| 1 | L1₹37.4 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹42.6 L+₹5.1 L (13.7%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹43.3 L+₹5.9 L (15.7%)Rejected-Finance 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹46.4 L+₹9.0 L (24.0%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹46.5 L+₹9.0 L (24.1%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
8 Jan 2022, 6:00 pmClosed
GE EAST MATHURA
Garrison Engineer East Military Engineer Services Mathura Cantt Mathura 281001
COMPREHENSIVE MAINTENANCE AND MISC BR WORK TO JCOs ORs MD ACCN AND REPAIR MAINT OF INTERNAL ELECTRIFICATION AND OTHER E M RELATED MAINT SERVICES AT OTM ACCN IN THE AOR OF GE EAST MATHURA
2021_MES_494174_1
8200-1248/E8
Open Tender
Civil Works
Item Rate
180 days
GE EAST MATHURA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE EAST MATHURA
₹1 L
22 Jan 2022
11 Dec 2021
11 Jan 2022
11 Dec 2021
8 Jan 2022
27 Dec 2021
11 Dec 2021 - 1 Jan 2022
Amount
Demolition of reinforced concrete (cutting reinforcement as required to facilitate demolition of roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work all as specified.
Taking down Cement plaster from brick wall/ceilling etc incl racking out joint & hacking out for key and scrubbing down with water all as specified
Taking up or down 15mm bore steel tubing and connections, complete all as specified and as directed
Supplying & fixing to walls and ceiling 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed
M&L cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth of brick walls complete all as specified.
Taking up or down 20mm bore steel tubing and connections, complete all as specified and as directed
Supplying & fixing to walls and ceiling 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed
Taking up or down 25mm bore steel tubing and connections, complete all as specified and as directed
Supplying & fixing to walls and ceiling 25 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed
M&L for Precast RCC M-15 (Noninal mix) using 20mm graded stone aggregate as in cover slabs for manholes.
Demolition of brick work or stone boulder masonary built in cement mortar including all quoins arches pillars etc. but excluding ashlar facing dressed stone work and precast concrete articles.
M&L for Brick work with old size fly ash bricks straight or curved on plan to any radius in half brick thick walls in built in CM 1:4.
M&L brick work with old size fly ash bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified
M&L brick work with old size fly ash bricks curved on plan n exc 6m mean radius laid dry complete all as specified and as directed.
M&L for steel reinforcement of TMT bars (FE-500 Grade) 10 mm dia and over cut to length and bent to shape required including cranking bending spirally for hooping for columns hooking end and binding with mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips all as specified and directed.
Dismantling brick tiles any size laid bedded and pointed in any mortor.
Demolition of mud in roofs any thickness and in any position and leaping over roof terrace, including plaster removing the demolished material to a distance exc 250 m but n exc 500 m and depositing where directed at a level n exc. 1.5 m above starting point, complete all as specified and as directed.
M&L for 50mm thick PCC M-15 grade (Nominal mix) using 12.5mm graded stone aggregate as in floor finish.
M&L APP based polymeric membrane not less than 3 mm tick, weighing not less then 0.40 ltr/Sqm, reinforced with polyster non-woven fabric (weighing) not less than 150gm/sqm and upper side of membrane thermally insulated with while mineral gravel finish, uniformly embeded during manufacturing process thermally insulated shall be used. It shall be laid by toruch application. Side overlaps shall be 75 mm and the ends shall be 100 mm and all overlaps and jointed shall also be sealed by torch application. For parapets, membrane shall be taken to a height of minium 300mm and then inserted inside the parapet in a grooves. The same shall be finished by a membrane flashing over a coat of cold applied bituminous primer confiming to IS:[email protected] per Sqm complete all as specified and directed.
M&L for Cement concrete tiles 20cm x 20cm x 20mm thick, machine pressed built with grey cement and no pigment, set jointed and pointed in neat cement slurry in floors, and cut and polished over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 complete.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises.
M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified.
Ditto all as per items No 22 but on vertical surfaces over and including 10mm thick cement screed in CM 1:4 complete all as specified.
M&L for Glazed ceramic tiles on vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick backing coat of cement mortar in 1:4 complete all as specified.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar
M&L 18-20 mm thick Machine cut Machine polished kota stone slab flooring over cement screed base laid and jointed with pigment to match the shade of the slab including rubbing and polishing over and including screed bed and bedding layer of mortar 20 mm thick for laying floor finishes in CM 1:3 size of Kota stone as decided by Engr-in-charge complete.
M&L 18-20 mm thick Machine cut Machine polished kota stone slab in riser of steps, skirting, dado and pillar laid over cement screed and jointed with pigment to match the shade of the slab including rubbing and polishing over and including 10 mm thick cement plaster in cement mortar 1:3 complete all as specified and as directed.
M&L 20mm thick Granite black colour (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. over and including 15mm thick screed bed or bedding layer in cement mortar 1:4, all as specified and as directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed.
M&L rendering 15 mm thick (10mm + 5mm) plaster on brick work in CM 1:4 and surface finished even and fair by mixing liquid water proofing compound as per manufacturers instructions complete. Note :- Liquid WPC shall be measured & paid seprately under relevant item of this BOQ.
Supply only liquid water proofing compound hydroseal-W+ or eqivalent (for plaster hardening, to contol efflorescence & fungal growth) as approved by GE.
M&L for Rendering 10mm thick on brick or concrete surfaces and finishing the surfaces even & smooth in CM 1:6 complete all as specified and as directe.
M&L for rendering 10 mm thick in CM 1:3 on concrete surface in ceiling complete all as specified and as directe
M&L for preparing new plastered surfaces of walls/ceilings and applying two coats of weather proof acrylic exterior paint (100% Acrylic) with one coat of self primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
M&L for preperation of new plastered surfaces & applying two coats of oil bound distember over a coat of alkali resistant primer complete all as specified and as directed.
M&L for applying wall care putty on new/old plastered wall surface (Internal) not less than 1mm thick complete all as specified and directed by Engr-in charge
M&L for preparation of new plastered surface of ceiling and applying three coats of white wash all as specified and directed by engineer in charge.
M&L for applying two coat of oil bound distemper over a coat of wall care putty not less than 1mm thick incl complete removal of existing treatment.
M&L for preparation of old surfaces of ceiling and applying two coats of white wash complete all as specified
M&L for complete removal of existing treatment on plastered surfaces of walls/ceilings and applying two coats of weather proof acrylic exterior paint (100% Acrylic) including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
S&F in repair 110mm PVC (SWR) pipes type A single socketed, excluding fittings in any length with rubber ring joints, laid in trenches or in floors
S&F in repair 75mm PVC (SWR) pipes type A single socketed, excluding fittings in any length with rubber ring joints, laid in trenches or in floors
S&F in repair 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall incl necessary clamp etc complete all as specified.
S&F in repair 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall incl necessary clamp etc complete all as specified.
S&F in repair 110mm PVC (SWR) bends any radius complete.
S&F PVC (SWR) bends any radius with acess door 75mm bore.
S&F in repair 75mm PVC (SWR) bends any radius with acess door complete.
S&F in repair 110mm PVC (SWR) junction single, (Single T) equal or unequal with acess door complete..
S&F in repair 75mm PVC (SWR) junction single, (Single T) equal or unequal with acess door complete.
S&F in repair PVC (SWR) vent cowl complete all as specified for 110 mm bore complete.
S&F in repair 75mm PVC floor trap plain with grating including jointing with solvent cement complete.
S&F in repair 15 mm size bib taps cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipes complete.
S&F in repair 15 mm size angular cock, cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed both end for iron pipes complete.
S&F Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including setting the trap and pan in concrete and including 10 ltr capacity PVC valveless syphonic action type low level flushing cistern and 32mm dia PVC Flush pipe complete including jointing to socket of flushing rim all as specified and as directed.
S&F in repair Sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm
S&F in repair vitreous china wash hand basin white flat back size 550 x 400 mm excluding taps waste chain and plug but including bracket fixed in repair complete all as specified and directed by Engineer-in-Charge.
Supply only Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed.
S&F in repair Brass chromium plated shower rose 125 mm size and including swivel shower of PTMT any colour
Supply and fix in repair 500 liters capacity white colour triple layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete.
S&F in repair 20 mm dia Gun metal, globe or gate valves,with iron wheel head,screwed both ends for iron pipes and fixed complete.
S&F PVC connections 15mm size with PTMT nuts of length 300 mm complete.
S&F Stack clamps made out of 50mm x 5mm flat iron & 16mm round iron stays including bolts & nuts and securing ends of stays for 100mm bore pipe complete.
S&F Stack clamps made out of 50mm x 5mm flat iron & 16mm round iron stays including bolts & nuts and securing ends of stays for 75mm bore pipe complete.
Supply only 32 mm Waste fittings, brass, chromium plated for basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete.
S&F 40 mm Waste fittings, brass, chromium plated for sinks, with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete..
S&F 32 mm bore Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/ cm2 fixed complete to walls for WHB/ Urinal waste pipes complete.
S&F in repair Kitchen rack plate of stainless steel of size 75 x 60cm all as per sample kept with GE office
Supply and fix in repair Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats.
M&L for 50mm thick sand stone slab set and jointed over supports in cm (1:4) complete.
S&F in repair fancy type drapray rod 20 mm dia mild steel, chromium plated with fixing brackets, incl side brackets, complete complete all as specified.
Demolition of cement concrete n exc 15 cm thickness above ground floor all as specified.
M&L for 100 mm thick cement concrete M-7.5 grade (Nominal mix) using 40mm graded stone aggregate as in sub base complete.
M&L for sand filling under floors incl watering and consolidation complete.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade made with grey cement and pigment complete all as specified and directed.
M&L for 50 mm thick PCC M-15 grade (Nominal mix) using 20 mm graded stone aggregate as in plinth protection, finishing cement concrete surface even and smooth without using extra cement.
M&L for Chequered cement concrete tiles (with white cement and pigment) 30cm x 30cm x 25mm thick rubber moulded glossey finish, set, jointed and pointed in neat cement slurry in floors over and including 20mm screed bedding in cement mortar (1:4) complete all as specified and as directed.
Taking down Chowkhats or frames with shutter without taking off shutters from the frames not exc. 1.5 sq. m each.
Taking down Chowkhats or frames with shutter without taking off shutters from the frames exc. 1.5 sq. m but n exc 4.00 Sqm each.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick single side prelam PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet PVC sheet reinforced with M.S. square tube, supplying & fixing in opening as per specification & drawing complete all as specified.
S&F factory made Factory made solid panel pace door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing given SSR Part II 2020.
S&F 125x60 mm Pressed steel frames made out of 1.25mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., with one shop coat of red oxide primer complete, as specified, supplied and fixed all as specified and as directed.
S&F 105x60 mm Pressed steel frames made out of 1.25mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., with one shop coat of red oxide primer complete, all as specified, and as directed.
M&L for preparation of new primed surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint completed all as specified and as directed.
M&L for PCC M-15 grade (Nominal mix) using 12.5 mm graded crushed stone aggregate as in filling in door frames etc of any description and any height.
S&F 30 mm thick flush shutters , solid core construction with block board core and plywood face panels commercial type on both sides all as specified and as directed.
S&F 30mm thick IInd class Hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
Supply & fix 150 mm long aluminium handles fabricated type anodised all as specified.
Supply & Fix 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed.
Supply and fix 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified.
S&F 100 mm Butt hinges, extruded aluminium alloy, with galvanised mild steel hinge pin, anodised and fixed, type C-21.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165
Supply and fix powder coated (powder coting shall not be less than 50 microns of approved colour) aluminium grill design no DG-117, 10 mm thick complete all as specified and directed by Engineer-in-Charge. Make : M/S Deco grill or equivalent with & including F sections,
M&L for 5 mm thick sheet glass ordinary quality and glazing with aluminium beading n exc in each pane complete all as specidfied and as directed.
M&L Powder coated (powder coting shall not be less than 50 microns of approved colour) aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified
M&L for 75mm powder coated aluminium barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 140mm Floor door stopper of stainless steel body and tongue, with hard drawn steel spring.
S&F 150mm, Mild Steel ordinary rat tail rod pattern springs including roller and roller plate complete.
M&L for Providing, cement concrete M-15 grade (Nominal mix) using 12.5mm graded stone aggregate in padding in sunken slab as directing mixed with liquid water proofing compound. Note: liquid WPC shall be measured and paid separetelay under relavant item of this BOQ
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3
M&L for 10 mm thick polymer modified plaster in CM 1:4 mising the polymer in the ratio of 1:10 (1 part of polymer & 10 parts of cement) for sides and base of sunken floor portion. Note:-Make of polymer Asian Paints/Pidilite/STP/ Thermax /Sico
M&L for PCC M-5 grade (Nominal mix using 40 mm graded stone aggregate as in filling into sunken floor
M&L for 25 mm average thick PCC M-15 grade (Nominal mix) using 12.5 mm grd stone agg in floors/padding finishing the surface even and smooth with out using extra cement.
S&F MS Joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated)
M&L for Cutting holes into or through brick walls built in cement mortor superficial area n exc 150 sq cm and making good in cement mortar 1:3 or cement concrete M-15 grade (Nominal mix) using 20 mm grd stone agg as required complete all as specified and as directed.
M&L for cutting chases, pining in making good to facing where required and pointed in CM (1:3) to ends or edges of landing , steps cills, sun shade, shelves lintels etc and cutting chases for concealed water tubing etc and making good cutting exc 10cm but n exc. 20 cm girth complete all as specifiedand as directed.
Supply only of integral water proofing compound confirming to IS-2465-1075 all complete and all as specified .
M&L for providing cement concrete M-15 (Nominal mix) using 20 mm graded aggregate for platforms of water tanks on roof, as in coping, benching kerb concrete etc including weathing slightly rounded or chamfered angles and throating including necessary formwork etc all complete and all as specified .
Taking down carefully aluminum/copper point wiring (light ,fan, socket any type, power, bell etc. ) complete including fixtures & fittings (such as ceiling rose, socket, Pendent, regulator etc) and removing the material from site and making good the disturbed surfaces of walls ceiling etc complete all as directed.
Taking down carefully by Submain wiring/ service connection of any type complete all as directed by Engineer-in-Charge.
Taking down old unserviceable existing SPN / TPN DB / enclousers any size and type / any descriptions as iron sheet scrap including MCB any type / size and making good disturbed surface / wall as per existing complete all as specified and directed
Taking down existing unserviceable tube light fittings/ bulkhead fitting/ building street light fitting/ ceiling fittings of any type / make from wall/ ceiling etc all as directed.
M&L for Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed (FRLS) cable, multi-stranded, copper conductor, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia med gd)and its all accessories complete concealed in wall / roof incl cutting & chases( making good all to the disturbed surfaces as per existing) and including with modular flush metal boxes with modular cover plates & frame for mounting modular switches, sockets, regulators etc and including earth wire of PVC insulated (FRLS) copper conductor multistranded of 1.5 Sqmm size in green colour complete all as specified in current SSR Part-I & II & directed by the Engineer-in-Charge, as described below:-
One light/ fan point controlled by one way Modular switch 5 amp complete.
One 3 pin 5 Amps socket point controlled by one Modular switch on independent board.
One 3 pin 5 Amps socket point controlled by one Modular switch on independent board.
One bell point controlled by one Modular push button on independent board
All as per item No.116 but for 3 pin / 5 pin 16 Amps Modular sockets outlet with 4 Sqmm PVC insulated & unsheathed (FRLS) copper conductor cable independent complete all as specified and as directed .
Supply and Fixing Modular switch 6 Amps single pole one-way, 1 Module complete as per existing, as specified and directed by Engr- in- Charge.
Supply and Fixing Modular bell Push switch 6 Amps with indicator single pole one-way, 1 Module complete as per exiting all as specified.
Supply and Fixing Modular switch 16 Amp single pole one way,1 Module complete as per exiting all as specified.
Supply & Fixing Modular fan Regulator electronic step type 120watt , 2 Module complete as per exiting all as specified.
Supply and Fixing Modular socket 2-in-1, 5 pins 6 Amps , combined 2 Module complete as per exiting all as specified.
Supply and Fixing Modular socket 2-in-1,3 and 5 pins 6 /16 Amps, combined 2 Module complete as per exiting all as specified.
Supply and Fixing switch piano flush type 5 Amps single pole one-way, complete all as specified.
S&F socket out let 2 in 1 flush type 5 pin 5 Amp complete all as specified.
S&F socket out let 2 in 1 flush type 3 pin 5 & 15 Amp complete all as specified.
Supply and Fixing switch piano flush type 15 Amp single pole one way, all as specified.
Supply and Fixing bell push switch piano flush type 5 Amps single pole one-way, complete all as specified.
Supply and Fixing fancy ceiling rose surface bakelite 65mm x 50mm three terminals complete all as specified.
Supply and fixing fancy Lamp holder, PVC / polycarbonate type with back plate suitable for batten fittings complete all as specified.
Supply and fixing Bell Multi Music type, 230 Volts complete with connection all as specified & directed.
Supply and fixing Bell Ding dong type, 230 Volts complete with connection all as specified & directed.
Supply & Fixing Modular fan Regulator electronic step type 120watt , 2 Module complete all as specified.
M&L for Sub Main Wiring with two runs single core 4 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in suitable size of rigid non-metallic PVC conduit and its all accessories complete concealed in wall/roof with and including 4 Sqmm copper green colour earth wire all as specified and directed by Engineer-in-Charge. Note:- Two runs of 4 Sqmm single core cable, one run of 4 Sqmm earth wire & One run of PVC conduit shall be measured as one unit length.
M & L for Sub Main Wiring with two runs single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in suitable size of rigid non-metallic PVC conduit and its all accessories complete concealed in wall/roof with and including 6 Sqmm copper green colour earth wire all as specified and directed by Engineer-in-Charge. Note:- Two runs of 6 Sqmm single core cable, one run of 6 Sqmm earth wire & One run of PVC conduit shall be measured as one unit length.
M&L for Sub Main Wiring with two runs single core 4 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in suitable size of rigid non-metallic PVC conduit and its all accessories complete on wall/roof with and including 4 Sqmm copper green colour earth wire all as specified and directed by Engineer-in-Charge. Note:- Two runs of 4 Sqmm single core cable, one run of 4 Sqmm earth wire & One run of PVC conduit shall be measured as one unit length.
S&F LED post top light fitting 30W IP-65 rated completeall as specified and directed. Make: Surya Cat part No SLE PT 30W-ETPP or equivalent.
Supply & fixing indoor decorative ultra slim surface /Wall mounted T5 LED batten tube light complete fitting 1x 20 watt LED Tube fitting with polycarbonate channel housing, 140V-270 volts and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Enginee-in-Charge. Make:Havells (as per Cat Part No: LUMILINEBS20WLED 865 SPC WH) or equivalent to CG/Bajaj/Philips/ syska
Supply & fixing indoor decorative ultra slim surface /Wall mounted T5 LED batten tube light complete fitting 1x 9 watt LED Tube fitting suitable for mirror light with polycarbonate channel housing, 140V-270 volts and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Enginee-in-Charge. Make:Havells (as per Cat Part No: LUMILINEBS9WLED865 SPC W H) or equivalent to CG/Bajaj /Philips / syska
Supply & fix surface mounted bulk head LED light fitting including 10 watt LED lamp B22 base complete with all accessories and connection complete all as specified and as directed.
Supply and fix LED 9W suitable for normal holder (Base Cap B22), warm white/ cool white/natural white complete all as specified.
Supply and fix LED 7W suitable for normal holder (Base Cap B22), warm white/ cool white/natural white complete all as specified.
Supply and install of 30W LED building security light fitting with lens & driver, powder coated pressure die cast aluminium, top opening and maintainable with heat resistance toughened glass, built-in Short-Circuit Protection, Over voltage Protection and Surge Protection, IP-65 proction with luminaire efficiecy of greater than 80Lumen/Watt, Colour rendering (CRI) of ≥ 70 and co- related colour temperature (CCT) of 5700K (±500K) . The luminaire should have 10 KV surg protection, PF ≥ 0.9 and total harmonic distortion of THD ≤ 10%, voltage range of 140-280V including all connections complete all as specified. Make of fitting : Havells (as per Cat Part No : ENDURACITYLITEPLAT PLUSSL30WLED757SASYBOPC) or equivalent in Crompton Greaves/ Bajaj/Philips / C&S (meeting all the above specification).
Supply & fix in repair recess type, 36 watt LED panel light (600x600 mm) complete with fittings integrated electronic driver,energy efficient, 230 volts,co- related colour temperature (CCT) of 6500K, warm white/ cool white/natural white complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete as per existing, as specified and directed by Engr- in- Charge.
Supply & fixing indoor wall mounted fitting, brushed nickel finishfixture with opal glass diffuser, with LED retrofit bulb of capacity 09 watts all as directed at site. Make:-Havells Cat Part No. FLORETINE WL 1LS B22 SS or equivalent make in Crompton/ Philips C&S.
S&F LED Round/square recess mounted slim downlighter 9 watt, integrated electronic driver, co- related colour temperature (CCT) of 6500K, warm white/ cool white/natural white complete as per existing, as specified and directed by Engr- in- Charge.
S&F LED Round/square recess mounted slim downlighter 12 watt, integrated electronic driver, co- related colour temperature (CCT) of 6500K, warm white/ cool white/natural white complete as per existing, as specified and directed by Engr- in- Charge.
S&F LED Round/square recess mounted slim downlighter 15 watt, integrated electronic driver, co- related colour temperature (CCT) of 6500K, warm white/ cool white/natural white complete as per existing, as specified and directed by Engr- in- Charge.
M&L for building security light bracket made out of 40mm dia medium grade GI pipe of 1.2 m length bent to required shape suitable for fixing street light fitting on Steel tubular pole including two Nos clamps made out 40mm X 6mm flat with suitable nuts and bolts including two coats of aluminium paint over a coating of red oxide primer complete all as directed taking down old unserviceable bracket as scrap any size / description. Make of Pipe : JINDAL/TATA/PRAKASH
S&F MCB distribution board, SPN 8 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified.
S&F MCB distribution board, SPN 4 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified.
Supply & fixing MCB triple pole and neutral 240 volts, C series of capacity 40 to 100 Amps of breaking capacity 10 KA including connections with copper lugs of suitable size in MCB DBs all as directed.
Supply & fix MCB SPN 63 Amps,' C' series , bracking cap10KA, 240V complete all as specified and directed.
Supply & fix in replacement of MCB SPN 40 Amps,' C' series , bracking cap 10KA, 240V complete all as specified and directed.
Supply & fix in replacement of MCB SPN 6-32 Amps,' C' series , bracking cap 10KA, 240V complete all as specified and directed.
Supply & fixing in replacement of MCB SP 6 - 32 Amps, ' C' series ,bracking cap 10KA, 240V complete all as specified and directed.
Supply and fix SP enclosure with a two pin and earth plug and socket complete with SP MCB of rating 20 Amps, 240 Volts complete with all conction as directed.
Taking down the ceiling fan of any sweep carefully from its installed position, dismantling complete, cleaning all dust, applying grease for bearings, reassembling the fan and blades, painting of fans with synthetic enamel paint by spraying a single coat as per existing colour paint including filling cavities with filler, writing MES No. in paint, hanging/fixing the fan in its original position and testing on completion complete all as directed by Engineer-in-charge. Note:- The spare parts (like as bearing, capacitor, rubber wheel push, fan winding etc) required shall be measured and paid separately under relevant items as supply only.
Supply only ball / bush bearing as per existing & suitable for ceiling fan / exhaust fan complete all as specified and directed.
Supply only rubber wheel bush with GI bolt, nut and split pin complete all as specified and directed.
Supply only capacitor 2.5 to 3.5 MFD suitable for ceiling fan/exhaust fan complete all as specified and directed.
Supply only down rod 600/900 mm duly powder coated white with GI bolt, nut, rubber wheel bush and split pin, clamp etc including all accessories for fixing fan complete all as specified and directed.
All as per item No. 158 here-in-before but exhaust fans of any sweep.
Material & labour for removing the defective ceiling fan winding upto 1200mm/1400mm sweep and rewinding with super enamelled copper wire of existing gauge, applying insulation varnish, pre heating and binding with empire tubes, crimple sheet etc. as required for rewinding complete all as specified and directed by Engineer-in-charge.
Material & labour for removing the defective exhaust fan winding of size 200 to 300 mm sweep and rewinding with super enamelled copper wire of existing gauge, applying insulation varnish, soldering, pre heating and binding with empire tubes, crimple sheet etc. as required for rewinding complete all as specified and directed by Engineer-in-charge.
Material & labour for removing the defective exhaust fan winding of size 350 to 450 mm sweep and rewinding with super enamelled copper wire of existing gauge, applying insulation varnish, soldering, pre heating and binding with empire tubes, crimple sheet etc. as required for rewinding complete all as specified and directed by Engineer-in-charge.
S&F Plastic Surface mounting box 1/2 modular gang box for mounting switches, sockets, fan regulator etc complete all as directed by Engineer-in-charge.
S&F Plastic Surface mounting box 3/4 modular gang box for mounting switches, sockets, fan regulator etc complete all as directed by Engineer-in-charge.
S&F Plastic Surface mounting box 6/8 modular gang box for mounting switches, sockets, fan regulator etc complete all as directed by Engineer-in-charge.
Supply & replacement of 3 mm thick laminated mica sheet top cover suitable for switch board 3 way to 6 way including removing & re-fixing of existing switch / socket and complete connection all as directed. Note :- Replacement of unserviceable switch / socket / regulator shall be measured & Paid separately under relevent item of Sch -A
Supply & replacement of 3 mm thick laminated mica sheet top cover suitable for switch board 8 way to 12 way including removing & re-fixing of existing switch / socket and complete connection all as directed. Note :- Replacement of unserviceable switch / socket / regulator shall be measured & Paid separately under relevent item of Sch -A
M&L for Modular metal flush box 1/2 Module incl cutting & chases( making good all to the disturbed surfaces as per existing) complete all as specified and directed.
M&L for Modular metal flush box 3 Module incl cutting & chases (making good all to the disturbed surfaces as per existing) complete all as specified and directed.
M&L for Modular metal flush box 4 Module incl cutting & chases (making good all to the disturbed surfaces as per existing) complete all as specified and directed.
M&L for Modular metal flush box 6 Module incl cutting & chases (making good all to the disturbed surfaces as per existing) complete all as specified and directed.
M&L for Modular metal flush box 8 Module incl cutting & chases (making good all to the disturbed surfaces as per existing) complete all as specified and directed.
M&L for Modular metal flush box 12 Module incl cutting & chases (making good all to the disturbed surfaces as per existing) complete all as specified and directed.
M&L for modular white cover plate with frame, 1/2 module complete all as specified and directed.
M&L for modular white cover plate with frame, 3 module complete all as specified and directed.
M&L for modular white cover plate with frame, 4 module complete all as specified and directed.
M&L for modular white cover plate with frame, 6 module complete all as specified and directed.
M&L for modular white cover plate with frame, 8 module complete all as specified and directed.
M&L for modular white cover plate with frame, 12 module complete all as specified and directed.
Supply and fix exhaust fan 250 mm sweep alongwith louvers/front grill, made of sturdy engineering plastic complete, suitable to work on AC, single phase, 230 Volts, 50 Hz supply and including connecting up with twin core twisted flexible copper conductor cable of suitable size 0.75 Sqmm complete all as specified.
Supply and fix exhaust fan 200 mm sweep alongwith louvers/front grill, made of sturdy engineering plastic complete, suitable to work on AC, single phase, 230 Volts, 50 Hz supply and including connecting up with twin core twisted flexible copper conductor cable of suitable size 0.75 Sqmm complete all as specified.
Supply and fix ceiling fan 1200 mm sweep complete eith accessories, single phase, 230 volts, including connection with twin core twisted flexible copper conductor cable, complete all as specified and directed by engr-in charge.
M&L for point wiring with 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including PVC Casing and Caping and its all accessories of suitable size on wall/roof surfaces including one run of 1.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing including provision of Gang box / 2.0mm thick MS terminal box as per site requirement for fixing switches, sockets, fan regulators etc fixed to wall with 3mm thick laminated sheet top cover complete all as specified for:-
One light point/ fan point / bell point controlled by one switch
One 3 pin 5 Amps socket point controlled by one way switch on same board.
One 3 pin 5 Amps socket point controlled by one switch on independent board
All as per item No.183 here-in-before but with 4.0 Sqmm for 3 pin 15 Amps socket point controlled by one switch on independent board and 4.0 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
Taking down carefully service connection of any type complete all as directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m depth and n exc 1.5 m in wide for foundation etc or for shafts, wells cessipts, manholes, pier holes and for laying cables etc and getting out in soft/loose soil.
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
Returning, filling in including spreading, levelling,watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core, laid in trenches / duct / fixing on walls / poles or passing through HDPE double wall corrugated pipe (outer dia should not be less then 40 mm) including connecting with suitable lugs, glands, nuts and bolts in existing Panel from pole / Main Panel Box and testing complete all as specified and directed. Note:- HDPE pipe rate shall be deemed in quoted rate above.
Supply & fixing powder coated CRCA steel sheet MCB distrbution board, IP-43 IK-09 protection, double door recess mounted, triple pole and neutral 4 way with 200 Amps rated bus bar, type complete all as directed.
Material and labour for Earthing complete with GI earth plate 600mm x 600mm x 6 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI wire 4.0 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES schedule Part-I and incl 15 mm bore light grade GI protection pipe (upto 7.5 metres beyond outer edge of earth pit) PCC M-10 grade (Nominal Mix) using 40mm graded stone aggregate in pit with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate, reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and chaarcoal filling, necessary excavation and earth work complete.
Supply & Fixing Modular fan Regulator electronic step type 1 Modular complete all as specified.
S&F electric fan heater (electric blower/room heater) of capacity 2000 watt operated at 230volt,50Hz, speed control of fan, white colour complete all as specified and directed.
Supply & Fixing electric fan heater (electric blower/room heater) of capacity 1000 watt operated at 230volt,50Hz, speed control of fan, white colour complete all as specified and directed.
Taking/opning the body of electric fan blower of capacity upto 2000 watt any type any make, cleaning of internally, checking and tighting of all terminal connections including replacement of worn out heating coil, fan motor, terminal connectors, screws, bolts etc complete all as specified and directed. Note: All major part will be paid separately against appropriated items of BOQ.
Supply only heating coil of capacity 2000watt for heating blower of existing make and type complete all as specified and directed.
Supply only heating coil of capacity 1000watt for heating blower of existing make and type complete all as specified and directed.
Supply only fan motor complete set as per existing model and type complete all as specified and directed.
Supply only controlling knob complete set as per existing model and type complete all as specified and directed.
Supply only controlling switch (on/off) complete as per existing motel and type complete all as specified and directed.
Supply only front grill as per existing make and type complete all as specified and directed.
B R ENTERPRISES
shyam construction
Ahmed constructions
M/s Singh Engineering Corporation
JWALA ELECTRIC CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .