Chief Engineer
HQ CHIEF ENGR BHOPAL ZONE, MES SI LINE BHOPAL 462001
CONVERSION OF WATER PIPELINE FROM CI TO DI AT BAIRAGARH UNDER GE BHOPAL
2026_MES_794294_1
CEBZ/BPL/TOKEN/16 OF 2026-27
Open Tender
Civil Works
Item Rate
480 days
Bhopal
As per NIT Documents
6 documents required · 6 mandatory
₹2,000
GE Bhopal
₹5.1 L
Bhopal
16 Oct 2026
16 Oct 2026
16 Nov 2026
16 Oct 2026
14 Nov 2026
7 Nov 2026
24 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth for foundation etc or for manholes, laying of pipe lines, cables, pipes etc in any type of soft soil/water soaked soil and getting out complete all as specified and directed.
Note:-
(i) If excavation is carried out with mechanically or by JCB etc then damaged to the existing assets i.e. Sewage Lines/Electrical cables/Drains/Signal Cables/OFC Cables etc shall be repaired by contractor at his own cost. Damages shall be intimated through telephonically/Whats app msg and through mail and hence it is mandotary to contractor to provide one Mobile No/Whats app no and email Id before commencement of the work. If contractor failed to repair the damages then its repairing cost shall be recovered from his RAR/Bills.
Contd...../- | 9,046 | Cum | - | - |
| 2.01 | (ii) Dewatering of any type of water i.e. muddy water/sewage water/potable water etc from trenches before laying of CI/ DI/GI pipe and after laying of CI/ DI/ GI pipe is included in the item rate and hence arrangement of flushing of DI/CI/GI pipe is included in the item rate. Required T&P shall be provided by the contractor.
(v) Excavated material shall not be spread over /in side the Sewage chmaber and if it is spread over inside/above the sewage chamber contractor will make arrangement for removal to the same on his own arranagement and cost.
(vi) Laying of pipes shall be carried out following sequence to avoid minimum shut down and make alternate arranagement of water supply system for 3 EME Center :-
(a) Main Filter Pump House to PANAMA OHT interconnection Line 250mm dia
(b) Panama OHT to BM Map accn Line- 200mm Dia
(c) 21 CGSR to MH Bhopal main line -150mm dia
(d) MH BHopal to MES Colony - 200mm dia | - | - | - | - |
| 3 | All as per item no 2.00 but for muddy soil complete all as specified | 1,005 | Cum | - | - |
| 4 | Returning filling in, including spreading, leveling watering & well ramming in layers not exc 25 cm thick complete all as specified and directed. | 8,679 | Cum | - | - |
| 5 | Removing excavated material to a distance not exc 50 mtr & depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and diected. | 410 | Cum | - | - |
| 6Taking out existing CI/DI pipe line, of any class including CI fitting with spigot and socket ends/ flanged end and lead joint including burning out lead joints and recovering lead for reuse in new CI pipes/fittings of any class/type complete all as specified and directed of following sizes:- Note:- (i) Existing CI/DI pipes shall be dismantled on part basis and new DI pipes shall be laid imediatelly to provide uninterrupted water supply and connections of balance CI pipe shall be again reconnected with DI pipe to restore water supply. (ii) Dewatering from trenches before laying of DI pipe and after laying of pipe is included in the item rate. (iii) Flushing system shall be made at the inlet of OHT/ whereevr required i.e. Tee, flange piece 1000mm, Sluice Valve, Flange bend 90 degree etc. These items shall be paid and measured separetely. Before taking out any type of CI pipe this system shall be installed for flushing out muddy water to avoid inconvience to user. | |||||
| 7 | All as per item No 6.00 but for 80mm bore complete all as specified and directed | 200 | RM | - | - |
| 8 | All as per item No 6.00 but for 100mm bore complete all as specified and directed | 2,256 | RM | - | - |
| 9 | All as per item No 6.00 but for 150mm bore complete all as specified and directed | 6,548 | RM | - | - |
| 10 | All as per item No 6.00 but for 200mm bore complete all as specified and directed | 340 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
TEnder.pdf
Tender Documents • 1.36 MB
BOQ_890863.xls
BOQ • 5.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .