Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance GRAM AEMANPUR DISTRICT BULANDSHAHR UTTAR PRADESH | BULANDSHAHR | BULANDSHAHR | UTTAR PRADESH | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical TENDER CONDITION NOT QUALIFIED |
Tender Value
Refer Docs
EMD Value
₹50,400
Closing Date
10 Aug 2022, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, EDC, ASHA NAGAR,
SE, EDC, ASHA NAGAR,
104/EDC(H)/2022-23
2022_MVVNL_719070_1
104/EDC(H)/2022-23
Open Tender
Miscellaneous Works
Fixed-rate
180 days
HARDOI
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
A/C No. 21342643946, IFSC Code IDIB000E504
₹50,400
Yes
7 Sept 2022
3 Aug 2022
10 Aug 2022
3 Aug 2022
10 Aug 2022
3 Aug 2022
180 days
Amount
Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Hardoi to JE dumps store and from JE dump store to work site within municipal area.
33 kv XLPE cable 3x120 sq. mm
33 KV XLPE cable 3x120 Outdoor Jointing Kit
33 KV XLPE cable 3x120 Indoor Jointing Kit
33 KV jointing kit 3x120 sq mm cable straight through
33 KV line isolator 800 amp
33 kV CT/PT metering pole mounted unit
33 KV Pilpher Resistant Metering Cubical Without Cable Termination Kit.
STP 11 Mtr long
Stone Pad 300x300x75 mm
T-Off channel with clamp
Top channel 125X65MM 13.10 kg / mtr
Dropper channel H/C
11 kV Pin Insulator with pin
Clamps with nut and bolts for supporting GI Pipe
G.I. Stay Set completer 16x1800 mm
Danger Board with clamp
MS Earthing complete 20 mm Danger Board with clamp
MS channel 100x50 mm (9.6 kg/m)(4.2x2) @9.6 kg/m+3% wastage
MS angle 75x75x6MM 6.8 kg / mtr (0.5x5)@6.8 kg./m+3% wastage
Laying of 33 KV 3X120 Sq. mm XLPE cable.
Cable laying D/C in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. The two cables should be separated by a partition of single bricks (All the material required for laying will be supplied by the contractor except 33 KV XLPE cable)
Single cable laying in HDPE Pipe size 100 mm dia on bridge/Culvert/Road X-ing/on required place as per site requirement for holding/fixing of pipe and cable. (All the material required for laying will be supplied by the contractor except 33 KV XLPE cable)
Single cable laying in RCC Pipe size 200 mm dia on bridge/Culvert/Road X-ing/on required place as per site requirement for holding/fixing of pipe and cable. (All the material required for laying will be supplied by the contractor except 33 KV XLPE cable)
Single cable laying in M.S./G.I pipe size 100 mm dia on bridge/Culvert/Road X-ing/on required place as per site requirement for holding/fixing of pipe and cable. (All the material required for laying will be supplied by the contractor except 33 KV XLPE cable)
Fabrication & erection of 33 KV cable exposure type double pole with the provision of cable with fixing of necessary clamps and other accessories like 1 no. T-off channel, Pin insulator, pin Stone Pad, Dropper channel, danger board, number plate, barbed wire,2 no. channels 100x50 mm (1600mm each),1 no.MS channel 75x75x6 mm(2800mm in length) for supporting the hoisting of cable & poles. Painting of double pole with one coat of red oxide & two coats of enamel paints (ISI mark). Its grouting in ratio 1:4:8 & plinthing 300 mm above ground level(all material to be arranged by contractor except steel, pole, pin & pin isolator).as per RESPO norms.
Hoisting of 33KV 3x120 sq. mm XLPE cable on double pole with MS pipe of size 5/6" dia 3 M long including its jumpering complete with clamps, nuts and bolts(all material arranged by contractor).
Nuzzling & grouting of stay set. (All the civil material & stay set will be arranged by the contractor)
Fabrication, erection, grouting, plinthing & painting of cable stand, grouting, plinthing and painting of it’s for 33 KV 3x120 sq mm XLPE twin cable.
Chemical earthing with 1.5" dia G.I pipe minimum 10 Mtr deep and connecting with equipment by G.I Strip 50x6 mm.
Supply & fixing of cable route marker at the distance of 200 meter along the cable laying route.
High Pressure testing of 33 KV cable with D.C test Voltage to which cable shall with stand on 60 KV for a duration of 5 Min. after completion of laying/joints and terminations. Testing equipment will be arranged by the contractor.
M/S AARADHYA AND ADHYATM ASSOCIATES
Sidhi Enterprises
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .