| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC HOUSE NO 7 1ST BYELANE AMBIKAGIRI NAGAR RGB ROAD AMBIKAGIRI NAGAR KAMRUP METRO GUWAHATI ASSAM 781024 | KAMRUP METRO | ASSAM | 781024 | ₹1.9 Cr | L1 | Accepted-AOC financially qualified |
| 2 | L2₹2.0 Cr+₹6.0 L (3.08%)Rejected-Finance KRISHNA NAGAR MALIGAON H N 113 GUWAHATI | KAMRUP METRO | ASSAM | 781001 | ₹2.0 Cr+₹6.0 L (3.08%) | L2 | Rejected-Finance Financially disqualified |
| 3 | Rejected-Technical NHM ASSAM | - | - | Rejected-Technical Technically rejected |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically rejected |
Tender Value
₹2 Cr
EMD Value
₹3.6 L
Closing Date
3 Feb 2021, 3:00 pmClosed
Managing Director
Managing Director, APTDC Ltd. Guwahati - 05
Construction of two floors of the new building (Block-II) for accommodation of the conference/training halls along with office accommodation in the Directorate of Assam Institute of Research for Tibals and scheduled castes.
2021_WPTBC_20295_1
PTDC/Engg/2018-19/70/Pt-1
Open Tender
Civil Works
Item Rate
720 days
Khanapara, Guwahati
Please refer tender document
6 documents required · 6 mandatory
₹4,500
MD at APTDC Ltd.
₹3.6 L
Yes
19 Mar 2021
21 Jan 2021
5 Feb 2021
23 Jan 2021
3 Feb 2021
23 Jan 2021
21 Jan 2021 - 22 Jan 2021
Amount
REINFORCEMENT
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.
For third floor
For fourth floor
Extra over item 18.1.1 for each subsequent floor or part thereof above first floor level. For third floor
Extra over item 18.1.1 for each subsequent floor or part thereof above first floor level. For fourth floor
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
For third floor
For fourth floor
Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
For third floor
For fourth floor
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.
For third floor
For fourth floor
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing.
For third floor
For fourth floor
Providing form work of 12mm thick Plywood board and removal of the same in edges of slabs and breaks in floors and walls etc. of in-situ reinforced concrete works upto first floor level.
For third floor
For fourth floor
Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item
For third floor
For fourth floor
Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.
For third floor
For fourth floor
Providing scaffolding using L&T-Doka access scaffold system upto a height of 40m. supported by frames of timber H-beams, bracings including suitable couplers, pins, tower spindles and 2nd class timber plank platforms complete as specified and directed by the department.
REINFORCED CEMENT CONCRETE WORKS Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. P) Using admixture, plasticiser etc c) M25 grade concrete
For third floor
For fourth floor
Extra over item Nos. 29 (I) (B), above for each subsequent floor or part thereof above the 1st floor level.
For third floor
For fourth floor
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall. (a) In cement mortar in proportion 1:4.
For third floor
For fourth floor
Extra for brick walling for each subsequent floor or part thereof above the 1st floor level. (a) 112mm thick brick/ R.B wall
For third floor
For fourth floor
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. B) On fair side b) In cement mortar 1:4
For third floor
For fourth floor
20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick)
For third floor
For fourth floor
Extra over item no 41 to 44 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
For third floor
For fourth floor
Extra over item no 41 to 42 for interior plastering above 1st floor level for every addl floor or part thereof including curing complete as directed.
For Third floor on single coat plaster
For fourth floor on single coat plaster
Extra over item no 41 to 42 for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed
For Third floor on two coat plaster
For fourth floor on two coat plaster
VITRIFIED TILES ON FLOOR Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) i) Of size 800mmx800mm and above
For third floor
For fourth floor.
ANTISKID TILES Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. Executive range-1 (Sizes 600 mm x 300mm and above)
For third floor
For fourth floor.
18 mm thick Marble stone slab flooring of sizes 1200x1200 including treads and risers of steps, skirting, laid over 20 mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels.
For third floor
For fourth floor.
Extra for nosing in steps of red or white, fine dressed and rubbed with sand stone.
For third floor
For fourth floor.
(Cieling) Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) suspended ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 298mm c/c. Then 12.5mm thick square edge Fulltone/ Sundance/ Cratone/ Louvertone/ Textured. Gypboard panels of size 595mmx595mm (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 290mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, grill diffusers etc. cut out to be made with the frame of perimeter channel supported suitably and measured and paid separately as and where necessary). (Glass wool to be measured and paid separately). M/F Frame Work with Design Type Textured Gypboard Tiles 9.5mm thick.
For third floor
For fourth floor.
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)
For third floor
For fourth floor.
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
For third floor
For fourth floor.
Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
For third floor
For fourth floor.
Extra over item no 77 above for every subsequent coat of wall painting with Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
For third floor
For fourth floor.
Finishing wall with two coats of acrylic emulsion exterior paint of approved brand of required shade by thinning by adding water as per specification of manufacture after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department. Asian paint/Berger Paint/ICI paint/J & N paint/Nerolac
For third floor
For fourth floor.
Extra over item no.83 above for every subsequent coat of acrylic emulsion exterior coatings of Unicem 'Rakshak' brand of required shade. c) Asian paint/Berger Paint/ICI paint/J & N paint/Nerolac
For third floor
For fourth floor.
Supplying and installing uPVC- Sliding Windows made out of Lead free green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including interlock profile, glazing bead, grooving bead, brush seal, aluminum sliding track, stainless steel rollers, sealing wedge block, Espag, int handle, pop up handle, keeper, drain cap, fisher screws, packing pieces with all necessary stainlessness screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of silicon sealant from inside / outside of Dowcorning / GE or equivalent. With 5mm clear glass (a) 2 Track Sliding Window with Flyscreen using uPVC section of sizes 88mm x 50 mm x 2.4mm thick wall for frame with inbuilt flyscreen track, 37mm x 61mm x 2.4mm thick wall for glass sash, 25mm x 49mm x 2.4mm thick wall for flyscreen sash having 1.5mm thick reinforcement, Interlock: 43mm x 23mm (Glass Panel) (WINSTA KOMMERLING/ FINESTA/ ENCRAFT)
For third floor
For fourth floor.
Supplying and installing uPVC- Fixed Windows made out of Lead free green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with galvanized steel 1.5/2mm including glazing bead , grooving bead, drain cap, fisher screws, packing pieces, necessary stainless steel screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of Silicon sealant from inside / outside of dowcorning / GE or equivalent. (a) Fixed window using uPVC sections of size 58mm x 52mm x 2.4mm thick wall for frame and 58mm x 68mm having 2.4mm thick wall for glass sash having reinforcement of 1.5mm thick in both frame & sash. (WINSTA KOMMERLING/ FINESTA/ ENCRAFT)
For third floor
For fourth floor.
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. with sal wood
For third floor
For fourth floor.
Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. a) Decorative type face panel and block board core. (ii) 35 mm thick .
For third floor
For fourth floor.
Providing and fixing 1st class local wood Hollock /Bonsum/ Gamari/ Sundi lining with butt joints including fitting and fixing with countersunk screws with the frame with complete (frame work to be measured and paid separately). i).12 mm thick. a) Hollock
For third floor
For fourth floor.
Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ). a) Sliding door bolts. (i) 300mmx16mm.
For third floor
For fourth floor.
a) Sliding door bolts. (i) 250mmx16mm.
For third floor
For fourth floor.
Tower bolt 300 MM X 10 MM
For third floor
For fourth floor.
Tower bolt 250 MM X 10 MM
For third floor
For fourth floor.
Door Handle 150 mm
For third floor
For fourth floor.
Door Handle 100 mm
For third floor
For fourth floor.
Butt hinge i) 125mm x 50mm x 4mm
For third floor
For fourth floor.
Butt hinge i) 100mm x 50mm x 4mm
For third floor
For fourth floor.
Door stopper with rubber dtipper
For third floor
For fourth floor.
Providing,fitting and fixing Door closer of various type UL listed and fire rated good quality depending on the door specification.Types like single speed,Double Speed,Heavy Duty etc are available and as directed & specified by the department. A) Godrej. c) Heavy Duty Door Closer( size 180 mm x 65mm x 64mm)
For third floor
For fourth floor.
Mortice lock vertical type pin cylinder Mortise Lock Oliver/Matiz/Victoria -Godrej make
For third floor
For fourth floor.
STEEL RAILING Providing and fixing stainless steel (Grade 304) railing made hollow tubes , channels , plates etc. Including welding , grinding , buffing , polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i.e. fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc. of required size , on the top of the floor or the side of wiast slab with suitable arrangement as per approval of Engineer in-charge .(For payment only weight of stainless steel member is to be considered . No extra payment for fixing accessories such as nuts , bolts, fasteners etc. will be considered )
For third floor
For fourth floor.
ELECTRICAL
Wiring for dwrawing sub-main line with pvc insulated single core unseathed industrial (multistand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or equivalent make as approved by the deptt.) pvc conduit Berlia/AKG/Presision/Presto Plast/Polycab/MW ao equinalent make as approved by the deptt. including earth continuty in in surface recessed 20 mm dia. 20 mm thick heavy ISI marked IS:9537 part- III rigid pvc conduct wiring system.
With 2x2.5 sq.mm. Mm +earth continuity with 1x1.5 sq.mm. 20 mm dia. Thick/heavey rigid pvc IS:9537 parth-III conduit.
With 2x4 sq.mm. Mm +earth continuity with 1x2.5 sq.mm. 20 mm dia. Thick/heavey rigid pvc IS:9537 parth-III conduit.
With 2x6 sq.mm. Mm +earth continuity with 1x4 sq.mm. 25 mm dia. Thick/heavey rigid pvc IS:9537 parth-III conduit.
With 2x10 sq.mm. Mm +earth continuity with 1x6 sq.mm. 25 mm dia. Thick/heavey rigid pvc IS:9537 parth-III conduit.
Wiring to 5 a pin 6 amps plug point with 1.5 sq.m. p.v.c insulated single core unseathed industrial (multistand) cable FR conforming to IS-694:1990 with flexible ……….. ……..p.v.c. conduit wiring system. When fitted on same board of light and fan.
Wiring to 5 a pin 6 amps plug point with 1.5 sq.m. p.v.c insulated single core unseathed industrial (multistand) cable FR conforming to IS-694:1990 with flexible ……….. ……..continuty with 1.5 sq.mm cable to third pin of the plug socket etc. as required complete.
Short point up to 3.00 metre length.
Madium point up to 6.00 metre length.
Long point up to 10.00 metre length.
Wiring to 5/6 a pin 16 amps plug point with 4 sq.m. p.v.c insulated single core unseathed industrial (multistand) cable to the mark IS-9537 Part-III.......... .... Make as approved by the deptt.
Short point up to 3.00 metre length.
Madium point up to 6.00 metre length.
Long point up to 10.00 metre length.
Wiring light /fan/call bell point with 3x1.5 sq.m. p.v.c insulated single core unseathed industrial (multistand) cable FR conforming to IS-694:1990 with flexible .......... ....equivalent Make as approved by the deptt.cieling rose etc. complete.
Short point up to 3.00 metre length.
Madium point up to 6.00 metre length.
Long point up to 10.00 metre length.
Supplying including and fixing of following metal boxes for MODEL RANGE, LEGRAND (MYURIUS), ANKCHOR (VIOLA), MK (WRAPAROUND / PLUS), ABB (CHEIRON), KOLORS (KREST), SCHEIDER (VIVACE), CRAPTREE in surface recessed system complete as per directed of deptt.
1-2 module type metal
3 module type metal
4-5 module type metal
6-8 module type metal
10 module type metal
12-16 module type metal
24 module type metal
Supplying including and fixing of following front flate of suitch colour MODEL RANGE, LEGRAND (MYURIUS), ANKCHOR (VIOLA), MK (WRAPAROUND / PLUS), ABB (CHEIRON), KOLORS (KREST), SCHEIDER (VIVACE), CRAPTREE complete as per directed of deptt.
1 module
2 module
3 module
4 module
5 module
6 module
8 module
10 module
16 module
24 module
Supplying with fitting fixing of blank plate single in modular switch system MODEL RANGE, LEGRAND (MYURIUS), ANKCHOR (VIOLA), MK (WRAPAROUND / PLUS), ABB (CHEIRON), KOLORS (KREST), SCHEIDER (VIVACE), CRAPTREE in surface recessed system complete as per directed of deptt.
Supplying with fitting fixing of 100 watt electronic modular fan speed controler 4-steps 2- module type MODEL RANGE, LEGRAND (MYURIUS), ANKCHOR (VIOLA), MK (WRAPAROUND / PLUS), ABB (CHEIRON), KOLORS (KREST), SCHEIDER (VIVACE), CRAPTREE in surface recessed system complete as per directed of deptt.
Supplying including installation of socket outlet 6/16 Amp 3/5 pin combined shuttered complete MODEL RANGE, LEGRAND (MYURIUS), ANKCHOR (VIOLA), MK (WRAPAROUND / PLUS), ABB (CHEIRON), KOLORS (KREST), SCHEIDER (VIVACE), CRAPTREE in surface recessed system complete as per directed of deptt.
Supplying including installation of socket outlet 6 Amp 3 pin combined shuttered complete MODEL RANGE, LEGRAND (MYURIUS), ANKCHOR (VIOLA), MK (WRAPAROUND / PLUS), ABB (CHEIRON), KOLORS (KREST), SCHEIDER (ZENCELO), including making necessary connection as per directed of deppartment.
Supplying with fitting fixing of 16 Amp one way modular clip in switch MODEL RANGE, LEGRAND (MYLINC), ANKCHOR (ROMA), MK (WRAPAROUND / PLUS), ABB (CHEIRON), KOLORS (KREST), SCHEIDER (OPAL), PHILIPS including making necessary connection as per directed of deppartment.
Supplying with fitting fixing of 6 Amp one way modular clip in switch MODEL RANGE, LEGRAND (MYLINC), ANKCHOR (ROMA), MK (WRAPAROUND / PLUS), ABB (CHEIRON), KOLORS (KREST), SCHEIDER (OPAL), PHILIPS including making necessary connection as per directed of deppartment.
Supplying with fitting fixing of 20 Amp one way modular clip in switch MODEL RANGE, LEGRAND (MYLINC), ANKCHOR (ROMA), MK (WRAPAROUND / PLUS), ABB (CHEIRON), KOLORS (KREST), SCHEIDER (OPAL), PHILIPS, Havells including making necessary connection as per directed of deppartment.
Supplying with fitting, fixing sheet steel, phosphatised, powder painted dust & vermin proof double door …………. . …..necessary connection as approved specified and directed by the deptt.)
Schneider neo break, C&S Havels…… …as approved by the deptt.
2 Way single door
4 Way single door
Supplying with fitting, fixing sheet steel, phosphatised, powder painted dust & vermin proof double door IP-43 surface mounting SPN MCB DB…………. . …..as approved specified and directed by the deptt.)
ABB, Schneider MG, legrannd, Hager make
4 Way SPN double door
12 Way SPN double door
Supplying with fitting and fixing MCCB incorner and MCB out going sheet steel, phosphatised, powder painted dust & vermin proof double door IP-43 surface mounting vertical TPN MCB DB…………. . …..as approved specified and directed by the deptt.)
ABB, Schneider MG, legrannd, Hager make
4 Way TPN (4+12) double door
8 Way TPN (4+128 double door
Supplying with fitting and fixing single pole 10 KA 240/415V 50Hz MCB of the following capacity complete with …………. . …..as approved specified and directed by the deptt.)
C Series (Schneider MG, legrannd, Hager make)
Supplying with fitting and fixing DB 10 KA 240/415V 50Hz MCB of the following capacity complete with …………. . …..as approved specified and directed by the deptt.)
C Series (Schneider MG, legrannd, Hager make)
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz MCB of the following capacity complete with …………. . …..as approved specified and directed by the deptt.)
100/300mA sensitivity DP RCCB
Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 4P MCB without encloser of the following capacity complete with …………. . …..as approved specified and directed by the deptt.)
25 KA 415V 50Hz 4P MCB (Schneider MG, legrannd, Hager make)
Sleek channel type luminuries complete with top cover & decorative dual colour end caps and with electronic ballast with 1x36 watt fluorecent tube (crompton greaves make) Model -DJB 1314LDB50 ………………… …… ……The mother item rate)
Supplying including fitting and fixing of following A.C. ceiling fan with all accessories like down rod canopy etc. of following sweeps with making necessary connection as approved by the deptt. As required comlpete and as directed by the deptt. (without regulator).
Primeum model 1200 mm sweeps (OREINT / PSPO / make) Premiun model 1050 / 1200 mm sweeps SS-390 Deco (Havells make).
SANITARY
Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately)C) Jaquar make a) White (i) Size 530 x 370x 360 (Cat No.CNS-WHT-WS01) (inclusive of seat cover)
PVC FLUSHING CISTERN
Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately)i) Parryware make a) White (iv) Deluxe Dual Flush (Cat No.C8110)
(Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required.i) Parryware make a) White (i) New Magnum (Cat. No.C0575)
SQUATING PLATE URINAL Providing fitting and fixing vitreous china squatting plate urinal with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. i) Parryware make a) White (i) New Magnum (Cat. No. C0503
WASH BASIN Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) Wall Hang Basin (C) Jaquar Make (i) Cat. No.CNS-WHT-WB04 (550 x 400 x 198)
MIRROR Providing fitting and fixing Decorative Mirror complete as directed and specified. (A) Parryware Make (b) Size 600mm x 450mm
SOAP TRAY,SOAP DISH,LIQUID SOAP DISPENSER AND LIQUID SOAP CONTAINER Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified. (i) Jaquar Make (a) Continental (Cat.No.ACN-1331N)
Providing, fitting and fixing CP towel rail complete as directed and specified (b) Sona make (iii) Towel rail Diplomat 600mm long (Cat.No.TR-0605)
Providing, fitting and fixing Chrome Plated towel ring complete as directed and specified. (c) Agmeco Made (vi) Dolfee (Cat.No.DE-00101)
Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified. (b) Sona (ii) Rupa 40mm (HT/ FT) (Cat.No.WS-0801)
BIB COCK Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) Jaquare make
(ii) Bibcock long thread
(iii)2-Way bib cock
STOP COCK Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) Lauret Brand (a)Angular stop-cock with wall flange
PILLAR COCK Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. Jaguar make (b)Long neck with areator
Supplying fitting and fixing Telephonic Chrome Plated (C.P.) shower of approved brand as directed and specified. (Pipes will be measured and paid separately) Essco make (a) Telephone shower delux with 1m PVC tube and wall hook
For third floor
INTERAL CONCEALING Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipe (B) Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure. b) 20 mm nominal outer dia pipe
WASTE PIPE,RAIN WATER PIPE,WC PIPE Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed B) uPVC pipe with uPVC fittings ( Using uPVC high pressure pipe)
110mm diameter
75mm diameter
OUTSIDE Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed C) CPVC pipe with CPVC fittings (Using SUPREME/ PRINCE/ SFMC/ FUSION brand pipe) iii) 25mm diameter
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes 2000 Lt capacity, Sintex make
VALVE Supplying and fitting ball valve as specified and directed..a) 25 mm dia. (gun metal)
TEE, REDUCING TEE, REDUCERS Providing & fixing composite Internal seal compression fittings as per ASTM F-1282-1995 annexure for water supply e.g. tees, elbows, reducers, connectors, couplers & clamps with jointing, testing complete including cutting & making good etc. Reducer e) 3240x Reduced end
Providing & fixing KiTEC make composite Internal seal compression fittings as per ASTM F-1282-1995 annexure for water supply e.g. tees, elbows, reducers, connectors, couplers & clamps with jointing, testing complete including cutting & making good etc. Female Elbow iii) 2025 x 25 mm thread
M/S KALITA ENTERPRISE
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .