bolts in lieu of screws with bituminious washer as specified and directed by Engr in Charge. | 318 | Sqm | 800 ₹2,54,400 Lowest | 950 ₹3,02,100 | 1,200 ₹3,81,600 | 989 ₹3,14,502 | 830 ₹2,63,940 | 850 ₹2,70,300 |
| 5.00 | S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws / L-type or J-type or cranked hook bolts in lieu of screws with bituminious washer as specified and directed by Engr in Charge. | 30 | Sqm | 800 ₹24,000 Lowest | 950 ₹28,500 | 900 ₹27,000 | 989 ₹29,670 | 800 ₹24,000 Lowest | 850 ₹25,500 |
| 6.00 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in-Charge. | 0.5 | Per Qtl | 200 ₹100 | 80 ₹40 Lowest | 100 ₹50 | 99 ₹49.5 | 80 ₹40 Lowest | 500 ₹250 |
| 7.00 | M&L for Fe 410-W (Gde-E-250 qanlity-A) roof trusses(framed) ,trussed,purlins,crane gantries ,rail and fastening and heavy bracket framing (Beam,tee ,angle, channel or flat sections) including distance pieces, cleats etc directed by Engr-in-Charge. | 50 | Kg | 120 ₹6,000 Lowest | 159 ₹7,950 | 200 ₹10,000 | 159 ₹7,950 | 135 ₹6,750 | 135 ₹6,750 |
| 8.00 | M&L preparation/ complete removed of old steel surface painted / untreated surface apply two coat of synthetic enamel (ordinary tint) paint any description, over 10cm in width or girth,not otherwise described complete all as specified and directed by Engr-in-Charge. | 30 | Sqm | 80 ₹2,400 | 56 ₹1,680 | 50 ₹1,500 Lowest | 69 ₹2,070 | 85 ₹2,550 | 170 ₹5,100 |
| 9.00 | Demolition of Cement Concrete (Unreinforced) in ground floors and pavings n exc. 15cm thickness (below or above ground level), complete all as specified and directed by Engr-in-Charge. | 3.38 | Cum | 500 ₹1,690 | 80 ₹270.4 | 100 ₹338 | 49 ₹165.62 Lowest | 90 ₹304.2 | 1,500 ₹5,070 |
| 10.00 | M&L 75 mm thick PCC (1:3:6) type C2 (Using 20mm graded crushed stone aggregate) as in floor levelling and finished even and fair without using extra cement complete all as specified and directed by Engr-in-Charge. | 25 | Sqm | 400 ₹10,000 | 140 ₹3,500 Lowest | 200 ₹5,000 | 449 ₹11,225 | 275 ₹6,875 | 360 ₹9,000 |
Tender Value
₹42.9 L
EMD Value
₹85,840
Closing Date
25 Sept 2025, 6:00 pmClosed
GE 860 EWS
GE 860 EWS Karu Pin-194201
SPECIAL REPAIR TO BLDG NO. TA-150/5 AND SPL REPAIR TO OLD UNSERVICEABLE LT PANELS, LT CABLES AND CONNECTED ITEMS AT KARU AREA UNDER GE 860 EWS
2025_MES_728327_1
8193/2025-26/E8
Open Tender
Civil Works
Item Rate
270 days
KARU
As per tender documents
9 documents required · 9 mandatory
₹500
GE 860 EWS Karu
₹85,840
Yes
13 Oct 2025
29 Aug 2025
27 Sept 2025
29 Aug 2025
25 Sept 2025
12 Sept 2025
Amount
S&F in repair SDC Laminated flooring 8mm thick of any coloured, manufactured by Direct Pressure Laminated (DPL) wherein the empty Abrasive aluminium oxide overlay alongwith metamine impregnated decorated film is directly fused with the back with flooring locking profile in designed with double click locking system on the length and single locking width alongwith desire locking strength laid over 1mm thick foam base, complete including removal of existing flooring, all as directed by the Engr-in-Charge.
S&F in repair Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed by Engr-in-Charge.
Dismantling plain or corrugated steel sheeting any guage, thickness including nainital or similar pattern roof covering and wall cladding complete all as specified and directed by Engr-in-Charge.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated/ trapzodal, semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws / L-type or J-type or cranked hook bolts in lieu of screws with bituminious washer as specified and directed by Engr in Charge.
S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws / L-type or J-type or cranked hook bolts in lieu of screws with bituminious washer as specified and directed by Engr in Charge.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in-Charge.
M&L for Fe 410-W (Gde-E-250 qanlity-A) roof trusses(framed) ,trussed,purlins,crane gantries ,rail and fastening and heavy bracket framing (Beam,tee ,angle, channel or flat sections) including distance pieces, cleats etc directed by Engr-in-Charge.
M&L preparation/ complete removed of old steel surface painted / untreated surface apply two coat of synthetic enamel (ordinary tint) paint any description, over 10cm in width or girth,not otherwise described complete all as specified and directed by Engr-in-Charge.
Demolition of Cement Concrete (Unreinforced) in ground floors and pavings n exc. 15cm thickness (below or above ground level), complete all as specified and directed by Engr-in-Charge.
M&L 75 mm thick PCC (1:3:6) type C2 (Using 20mm graded crushed stone aggregate) as in floor levelling and finished even and fair without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L 75 mm thick Cement concrete type C-2, 1:3:6 (using 20mm graded crushed stone aggregate) as in floor plinth protection, finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5m and not exceeding 1.5m in depth for laying of electric cable and getting out in hard and dense soil, complete all as specified and as directed by the Engr-in-Charge.
Returning, filling in excavated soil, including leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed by the Engr-in-Charge.
Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engr-in-Charge.
Taking out old unserviceable/serviceable un-reinforced concrete PCC cable covers from excavated trench all as directed by the Engineer-in-Charge. Note:- Serviceable un-reinforced concrete PCC cable cover kept in safe custody for reuse at site and unserviceable un-reinforced concrete PCC cable cover through in low lying area.
Laying only old reinforced PCC cable cover of any size as retrieved from serial item No. 15.00 here in before complete all as directed by Engineer-in-Charge.
M&L for factory made un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for UG cable protection on the top of the sand cushioning, complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to UG cable, complete all as specified and directed by Engr-in-Charge. Note:- Only punned thickness shall be measured and paid.
S&F galvanized iron pipe of 50 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall including painting with two coats of aluminium paint over a coat of red oxide paint, complete all as specified and directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate.
Taking out old LT under ground cable from trenches / floor / road / wall / pipe / pole of any size and description incl joint, complete all as specified and directed by Engr-in-Charge.
Supply, laying, testing and commissioning of LT UG cable XLPE insulated PVC sheathed galvanized steel strip armoured electric power cable with stranded aluminium conductor 1100 volts grade 185 sq mm 3.5 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as specified and directed by Engr-in-Charge. Note : 1. The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items.
Description all as Srl item No. 21.00 here in before but for cable size of 150 sqmm 3.5 core.
Description all as Srl item No. 21.00 here in before but for cable size of 120 sqmm 3.5 core.
Description all as Srl item No. 21.00 here in before but for cable size of 70 sqmm 3.5 core.
Description all as Srl item No. 21.00 here in before but for cable size of 50 sqmm 3.5 core.
Description all as Srl item No. 21.00 here in before but for cable size of 35 sqmm 3.5 core.
Description all as Srl item No. 21.00 here in before but for cable size of 25 sqmm 4 core.
Description all as Srl item No. 21.00 here in before but for cable size of 16 sqmm 4 core.
Description all as Srl item No. 21.00 here in before but for cable size of 16 sqmm 2 core.
Description all as Srl item No. 21.00 here in before but for cable size of 10 sqmm 2 core.
Taking out old UNSV LT panel board / Junction box of any size complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC. Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 400 Amps, 415 Volt, AC ,50 KA = 01 No (I/C) (b) MCCB 4 pole, 200 Amps, 415 Volt, AC ,25 KA = 01 No (O/G) (c) MCCB 4 pole, 160 Amps, 415 Volt, AC, 16 KA = 02 Nos (O/G) (d) MCB SPN 63 Amps, 230 Volts = 10 Nos (O/G) (d) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS 485 Make : L&T
(e) Phase indicating lamp = 03 Nos (R, Y, B) (f) Aluminium bus bar of capacity 600 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four (g) Panel drawing shall be got approved from GE before placing order. Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC. Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 250 Amps, 415 Volt, AC ,25 KA = 01 Nos (I/C) (b) MCCB 4 pole, 100 Amps, 415 Volt, AC, 16 KA= 01 Nos (O/G) (c) MCCB 4 pole, 63 Amps, 415 Volt, AC, 16 KA= 03 Nos (O/G) (d) MCB SPN 63 Amps, 230 Volts, AC = 04 Nos (O/G) (e) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 Make : L&T
(f) Phase indicating lamp = 03 Nos (R, Y, B) (g) Aluminium bus bar of capacity 400 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four (h) Panel drawing shall be got approved from GE before placing order. Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC. Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 160 Amps, 415 Volt, AC ,16 KA = 01 No (I/C) (b) MCCB 4 pole, 63 Amps, 415 Volt, AC, 16 KA= 02 Nos (O/G) (c) MCB SPN 63 Amps, 230 Volts, AC = 04 Nos (O/G)
(d) Aluminium bus bar of capacity 200 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four (e) Panel drawing shall be got approved from GE before placing order. Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
(f) Aluminium bus bar of capacity 200 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four (g) Panel drawing shall be got approved from GE before placing order. Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, Junction box , cubical type, factory made, outdoor type of Size 45cm(l)x30cm(w)x60cm(h) , dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, complete with openable shutters in front and rear having proper locking arrangement including including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC and aluminium bus bar of size 400 Amps capacity , Three phase and neutral bus bar , making hot and cold drilling holes to aluminium bus bar . Junction box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge.
M&L in replacement Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth strip protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 25 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 5 of SSR 2009 Part-I and connecting to Poles all as specified or indicated including testing on complete all as specified and as directed by Engineer-in-Charge.
M/S BHAT ENGINEERS (BID ID -3429426)
GANDOTRA CONSTRUCTION CO (BID ID -3429151)
M/s Koul & Sons (BID ID -3428946)
ASHISH AND CO (BID ID -3435262)
SUMEET TRADING CORPORATION (BID ID -3429270)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .