| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-AOC | L1 | Accepted-AOC Accepted due to lowest rate quoted | |
| 2 | L2₹21.8 L+₹1.9 L (9.70%)Rejected-Finance | L2 | Rejected-Finance Rejected due to highest rate quoted. |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
12 Sept 2024, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
REPAIR/REPLACEMENT OF JOINERY BRICK WORK ALUMINIUM WORK EXTERNAL/INTERNAL PLASTERING FLOORING TILING SANITARY FITTINGS PERIODICAL SERVICES INCL INTERNAL E/M WORKS AT AF STN INDAUR AND REPAIR/REPLACEMENT OF ROOF TREATMENT IN CERTAIN SMQ/OMQ AND OTM AC
2024_MES_666566_1
GE/GUR-/NIT-19/2024-25
Open Tender
Civil Works
Item Rate
240 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹80,000
21 Sept 2024
18 Jul 2024
14 Sept 2024
18 Jul 2024
12 Sept 2024
1 Aug 2024
Amount
M&L for preparation of plastered or unplastered old decorated surfaces by complete removal of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7"/9" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible , filling of holes and cracks with with suitable material like cement or plaster of paris etc and thereafter applying two coat of oil bound distemper over a coat of primer on walls complete all as specified and as directed. Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engg-In-Charge in stage passing register before applying the finishes coat. (b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer. (c) Wall care putty shall be measured and paid seperately.
All as per item No.1 here-in-before but on surfaces of ceiling.
M&L for providing 1-3mm thick wall care putty on wall before applying oil bound distemper and making the surface uniform complete all as specified and as directed. Note: OBD to be measured and paid saperately.
M&L for preparation(complete removal of existing treatment) of old decorated external wall/ceiling surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7"/9" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint over a coat of primer premium quality on wall/ceiling surface including applying 1-2mm thick wall care putty over disturbed surface during preparation of any reason, sand papering thus make surface smooth upto 4th storey buildings complete all as specified and as directed. Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engg-In-Charge in stage passing register before applying the finishes coat. (b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer.
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10cm width or girth by cleaning, sand papering,brushing etc , filling in cavities and cracks etc with approved filler and applying one coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified and as directed.
Taking down cement plaster or cement lime plaster on brick,concrete or stone surfaces including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for 5 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:3 in ceiling including finishing surface even and smooth without using extra cement complete all as specified and as directed.
M&L for 10 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:6 on walls including finishing surface even and smooth without using extra cement complete all as specified and as directed.
M&L for 15 mm thick plaster in cement mortar (1:4) on brick or concrete surfaces including rendering on fins, fascias, chajja, parapets etc and finishing the surfaces even and fair (without using extra cement) complete all as specified and as directed.
M&L for preparation of newly plastered or unplastered/undecorated surface of wall and applying two coats of oil bound distemper over one coat of primer complete all as specified and as directed.
M&L for preparation of newly plastered or unplastered/undecorated surface of ceiling and applying two coats of oil bound distemper over one coat of primer complete all as specified and as directed.
M&L for preparation of newly plastered surface of wall and applying Two coats of wheather proofing exterior acrylic emulsion paint over a coat of primer premium quality complete all as specified and as directed.
Taking down of aluminium frame/doors/windows from site dismantling aluminium structure such as glass, rubber beading aluminium clips complete all as specified and as directed.
S&F Powder coated Aluminium frame for doors, windows, ventilators with or more rebates incl. jointing cleat for fixing etc. complete all as specified and as directed.
S&F powder coated anodized aluminum door shutters, aluminum section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing handles 2 Nos in each door,100 mm long hinges (3 Nos), anodized aluminum snap beading screws etc. complete all as specified and as directed.
M&L for 5.5 mm thick sheet glass ordinary quality and glazing each pane fixed with including neopune rubber gasket in aluminium frame work complete all as specified and as directed.
S&F in repair Mortice lock, vertical type of brass 100 mm 4 Levers with duplicate keys complete all as specified and as directed.
S&F in repair aluminium (Die cast) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed.
Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 250 liters but not exceeding 500 litres complete all as specified and as directed.
S&F for rotational moulded polyethylene water storage tanks 500 ltrs capacity (cylinderical vertical with closed top) hoisted and fixed in position complete all as specified and as directed.
Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 500 liters but not exceeding 1000 litres complete all as specified and as directed.
S&F for rotational moulded polyethylene water storage tanks 1000 ltrs capacity (cylinderical vertical with closed top triple layered) hoisted and fixed in position all as per SSR Part I complete all as specified and as directed.
S&F in repair ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm bore and fixed, minimum weight of float valve 210 gms complete all as specified and as directed.
S&F in repair 25 mm outer dia medium weight pipe made out of stainless steel 304 grade, including decorative ornamental knobs at both ends and one set of ornamental decorative Stainless steel clamps to fixed to walls complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and as directed.
All as per item No.25 here-in-before but exc 1.5 Sqm and not exc 4 Sqm each complete all as specified and as directed.
Taking down shutter of any description exc 1 Sqm and n exc 2 Sqm and removing from site complete all as specified and as directed.
S&F factory made 35mm thick flush shutters , solid core construction with block board core and plywood face pannel commercial type on both faces complete all as specified and as directed.
S&F factory made 35mm thick 2nd class hardwood glazed and skelton door shutters, open rebated and prepared to receive glass, gauze, (without sash bars) edges for framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part-1 section 8 clause 8.24 (a) fitted to chowkats complete all as specified and as directed.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified and as directed.
S&F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified and as directed.
M&L for preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
S&F 100 mm Butt hinges, Stainless steel and fixed complete all as specified and as directed.
S&F 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.
S&F 150 mm size extruded aluminium alloy handles fabricated type anodised and fixed complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or escription) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed.
S&F in sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads complete all as specified and as directed.
S&F for Pressed steel frames 125X60mm (made out of 1.25mm thick MS Sheet) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and as directed.
S&F for Pressed steel frames 105X60mm (made out of 1.25mm thick MS Sheet) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and as directed.
M&L for prepration of new Steel surfaces of any description, not otherwise descri-bed, over 10cm width or girth & applying two coats of synthetic enamel paint complete all as specified and as directed.
Demolition of Mud in roofs, any thickness including plastering and leeping, (whether full thickness removed etc including roof tiles complete all as specified and as directed.
M&L for 50 mm thick PCC (1:2:4) type B-0 (Using 12.50mm graded stone aggregate) as in roof padding complete all as specified and as directed.
M&L for 15 mm thick plaster in cement mortar (1:4) mixed with water proofing compound on roof slabs finished even and smooth (without using extra cement) after cleaning of roof surfaces with wire brushes complete all as specified and as directed. Notes : WPC shall be measured and paid seperately.
M&L for water proofing treatment with APP (Atactic Polypropylene) modified polymeric prefabricated five layer membrane over roof consisting of cleaning of concrete or plaster surface of roof & parapet walls and applying evenly a bitumen primer confirming to IS 3488 @ 0.40 Kg per sqm laid using buten torch and sealing all joints of APP modified polymeric water proofing membrane minimum weight 3.6 kg/sqm reinforced with non woven polyester fabric (weight not less than 160 grams per sqm) unrolled and bonded to substrata with logitudinal and end laps 100 mm and 150 mm respectively as per manufacturer's instructions complete all as specified and as directed.
M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed.
M&L for providing plain cement concrete (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregate) as in coping in chajjas or roof kerbs on roof chamfered on edge including trowelling slightly complete all as specified and as directed.
M&L for Cement concrete tiles 25cm x 25cm x 22 mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished, set with grey cement and pigments over 15mm thick cement screed bed in cement mortar 1:4 complete all as specified and as directed.
Supply only intergral water proofing compound ISI Marked complete all as specified and as directed.
Removing bldgs demolished materials / debries exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified and as directed.
Demolition of brick work or rubbled stone masonry including all quoins arches , pillars etc built in cement mortar and including removal from the site complete all as specified and as directed.
M&L for brick work with sub class 'B' old size brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:6 etc complete all as specified and as directed.
M&L for half brick work with sub class 'B' old size brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:4 etc complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint on walls complete all as specified and as directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Fixing only old serviceable medium grade galvanized steel tubing with all new fittings to walls & ceiling or laid in floors 15 mm dia bore pipe (including in short length) complete all as specified and as directed.
Fixing only old serviceable medium grade galvanized steel tubing with all new fittings to walls & ceiling or laid in floors 20 mm dia bore pipe (including in short length) complete all as specified and as directed.
Disconnecting existing PVC water tank of capacity exc. 250 ltr but not exc. 500 ltr, setting aside for lowering down if required for repairs,hoisting if required reconnecting and refixing in position on roof including cleaning of Overhead tank & removing the sludge washing down with detergent/ bleaching powder and writing the date of cleaning with suitable paint complete all as specified and as directed.
Disconnecting existing PVC water tank of capacity exc.500 ltr but not exc. 1000 ltr, setting aside for lowering down if required for repairs,hoisting if required reconnecting and refixing in position on roof including cleaning of Overhead tank & removing the sludge washing down with detergent/ bleaching powder and writing the date of cleaning with suitable paint complete all as specified and as directed.
S&F in repair 110mm dia PVC (SWR) pipe and single socketed in any length with rubber ring joint fixed to wall complete all as specified and as directed.
S&F in repair PVC (SWR) bends any radius 110 mm bore complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring light ,fan, socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and as directed.
Taking down old unserviceable main switch/DBs/mcb DBs with MCB including making good the disturbed surface complete all as specified and as directed.
Taking down old existing light fitting of any type complete all as specified and as directed.
Taking down sub main wiring of any size including making good the disturbed surfaces complete all as specified and as directed.
M&L for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawn through in and including PVC conduit size of not less than 20mm concecled in wall / surface including provn of pressed steel terminal box of suitable size with 3mm thick plastic laminated sheet cover for mounting switch, socket and regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm complete all as specified and as directed for the following:-
(a) One light point controlled by one switch one way.
(b) One celling/exhaust fan point controlled by one switch one way.
(c) One socket out let 5 Amps 5 pin on independent board.
(d) One socket outlet 5 Amps 5 Pin on same board with other switches.
(e) One bell/buzzer point controlled by one bell push on independent board.
All as per item No 66 here in before but with cable size 2.5 Sq mm for one 3/5 pin 15 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 1.5 sqmm complete all as specified and as directed.
S&F in replacement of switch piano, flush type, 5 amps, single pole, one way complete all as specified and as directed.
S&F in replacement of socket outlet 2in1, 3 pin 5 Amps flush type complete all as specified and as directed.
S&F in replacement of socket outlet 2in1, 6 pin 15/5 Amps flush type complete all as specified and as directed.
S&F in replacement of switch piano, flush type, 15 amps, single pole, one way complete all as specified and as directed.
S&F in replacement of ceiling rose surface bakelite two to three terminals complete all as specified and as directed.
S&F in replacement of bell push , 5 amps, single pole, one way complete all as specified and as directed.
S&F in replacement of call bell, Ding dong type, 230 volts AC single pole complete all as specified and as directed.
S&F in replacement of ceiling fan regulator stepped electronic type 300 watt rating complete all as specified and as directed.
S&F in replacement of modular switches 6 amps single pole one way complete all as specified and as directed.
S&F in replacement of modular switches 16 A single pole one way complete all as specified and as directed.
S&F in replacement of modular socketes out let 6 amps 5 pin complete all as specified and as directed.
S&F in replacement of modular socket out let 6-16 A 3 pin combined shuttered complete all as specified and as directed.
S&F in replacement of modular white cover plate with frame 3 modular complete all as specified and as directed.
S&F in replacement of Flush metal boxes 3 modular complete all as specified and as directed.
S&F in replacement of modular white cover plate with frame 6 modular complete all as specified and as directed.
S&F in replacement of Flush metal boxes 6 modular complete all as specified and as directed.
S&F in replacement of modular white cover plate with frame 8 modular complete all as specified and as directed.
S&F in replacement of Flush metal boxes 8 modular complete all as specified and as directed.
S&F in replacement of MCB distribution board vertical triple pole and neutral 8 way factory made sheet steel, phosphates, powder painted with 200 Amps rated busbar, 415 volts, neutral link, earth bar and Din rail double door complete all as specified and as directed.
S&F in replacement of MCB distribution board triple pole and neutral 4 way factory made sheet steel, phosphates, powder painted with 200 Amps rated busbar, 415 volts, neutral link, earth bar and Din rail double door complete all as specified and as directed.
S&F in replacement of MCB distribution board single pole and neutral 8 way factory made sheet steel, phosphates, powder painted with 100 Amps rated busbar, 240 volts, neutral link, earth bar and Din rail double door complete all as specified and as directed.
S&F in replacement of MCB distribution board single pole and neutral 4 way factory made sheet steel, phosphates, powder painted with 100 Amps rated busbar, 240 volts, neutral link, earth bar and Din rail double door complete all as specified and as directed.
M&L for Sub main wiring with 2 Run of 4 Sqmm cable and one run of 4. sqmm as earth wire PVC insulated, unsheathed FR cable of multistranded copper conductors 1100 volt grade IS- 694 marked drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories concealed on wall and surface on ceiling complete all as specified and as directed.
M&L for Sub main wiring with 2 Run of 2.5 Sqmm cable and one run of 2.5. sqmm as earth wire PVC insulated, unsheathed FR cable of multistranded copper conductors 1100 volt grade IS- 694 marked drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories concealed on wall and surface on ceiling complete all as specified and as directed.
S&F in replacement of sheet metal enclosure with socket plug top and MCB single pole and neutral with two pin and earth plug with one SP MCB 20 Amp 240 volt complete all as specified and as directed.
S&F in replacement of geyser assembly suitable to fix thermostat , heating element as of the existing model & size including all clamps with bolts and nuts etc complete all as specified and as directed.
S&F in replacement of heating element 2000 watt capacity triangular type complete all as specified and as directed.
S&F in replacement of capacitor 2.5 md 230 volts 50 Hz complete all as specified and as directed.
Supply and Fixing in repair of wall mounting fan 400 mm sweep 230 Volt oscillating type complete all as specified and as directed.
Supply and Fixing in repair of Exhaust fan 300 mm sweep 230 Volt plastic body type complete all as specified and as directed.
S&F in replacement of MCB SPN 63 Amps, 10 KA,240V, 50Hz, 'C' Series complete all as specified and as directed.
S&F in replacement of flexible conduit of size 25 mm complete all as specified and as directed.
S&F in replacement of lights fitting luminaires with 18 watt LED sleek pressure die cast aluminium housing ,heat resistance toughened glass with IP protection for better optics fo uniform distribution internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.
S&F in replacement of PVC gang box suitable for one switch and socket 5/15 Amps complete with screw and necessary arrangement complete all as specified and as directed.
ditto but suitable for one switch and socket 15 Amps complete all as specified and as directed.
KISHAN SINGH AND CO (BID ID -3086047)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .