| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹11.3 L+₹55,370 (5.16%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹11.7 L+₹98,600 (9.19%)Rejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹11.8 L+₹1.1 L (10.4%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹12.9 L+₹2.2 L (20.1%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹12.5 L
EMD Value
₹25,200
Closing Date
18 Sept 2023, 6:00 pmClosed
HQ CWE DHAR ROAD UDHAMPUR
HQ CWE DHAR ROAD UDHAMPUR, PIN - 900386, C/O 56 APO
PROVN OF LED SECURITY LIGHTS FOR NEW COMMAND HOSPITAL UNDER GE (P) CH UDHAMPUR
2023_MES_598006_2
8249/CWE/DR/E8
Open Tender
Street Lighting
Item Rate
180 days
GE (P) CH Udhampur
Class E Category b(i)
5 documents required · 5 mandatory
₹500
GE P CH UDHAMPUR
₹25,200
25 Oct 2023
19 Aug 2023
25 Sept 2023
19 Aug 2023
18 Sept 2023
4 Sept 2023
Amount
Supply and fixing LED 70 watt, IP 66 LED Street security light luminaries on existing decorative poles of suitable bracket dia comprising of die cast aluminium housing with weather proof gasket of lamp and driver compartment with 120 degree view angle, lumen output > 100 lumen/watt, lumen maintenance> 70% at 50000hrs, colour temp 5000-6500k, CRl>70, THD<15%, PF>0.95 and LM 80 test compliance. The driver must be integrated APFC with short circuit protection, reverse polarity protection against 5KV high surges and comply with IEC 61000-3, IEC-61547. The luminaries must have secondary optics with perfectly matched lens for better light control including making electrical connection specified and as directed.
Supply and fixing LED 35 watt, IP 66 LED Street security light luminaries on existing decorative poles of suitable bracket dia comprising of die cast aluminium housing with weather proof gasket of lamp and driver compartment with 120 degree view angle, lumen output > 100 lumen/watt, lumen maintenance> 70% at 50000hrs, colour temp 5000-6500k, CRl>70, THD<15%, PF>0.95 and LM 80 test compliance. The driver must be integrated APFC with short circuit protection, reverse polarity protection against 5KV high surges and comply with IEC 61000-3, IEC-61547. The luminaries must have secondary optics with perfectly matched lens for better light control including making electrical connection specified and as directed.
Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directed in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level) connected to and including galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron including PCC 1:2:4 in pit, angle iron 25x25x3mm frame work with precast RCC 1:2:4 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12 mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, wire mesh and light grade GI protection pipe 15 mm bore upto 5m length for drawing in earth lead wire, salt, charcoal, etc. Including excavation and earth work in any type of soil, removal of surplus soil to a distance not exc. 50m complete all as shown in electrical plate No 3 of MES schedule 2009 (Part-I) and connected to main control board all as specified or indicated including testing on completion.
M&L for Wiring for circuit/submain wiring alongwith earth wire with the 2x1.5 sq. mm + 1x1.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in existing surface for junction box to LED lights connection all as specified and directed.
Supply & fixing IP 54 Wall mounted/pole mounted street light panel of suitable size including MCB of rating 40 Amps TPN and contactor of rating 32 Amps TP, suitable for maximum load upto 6 KW, astronomical time switch digital display of 24 hours, FRLS internal wiring, class H insulation, extended wide band coil and in build short circuit protection complete all as specified and directed by Engineer-in-Charge. Make : Havells or equivalent in Crompton/Philips as approved by GE.
GURU KRIPA ENTERPRISES
vijay kumar gupta and co
M/S Inderjit Sharma and Co.
PROACH ASSOCIATES BUILDERS & ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .