Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹30.7 LAccepted-AOC PLOT NO 42 SURAJ NAGAR MANKAPUR RING ROAD NAGPUR 440013 | NAGPUR | NAGPUR | MAHARASHTRA | 440013 | 1 | Accepted-AOC Award of Contract | |
| 2 | 2₹31.6 L+₹89,580 (2.91%)Rejected-Finance | 2 | Rejected-Finance Evaluated | |
| 3 | 3₹32.3 L+₹1.6 L (5.18%)Rejected-Finance | 3 | Rejected-Finance Evaluated | |
| 4 | 4₹32.9 L+₹2.2 L (7.15%)Rejected-Finance | 4 | Rejected-Finance Evaluated | |
| 5 | 5₹33.1 L+₹2.4 L (7.67%)Rejected-Finance 00 00 BAIRIYA NEAR KALI MAA MANDIR BALLIA UTTAR PRADESH 277502 | BALLIA | UTTAR PRADESH | 277502 | 5 | Rejected-Finance Evaluated |
Tender Value
₹49.0 L
EMD Value
₹98,020
Closing Date
4 May 2024, 6:00 pmClosed
Garrison Engineers (North) Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
PROVISION OF PT SHED (45 Mtr x 20 Mtr) AND CERTAIN SPECIAL REPAIR AND MINOR WORKS AT ACCS UNDER GE (N) AHMEDNAGAR
2024_MES_649998_1
8847/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineers (North) Ahmednagar
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Garrison Engineers (North) Ahmednagar
₹98,020
Yes
29 May 2024
13 Apr 2024
6 May 2024
13 Apr 2024
4 May 2024
27 Apr 2024
Amount
Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in any type of soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50m & making good surface
Excavation over areas not exceeding 1.5 M deep and getting out in soft/loose soil.
Moorum filling in floors/pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed/ rolled including watering to required level and gradient.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out and getting out in any type of soil.
Returning filling under floor including spreading, watring and well ramming in layer n.exc 25cm each in any type of soil.
Removing excavated material exc 250m and depositing where directed at a level n exc 500 m above the starting point.
M&L PCC 1:4:8 type D-2(40mm graded aggregate) in foundation , sub base, filling and mass concrete.
M&L Brickwork old size with fly ash bricks, straight or curved on plan exc 6m mean radius, built in in cement mortar (1:6)
M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement
M&L for preparing new plastered surfaces and applying Two coats of cement base paint over a coat of alkali resistant primer on surfaces of walls.
M&L for Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.Fe-410-W(Gde-E-250)quality-B
M&l for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming toI. S.1161-1979 grade St.-240 ®.
M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer.
M&L, Hardcore of broken stone of gauge n exc 63mm deposited, spreaded & levelled in layers n exc 15cm thick including watering and ramming etc complete.
Material and labour for 75 mm thick plain cement concrete 1:4:8 type D2, using 40 mm graded stone aggregate as in sub base all as directed.
M & L Cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less.
M&L for forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ in 100 mm thickness of flooring.
Taking down carefully existing unserviceable bitumen felt(any number of layers) including plaster of any thickness, wire brushing and cleaning of the surface of roof terraces including flashing and junctions of parapets kerb wall, PCC fillets, benching etc and removing of the rubbish to a distance not exceeding 500 m from the building and depositing where complete all as specified and directed
M&L for rendering 5 mm thick in CM (1:4) on roof slab top finished even and fair without using extra cement complete all as specified.
M&L for cleaning the newly plastered surfaces of concrete (roof etc) with wire brushes and applying water proofing treatment as under :- (i) Checking the roof slab by flooding test with water till total elimination of leakage/seepage/ dampness all as specified in SSR Part-I (after ascertaining location of leakage/seepage/ dampness, carrying out treatment vide item No. hereinafter of pressure grouting shall be operated at the required locations). (ii) Brushing surface with neat cement slurry at the rate of 3.00 kg of cement per Sqm. (iii) Applying one coat of oil bound bituminous primer @ 0.25 kg/Sq. M (iv) Providing and laying 3mm thick APP modified water proofing membrane weighing not less than 3.5 Kg/Sqm reinforced with non woven polyester mat weighing not less than 160 gm/Sqm all as specified procured from any one of the approved manufactures (v) Apply two coat of solar reflective bituminous aluminium paint @ 0.15 kg/Sqm per coat over membrane over non assesble roof surfaces complete all as per manufactures instructions and as directed
Material and labour for submain wiring in PVC Conduit Pipe FRLS PVC insulated copper conductor wire of size 2x1.5 sqmm+1x1.5 sqmm earth wire complete all as specified and directed by Engineer-in-charge
M&L ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directed by Engineer-in-Charge
S & F in replacement double door Sheet metal enclosures factory made DBs SPN, 8 way ,240 volts ,protection class IP-42, suitable for fixing of MCBs,, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed.
Supply & fixing MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCBs, SPN, AC, 240 volts of 40 Amps capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply and fix environmental friendly, energy efficient, extruded aluminium batten LED Tube light fitting 40 Watt with LED light source 6500 K with uniform light output, with all mounting accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement energy saving and environmental friendly long life LED street light 30 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and high performance polycarbonate optics Ingress Protection- IP66 , 4 KV in built surge protection with top opening driver cover for easy maintenance& efficacy 120 lm/W fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge
M & L for Supply,laying ,connecting ,testing and commissioning and jointing , LT underground cable in replacement ,1100 volts grade, XLPE insulated, armored with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in ducts, fixed on poles/walls with proper size saddles and clamp complete all as specified and as directed by the Engineer-in-Charge of following Sizes :- (a) LT cable 10 Sqmm, 2 core. Note : Excavation & earthwork will be measured and paid seprately under relevent items of this schedule.
Excavation in trenches n. exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil etc complete all as specified and directed by Engineer-in-Charge
Supply & lay DWC HDPE pipe 40 mm bore for laying of LT cable complete with all accessores etc complete all as specified and directed by Engineer-in-Charge
Material & labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground. Earth pit not less than 2.25 m depth and top edge of the earth plate not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts & washer etc. Earth wire connected upto main earth point / DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 using granded stone aggregate and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of TMT bar @ 100 mm CIC, both way, lifting arrangement complete including all necessary earth work etc complete all as specified and directed by Engineer-in-Charge
Supply and install hi wall split units indoor/outdoor of Capacity 1.5 Ton complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and Efficient & Hyper Tropical Inverter Split AC with Copper , blue film condensor and it is Equipped with R410 A gas Refrigerant having 2.5 mtr long reach Air flow,6 speed fan control,noise level within 34 db , with warranty 01 year warrenty, equipped with Indoor/Outdoor, remote Etc.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA complete all as specified and as directed.
M/s Mauli Construction
MATOSHREE CONSTRUCTION
M/s. Shahabad Enterprises
Neha Enterprises
MS. N.R. PENTA AND SONS
M/s. A P INFRA
M/S. M. F. Sharif & Co.
Avinash B Kullal
OM SAI ASSOCIATES
AZAD SERVICES
M/s AG PATHAN
MS. G.A. CONSTRUCTION
Galaxy Construction
DAKSH ENGINEERS AND BUILDERS
MS. A.S. CONSTRUCTION
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .