Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 CrAccepted-AOC FLAT NO S 2 SHRI CHINTAMANI S NO 1 1148 MAHAJAN PETH MODEL COLONY SHIVAJI NAGAR PUNE 411016 | PUNE | PUNE | MAHARASHTRA | 411016 | ₹4.2 Cr Quoted ₹4.3 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹4.6 Cr+₹31.7 L (7.37%)Rejected-Finance 5 KEDAR APARTMENTS 484 60 PARVATI MITRAMANDAL COLONY PARATI PUNE 411 009 | PUNE | PUNE | MAHARASHTRA | 411009 | ₹4.6 Cr+₹31.7 L (7.37%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹4.9 Cr+₹60.3 L (14.0%)Rejected-Finance | ₹4.9 Cr+₹60.3 L (14.0%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹5.0 Cr+₹74.9 L (17.4%)Rejected-Finance MATERE HOUSE SEC NO 14 PRADHIKARAN PUNE MAHARASHTRA INDIA 412105 | PUNE | MAHARASHTRA | 412105 | ₹5.0 Cr+₹74.9 L (17.4%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹5.1 Cr+₹79.1 L (18.4%)Rejected-Finance | ₹5.1 Cr+₹79.1 L (18.4%) | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹6.1 L
Closing Date
12 Dec 2020, 6:00 pmClosed
CHIEF ENGINNER PUNE ZONE
CHIEF ENGINNER PUNE ZONE DAKSHAIN KAMAN MARG CAMP-411001
ADDL ALTN AND SPECIAL REPAIR TO JCOs OR MD ACCN AT CME KIRKEE
2020_MES_385789_1
84453E8
Open Tender
Civil Works
Item Rate
455 days
KIRKEE
Please refer Tender documents.
6 documents required · 6 mandatory
₹3,000
GE CME KIRKEE
₹6.1 L
Yes
3 Feb 2021
13 Oct 2020
14 Dec 2020
13 Oct 2020
12 Dec 2020
30 Nov 2020
14 Oct 2020 - 22 Oct 2020
Amount
Note: This is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
Dismantling of single layer Mangalore Pattern roof tile laid dry complete all as specified and directed
Dismantling of single layer Mangalore Pattern roof tile bedded in lime or cement mortar complete all, as specified and directed.
Dismantling battens for tiles, shingles etc, of any size including tilting fillets spacing exceeding 15 cm complete all as specified and directed.
Supply and fixing Framed work such as roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe-410-W(Gde E-250) Quality A complete all as specified and directed.,
Supply and fixing rolled sections as in main and cross beams, hips and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc Fe-410-W (Gde E-250) Quality A complete all as specified and directed.
Preparation new or previously untreated surface of steel of any description, not exceeding 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and directed
Supply and fixing 0.63mm thick galvanised, corrugated mild steel sheeting with two corrugations side laps, fixed with 'L' hook or 'J' hook bolts and washer in roofs walls etc with grade of zinc coating 275 complete all as specified and directed.
Supply and fixing 0.63mm thick plain galvanised mild steel sheeting in ridges, hips, valley, gutters, drips and straight flashings(length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
Material and labour for roof tiles, Mangalore Pattern, interlocking at side joints laid dry complete all as specified and directed.
Labour only for laying/fixing of roof tiles, Mangalore Pattern, interlocking at side joints laid dry complete all as specified and directed. (MP tiles retrieved from dismantling to be reused)
Material and labour for ridge tiles, Mangalore Pattern of roof tiles, set and jointed in cement mortar 1:6 complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation boards /slabs /blankets, any thickness, including cover fillets all as specified and directed
Dismantling timber fillets in framed work , rails, posts, rafters, purlins, etc under 40 sqcm in section complete all as specified and directed.
Dismantling timber scantling 40 sqcm and over in section in any position in framed work complete
Material and labour for SG Gyproc T-Grid false ceiling system with 12mm thick Panel laminated with PVC film on face side and metalised polyster film on the back with all four edges sealed with PVC film ceiling tiles including all necessary auxiliaries and fixing arrangements as per manufacture instructions in the grid size 600x600 mm with consisting of Main Tee on wall of size 38mm x 24 x 0.3mm, Cross Tee of size 25mm 24mm x 0.3mm, wall angle of size 20mm x 14mm x 0.4mm using purpose made members interlocking to each other and with level clips and making holes etc all as specified and directed. Make - Gyproc (Gyprex), Armstrong & Equivalent as approved by GE.
Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Disconnecting of existing water storage tanks of capacity exceeding 500 Ltrs but not exceeding 1000 Ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Note- Cleaning repairing, etc. shall be measured separately)
S&F in repairs 20mm dia of ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipes or brass ferrule and fixed complete all as specified and as directed.
Removing of old water proofing treatment and cleaning the surface of slab and cleaning with wire brushes, removing dust, foreign material, rubbish off the site to a distance not exceeding 100m complete all as specified and directed.
M&L for 10 mm thick rendering in cement mortar 1:3 on RCC roof slabs mixed with water proofing compound @ 3% (by weight) mixed with cement or as per manufacturers instruction and finishing the surfaces even and smooth to receive water proofing treatment complete all as specified and directed by Engineer-in-Charge. Note : WPC shall be measured and paid separately.
Supply only integral water proofing compound ISI marked all as specified.
Material and labour for PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate for filleting and benching slightly rounded or chamfered on edges all as specified and as directed.
M & L for preparing roof surfaces and carrying out water proofing treatment to RCC roof slab by applying one coat of oil based bituminious primer @ 0.30 lit/Sqm and laying 3 mm thick APP polymer modified membrane weighing not less than 3.6 kg/Sqm reinforced with non woven polyster weighing not less than 160 gm/sqm with thermal insulation and finally applying two coats of solar reflective bituminous aluminium paint including removal of existing treatment, plaster etc complete and removing rubbish upto distance exceeding 50m and not exceeding 250m all as specified and as directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises, complete all as specified and directed.
Demolition cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), complete all as specified and directed.
M&L for 75mm thick cement concrete (1:3:6) type C-1, using 20mm graded stone aggregate as in plinth protection, finishing cement concrete surfaces even and smooth without using extra cement, Joints of plinth protection shall be filled with bitumen mastic (1:3) including necessary form work, complete all as specified and as directed.
M& L for 25mm thick PCC 1:2:4, (type B-0), using 12.5mm graded coarse stone aggregates as in floor, finished fair and even without using extra cement complete all as specified and as directed.
Dismantling Plain or Corrugated Steel Sheeting of any gauge or similar pattern Roof Coverings complete all as specified and directed.
M&L for sunken flooring as per following details complete all as specified and directed (a) Special treatment to toilet floor by demolition of existing treatment of any description and thickness, removal of rubbish to a distance of 5KM to 7.5KM .(b) Clean the sunken portion of toilet / Bath / WC / Kitchen thoroughly to remove laitance, dirt dust, etc.(c) Form angle fillet of size 40mm x 40mm along the junction of wall and floor using polymer modified mortar ("Dr Fixit" Pidicrete URP" or equivalent as given in Appx 'C'.) (d) Sanitary pipes entering through walls and floor shall be sealed with "Dr Fixit Bathseal Tape"or equivalent as given in Appx 'C' and the gaps to be grouted with non-shrink cementitous grout "Dr Fixit Bathseal Grout" or equivalent as given in Appx 'C'. Nahani Traps, etc to be fitted securely and the gaps around it to be grouted in the same manner. (e) Apply one coat of a Bitumen-modified polymer coating "Dr Fixit Bathseal Plus" or equivalent as given in Appx 'C' on all angle fillets by brush and cover it with 100mm open woven mesh when it is still wet. Apply second coat of the same coating on the angle fillets and allow it to dry completely.(f) In the remaining area, in dry sustrate condition brush apply first coat of the same coating and further apply second coat when first coat is dry. Extend the coating upto 150mm above the FFL. Above FFL, another cementitious waterproofing coating "Dr FixitPidifin 2K" or equivalent as given in Appx 'C' can be further applied right upto 2.10 mm to water proof the shower area also, it is a bathroom or bath cubicles of a sanitary annes and apply second coat after 6-8 hours and allow to dry completely. (g) After 2 to 3 days, sunken portion must be overlaid with a 50 mm thick concrete screed M-15 type B0 mixed with intergral WPC (Liquid) laid to be slope 1:60 towards outer face of wall. Provide 40mm OD UPVC pipe at the lowest point with 300mm projection beyond the outer face of the wall. Then fill up the sunken portion with lean concrete 1:5:10 type E2 etc complete all as per manufacturers instruction and direction.
M&L for 75mm thick cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing/ path and finishing the surface even and fair without using extra cement all as specified and directed.
S&F joint free non skid ceramic coloured tiles, 7 to 8mm thick grade B II matt superior finish first quality, (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc, laid over and including 15 thick screed bed in cement mortar 1:6 and set and jointed in neat cement slurry and pointed in coloured cement all as specified and as directed.
S&F joint free non skid ceramic coloured tiles, 7 to 8mm thick, (square/rectangular), area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in vertical surfaces fixed over and including 10 mm thick backing coat of cement mortar 1:4 and set and jointed in neat cement slurry and pointed in coloured cement all as specified and as directed.
S&F glazed ceramic coloured tiles over vertical surface of wall, 350x 250x 7mm/ 450x 350x 7mm thick (or nearest size), set and jointed in neat cement slurry and pointed in coloured cement to match with and including backing coat of 10mm thick in cement mortar (1:4) complete all as specified and directed.
M & L for machine cut kota stone slab flooring 20-25mm thick over and including cement screed base laid and pointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M & L for machine cut kota stone slab flooring 20-25mm thick as in riser of steps, skirting, dado and pillar, laid over and including 10mm thick cement plaster in cement mortar 1:4 as in backing coat and jointed in grey cement to match complete all as specified and directed.
S & F in repairs UPVC (SWR) junction single (single Y) equal or unequal for 110mm dia bore including jointing material complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing or removal for 15mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing or removal for 20mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing or removal for 50mm bore of pipe complete all as specified and directed.
S & F 15mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors all as specifeid and directed
S & F 20mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors all as specifeid and directed
Refixing of 15mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors all as specifeid and directed
Refixing of 20mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors all as specifeid and directed
S & F, in repairs vitreous china wash basin, white, flat back, size 630x450mm excluding taps, waste chain and plug and porcelain stopper but including cutting for and pinning in ends of brackets or errecting stand, waste coupling, waste pipe complete all as specified and directed
S & F, in repair, vitreous china squatting pan, 'Orissa’ pattern, white of size 580mm x 440mm with integral foot rest, P or S trap (excluding flushing cistern and flush pipe) including provision of cement concrete (1:5:10), type E-2, using 40mm graded stone aggregete complete all as specified and directed.
S&F, in repair, 10 litres capacity, UPVC valveless, syphonic action type, flushing cistern, low level, white, with inlet ball valve, float and handle including brackets and connection to pipe or lever etc. complete all as specified and directed.
S & F pillar taps, fancy type, cast copper alloy with capstan head, chromium plated, screwed down high pressure, with or without lettered ‘hot’ or ‘cold’ with long screwed shanks and fly nuts, screwed for iron pipes 15mm bore complete all as specified and directed.
S & F for PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F in repairs, bib taps, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule of 15mm bore complete all as specified and directed.
S&F in repairs, stop valve, fancy type, chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes or for unions of 15mm bore complete all as specified and directed.
Taking down of chowkats or frames with shutters (with out taking off shutters from the frames) not exceeding 1.5sqm each all as specified and as directed complete.
Taking down of chowkats or frames with shutters (with out taking off shutters from the frames) exceeding 1.5sqm but not exceeding 4sqm each all as specified and as directed complete.
Taking down shutter of any description exceeding 1 sqm and not exceeding 2sqm each complete and removing from site all as specified and directed complete.
S & F for pressed steel door frames of size 105x60mm and 1.25mm thick for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including filling of hollow portion with PCC 1:3:6 type C-1 using 20mm graded coarse stone aggregates complete, all as specified and directed.
S & F for pressed steel door frames of size 125x60mm and 1.25mm thick for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including filling of hollow portion with PCC 1:3:6 type C-1 using 20mm graded coarse stone aggregates complete, all as specified and directed.
M & L for preparing surfaces of wood and wood based materials and treating back of chowkats etc. area tarred exceeding 0.1 sqm but not exceeding 0.5 sqm each with tar or coal tar black paint all as specified and and as directed.
M & L for refixing of shutters of area exceeding 1Sqm but not exceeding 2 Sqm in the other opening after due repairs and fixed complete all as specified and as directed.
S & F for flush shutters 35mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides with and including 5mm thick lipping complete all as specified and as directed.
S & F for 2nd class hard wood 35 mm thick, glazed and skeleton shutters open rebated and prepared to receive glass, gauze,etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, size of members of shutters as specified in SSR Part-1, Section 8, clause 8.24 (a) complete all as specified and as directed.
S&F 35mm thick second class hard wood factory made plain framed panelled door shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board medium density with commercial veneering both face. The size of rail and stile shall be as per IS 1003 (Part-I), kiln seasoned and chemically pressure treated all as specified and directed.
M&L for preparation of new wooden surfaces of any description, not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
M & L for preparing surface of iron and treating small articles such as stop, covers, gully grating, holdfasts, end of posts area exceeding 0.1 Sqm but not exceding 0.50 Sqm each complete treated with tar or coal tar black paint all as specified and as directed.
M&L for cement concrete 1:2:4 , type B1, using 20mm graded coarse stone aggregate as in coping, bed plates,fixing of hold fasts and other similar works and the like including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified.
M & L for chromium plated, brass two way angle cock with wall flange of 15mm dia capstan head and fixed complete all as specified and as directed.
S & F 140mm floor door stopper of aluminum alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor all as specified and as directed.
S & F framed work such as grills, grating etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings and similar work conforming to Fe-290 Gd E-165 all as specified and as directed.
M & L for preparing new/untreated surfaces of steel of any description exceeding 10cm width or grith and applying two coat of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified.
S & F Solid PVC Door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed.
S&F factory made Solid PVC Moulded Door Shutter, 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing all as specified and as directed.
M&L, in repairs 18/19mm thick, Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
M&L for external teak wood lipping 18/19mm wide, 6mm thick fixed with nails complete all as specified and directed.
M&L 2nd class hard wood wrought as in scantling including dismantling timber scantling 40 sqcm and over in section in any position complete all as specified and described.
M&L for 18/19mm thick particle board, medium density, flat pressed single line layer type or three layer type with BWR type adhesive fixed with screws to timber frame including dismantling existing board complete all as specified and directed.
S & F for 150mm hasp and staple, mild steel, wire type stove enamelled black, including bolt to hinge plate and fixed with screw, complete all as specified and directed.
S & F for aluminium anodised butt hinges medium weight, cold rolled, 100mm, ISI marked, complete all as specified and directed.
S & F for aluminium anodised, barrel tower bolts of extruded section and fixed of size 200 mm, complete all as specified and directed.
S & F for Aluminium anodised, barrel tower bolts of extruded section and fixed of size 150 mm, complete all as specified and directed.
S&F 125 mm long extruded aluminium alloy handles, fabricated type anodised all as specified and as directed.
S&F 150 mm long extruded aluminium alloy handles, fabricated type anodised all as specified and as directed.
S & F for 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, all as specified and as directed.
S&F Mild steel 300mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S & F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple, complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M & L for precast solid block masonry of block 1:3:6 type C-1 wall exceeding 10 cm in width and built in cement mortar 1:6 complete all as specified and directed.
M&L 15mm thick cement plastering on concrete surfaces in cement mortar 1:4, finishing surfaces even and smooth without using extra cement complete all as specified and as directed.
S & F for ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and as directed.
M&L for rendering 15mm thick on brick/stone masonry surfaces in cement mortar 1:6 finished even and smooth with 1mm thick sagol over irregular face of walls complete all as specified and as directed.
M & L for rendering 10mm thick on brick/stone masonary surfaces in cement mortar 1:4 and further 5mm thick on cement mortar 1:4 with WPC, finished even and smooth with sagol finish on irregular face of walls complete all as specified and directed.
M & L for rendering 5mm thick on concrete surfaces in cement mortar 1:3 on ceiling, surface finished even and smooth with 1mm thick sagol complete all as specified and directed.
S&F joint free non skid ceramic coloured tiles, 7 to 8mm thick, (square/rectangular), area of each tile exceeding 0.09sqm but not exceeding 0.18 sqm in floors etc, laid over and including 15mm thick screed bed in cement mortar 1:6 and set and jointed in neat cement slurry and pointed in coloured cement all as specified and as directed.
M&L preparing newly plastered surfaces of wall including 3mm thick POP/ Birla putty over entire surfaces and applying two coats of oil bound distemper over one coat primer on walls complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceilings and applying three coat of white wash on ceilings complete all as specified and directed
M&L preparation of newly plastered or unplastered surfaces on wall surfaces and applying two coats of cement base paint complete all as specified.
M&L for complete removal of existing treatment on wall and applying two coats of Distemper oil emulsion over a coat of primer on plastered and other surfaces with alkali resistant primer over 3mm thick layer of wall care putty on wall complete all as specified and directed
M&L for complete removal of existing treatment on wall and applying two coats of white wash complete all as specified and directed
M&L for complete removal of existing treatment on wall and applying two coats of cement based paint complete all as specified and directed
M&L for complete removal of existing treatment on ceiling and applying two coats of white wash complete all as specified and directed
S & F in repairs 19/20mm dia MS pipe powder coated of approved colour as in decorative type curtain rods heavy duty complete all as specified and as directed.
S & F in repairs brackets powder coated of approved decorative type suitable for 19/20mm dia pipe including fixing screws, drilling etc complete all as specified and as directed.
M & L for providing cement concrete of type B-1 (1:2:4), using 20 mm graded stone aggregates, as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
S & F in repairs, 75 mm dia bore UPVC (SWR) pipe single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F in repairs, 110 mm dia bore UPVC (SWR) pipe single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F in repairs, UPVC (SWR) bend any radius for 75 mm bore pipe including jointing material complete all as specified and directed.
S & F in repairs, UPVC (SWR) bend any radius for 110 mm bore pipe including jointing material complete all as specified and directed.
S & F in repairs, UPVC (SWR) junction single, (Single T) equal or unequal for 75mm dia bore as specified and directed.
S & F in repairs, UPVC (SWR) junction single, (Single T) equal or unequal for 110mm dia bore as specified and directed.
M&L in repairs, 75 mm dia UPVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
S & F in repairs, 110 mm dia UPVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
S & F in repairs, UPVC (SWR) vent cowl for 75mm dia bore as specified and directed.
S & F in repairs, UPVC (SWR) vent cowl for 110mm dia bore as specified and directed.
Dismantling stone slab and tiles of any description and thickness as in floor including cement mortar bedding and removing rubbish from the premises complete all as specified and directed.
M&L 16-18mm thick Granite (of any type) as in cooking platforms and like, machine cut and mirror polished fixed with neat cement slurry and pointed in white cement with admixture of pigment to match the shade of granite stone over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
M & L for 20-25mm thick machine cut cudappah stone for steps, jambs, pillars, window cills, cooking platform and the like, laid over and including screed bed 15mm thick in cement mortar 1:4 including cutting, rubbing and polishing complete all as specified and as directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations, thickness of slab not exceeding 25mm, all as specified and as directed.
S&F stainless steel sink, made out of 1mm thick sheet for kitchen with plugs, washer and waste in repairs including in cement mortar to dwarf wall or including fixing cantilever brackets and connection union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm all as specified and as directed.
M & L in repairs for Rotational moulded polyethylene water storage tanks of capacity 750 Ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete with and including 20mm dia ball brass valve, high pressure with polythylene float and fly nut complete screwed for iron pipe or brass ferrule all as specified and as directed.
M & L for chipping off loose concrete/plaster upto sound stratum of RCC members such as slab, chajjas, columns, beams and cleaning the surfaces with wire brush, washing down with water using water jet including necessary scaffholding & propping to support the structural members where work is tobe executed and removing debries to a distance exceeding 250m but not exceeding 500m all as specified and as directed.
M & L for providing and applying rust inhibition coat system (in two coats) as per manufacturers instructions to exposed reinforcement after cleaning and removing scales and rust complete all as specified and as directed.
M & L for providing and applying bond coat (epoxy based bonding materials) to all exposed concrete surfaces all as per manufacturers instructions complete all as specified and as directed.
M & L for providing and applying latex polymer modified cement mortar in specified composition of system ( i.e. cement 400 parts by weight , quartz sand 1600 parts by weight , polymer 60 parts by weight, water 120 parts by weight) to RCC surfaces all as per manufacturers instructions complete all as specified and as directed. (Note: Thickness of plaster/filling 15mm to 25mm)
M&L for anti-termite treatment of soil under existing floors and junctions of wall & floor, using chemical emulsion @ one ltr per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 including white cementing and surface finishes to match the existing floors / walls all as complete.
M&L for post construction ATT at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.50 ltr per hole by drilling 6mm dia holes at a down ward angle of 45 degree at 150mm centre to centre and sealing the same with white cement including surface finishes to match the existing surface complete all as specified.
S&F in repair, Brass chromium plated tubular towel rail, 20mm dia , D type, 60cm long between flanges complete all as specified and directed
S&F stack clamps for 75mm bore pipe, made out of 50x5mm flat iron and 16mm dia round iron stays , including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S&F stack clamps for 110mm bore pipe, made out of 50x5mm flat iron and 16mm dia round iron stays , including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
M&L for welding in repairs of any thickness not exceeding 2.5cm in length to old doors/ any shutter of thickness exceeding 9 mm but not exceeding 20 mm for fixing hinges, tower bolt, sliding door bolt, handles, locking system, etc complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old steel surfaces of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
Dismantling of boarding, any description and in any position with nails complete, all as specified and as directed.
M&L for 2nd class hardwood clean sawn weather boarding, plain, 20mm thick or feather edged 15mm to 20mm thick and fixed with 30mm laps complete all as specified and directed.
M&L for preparing the surfaces of wood and wood based materials new or old of any description and girth not otherwise described and treating with two coats of cresote oil complete all as specified and directed
S&F in reapirs, galvanised mild steel wire cloth 0.56mm nominal dia of wire and width of aperture 1.18mm & fixed with tinned tacks or galvanised wire staples complete all as specified and as directed.
S&F in repairs, brass chromium plated shower roses 125mm size with or without swivel joints any size including fixing to steel pipe or union complete all as specified and as directed.
S&F in repair, Soap dish, vitreous China white, approximate size 160x 60x90mm, fixed to plug with CP brass screw and complete all as specififed and as directed.
S&F Stainless steel plate rack of size 31" x 24" x 10" of 0.63mm thickness stainless steel sheet, SS Screw & Round pipe, grade of steel SS-304 complete all as specified and directed.
S&F continuous (piano) hinges, mild steel, bright finish or electrogalvanised, width of flaps (When open) is 30 mm, all as specified and as directed.
S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified and directed.
S & F Mild steel Hat pegs, solid body, 125mm to 175 mm and fixed complete all as specified and as directed.
M & L for mild steel works as in bands straps, hold fasts etc, conforming to IS-2062-2006 (Fe-290), embedded portion duly painted with bituminious paint and sanded, complete all as specified.
S & F Powder coated of any colour Anodised Aluminium Frame (minimum thickness of powder coating 50 micron) for doors windows ventilarots with one or more rebates including cleat for fixing etc complete all as specified and directed.
S&F Powder coated Anodised Aluminium Frame any colour (minimum thickness of powder coating 50 micron) for window ventilators glass shutters side hung type with out sash bars aluminium sections weighing 0.55 Kg/M including necessary joining cleats glazing clips rubber packing anodised aluminium snap beading screws anodised aluminium fittings such as peg stays 150mm long (01 Nos) hinges (02 Nos) suitable handle (01 Nos) for fixing etc complete all as specified and directed
S&F Powder coated Anodised Aluminium Frame (minimum thickness of powder coating 50 micron) for window ventilators gauged shutters side hung type with out sash bars aluminium sections weighing 0.55 Kg/M including necessary joining cleats glazing clips rubber packing anodised aluminium snap beading screws anodised aluminium fittings such as peg stays 150mm long (01 Nos) hinges (02 Nos) suitable handle (01 Nos) for fixing etc complete all as specified and directed
S&F 4.80mm thick sheet glass ordinary quality and glazing fixing through glazing cleats in exc 0.5 Sqm in each paneetc complete all as specified and directed
S&F 4.80mm thick sheet glass ordinary quality and glazing if sheet glass is ground or obscured or frosted on one side fixing through glazing cleats in not exeeding 0.5 Sqm in each pane etc complete all as specified and directed
Supply and fixing powder coated Anodised aluminium XPM (grill) 4mm thick (minimum thickness of powder coating 50 micron) for windows ventilators with one or more rebates including cleat for fixing etc complete all as per drg specified and directed
M & L for 200 mm thick (compacted thickness) Granular Sub Base (GSB) of Grade I as per Table 400-I of MORT&H, IRC specification laid with mechanical paver rolled and compacted to required gradient and camber with 8 to 10 tonne power roller and vibratory roller complete as per MORT&H specification clause-401 including all tools and plant and managing diversion complete all as specified and as directed.
M&L 150mm thick hard core of broken stone of gauge not exceeding 63 mm deposited spread and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface etc complete all as directed.
M & L for factory made precast cement concrete M-20 grade blocks of approved size shape and dimension as in kerbs setting in cement mortar 1:4, complete all as specified & directed.
M&L for 60mm thick machine pressed pre-cast cement concrete interlocking paver blocks with grey cement and pigment, rubber moulded any shape and size confirming to IS 15658-2006, M-35 grade as in floor/pavement laid over and including 25mm thick crushed stone sand complete all as specified and as directed.
M&L for precast RCC M-20 grade as in landings, cover slabs for drains, chulla hoods, chajjas, water troughs, shelves and similar atricles with plain faces etc complete all as specified & directed .
M & L for TMT bars 5mm dia and over and upto 10mm as in reinforcement cut to length, bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less then 0.9 mm dia.etc complete all as specified & directed .
Surface excavation not exceeding 30cm depth and averaging 15cm depth and getting out in hard/dense soil all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding. 1.5 m in depth for foundation etc or for shafts, wells, manholes, pier holes, laying of cable & pipes etc not exceeding 10 sq m on plan not exceeding 1.5m in depth and getting out in soft/loose soil.
Excavation in trenches not exceeding 1.5 m wide and not exceeding. 1.5 m in depth for foundation etc or for shafts, wells, manholes, pier holes, laying of cable & pipes etc not exceeding 10 sq m on plan not exceeding 1.5m in depth and getting out in hard/dense soil.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick as in soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m from the starting point complete all as specified & directed.
Supply, laying in trenches and jointing Galvanised steel water tubings, medium grade, ISI Marked conforming to IS-1239, in any lengths with screwed and socket joints, together with and including galvanised steel fittings such as sockets, elbows, bends, tees reducers, unions caps plugs, nipples, short pieces etc for 20mm dia bore pipes all as specified and directed.
Supply, laying in trenches and jointing Galvanised steel water tubings, medium grade, ISI Marked conforming to IS-1239, in any lengths with screwed and socket joints, together with and including galvanised steel fittings such as sockets, elbows, bends, tees reducers, unions caps plugs, nipples, short pieces etc for 25mm dia bore pipes all as specified and directed.
Supply, laying in trenches and jointing Galvanised steel water tubings, medium grade, ISI Marked conforming to IS-1239, in any lengths with screwed and socket joints, together with and including galvanised steel fittings such as sockets, elbows, bends, tees reducers, unions caps plugs, nipples, short pieces etc for 40mm dia bore pipes all as specified and directed.
Supply, laying in trenches and jointing Galvanised steel water tubings, medium grade, ISI Marked conforming to IS-1239, in any lengths with screwed and socket joints, together with and including galvanised steel fittings such as sockets, elbows, bends, tees reducers, unions caps plugs, nipples, short pieces etc for 50mm dia bore pipes all as specified and directed.
Supply and fix Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for size of 20mm dia bore ISI marked, complete all as specified and directed.
Supply and fix Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for size of 40mm dia bore ISI marked, complete all as specified and directed.
Supply and fix Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for size of 50mm dia bore ISI marked, complete all as specified and directed.
S&F bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule of 15mm bore complete all as specified and directed.
M & L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth in brick/ concrete surfaces all as specified and as directed.
Taking out old UG cable from trenches/wall/floor/pole of size 25 sqmm 3.5 core aluminium (Excavation work will be paid seperately).
Taking out old UG cable from trenches/wall/floor/pole of size 35 sqmm 3.5 core aluminium (Excavation work will be paid seperately).
Supply, laying, testing and commissionnig of UG LT cables 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminum conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/MDB in building etc to suit the cable including material and labour for all jointing/connecting material as required size, cables laid in trenches /ducts /under plinth floors passing through pipes etc, fixed on wall of size 3.5core 35 Sqmm complete all as specified and as directed.
S&F Reinforced cement concrete (Hume) pipe of bore dia 80 mm , class NP2, laid and jointed with collar in cement mortar 1:4 complete all as specified and directed.
Supply and laying GI tubing light grade of size 50 mm dia bore for encasing cables for mechanical proctection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor or along poles or as street light poles or as mounting bracket with complete accessories such as bends /sockets /reducers /saddles including necessary threading/drilling works all as specified and directed.
M & L for cutting road/path/floor of width 45cm and depth 50cm for laying GI pipe medium grade for UG cable and making good with PCC 1:2:4 type B-1 using 20mm graded coarse stone aggregates all as specified and directed.
Taking down carefully existing unserviceable aluminium point wiring (light, fan, sockets or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials from site and making good disturbed surfaces of walls, floors, ceilings all as specified and as directed.
Taking down old ceiling fans of any type/sweep 230 V AC by disconnecting from the existing electric connections carefully without causing any damage to fans, removal of external dirt & painting of fan including blades complete by way of degreasing old paint and painting with one coat of primer and two coats of white enamel gloss paint without causing any damage and marking of MES No on it and refixing the fans at the same locations complete all as specified and as directed.
M&L for point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated and unsheathed, FRLS cable 1100 volt grade ISI -694 marked, drawn through in and including heavy duty, PVC non metalic rigid conduits 20mm dia or higher dia as required at site, totally concealed in walls/ floor/ceiling and surfaces on trusses by means of saddles & clips etc including all conduit accessories/fittings/junction boxes/inspection covers etc of heavy grade, ISI marked and sunk terminal boxes of factory made 16 guage (1.588mm) pressed steel housing totally concealed in walls with 3mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk/cup wahsers, for mounting of switches, socket, fan regulators etc. including PVC insulated multistranded copper conductor 1.50 sqmm (nominal area) single core FRLS cable as continuous earthwire connected to metallic bodies of luminaires/fans etc. at one end and to common earth dolly at other end all as specified and as directed for one light/fan point controlled by one, one way switch 5 Amp.
M&L for point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated and unsheathed, FRLS cable 1100 volt grade ISI -694 marked, drawn through in and including heavy duty, PVC non metalic rigid conduits 20mm dia or higher dia as required at site, totally concealed in walls/ floor/ceiling and surfaces on trusses by means of saddles & clips etc including all conduit accessories/fittings/junction boxes/inspection covers etc of heavy grade, ISI marked and sunk terminal boxes of factory made 16 guage (1.588mm) pressed steel housing, totally concealed in walls with 3mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk/cup wahsers, for mounting of switches, socket, fan regulators etc., including PVC insulated multistranded copper conductor 1.50 sqmm (nominal area) single core FRLS cable as continuous earthwire connected to metallic bodies of luminaires/fans etc. at one end and to common earth dolly at other end all as specified and as directed for one 3/5 pin socket out let 5Amps on the same board with other switches .
M&L for point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated and unsheathed, FRLS cable 1100 volt grade ISI -694 marked, drawn through in and including heavy duty, PVC non metalic rigid conduits 20mm dia or higher dia as required at site, totally concealed in walls/ floor/ceiling and surfaces on trusses by means of saddles & clips etc including all conduit accessories/fittings/junction boxes/inspection covers etc of heavy grade, ISI marked and sunk terminal boxes of factory made 16 guage (1.588mm) pressed steel housing, totally concealed in walls with 3mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk/cup wahsers, for mounting of switches, socket, fan regulators etc., including PVC insulated multistranded copper conductor 1.50 sqmm (nominal area) single core FRLS cable as continuous earthwire connected to metallic bodies of luminaires/fans etc. at one end and to common earth dolly at other end all as specified and as directed for one 3/5 pin socket out let 5Amps on independent board .
M&L for point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated and unsheathed, FRLS cable 1100 volt grade ISI -694 marked, drawn through in and including heavy duty, PVC non metalic rigid conduits 20mm dia or higher dia as required at site, totally concealed in walls/ floor/ceiling and surfaces on trusses by means of saddles & clips etc including all conduit accessories/fittings/junction boxes/inspection covers etc of heavy grade, ISI marked and sunk terminal boxes of factory made 16 guage (1.588mm) pressed steel housing, totally concealed in walls with 3mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk/cup wahsers, for mounting of switches, socket, fan regulators etc., including PVC insulated multistranded copper conductor 1.50 sqmm (nominal area) single core FRLS cable as continuous earthwire connected to metallic bodies of luminaires/fans etc. at one end and to common earth dolly all as specified and as directed for one bell point controlled by one bell switch 5 Amps.
M&L for point wiring using approved colour coding as per IS, with multistranded copper conductor 2.5 sqmm (nominal area), two single core, PVC insulated and unsheathed, FRLS cable 1100 volt grade ISI -694 marked, drawn through in and including heavy duty, PVC non metalic rigid conduits 20mm dia or higher dia as required at site, totally concealed in walls/ floor/ceiling and surfaces on trusses by means of saddles & clips etc including all conduit accessories/fittings/junction boxes/inspection covers etc of heavy grade, ISI marked and sunk terminal boxes of factory made 16 guage (1.588mm) pressed steel housing, totally concealed in walls with 3mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk/cup wahsers, for mounting of switches, socket, fan regulators etc., including PVC insulated multistranded copper conductor 2.50 sqmm (nominal area) single core FRLS cable as continuous earthwire connected to metallic bodies of luminaires/fans etc. at one end and to common earth dollyall as specified and as directed for one 3 pin socket out let 15Amps on independent board .
S&F ceiling rose surface backalite three terminal, 50 mm dia PVC/polycorbonate insulated body including PVC mounting block white/ ivory /urea finish complete all as specified and directed.
S&F switch piano flush type polycorbonate 5 Amps single pole one way, 230 volts all as specified and as direcrted
S&F socket outlet polycorbonate 5 Amps, 2 in 1 , 3 pin 5Amps flush type all as specified and as direcrted
S&F socket outlet, 2 in 1, 5 and 15 Amps multipurpose flush type complete all as specified and as direcrted
S&F switch piano flush type polycorbonate 15/16 Amps single pole one way, 230 volts all as specified and as direcrted
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc 120 W, step type concealed inside the terminated switch board/box with operating knob protruding out , flush, suitable for operation on 230Volts, 50Hz AC supply complete all as specified and directed.
S&F switch bell push 5 Amps flush type, one way, 230 volts all as specified and as direcrted
S&F Bell, ding dong type suitable for AC 230 volts,50 Hz, single pole complete all as specified and directed.
S & F lamp holder, PVC/Polycorbonate type with back plate suitable for batten/angular fittings with and including one LED lamp 20 watt pin type all as specified and as directed.
S & F wall mounted LED 20 watt, LED batten for surface and pendent application, anodised extruded aluminium housing, high transmissivity diffuser and high lumen output, 230 Volts etc complete all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23.0.193 from ceiling rose to fitting complete all as specified and as directed. Bajaj Cat No BCLAB 20W or equivalent in makes as per Appendix 'C'.
S & F wall mounted LED 10 watt, LED batten for surface and pendent application, anodised extruded aluminium housing, high transmissivity diffuser and high lumen output, 230 Volts etc complete all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23.0.193 from ceiling rose to fitting complete all as specified and as directed. Bajaj Cat No BCLAB 20W or equivalent in makes as per Appendix 'C'.
S & F building security light luminaire LED type fitting 30 Watt pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 suitable for 230 volts 50Hz single phase AC supply including suitable size GI bracket fabricated out of GI tubing light grade 25mm bore bend to the shape as directed and of length not less than 1m complete with mounting MS clamp of flat iron size 40x5mm of suitable length 02 pairs including nut and bolts etc of suitable size and including taking down old unserviceable light fitting of any type all as specified and as directed.
S&F in repairs pre wired distribution board sheet metal enclosure double door, factory made with IP43 grade protection fixed flush with wall inside the nitches for mounting MCBs, 230 Volts with bus bars with front openable cover Single pole and neutral 8 way with Copper bus bar of suitable size 100A consumer unit & prewired complete all as specified and as directed.
S&F in repairs MCB Single pole and neutral 240 volts 32/40 Amps 10 KA, type B complete all as specified and directed. Make as given in Appendix 'C'.
S&F in reapirs MCB Single pole 240 volts 6-32 Amps 10 KA, type B complete all as specified and directed. Make as given in Appendix 'C'.
S & F sub main wiring with approved colour coding as per IS with two single core 6Sqmm FRLSH PVC insulated, copper conductor cable 1100 Volts grade multistranded, unsheathed conductor drawn through and including one single core 6 sqmm FRLSH PVC insulated, unsheathed, multistranded, flexible copper cable as earthing lead, all as per IS 694 / 1990 drawn through & including non metalic rigid PVC conduit and conduit accessories concealed in walls/roof/floor etc all as specified and as directed. Note: Two runs of 6Sqmm, one run of 6Sqmm cable and one run of PVC conduit will be measured as one unit.
Design, supply, installing, testing and commissioning of weather dust and vermin proof LT distribution panel board factory made, outdoor type suitable size so as to accomodate the following accessories, depth not less than 500mm, IP54 and all as per IE rules, prewired and fabricated with 3.15mm thick CRCA sheet epoxy powder coated double door with aprons, duly powder coated mounted on MS 50x50x6mm angle iron frame and tee section frame complete of size 1.2mx1.0mx0.67m welded in shape with two coats of synthetic enamel paint over a coat of red oxide primer including necessary grouting in PCC 1:3:6 type C-1 using 20mm graded coarse stone aggregates complete with legs 500mm grouted in ground in PCC, and 400mm above ground, including connection cable glands, lugs etc and consisting of the following:- (Note: PCC plinth will be measured and paid seperately)
(a) Aluminium bus bar 200 A rated -04 Nos for phase and 01 No for neutral duly colour leeved mounted on epoxy insulator.
(b) MCCB 100 Amps, FP, 415V, 50Hz ICU 25 KA thermally adjustable between 70-100% and fixed magnatic release- 01 No
(c) MCB SPN 40 Amps, 230 Volts , 50 Hz, 10 KA -05 No.
(d) LED indicating lamp-03Nos (RYB)
(g) Space for mounting four temper proof electronic energy meters including gasketed sight glass 30x15x6mm thick
M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including Galvanised iron strip 25mmx 4mm as earthing lead by means of bolts, nuts & checknuts and washers etc; including GI pipe 40mm dia medium grade pipe for protection of G.I earth strip, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to earth test point, GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including concrete pit in PCC (1:3:6) type C-1 , RCC 1: 2 : 4 type B-1 earth pit with cover slab of size 450x450x50mm reinforced with 8mm TMT @ 100 centre to centre both ways including one handle for lifting made of 8mm dia MS bar, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion.
Supply and install water heater vertical/horizontal (as per site requirement) storage type electric (Geyser) of 25 Ltr capacity closed and vertical/horizontal type suitable for AC single phase 240 volt 50 Hz complete with feroglass technology, heating element incoloy glass coated with digital thermostat & cutout, heavy duty anode rod , PUF insulation, 8 bar pressure 5 star rating (latest date rating ), digital LED indicator of warranty period 7 years or more including making all connection and mounting on 4 Nos of 150mm long 16mm dia bolts, nuts and washer grouting/fixing in the wall for fixing of geyser including C .P. pipe 12mm dia and 450mm long heavy duty with both ends PVC check nut with washer to fixed on 15mm dia GI pipe for cold & hot water and making all electrical connection with existing power point complete all as specified and directed.
S&F stop valve, chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes or for unions of 15mm bore complete all as specified and directed.
S&F brass CP mixer for mixing hot & cold water screwed down for iron pipe of size 15mm dia complete all as specified and directed.
S&F in repairs exhaust fan 250mm sweep PVC body with self opening louvers of 230V 50 Hz including all mounting accessories and connections using three core flexible copper conductor cable complete making all necessary arrangement for mounting on walls including M & L for making suitable arrangement for installing 250mm sweep exhaust fan incluing removing old fan to be deposited at store yard of AGE E/M (CME) complete all as specified and directed.
Mehta Construction Co.
Veekay Enterprises
V M MATERE INFRASTRUCTURES INDIA PVT LTD
L.K.R.TIWARI CONSTRUCTION
United Sales Corporation
nhsaluji and associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .