EXECUTIVE ENGINEER, DWSS, DIV.NO.1, PATIALA
EXECUTIVE ENGINEER, WATER SUPPLY AND SANITATION DIV.NO.1, PATIALA
Providing Improved Access to Water through Household connections in existing Water Supply Scheme Kaidupur of Block-Nabha, Distt Patiala under sub-component 2a (i) / JJM of Punjab Rural Water Supply and Sanitation Sector Improvement Project
2021_WSS_80451_1
E-TENDER-10/WSSD/DIV.NO.1 PATIALA/EE/2021-22
Open Tender
Civil Works
Item Rate
60 days
Village Kaidupur Block Nabha District Patiala
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹21,202
26 Apr 2022
27 Dec 2021
7 Jan 2022
27 Dec 2021
6 Jan 2022
27 Dec 2021
Amount
Component -1
Repair of Pumping Machinery complete in all respects.
Repair of Panel Board complete in all respects.
Repair of Pump Chamber
White washing (two coat)
Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint.
Distempering with dry distemper of approved manufacture one coat on old distempered work
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Finishing walls with cement based water soluble exterior paint such as snowcem, robbiacem etc. two or more coats to give an even shade
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.
Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area
Dismantling cement conglomerate floors 25mm to 50mm thick including concrete base.
Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material
Conglomerate floor 50mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material
Providing & fixing Single air valve ISI Marked as per IS-14845 including jointing , cost of nut bolts & rubber insertion all carriages complete.
C.I Single air valve screwed (Size 40mm)
Repair of Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position.
panelled, glazed or glazed and panelled.
40mm thick Door
Repair of Hollock wood cup board shutter with plywood panels or faced on both side fixed in position (excluding the cost of handles, bolts hasp with staple but including the labour for fixing them)
30mm thick Cup Board
Repair of Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
Top opening slab
P/F Pit cover
P/F Electric Fan & Tube set ISI Marked equivalent to Crompton
Repair of OHSR
One No. RCC OHSR 150000 ltrs capacity having height 28.00 mtr up to FSL and 23.50 m upto bottom slab has been already exists at site. The Repair of OHSR has been taken in this estimate.
Painting of C.I Pipes and Specials complete in all respects
Repair of expansion joint
Relacement of CI Sluice valve
P/F Main Hole cover of OHSR
Repair of plinth protection around OHSR with masonry toe wall & inside earth filling with lead 5 kms. complete in all respect as per drawing D-9 & Analysis of Rates A-10-1 to A-10-6 complete in all respects.
OHSR-150,000 ltr Capacity outer dia of toe wall = 8.96 m
Cleaning of OHSR from inside with soidum hyprochloride complete in all respect.
P/F MS Jali on top of OHSR ventilator
Repair of leakage of OHSR bottom and wall complete in all respect.
Development of Water Works
Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6 & 8 (as per Analysis A-6)
Construction of foot paths with precast kerb & earth filling & concrete topping; inside water works as per standard drawing D-10 & Analysis of Rates A-11 complete in all respects.
Repair of masonry Corner pillar including cost of cement pointing as per standard drawing D-3 & Analysis of Rates A-5 complete in all respects.
Repair of masonry Corner pillar including cost of cement pointing complete in all respects.
Providing & fixing angle iron pickets with angle 40mm x 40mm x 6mm including cost of concrete & painting complete in all respects as per standard Drawing.
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing D-7 & Analysis A-7
Providing, installing, testing & commissioning of one No. Electronically actuated, Diaphragm Operated, Metering system, Chemical Doshing Chlorinator, suitabel for delivering 0.5 to 6 Liters of Bleaching Powder Solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 kg.cm2, and suction lift not less then 1.5, as per DWSS standard specifications.
Repair and Removing of leakage in existing pipe lines including earth work, bailing out water and with material such as PVC Pipe, Tee, Bend & CI D-joints complete in all respects.
Supplying,fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects.
Provision for imporovement of Existing Water Connections complete in all respects.
Component -2
Providing proposed water connection to house hold up to wall with providing, laying jointing, testing MDPE pipe lines 15mm i/d=2.00 mtr & G.I. Pipe lines 15mm i/d = 2.50 mtr including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3" i/d clamp with C.I. bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b) complete (On Existing Pipeline)
Component -3
Providing & fixing PVC Pipes & Specials 6Kg / cm2 including cost of earth work in excavation & back filing complete.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).
Class PN-1 as per ISI
80mm i/d Sluice Valves flanged
150mm i/d Sluice Valves flanged
Construction of Brick masonry SV Chamber size 0.60x0.60 m complete in all respects.
Dismantling of cement concrete 80mm thick cement concrete 1:2:4 over 100mm thick C.C. 1:8:16 and making good the same to its original condition complete in all respects.
Dismantling of matalled road with Bithminous course 50 ti 75 mm thick with base course complete in all respects.
Providing proposed water connection to house hold up to wall with providing, laying jointing, testing MDPE pipe lines 15mm i/d=2.00 mtr & G.I. Pipe lines 15mm i/d = 2.50 mtr including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3" i/d clamp with C.I. bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b) complete (On Proposed Pipeline)
Providing and Fixing of New sign board as per DWSS Specifications.
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .