Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC NA | NA | NA | 121004 | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.0 L+₹55,350 (12.5%)Rejected-Finance 482 GALI NO 4 TULSI VIHAR AZAD NAGAR HISAR 125001 | HISAR | HISAR | HARYANA | 125001 | L2 | Rejected-Finance L2 |
Tender Value
₹4.0 L
EMD Value
₹8,085
Closing Date
11 Jun 2025, 5:00 pmClosed
RAVI Ladwal
ED - Rewari
Construction of new District Jail building at Phideri in Distt. Rewari (Pdg. balance E.I. ducting work)
2025_HRY_450725_1
2025E512225D 9749 4C43 8CBE 3542187C6DF5668BAR
Open Tender
Civil Works
Works
30 days
Rewari
2 documents required · 2 mandatory
₹500
₹8,085
Yes
10 Jul 2025
4 Jun 2025
12 Jun 2025
4 Jun 2025
11 Jun 2025
4 Jun 2025
Amount
[23.23.1.3]MISCELLANEOUS 1.3. Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc. at both ends (Up to length of one metre):- Size 25 mm dia [Through Rate]
[23.27.1]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 1. M.S. pedestal of size 600 mm wide , 750 mm high ,300 mm deep and bottom totally open , duly embeded in 1:2:4 cement concrete block of size 750 mm x 450 mm x 200 mm above ground level , having a base of size 900 mm x 600 mm x 250 mm below ground level. 0 0 [Through Rate]
[23.27.6]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 6. M.S. pedestal of size 1500 mm wide , 1800 mm high ,450 mm deep and bottom totally open , duly embeded in cement concrete block of size 1650 mm x 600 mm x 200 mm above ground level , having a base of size 1800 mm x 750 mm x 250 mm below ground level . 0 0 [Through Rate]
[23.7.6.4]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.4. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 40 mm dia. [Through Rate]
S/I/T/C of copper pipe size 5/8 and 1/4 with insulation Make: Met tube/Maxflow/ Mandev
S.I.T.C of UPVC hard Drain Pipe Make: Ploypack, AKG, Dplast.
Supply and erection of load line (Double door TPandN vertical Distribution board) suitable for 4 pole MCCB as incomer upto 100 amp. and TP/SP Mcbs as outgoing. The load line duly erected/fixed on existing angle iron board or on surface with necessary nuts and bolts and all labour and material required to complete the job in all respect upto the Engineer-in-Charge of the work. Vertical load line 4 way
Dismantling of Air conditioners
Re-installing of Air conditioners including gas charging
Servicing of Air conditioners
Cutting of CC / stone / tile and wall for main duct cable and providing chamber and re-filling and repair as per requirement of Engineer-in-Charge of site.
Core cutting hole in slab for cabling work
Supply and Erection of 2`x2` LED Panel 36W complete with in all respect. Make: Bajaj / Philips / Surya Roshni /Wipro
S/E of FRLS PVC insulated copper conductor flexible cable complete the job in all respect upto the Engineer-in-Charge of the work. Make: Grandlay / Havells / Polycab / R.R. Kabel / KEI 6.0 Sqmm Single core wire
S/E of FRLS PVC insulated copper conductor flexible cable complete the job in all respect upto the Engineer-in-Charge of the work. Make: Grandlay / Havells / Polycab / R.R. Kabel / KEI 10.0 Sqmm Single core wire
S/E of 4 Core 2.5sqmm copper wire ISI mark Make Grandlay / Havells / Polycab / R.R. Kabel / KEI
Virender Singh prop. Balaji electric company (BID ID -1275634)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .