Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.7 LAccepted-AOC PLOT NO 10 9 OM VIHAR PHASE 1 A UTTAM NAGAR NEW DELHI 110059 | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹30.4 L+₹19,012.15 (0.63%)Rejected-Finance | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹31.4 L+₹1.2 L (4.09%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹35.9 L+₹5.8 L (19.1%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹38.1 L+₹7.9 L (26.3%)Rejected-Finance | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
3 Feb 2024, 6:00 pmClosed
GE (CENTRAL) DELHI CANTT-10
GE (CENTRAL) DELHI CANTT-10
REPAIR/ REPLAECMENT OF PLASTERING, TILING, CEILING, ROOF TREATMENT, DAMP PROOFING INCLUDING REPAIR/ REPLACEMENT OF INTERNAL WIRING, DB, MCB AND MISC WORK AT CADET MESS AND CADET LINES OF RRRC AND ADJOINING AREA UNDER GE (CENTRAL) DELHI CANTT-10
2024_MES_635971_1
GE/C-77/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (CENTRAL) DELHI CANTT-10
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE (CENTRAL) DELHI CANTT-10
₹1 L
Yes
1 Mar 2024
5 Jan 2024
5 Feb 2024
5 Jan 2024
3 Feb 2024
19 Jan 2024
5 Jan 2024 - 19 Jan 2024
Amount
Demolition of brick work built in cement or cement lime mortar of any description including quoins,arches,pillars,etc. all as directed.
M & L for brick work with Cement Mortar1:6 using sub class 'B' bricks,old size , straight or curved on plan exceeding 6 m mean radius all as specified and directed.
Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubing down with water etc up to 10m height complete all as specified and directed.
M&L for 15mm thick ready mix cement plaster with bulk density 1.4 to 1.70KG per ltr water ration 17 to 19% by weight with compressive str as per IS 4031 part-VI applied as per the manufactore instr incl necesaery cement screed and prepartion of surface to received ready mix plaster up to 10m height. complete all as specified and directed by engineer-in-charge complete all as specified and directed complete.
M&L for 10mm thick ready mix cement plaster with bulk density 1.4 to 1.70KG per ltr water ration 17 to 19% by weight with compressive str as per IS 4031 part-VI applied as per the manufactore instr incl necesaery cement screed and prepartion of surface to received ready mix plaster up to 10m height. complete all as specified and directed by engineer-in-charge complete all as specified and directed.
M&L for 5mm thick ready mix cement plaster with bulk density 1.4 to 1.70KG per ltr water ration 17 to 19% by weight with compressive str as per IS 4031 part-VI applied as per the manufactore instr incl necesaery cement screed and prepartion of surface to received ready mix plaster up to 10m height. complete all as specified and directed by engineer-in-charge complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint complete all as specifed as direted by Engr-in-charge.
M & L for applying two coats of oil bond destember over one coat of birla white wall care putty on newly plastered surfaces(internal) of walls complete all as specified and directed.
M&L preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newly plaster surface of wall and applying two coats of plastic emulsion paint over 2mm thick wall care putty complete all as specified and all as directed by Engr- in-charge.
M&L for preparation of newly plaster surface of wall and applying two coats of weather proof acralic exterior emulsion paint complete all as specified and all as directed by Engr- in-charge.
M&L for preparation of old decorated plastered surfaces of walls, complete removal of existing treatment by washing, rubbing down with water etc and applying two coats of weather proof acralic exterior emulsion paint up to 10 m height complete all as specified and directed.
M&L for old decorated surfaces plastered or unplastered surface of wall and complete removal of existing treatment by washing, rubbing etc and applying two coat of oil bond distemper on wall complete all a spcefied.
M&L for preparation of old decorated plastered surfaces of walls, complete removal of existing treatment by rubbing , brooming down,washing with water etc and applying two coat of cement based paint up to 10 m height complete all as specified and directed.
M & L for preparation of Old surface (Plastered or un plastered) on ceiling by completely scraping/ removing the existing treatment and applying two coats of white wash complete all as specified and directed.
M&L preparation of Old or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified.
M & L for preparation of Old or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint.
Servicing and greasing of aluminium door, windows including replacement nut , screws rubber gaskets, pivot, taper clip etc including taking down carefully of door shutter for replacing unserviceable parts/components by new parts /components for smooth functioning of door and refixing the same in existing opening/position, complete, all as specified and directed.
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed includind taking down and refixing of shutter as in repairs complete all as specified and directed.
S&F in repair aluminium body hydraulically Door closer regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed as in repairs complete, all as specified and directed.
S&F in repair for 300 mm MS ordinary rat tail rod pattern spring including roller and roller plate complete fixed on wooden frame or on wall with wooden plugs and set in cement mortar all as directed.
S & F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed.
Supply and fix in repair figured glass pin head type 4mm thick ordinary quality and glazing with oil putty in squares not exc 0.5 sqm in each pane fixed with oil putty or wooden beads including provision of glazing pins/ spring clips wherever necessary, complete all as specified.
Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 15mm.
Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 20mm.
Supply and fix galvanized steel tubing, 15 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed.
Supply and fix galvanized steel tubing, 20 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed.
Cutting chases, pinning in, for brick walls built in cement mortar, making good to facings where required and pointing in cement mortar 1:3 or PCC 1:2:4 type B-O(using 12.5 mm graded aggregate) as required for conceled water tubing etc cutting exceeding 10cm girth but not exc. 20 cm all as directed.
Supply and fix in repair for vitreous china wash hand basin with pedestal type of size 550X400mm excluding taps, incl waste pipe & waste fittings with pedestral complete all as specified.
S & F in repair for vitreous china wash hand basin (oven type) white of size 550X400mm excluding taps, waste chain and plug and porcelain stopper including a pair of mild steel angle iron brackets of suitable size and waste pipe & waste fittings complete all as specified.
S & F in repair for floor mounted EWC one piece incl all necessary fittings complete all as specified and directed by Engr -in-charge.
S & F in repair for vitreous china wash down water closet pan (padestal pattern) white making good the disturbed surface to match with the existing complete all as specified and all as directed.
S&F in repair for Toilet paper holder of vitreous china fixed to walls with chromium plated (CP) brass screws all as specified and as directed.
S & F in repair Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging devic.
S & F in repair kitchen plate rack with four shelves made out of stainless steel sheet 1mm thick over all size 75cm X75cm X 20cms complete all as specified & directed.
S & F for sink with drainage board made of stainless steel 1mm thick for kitchen with plugs, washers and waist including bedding in cement mortar to dwarfwall or including fixing cantilever, brackets and connecting union to pipe overall size 915x460mm, bowl size 410x330x160mm complete all as specifed as direted.
S & F in repair for PVC low level white flushing cistern valveless syphonic action type 10 lts capacity IS marked with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC,(ISI Marked) complete all as specified.
S & F in repair for 15 mm dia 600mm long PVC connections with brass check nut complete all as specified.
S & F in repair for Glass Corner Shelf 6mm thick including CP railing radius 250mm complerte all as specified and directed by Engineer-in-Charge.
S & F in repair for Glass shelf assembly 5.5mm thick, 600mm long 120mm wide with cp railing complerte all as specified and directed by Engineer-in-Charge.
S & F in repair for Health faucet, CP brass with 1.50m long flexible pipe complerte all as specified and directed by Engineer-in-Charge.
S & F in repair for bib taps 15 mm bore chromium plated brass, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified.
S & F 15mm dia Pillar taps, brass CP, with capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair for angle valve, fancy type, chromium plated brass, 15mm, complete all as directed.
S&F in repairs 2-in-1 angle valve, fancy type, chromium plated brass, 15mm, complete all as directed.
S&F in repair for 15 mm bore gate valve,cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as directed.
S&F in repair for 20 mm bore gate valve,cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as directed.
S & F in repair for Chromium plated brass overhead shower with arm complete all as specified and directed.
S&F in repairs chromium plated brass central hole WHB mixer 15 mm bore chromium plated, fancy type including joints to hot and cold complete all as specified.
S&F in repair for brass chromium plated mode 3 in 1 wall mixture model Quarter half turn (SOLO) complete all as specified and directed.
Demolition of stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed.
M & L for vetrified ceramic tiles of size 600 x 600 x 9-10mm thick as in floor over 15mm thick screed bed 1:6 in cement mortar, set and jointed in white cement with pigment to match all as specified and directed.
M & L vetrified ceremic tiles coloured of size 600 x 100 mm x 9-10 mm thick on vertical surfaces as in skirting etc over 10mm thick backing coat in CM 1:4, set and jointed in white cement with pigment to match all as specified and directed.
M & L for glazed ceramic tiles of size 300x600x7-8mm thick in vertical surfaces of wall set and jointed in neat cement slurry as per manufacturers instructions and pointed in white/ coloured cement, laid over and including cement screed bed 10mm thick in cement mortar 1:4, complete all as specified .
M & L for coloured non skid ceramic tiles of size 300x300x 7-8mm as in floors, set and jointed in neat cement slurry as per manufacturers instructions and pointed in white/ coloured cement, laid over and including cement screed bed 15mm thick in cement mortar 1:6, complete all as specified.
Dismentling asbestos cement corrugated or semi corrugated sheets in roof fixed with L hook or cranked bolt.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
M&L PCC 1 : 4 : 8, type D2, using 40mm graded stone aggregates, as in foundation etc complete all as specified.
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
M&L providing and applying the plaster with single component ready to use repair mortar (SMART CARE REPAIR MORTAR or equivalent) capable of applying 15mm average thickness in single layer and finishing with trowel with a bond coat: SBR polymer (@ 10% of cement weight) modified cementious bond coat @ 2.2 kg cement/Sqm of surface area mixed with specified portion of AP SMARTCARE or equivalent Repair Polymer including taking down existing roof treatment of any type and also taking down cement plaster on brick/concrete surfaces, including raking out joints, hacking for key, scrubbing down with water etc., to receive further treatment, complete all as specified land as directed. Note: The application shall be executed on any type of surface and on horizontal/Vertical areas.
M&L providing and applying Smartcare Dampproof, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on horizontal/vertical surfaces of roof/wall/chajas in multiple coats @2.0 litre/sqm. Primary [coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1, damp proof : water) and other coats to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per the direction of Engineer-in-Charge. Notes: (a) The work shall be executed through authorised applicator of manufacturer only. (b) Authrised Applicator shall be approved by GE before starting of work. (c) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material. Engineer-in-Charge shall deface the original purchase vouchers. (d) MOU with authorized applicator will be submitted by contractor before opening of (f) bid. (d) A guarantee amount of 5% of contract of work done for item No 11, 12, 63 and 64 of BOQ will be retained for 5 years of the completion of work.
Disconnecting existing 500/1000 ltr tanks, setting a side (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed.
Demolation Bricks (laid flat or on edge) or brick tiles in floors, roof, channels, kerbs, aprons, etc. (each layer all as specified and directed.
Demolition Mud in roofs, any thickness, including plastering and leeping (whether full thickness emoved or only a part thereof) all as specified and directed.
Removing soil excavated material exc. 5Km and depositing where directed at a level n exc. 1.5 m above the starting point all as specifed and directed.
M&L for cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) on roof padding with water proofing compound surface finished even and smooth without using extra cement complete all as spd & directed. (Rate of WPC shall be included in unit rate).
Supply and fix welded steel wire fabric(MS Jali) fixed to steel members weight n. exc. 4 kg/sqm incl welding complete all as specified and directed.
Demolition of cement concrete (un-reinforced) as in sunken floors, paving and any position and any thickness upto double story building including removal of rubbish out side complex (MOD land) , complete all as specified and directed.
Supply and apply a glass fibre reinforced acrylic modified cementitious coating system.Prepration of surface of sunken portion and M & L for glass fibre reinforced acrylic modified cementitious coating system as top coat over reinforcement over base coat etc supply and apply a protection plaster (12-15 mm) admixed withappropriate integral waterproofing compound @ 0.10 kg per bag of cement. The product should conforms to IS2645. Cleaning of RCC surface to remove dust, loose particles grinding any sharp edges including M&L for sealaing of pipe penetration of toilets core cutting in the following stages:- Supply and apply solvent free, moisture insensitive epoxy resin based patch repair putty on pipe penetration surfaces. The putty shall be applied to a groove thickness of minimum 20mm on pipe penetration joint to concrete complete all as specified and directed.
M & L for PCC 1:5:10 type E-2 (using 40mm graded brick aggregate) use as in sunken floor finished even and smooth without using extra cement complete all as specified and directed.
Supply and fix galvanized steel tubing, 40 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed.
Dismantling of wall and ceiling/cup board board fibre pulp AC boards etc any thickness including cover fillets removing the wiring and refixing the same including fixture as necessary at site including frame work.
M and L Providing & Fixing False ceiling with semi perforated 12mm thcik micro tegular edged at all heights with GRG (Glass Fibre reinforced Gypsum) false ceiling tiles of size 595x595mm of approved texture, design and pattern having moisture content less than 2%,humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part-4)-1970 and light Code Description unit rate No 429 SUB HEAD :26.0 NEW TECHNOLOGIES AND MATERIAL reflectance of 85% minimum to be laid in true horizoatal level suspended on interlocking metel T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @ 120 grams oer sqm including both sides) comprising of main-T runners of size 15x32mm of length 3000mm, vross-T of size 15x32nn of lenght 1200mm amd secondry itermediate cross-T of size 15x32 of lenght 600mm to form grid module of size 600x600mm, suspended from ceiling using galvanised mild steel items (galvanising @ 80 grams per sqm) ie. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000mm to be fixed on perimeter wall/partition with the help of plastic rawl pluhs at 450mm center to center and 40mm long dry wall screws. The work shall be carried out as per specification, drawing and as per direction of the Engineer-in-charge.
Taking down chowkhat or frame not exceeding 1.5 sqm each with shutter (without taking off shutter from the frame).
Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame).
Taking down shutters of any discription not exceeding 1 sqm each all as specified and as directed.
Taking down shutters of any discription exceeding 2 sqm each all as specified and as directed.
Dismantling timber scantlings 40 Sqcm and over in section, in any position unframed work complete, all as specified and directed .
S & F in repair Pressed steel frames box type made of 1.25 mm thick MS Sheet double rebates of size 125x60mm for doors, ventilator with double rebates including necessary fixing lugs, hinges, lock strike plate etc, incl PCC 1:3:6 type C1 (using 12.5mm graded stone agg) to fill the frame & making good complete all as specified & directed by Engr-in-Charge.
S & F in repair Pressed steel frames box type made of 1.25 mm thick MS Sheet single rebates of size 105x60mm for doors, ventilator including necessary fixing lugs, hinges, lock strike plate etc, incl PCC 1:3:6 type B1 (using 12.5mm graded stone agg) to fill the frame & making good complete all as specified & directed by Engr-in-Charge.
M&L for Plain, solid, straight chowkats and frames made of 2nd class hard wood (sal), wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints, supplied and fixed,making good , and including dismantling complete all as specified and as directed by Engineer-in-Charge.
M&L Mild steel frame work as in door chowkhats with angle iron welded together ends of angle shouldered and fixed to opening and welding 3 Nos mild steel butt hinges 100 mm size, and 6 nos hold fasts made out of FI 25x3 mm 30 cm long for fixing of chowkhats( Butt hinges paid sep) all as spd.
S & F in repair 35 mm thick 2nd class hard wood glazed and skelton shutter devided into square with plain, chamferred or rounded sash bar and fitted with cut and mitred beads for securing glass, size of members as per SSS Part - I section 8 clause 8.24 (b).
M & L for 30 mm thick 2nd class hardwood plain, framed, panelled shutters (two panels), with lock rail and panel of 9mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. the size of rail and stile as per IS:1003 (Part-I) kiln seasoned and chemically pressure treated.
S&F for 30 mm thick flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides and fitted to chowkhats complete all as specified and directed.
M&L aluminium alloy powder coated windows including aluminium coated frames, silding track frame bottom weighing not less than 1.015 kg/Rm ,sides and top not less than 0.826 kg/Rm double revated and 0.55 kg/Rm for window shutter with one fixed glazed shutter and two nos glazed/gauged shutter silding type with aluminium sectins as per series-A (15mm) 3 track of jindal section number for silding windows with framed shutter including aluminium allow powder coated snap type beads handles with locking arrngement spring action and glazing clips joint cleats rubber gaskets etc inclding provision of 5.5 mm thick tinted frosted glass of superior quality and stainless steel jail including all standard fittings complete all as specified and directed.
M&L aluminium alloy powder coated door including frame and channel of section (Door frame single grove 101.6mm x44.45 mm x2.1,shutter top section 47.62mm x44.45x1.95mm thick shutter bottem vertical section 85 mm x44.45 mm x1.80mm yhick ,shutter middle section 83.50mm x 44.45 mm x1.80mm thick shutter glazing clips weighing not less than 0.097 kg/Rm as directed and approved by GE and as per IS specification including provn of 5.5mm thick tinted glass/12mm thick thick prelaminated particle board as required including sling bolt 300mm, alu hinges 150 mm, alu handle 150 mm ,tower bolt 150 mm , "SAMRAT" ,looking arrangement "GODREJ" rubber gasket and door stopper complete all as specified and directed.
Material and labour for aluminium alloy Powder coated standard 10mm section and opening of size window grill as per approved sample and as per IS specifications complete all as specified and as directed.
Servicing and greasing of aluminium door including replacement nut , screws rubber gaskets, pivot, taper clip etc including taking down carefully of door shutter for replacing unserviceable parts/components by new parts /components for smooth functioning of door and refixing the same in existing opening/position, complete, all as specified and directed.
Factory made signle extruded WPC (Wood Polymer Composite) solid door/ window/ ceosetory windows and other frames/ chowkhat of size 45x70 mm comprising of virgin PVC polymer of K value 58-60 (suspension grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750kg/ cum, screw withdrawl strength of 2200N (Face) and 1100 N (edge), minimum compressive strengthy of 58N/ mm2, modules of elasticity 900 N/ mm2 and resistance to spread of flame of being termite / borer proof, water/ moisture proof and fire retardant and fixed with MS hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engr-in-Charge. (MS hold fast/ lugs or SS dash fasteners shall be paid for separtely). Note: For WPC solid door/ Window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. variation in profile dimensions on plus side shall be acceptable but not extra payment on this account shall be made.
Factory made signle extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (suspension grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650kg/ cum and screw withdrawal strngth of 1800N (Face) and 900 N (Edge), minimum compressive strength 50N mm2, modulus of elasticity 850N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixing with stainless stell butt hinges of requried size with necessary full body threaded star headed counter sunk SS screw, all as per direction of Engr-in-Charge. Note: Stainless steel butt hinges and necessary SS screws shall be paid separtely.
S&F in repair MS butt hinges medium weight 100 mm size fixed with MS screws.
S&F in repair aluminium anodised barrel tower bolt extruded section 150 mm long and fixed with MS screws.
S&F in repair 150 mm extruded aluminium alloy handle anodised fabricated type and fixed with mS screws.
S&F in repair 300 mm extruded section aluminium alloy anodised, sliding door bolt with hasp and staple and fixing clip of sheet and fixing bolt and nut.
S&F in repair Mild steel 200 mm ordinary rat tail rod pattern springs including roller and roller plate complete fixed to wooden or steel frame all as specified and as directed.
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge.
Taking down carefully sub main wiring of any description.
Taking down defective switch fuse main board / distribution iron clad or sheet metal enclosure/ MCB DBs with MCBs of any capacity and make including wooden board etc complete all as specified and directed.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box / M S steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:- complete all as specified and directed by Engineer in charge.
(a) One light/Exh fan point controlled by one way switch
(b) One light point controlled by two Nos two way switches
(c) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(d) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 103 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge.
Supply and fix white cover plate with frame 2 Module omplete all as specified and directed by Engineer in charge.
Supply and fix white cover plate with frame 3 Module omplete all as specified and directed by Engineer in charge.
Supply and fix white cover plate with frame 4 Module omplete all as specified and directed by Engineer in charge.
M&L in replacement switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement switch modular type 6 amp SP two way, 1 module complete all as specified and directed by Engineer in charge.
M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement modular stepped type electronic fan regulator 120W, 2 module all as specified and directed by Engineer in charge.
M/L in replacement insulated body, angle holder (metal ring) with back plate complete all as specified and directed by Engineer in charge.
S&F ceiling rose PVC/Polycarbonate type with three terminals complete all as specified and directed by Engineer in charge .
M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 20Amps complete with one single pole MCB 'C' series 10/20 A capacity complete all as specified and directed by Engineer in charge.
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S&F in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge .
STRATO 2x2 Ultra Slim recess mounted EdgeLit LED module with high brightness LED package and unique pattern acrylic de-glaring diffuser sheet for glare free uniform light distrubution suitable for armstrong/grid ceiling.pannel light.
Supply and Fixing LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge .
Supply and Fixing LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge.
Supply and fix MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix in repair MCB DP 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge.
Supply and fix in repair MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge.
Supply and fixing Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
Supply and fixing Exhaust fan 400 mm sweep (steel Body) , 1250 RPM, metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
Supply and fix wall mounted fan 400mm, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system all as specified and directed.
Supply and fix in repair MCCB 125 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
Supply & fix in repair factory made epoxy powder coated Load line Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 32 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623.
M&L earthing complete with GI electrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earth plate not less than 1.50 mtr below normal ground level connected to GI strip 32x6mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of sixe 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 40 mm GI tubing light grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MS angle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia Med grade GI pipe for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed.
S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories consiled in wall /surface of walls complete all as specified and directed.
Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduitconduit accessories consiled in wall /surface of walls complete all as specified and directed.
M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M&L in replacement copper cable flexible 2 core PVC insulated of size 23/.0076 ll length of each roll is not less than 90 mtr as specified and directed by Engr-in-Charge.
Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed.
Supply only replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed.
Taking down old unserviceable down rod and supply and fix 1.5 mtr long down rod duly made out off Mild steel including taking down & refixing of existing ceiling fan of any sweep and make and making connection from ceiling rose to PVC connector complete all as specified and directed.
Supply only replacement of capacitor 2.5 Mfd, 240 V complete all as specified and directed.
S&F 45W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 110lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<10%, High and low protection along with a surge protection of 4 KV including provision of suitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed.
Taking down ceilling fan any typpe & size for opening up the winding of ceiling fan 1200/1400 mm sweep any make any type and rewinding with super enamelled copper winding wire after inserting super enamelled insulating material binding it with insulating tape etc completely and varnishing well including drying completely. Replacement of worn out / unserviceable capacitor bearing , bush , safety pins, nuts, bolts, washers , rubber bush with ceiling fan clamp, cable PVC flexible 23/0076 and testing the ceiling fan after re-fixing of the blades to the entire satisfaction of Engineer-in-Charge.
Supply only hole fastner madeup of MS 6" long with complete nut bolt all as specified.
Schedule of Credit
M/s SAAR ENGINEERS
a.k constructions
GAUTAM ELECTRIC WORKS
POONAM ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .