Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Techno commercially Qualified |
| 2 | Accepted-Technical | Accepted-Technical Techno commercially Qualified |
| 3 | Accepted-Technical | Accepted-Technical Techno commercially Qualified |
| 4 | Accepted-Technical | Accepted-Technical Techno-commercially Qualified |
| 5 | Not Admitted-Fee/PreQual/Technical WARD NO 2 SIDHWARKUT 21 SAILANI KOTHI KHANDWA KOTHI DISTT KHANDWA 450554 MP | EAST NIMAR | MADHYA PRADESH | 450554 | Not Admitted-Fee/PreQual/Technical Others-Bidder has not submitted envelope by the specified due date & time in the office of Tender Inviting Authority |
Tender Value
₹19.8 L
EMD Value
₹40,000
Closing Date
20 Jan 2026, 4:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Deputy General Manager, Contract and Procurement
Admin Building, Indira Sagar Power Station, Narmada Nagar, Tehsil Punasa, Dist.Khandwa, M.P., Pincode 450119
Approach to existing TCT shed and stage of Kendriya Vidhyalaya at Indira Sagar Power Station, Narmada Nagar, Distt. Khandwa (M.P.).
2025_NHDC_891732_1
NIT No. 30/3944/2025-26 dated 29-12-2025
Open Tender
Civil Works
Percentage
90 days
Indira Sagar Power Station, Narmada Nagar
As per tender documents
3 documents required · 3 mandatory
₹590
NHDC Limited
₹40,000
Yes
18 Feb 2026
30 Dec 2025
23 Jan 2026
30 Dec 2025
20 Jan 2026
30 Dec 2025
30 Dec 2025 - 13 Jan 2026
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charg
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level :With 40mm nominal size graded stone aggregate. :M-10 Nominal (Mix-1 Cement : 3 sand : 6 graded stone aggregate ).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level With 20mm nominal size graded stone aggregate. :M-15 – Grade concrete
Centering and shuttering including strutting, propping etc. and removal of form work for : Upto plinth : Foundations, footings, bases for columns, plinth beams, curtain walls, columns below plinth.
Providing and laying in position specified grade of reinforced cement concrete (nominal / design mix with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : M-20 Grade Concrete
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . (Note:- 1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers. 3. Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”) Cold twisted bars (CTD)
Steel work in built up M.S. tubular section (round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS:277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self-drilling/ self- tapping screws complete :Gutter. (600 mm over all girth)
Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion.110 mm diameter (minimum wall thickness 2.2mm)
Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.Bend 87.5°110 mm bend (minimum wall thickness 2.2mm)
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.72 MB
30Tender3944.pdf
Tender Documents • 7.45 MB
BOQ_937291.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .