Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 CrAccepted-AOC | ₹6.1 Cr Quoted ₹6.3 Cr | L1 | Accepted-AOC Being L 1 Bidder |
| 2 | L2₹6.5 Cr+₹24.2 L (3.85%)Rejected-AOC | ₹6.5 Cr+₹24.2 L (3.85%) | L2 | Rejected-AOC Not being L 1 Bidder |
| 3 | L3₹6.7 Cr+₹42.7 L (6.77%)Rejected-AOC ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹6.7 Cr+₹42.7 L (6.77%) | L3 | Rejected-AOC Not being L 1 Bidder |
| 4 | L4₹7.0 Cr+₹70.7 L (11.2%)Rejected-AOC 2 11 SADAR BAZAR DELHI CANTT 110010 | DELHI | NEW DELHI | DELHI | 110010 | ₹7.0 Cr+₹70.7 L (11.2%) | L4 | Rejected-AOC Not being L 1 Bidder |
| 5 | L5₹7.5 Cr+₹1.2 Cr (18.9%)Rejected-AOC PLOT NO 178 A MLA COLONY ROAD NO 12 BANJARA HILLS HYDERABAD 500 034 | HYDERABAD | TELANGANA | 500034 | ₹7.5 Cr+₹1.2 Cr (18.9%) | L5 | Rejected-AOC Not being L 1 Bidder |
Tender Value
₹8.1 Cr
EMD Value
₹7.3 L
Closing Date
28 Sept 2024, 6:00 pmClosed
CHIEF ENGINEER CHENNAI ZONE
HQ CE CHENNAI ZONE ISLAND GROUNDS ANNA SALAI CHENNAI 600009
ADDN ALTN OF SELECTED JCOS OR MD ACCN OF SANJAY LINES LAKE LINES AND ENGINEER LINES AT SECUNDERABAD
2024_MES_657547_2
89083/E8
Open Tender
Civil Works
Item Rate
540 days
SECUNDERABAD
Please refer tender documents
7 documents required · 7 mandatory
₹3,000
Yes
Garrison Engineer (North) Secunderabad
₹7.3 L
Yes
23 Dec 2024
14 Sept 2024
3 Oct 2024
14 Sept 2024
28 Sept 2024
21 Sept 2024
Amount
Demolition of cement concrete of any description and in any position not otherwise specifically provided in roof padding concrete etc. including taking down of old bituminous tarfelt or any other type of roof treatment removal the debris to distance exceeding 250 metres and not exceeding 500 metres from the site and cleaning of the roof surface with wire brush to make it free from dust, dirt etc. complete all as specified and as directed Note: Taking down of old bituminous tarfelt or any other roof treatment completely shall be carried out first in a separate operation before starting of demolition of the cement concrete.
Material and labour for PCC 1:2:4, Type B0 using 12.5 mm graded aggregate mixed with integrated water proofing compound as per manufacturer's instructions as in levelling course, haunching and similar works over RCC roof surface and RCC over head tank top surface including rounded or chamfered on edges and formwork etc., complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately under relevant item in this schedule
Material and labour for rendering 10mm thick on roof surfaces in cement mortar 1:3 duly mixed with water proofing compound as per manufacturer's instructions and finished even and smooth complete all as specified and as directed Note: Water proofing compound will be measured and paid separately under relevant item in this schedule
Material and Labour for cleaning the top surface of roof with wire brush and washing with hydrochloric acid to remove dust, dirt, oil, grease, loose particles etc., and providing water proofing treatment with five layered APP modified prefabricated membrane conforming to IS 16540-2017/ IS 16532-2017, matt finish, 3 mm thick and weighing not less than 3.6 kg/sqm reinforced with non woven polyester matt black weighing not less than 150 gm/Sqm, having softening point not less than 140 degree Celsius, longitudinal tensile strength not less than 300 N/Sqm, laid over one coat of oil based bitumen emulsion primer at 0.40 Kg/sqm bonded with bonding material of blown type bitumen of grade 85/25 heated to a working temperature of 180 degree C and applied at the rate of 1.20 Kg/Sqm and laid membrane with torch application using gas burner with 150 mm overlap on side lap and end lap as per manufacturers instructions and finished with a layer of one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm per coat etc., complete all as specified and directed. Note: (i) The work shall be executed through Manufacturer's authorised applicator approved by GE. (ii) The quoted rate is deemed to include the cost of digital photograph and plaster plate as per PS.
Material and Labour for cleaning the top surface of roof with wire brush and washing with hydrochloric acid to remove dust, dirt, oil, grease, loose particles etc., and providing water proofing treatment with five layered APP modified prefabricated membrane conforming to IS 16540-2017/ IS 16532-2017, matt finish, 3 mm thick and weighing not less than 3.6 kg/sqm reinforced with non woven polyester matt black weighing not less than 150 gm/Sqm, having softening point not less than 140 degree Celsius, longitudinal tensile strength not less than 300 N/Sqm, laid over one coat of water based bitumen emulsion primer at 0.40 Kg/sqm bonded with bonding material of blown type bitumen of grade 85/25 heated to a working temperature of 180 degree C and applied at the rate of 1.20 Kg/Sqm and laid membrane with torch application using gas burner with 150 mm overlap on side lap and end lap as per manufacturers instructions etc., complete all as specified and directed. Note: (i) The work shall be executed through Manufacturer's authorised applicator approved by GE. (ii) The quoted rate is deemed to include the cost of digital photograph and plaster plate as per PS.
Material and labour for applying one coat of blown type bitumen of grade 85/25 heated to a working temperature of 180 degree C and applied at the rate of 1.20 Kg/Sqm over APP membrane on roof surface etc., complete all as specified and as directed. Note: (i)The work shall be executed through Manufacturer's authorised applicator approved by GE. (ii) APP membrane shall be measured and paid seperately.
Material and labour for 20mm thick screed bed in CM 1:4 mixed with water proofing compound as per manufacturer's instructions on roof surface etc., complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately under relevant item in this schedule
Material and labour for laying Hydraulically pressed PCC tiles of size 300mm x 300mm, 20mm thick with grey cement and no pigments, set, jointed, grouted and pointed flush with grey cement slurry mixed with polymeric based liquid water proofing additive as per manufacturer's instructions on roof surface etc., complete all as specified and as directed Note: Polymeric based liquid water proofing will be measured and paid separately.
Supply only Integral water proofing compound conforming to IS:2645-2003 complete all as specified and as directed.
Supply only polymer based liquid water proofing compound conforming to relevant IS complete all as specified and as directed..
Material and labour for making the grooves to 'V' section in existing parapet walls/columns over RCC roofs, cleaning out and tacking with polymeric membrane in to the grooves and sealed solidly with a hot mixture of bitumen and clean dry sand in the ratio of 1:1 by weight etc complete all as specified and directed.
Dismantling Mangalore pattern roofing tiles single layer including ridge tiles laid, bedded in cement mortar etc complete all as specified and as directed.
Dismantling of CGI/PGI sheet roofing any gauge and any thickness including ridge, valley gutter, wind ties etc complete all as specified and as directed.
Dismantling battens for roof tiles any size exceeding 15cm in spacing complete all as specified and as directed.
Dismantling timber fillets, rails, posts, rafters, purlins, etc. not exceeding 40 sq. cm in section, in framed work complete all as specified and as directed.
Dismantling timber fillets, rails, posts, rafters, purlins, etc. not exceeding 40 sq. cm in section, in unframed work complete all as specified and as directed.
Dismantling timber scantlings 40 sq. cm and over in section, in framed work, in any position complete all as specified and as directed.
Dismantling timber scantlings 40 sq. cm and over in section, in unframed work, in any position complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets etc., complete all as specified and directed.
Supply, fabricate and erection / fixing of Rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters etc., fixed with angle cleats or other connecting plates etc conforming to Fe-410-W, Grade E-250, Quality A complete all as specified and as directed.
Supply, fabricate and erection / fixing of Rolled mild steel sections as in Roof trusses (framed) and connecting plates, etc., (cut to ordinary lengths i.e. within 20mm of the length indicated of Fe 410-W ( Gde-E-250) quality A complete all as specified and as directed.
Supply and Fix mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk forming holes, without any attachment etc. in roof trusses (framed) and connecting plates, etc., including necessary precautionary measures as in supports etc., complete all as specified and as directed.
Supply and Fix wind ties for roof including securing bolts including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Grade E-165 etc complete all as specified and directed.
Supply and Fix Mild steel bolts purpose made with hexagonal or forming holes, without any attachment dia of neck exc 20mm not exc 25mm complete all as specified and directed.
Supply and fix profiled (trapezoidal profile) Pre-painted galvalume aluminium zinc coated steel sheet 0.50mm thick (TCT) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, cut as per site requirement, fixed with self drilling/self tapping screws with EPDM seal as per manufacturer's instructions etc., complete all as specified and as directed.
Supply and fix Pre-painted galvalume aluminium zinc coated plain steel sheet 0.50mm thick (TCT) of any colour having tensile strength of 550 Mpa as in ridges, valley gutters, hips etc, cut as per site requirement, fixed with self drilling/self tapping screws with EPDM seal as per manufacturer's instructions etc., complete all as specified and as directed.
Supply and Fix 4mm thick high pressure steam cured (HPSC) pre primed self designer textured non asbestos fibre cement building board laid/ inserted to aluminium frame work in false ceilings including aluminium anodised snap grid frame work of size 605 x 605mm with hangers 6 mm dia. G.I. (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long etc., complete all as specified and as directed.
Demolition of concrete in sunken floor including removal of filling etc., complete and removal of demolished material to outside MD land complete all as specified and as directed.
Material and Labour for rendering 15 mm thick in cement mortar 1:3 on fair face of brickwork or concrete surfaces of sunken floors duly mixed with water proofing compound as per manufacturer's instructions and finished even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately under relevant item in this schedule
Material and Labour for cleaning the surface of sunken portion with wire brush and washing with hydrochloric acid to remove dust, dirt, oil, grease, loose particles etc., and providing water proofing treatment with five layered APP modified prefabricated membrane conforming to IS 16540-2017/ IS 16532-2017, matt finish, 3 mm thick and weighing not less than 3.6 kg/sqm reinforced with non woven polyester matt black weighing not less than 150 gm/Sqm, having softening point not less than 140 degree Celsius, longitudinal tensile strength not less than 300 N/Sqm, laid over one coat of water based bitumen emulsion primer at 0.40 Kg/sqm bonded with bonding material of blown type bitumen of grade 85/25 heated to a working temperature of 180 degree C and applied at the rate of 1.20 Kg/Sqm and laid membrane with torch application using gas burner with 150 mm overlap on side lap and end lap and finally laying 150micorn (heavy duty) Polyethylene film micron conforming to IS: 2508-1977 laid with over laps bonded with cold cut back bitumen adhesive, overlaps being not less than 150 mm. The film shall be black in colour complete all as specified and directed. Note: (i) The work shall be executed through Manufacturer's authorised applicator approved by GE. (ii) The quoted rate is deemed to include the cost of digital photograph and plaster plate as per PS.
Material and labour for providing Plain Cement Concrete 1:5:10, type E2, using 40 mm graded stone aggregates for filling in sunken floor and mass concrete complete all as specified and as directed.
Material and labour for providing Reinforced Cement Concrete 1:2:4 (nominal mix), type B1, using 20 mm graded aggregate as in Beams, cantilevers, bressummers, Lintel over 1.5 m span, etc complete all as specified and as directed.
Material and Labour for providing precast cement concrete 1:2:4, type B1 (Using 20 mm graded granite stone aggregate) as in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:4 including use and waste formwork complete all as specified and as directed. Note: Reinforcement bars shall be measured and paid separately.
Material and labour for providing Reinforced Cement Concrete 1:2:4 (nominal mix), type B1 using 20 mm graded aggregate as in RCC slabs supported on walls, beams and columns in floors, roof, landings, balconies, canopies, deck slabs and in shelves and the like etc., complete all as specified and as directed.
Material and labour for formwork to sides and soffits of floor or roof beams, beam haunhings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams etc as in rough finished flat surfaces of concrete complete all as specified and as directed.
Material and labour for Formwork for rough finished surfaces to soffit of suspended slab such as roof slab, floor slab /chajjas beams/cols /fins/ facia and spiral stair case not exceeding 200mm thick complete all as specified and as directed.
Material and labour for Mild steel TMT bars of quality conforming to Fe-500D in reinforcement, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Material and labour for mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders etc and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-500D complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar with all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles including disposal of the rubbish out off the premises complete all as specified and as directed.
Taking down cement plaster of any description and thickness on brick walls, ceiling, etc including racking out joints, hacking for key, scrubbing down with water etc., complete all as specified and as directed
Material and labour for brick work with fly ash bricks, straight or curved on plan exceeding 6 metre mean radius with old size bricks built in CM 1:6 complete all as specified and as directed.
Material and labour for stone walling of squared rubble masonry regular coursed, Secunderabad type, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and as directed
All as per item No.40 here-in-before but except stones complete all as specified and directed. Note- Serviceable stones obtained vide demolition item above shall be reused after removing mortar and cleaning with water complete all as specified and directed.
Material and labour for brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
Material and Labour for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surface even and smooth without using extra cement complete all as specified and as directed
Material and Labour for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and as directed
Material and labour for rendering in Cement Mortar 15mm thick in two coats, i.e., in Cement Mortar 1:4, 5mm thick mixed with liquid water proofing compound as per manufacturers' instructions over a backing coat of Cement Mortar 1:6, 10mm thick on fair faces of brick/concrete surfaces, finished even and fair complete all as specified and as directed. Note: Liquid WPC will be measured and paid separately.
Material and labour for rendering 5 mm thick on concrete surfaces such as ceiling or soffits of chajjas etc; in CM 1:3 finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for preparing newly plastered wall surfaces of walls and applying two coats of distemper oil emulsion over 2 mm thick wall care putty over alkali resistant primer etc., complete all as specified and as directed.
Material and labour for complete removal of existing treatment on wall surfaces and applying two coats of 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of required shade and colour over a coat of primer including providing 3mm thick wall care putty etc., complete all as specified and as directed.
Material and Labour for preparing newly plastered wall surfaces and applying three coats of white wash complete all as specified and as directed.
Material and Labour for preparing the old plastered or unplastered decorated surfaces of walls and applying two coats of white wash complete all as specified and as directed.
Material and labour for preparing newly plastered ceiling surfaces and applying three coats of white wash complete all as specified and as directed.
Material and labour for preparing old plastered ceiling surfaces and applying two coats of white wash complete all as specified and as directed.
Material and labour for preparation of new plastered surfaces on walls, chajjas, filling of hair line cracks with white cement and applying two coats of exterior emulsion weather proof paint over a coat of primer as per manufacturer's instructions including preparation of surfaces etc., complete all as specified and as directed.
Material and labour for complete removal of existing treatment by sand blasting method, washing with water and bleaching powder solution on external surfaces of wall and applying two coats of weather proof exterior acrylic emulsion paint over a coat of exterior primer (or) base coat as per manufacturer's instructions external wall care putty to make the surface even and smooth, rubbing with sand paper of suitable grade etc., complete all as specified and as directed.
Demolition of PCC of any description and in any position not otherwise specifically provided for (un-reinforced) and removal of rubbish/ demolished materials to out side MD land complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil etc., complete all as specified and as directed.
Material and labour for 75 mm thick Plain Cement Concrete 1:4:8, type D2, using 40 mm graded stone aggregates as in subbase to floor etc., complete all as specified and as directed.
Material and labour for designer rubber moulded chequered cement concrete tiles, 25mm thick of size 300mm x 300mm with mixture of grey and white cement in equal proportions with pigments and set and pointed in neat cement slurry in floors over and including 15mm thick screed in cement mortar 1:6 etc., complete all as specified and as directed.
Material and labour for laying of machine pressed precast concrete interlocking paver block, 60 mm thickness, M-35 grade with grey cement and pigments of any shape and size confirming to IS 15658-2006 over and 50mm thick compacted sand cushioning complete all as specified and as directed.
Material and Labour for 75 mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) in plinth protection laid in alternative bays finished even and smooth without using extra cement including making 10 mm wide grooves to full depth at 3 m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight and top 10 mm depth sealed with sealing compound grade ‘A’ complete all as specified and as directed
Material and labour for PCC 1:2:4, type B1, using 20mm graded aggregate as in copings, kerbs, channels, water through and the like including necessary form work weathering slightly rounded or chamfered angles etc., complete all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding , removing rubbish off the premises complete all as specified and directed.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and as directed.
Material and labour for coloured Non Skid ceramic tiles of grade B-II(a), 7 to 8 mm thick (square/ rectangular), light coloured group, area of each tile exceeding 0.06Sqm but not exceeding 0.11 Sqm, laid in floors of pattern as approved, set and jointed in neat cement slurry and pointed in white or coloured cement over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed
Material and labour for glazed coloured ceramic tiles of grade B-III, 7mm thick of size 350x 250mm / 450x300mm matching to floor tile as approved, fixed on vertical surfaces such as in skirting/dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match floor tile over and including 10 mm thick backing coat in cement mortar 1:4 complete all as specified and as directed.
Roughening of surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust complete all as specified and as directed.
Material and labour for coloured Non Skid ceramic tiles of grade B-II(a), (square/ rectangular), light coloured group, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm of 7 to 8 mm thick, laid in floors of pattern as approved, set and jointed in neat cement slurry and pointed in white or coloured cement over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed
Material and labour for coloured Non Skid ceramic tiles of grade B-II(a), (square/ rectangular), light coloured group, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm of 7 to 8 mm thick, set and jointed in neat cement slurry and pointed in white/coloured cement laid over and including 10 mm thick screed in cement mortar 1:4 as in skirting / raisers complete all as specified and as directed
Material and Labour for Joint free 600 x 600mm coloured Ceramic tiles of grade B-II(a) 7 to 8mm thick, in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement over and including 15mm thick screed bedding layer in CM 1:6 complete all as specified and as directed
Material and Labour for Joint free coloured Ceramic tiles of grade B-II(a) 7 to 8mm thick (square/ rectangular) on vertical surfaces as in skirting etc. set and jointed in neat cement slurry/paste and pointed in white or coloured cement over and including 10mm thick plaster in CM 1:4 complete all as specified and as directed
Material and labour for Granite work (of any type) of thickness 18 -20mm (of any size) machine cut, Jet Black granite slab, table rubbed and polished, laid over and including 15mm thick cement screed in cement mortar 1:4, bedded and jointed with grey cement slurry and pointed with white cement (1:2) using marble dust and admixture of pigments to match with shade of granite stone including cutting, polishing and rounding to edges of stone slabs etc., complete all as specified and as directed.
Material and labour for Machine cut polished kota stone slab 20-25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and machine cut polishing with mirror finish and rounding to edges of stone slabs, over and including 15mm thick screed bed or bedding layer of mortar in cement mortar 1:6 as in treads of staircase complete all as specified and as directed.
Material and labour for Machine cut polished kota stone slab 20-25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and machine cut polishing with mirror finish as in skirting / riser of staircase over and including a backing coat of 10mm thick in CM 1:4 complete all as specified and as directed.
Drilling holes of suitable dia for passing tubes of any description into or through RCC cooking platform slab with stone or brick wall etc. and the like of thickness not more than 150mm by electric drilling machine and making good complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) of size not exceeding 1.5 Sqms each complete all as specified and as directed
Taking down chowkats or frames with shutters (without taking off shutters from frames) of size exceeding 1.5 sqm and not exc 4.00 sqm each complete all as specified and as directed
Taking down shutter of any description exc 1Sqm and n.exc 2 Sqm each complete
Taking down shutters of any description exceeding 1.00 sqm but not exceeding 2.00 sqm each and refixing in the same opening including easing and adjusting including renewal of unserviceable screws etc. complete all as specified
Supply and Fix factory made solid PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet, reinforced with 19mm MS square tube of 19 gauge mitred out at two corners and joined by inserting two Nos of 150mm long brackets of 15mm x 15mm MS square tube inside the drilling 100mm long MS screws using PVC fastener as per manufacturer's instructions complete all as specified and as directed.
Supply and Fix factory made Factory PVC door shutter made solid panel of plain colour, 30mm thick (style) consisting of frame made out M.S tube for top & bottom rails. M.S Frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail : Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/scaled the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specifications & drawing given in Section 8 of MES Schedule Part-II 2020 as applicable complete all as specified and as directed. Note: Butt hinges, Barrel tower bolts, handles and sliding door bolts shall be measured and paid separately.
Supply and fix Windows/ ventilators fabricated from roll formed sections made of galvanized steel colour coated/ powder coated (Base steel as per IS 513 “D” quality galvanized as per IS 277 with zinc of 120 gms/Sqr. Mtr.) with total coated thickness of 0.58mm.Sections for Frame should be of 72mm x 55mm, Section for Mullion should be of 72mm x 50mm, Section for Shutter Frame should be of 47mm x 20mm, Section for Fixed Glass Bead should be of 12mm x 12mm, and Section for Fly Mesh should be of 40mm x 20mm Section for Frame Glazed Shutters and Mesh Shutters should be cut to length and miter joined with Polypropylene Corner Brackets, Mullion Section should be joined with Frame/Mullion using Mullion Cap Ethyl Propylene Damien Monomer (EPDM) Gasket should be used all around glass in shutter and Fixed Glass. Spoon Section should be used around Fly mesh to fix Mesh in Mesh Shutter with Stainless Steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm of grade 304 including SS Pivot Hinges – 1 set, Handle & Stay and 4mm plain float glass and Stainless Steel 32 gauge Fly mesh of 25 holes per SqCM and powder coated Grill made of 10mm sq. MS Bars welded at 150mm c/c, 6mm x 12mm MS flat and fixed to window frame with screws complete all as directed Note: Measurement shall be the size of opening and the unit rate quoted shall be deemed to include the cost of Powder coated galvalume sheet sections for frames, shutters, powder coated MS grill, jointing cleats, Stainless steel wire mesh for fly proof, 5mm thick sheet glass, glazing clips, EPDM gaskets, builders hardware etc.
Supply and Fix PVC solid ventilator with frame size 55 X 47mm with wall thickness of 5mm made out of extruded 5mm PVC sheet, mitred cut at two comers and jointed with 2 Nos of 150mm long brackets of 15 x 15mm MS square tube the two vetted profiles are to be reinforced with 19 x 19mm MS square tube the 50% of bottom portion is fixed with 4mm pin headed glass and balance 50% of top portion is fixed with 4mm thick pin headed glass louvers and cover with 0.36mm dia stainless steel wire mesh at top portion including necessary PVC beading with screws and 3 Nos 12mm dia MS guard, bars fixed in ventilator frame including two coats of synthetic enamel paint over a coat of red oxide primer to MS guard bars etc all as per specified and directed. Note: Measurement shall be the size of opening and the unit rate quoted shall be deemed to include the cost frames, shutters painting to MS guard bars, jointing cleats, 4mm pin headed glass, glazing clips, 0.36mm dia stainless steel wire mesh, builders hardware etc.
Supply and Fix Pressed steel frames of size 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc and providing one shop coat of primer and tarring back side of frame complete all as specified and as directed.
Material and labour for Providing Plain Cement Concrete, 1:2:4, type B0, using 12.5mm graded stone aggregate as in filling inside the pressed steel door frames or chowkats complete all as specified and as directed.
Cutting holes in brick wall built in cement mortar for inserting hold fast and making good the disturbed portion in cement mortar 1:3 depth of embedded portion exceeding half brick and not exceeding one brick.
Supply and Fix 35 mm thick factory made second class hardwood, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part I), kiln seasoned and chemically pressure treated. complete all as directed and specified.
Supply and Fix 2nd class hardwood factory made 35mm thick glazed and skeleton door shutters, open rebated and prepared to receive glass, gauge etc., without sash bars, edges of framing plain, chamfered, rounded fitted with cut and mitred beads for securing glass etc, size of members as specified in SSR Part 1 section 8 clause 8.24 (a) supplied and fitted to chowkats complete all as specified and as directed.
Material and labour for preparation of new steel surface of any description exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Material and labour for preparation of old painted steel surfaces of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Material and labour for preparation of new wooden surface of any description exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer etc., complete all as specified and as directed.
Material and labour for preparation of old painted wooden surfaces of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Supply and Fix Stainless Steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with fixed with stainless steel wire staples fixed to frames etc., complete all as specified and as directed. Note: Stainless steel wire cloth provided to windows and ventilators against item No.80.00 and 81.00 hereinbefore shall not be measured against this item
Supply and Fix 150 mm extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
Supply and Fix 150mm aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
Supply and Fix butt hinges of size 100mm extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type C-21 complete all as specified and as directed
Supply and Fix aluminium alloy anodised sliding door bolts 250mm long with hasp, staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded sections complete all as specified and as directed.
Supply and Fix MS helical door spring 300 mm long with roller and roller plate complete all as specified and as directed.
Supply and Fix in repairs 2nd class hard wood plain small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including 50mm Mild steel hinges (medium weight), articles not exc 200cu.cm each complete all as specified and as directed
Supply and Fix in repairs designer aluminium powder coated curtain rod (Drapery rods) 25.4 mm dia exterior grade 3mm thick fixed to brackets, complete all as specified and as directed. Note : Designer curtain rod's brackets will be measured and paid under separate item
Supply and Fix for designer (antique finished) curtain rod's brackets suitable for designer curtain rods as per Srl. Item No.99 here-in-before, fixed to wall with PVC rawl plug and brass screws etc., complete all as specified and as directed.
Supply and Fix 100 mm long Stainless Steel Butt hinges with stainless steel hinge pin complete all as specified and as directed.
Dismantling / Demolition and breaking of old PVC water tank of capacity 500 ltrs to 1000 ltrs with ball valve laid on RCC roof slab carefully without disturbing to existing roof/wall etc., complete all as specified and as directed. Note : If any damage occurs to existing roof / wall during demolition shall be made good by the contractor at his own and without any cost to department.
Supply and Fix, 1000 litres capacity Rotational Moulded Polyethylene (HDPE) FDA grade materials water storage tanks, three layered (Cylindrical vertical with closed top) screwed lid type conforming to IS 12701-1996 with manhole lid and suitable locking arrangement including making holes for inlet, outlet, washout and over flow pipes, hoisted and fixed in position as specified in SSR Part -I (2009) etc., complete all as specified and as directed.
Dismantling / Demolition and breaking of old PVC water tank of capacity exc. 250 and n. exc 500 litres with ball valve laid on RCC roof slab carefully without disturbing to existing roof/wall etc., complete all as specified and as directed. Note : If any damage occurred to existing roof / wall during demolition shall be made good by the contractor at his own and without any cost to department. Dismantling water tanks and removing to store
Supply and Fix, 500 litres capacity Rotational Moulded Polyethylene (HDPE) FDA grade materials water storage tanks, three layered (Cylindrical vertical with closed top) screwed lid type conforming to IS 12701-1996 with manhole lid and suitable locking arrangement including making holes for inlet, outlet, washout and over flow pipes, hoisted and fixed in position as specified in SSR Part -I (2009) etc., complete all as specified and as directed.
Taking up or down steel tubing 15mm bore and connections including cleaning for refxing/ taken on credit complete all as specified and as directed.
Supply and fix Galvanised steel water tubing medium grade 15mm bore conforming to IS specifications and ISI marked with all fittings such as bends, tees, unions, elbows, connecting pieces, plugs, sockets etc fixed on walls/ceiling or laid in floors etc., complete all as specified and as directed. Note: (i) Earthwork excavation, returning filling in and removal of surplus soil if required shall be measured and paid separately. (ii) GI fittings such as bends, elbows, Clamps for fixing on wall, etc are included in the unit rate.
Refixing old Galvanised steel water tubing medium grade 15mm bore and connections in new or old position (Walls, ceiling, floors, etc) after thoroughly cleaning the old pipe, including providing new fittings such as bends, tees, unions, elbows, connecting pieces, plugs, sockets etc., fixed on walls/ceiling or laid in floors etc., complete all as specified and as directed. Note: (i) Earthwork excavation, returning filling in and removal of surplus soil if required shall be measured and paid separately. (ii) GI fittings such as bends, elbows, Clamps for fixing on wall, etc are included in the unit rate.
Taking up or down steel tubing 20mm bore and connections including cleaning for refxing/ taken on credit complete all as specified and as directed.
Supply and fix Galvanised steel water tubing medium grade 20mm bore conforming to IS specifications and ISI marked with all fittings such as bends, tees, unions, elbows, connecting pieces, plugs, sockets etc fixed on walls/ceiling or laid in floors etc., complete all as specified and as directed. Note: (i) Earthwork excavation, returning filling in and removal of surplus soil if required shall be measured and paid separately. (ii) GI fittings such as bends, elbows, Clamps for fixing on wall, etc are included in the unit rate.
Refixing old Galvanised steel water tubing medium grade 20mm bore and connections in new or old position (Walls, ceiling, floors, etc) after thoroughly cleaning the old pipe, including providing new fittings such as bends, tees, unions, elbows, connecting pieces, plugs, sockets etc., fixed on walls/ceiling or laid in floors etc., complete all as specified and as directed. Note: (i) Earthwork excavation, returning filling in and removal of surplus soil if required shall be measured and paid separately. (ii) GI fittings such as bends, elbows, Clamps for fixing on wall, etc are included in the unit rate.
Taking up or down steel tubing 25mm bore and connections including cleaning for refixing / taken on credit complete all as specified and as directed.
Supply and fix Galvanised steel water tubing medium grade 25mm bore conforming to IS specifications and ISI marked with all fittings such as bends, tees, unions, elbows, connecting pieces, plugs, sockets etc fixed on walls/ceiling or laid in floors etc., complete all as specified and as directed. Note: (i) Earthwork excavation, returning filling in and removal of surplus soil if required shall be measured and paid separately. (ii) GI fittings such as bends, elbows, Clamps for fixing on wall, etc are included in the unit rate.
Refixing old Galvanised steel water tubing medium grade 25mm bore and connections in new or old position (Walls, ceiling, floors, etc) with new fittings such as bends, tees, unions, elbows, connecting pieces, plugs, sockets etc., fixed on walls/ceiling or laid in floors etc., complete all as specified and as directed. Note: (i) Earthwork excavation, returning filling in and removal of surplus soil if required shall be measured and paid separately. (ii) GI fittings such as bends, elbows, Clamps for fixing on wall, etc are included in the unit rate.
Supply and fix in repairs Ball valve PTMT with epoxy coated aluminium rod for 20mm bore pipe, weight not less than 210gms, high pressure with polyethylene high density float and complete screwed for iron pipe all as specified and directed.
Supply and Fix in repairs Gun metal globe or gate valve of size 20mm bore confirming to IS 778-1984 with iron wheel head, screwed both ends for GI pipe including all fittings / fixtures like nipple, union etc., complete all as specified and as directed.
Supply and fix in repairs Bib taps 15 mm bore, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle confirming to IS screwed down, screwed for iron pipes or for brass ferrule, complete all as specified and as directed.
Supply and fix in repairs Stop valve / angle cock 15mm bore, cast copper alloy, chromium plated conforming to IS with screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union, complete all as specified and as directed.
Supply and fix in repairs Brass chromium plated shower rose of size 125mm with swivel joints suitable for 15mm dia pipe compete all as specified and directed.
Supply and fix in repairs PVC connection 15mm bore, length 450mm with brass nuts of superior quality complete all as specified and as directed
Supply and fix in repairs vitreous china wash down water closet squatting pan, Orissa pattern of size 580x440mm with integral foot rest ,colour white with and including P or S trap (excluding flushing cistern & flush pipe), providing lean concrete bedding and making necessary connection to soil pipes and flushing cistern etc., complete all as specified and as directed.
Supply and fix in repairs PVC valve less, syphonic action type, low level flushing cistern, 10 litre capacity, white, with accessories like inlet, ball valve, float, handle, brackets, PVC flush pipe, over flow pipe etc., complete all as specified and as directed.
Supply and fix in repairs in repairs vitreous china wash basin, white, flat back, size 580mm X 450mm including CI brackets, 32mm dia brass chromium plated waste fittings with long screwed shanks and fly nuts flanged end bedded in red lead cement and other end fixed, 15mm bore pillar tap, cast copper alloy fancy type chromium plated, screwed down high pressure, 32mm Dia Low density polyethylene pipe (LDPE) of pressure rating 6 Kgf/cm2, cutting for & pinning in end of brackets, complete all as specified and as directed.
Supply and fix Stainless steel kitchen sink of over all size 915mm x 460mm with drain board and bowl size 410mm x 355mm x 175mm made out of 1mm thick stainless steel sheet of grade AI SI-304 with plugs, washers, waste coupling and 40mm dia waste pipe of Low density polyethylene pipe (LDPE) of pressure rating 6 Kgf/cm2, fixed over and including CI cantilever brackets or bedding in cement mortar to dwarf wall as required and connecting union to pipe complete all as specified and as directed.
Supply and fix in repairs Stainless steel Plate rack of size 786mm x 914mm x 254mm with separators and 3 tier shelves made out of 1.00mm thick stainless steel sheet of grade AI SI-304 fixed on wall with rawl plug and chromium plated screws complete fixed all as specified and as directed
Supply and fix in repairs Stainless Steel tubular towel rail, 20mm dia, D type, 600mm long, Chromium plated with flanges fixed on wall with rawl plug and chromium plated brass screws and wooden/plastic cleats complete all as specified and as directed .
Supply and Fix UPVC (SWR) pipes 110mm bore, single socketed in any length with rubber ring joints fixed to walls/ laid in trenches or under floors etc., including demolition and breaking up existing drain pipes and taking out out with fittings etc., complete all as specified and as directed Note: (i) Earthwork excavation, returning filling in and removal of surplus soil if required shall be measured and paid separately. (ii) Clamps for fixing on wall, etc are included in the unit rate.
Supply and fix UPVC (SWR) junction single (single T) equal or unequal 110mm dia with access doors complete
Supply and Fix 110mm dia vent cowl UPVC (SWR)
Supply and fix 110mm bore UPVC (SWR) bend any radius complete all as specified and as directed.
Supply and Fix UPVC (SWR) pipes 75mm bore, single socketed in any length with rubber ring joints fixed to walls/ laid in trenches or under floors etc., including demolition and breaking up existing drain pipes and taking out with fittings etc., complete all as specified and as directed . Note: (i) Earthwork excavation, returning filling in and removal of surplus soil if required shall be measured and paid separately. (ii) Clamps for fixing on wall, etc are included in the unit rate.
Supply and Fix UPVC (SWR) junction single (single T) equal or unequal 75mm dia with access doors complete
Supply and Fix 75mm bore UPVC (SWR) plain bends, any radius
Supply and fix in 110mm bore UPVC (SWR) bend any radius with access door complete all as specified and as directed.
Supply and fix 75mm bore UPVC (SWR) bend any radius with access door complete all as specified and as directed.
Supply and Fix UPVC (SWR) Nahani /Floor trap, 75 mm dia of out let, plain with grating including jointing to waste pipe with solvent and cement concrete type B1 (1:2:4) including removing old trap and fixing of stainless steel grating in round shape etc complete all as specified and as directed.
Supply and Fix UPVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement completed all as specified and directed by Engineer-in Charge.
Taking down carefully existing Unserviceable point wiring of any description / type / size of (light/fan/socket/call bell/two way/Power point) on TW batten/conduit complete including fittings and fixtures such as switches, ceiling roses, shades, brackets, sockets, holders, light fittings, call bells and removing the materials to store for keeping in safe custody for reuse at site or for taking credit including making good the disturbed surfaces of walls/floors/ceilings etc. complete all as specified and as directed.
Material and Labour for providing point wiring with 1.5 sq. mm (nominal area) single core PVC insulated FRLS unsheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade in and including non metallic rigid PVC conduit medium grade with appropriate size with all fittings (ISI Marked) suitable for concealed wiring on wall/ceiling/fixed to roof/truss etc including modular metal flush sunken box of adequate size with suitable modular cover plate with frame for mounting modular switches, sockets, regulators etc. complete with all fittings and accessories fixed to wall/ ceiling for one light/ fan /bell point controlled by one one-way modular switches including one run 1.5 sqmm (nominal area) PVC insulated FRLS unsheathed multi-stranded copper conductor cable green in colour for earth continuity conductor connected to common earth dolly including making good the disturbed surfaces to match with the existing specification, complete all as specified & directed at site. Notes; (i) Cutting chases in brick masonry walls/concrete surfaces for concealed conduit wiring and making good the disturbed surfaces shall be measured and paid separately. (ii) Rate of Modular flush box and cover plate with frame are inclusive of the rate quoted
All as per ser item No. 140 here in before but for one 3 pin socket outlet 5 Amp independent.
All as per ser item No. 140 here in before but for one 3 pin socket outlet 5 Amp on same board.
All as per item No.140 above but for one light point controlled by two nos of two - way switches.
Material and Labour for providing point wiring with 4.00sq. mm (nominal area) single core PVC insulated FRLS unsheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade in and including non metallic rigid PVC conduit medium grade with appropriate size with all fittings (ISI Marked) suitable for concealed wiring on wall/ceiling/fixed to roof/truss etc including modular metal flush sunken box of adequate size with suitable modular cover plate with frame for mounting modular switches, sockets, regulators etc. complete with all fittings and accessories fixed to wall/ ceiling controlled by one one-way three pin modular switch socket 16 amps modular switches including one run 4.00sqmm (nominal area) PVC insulated FRLS unsheathed multi-stranded copper conductor cable green in colour for earth continuity conductor connected to common earth dolly complete all as specified & directed at site. Notes; (i) Cutting chases in brick masonry walls/concrete surfaces for concealed conduit wiring and making good the disturbed surfaces shall be measured and paid separately. (ii) Rate of Modular flush box and cover plate with frame are inclusive of the rate quoted
Supply and Fix Modular switch, single pole, one way, 6 Amps one module complete all as specified and directed.
Supply and Fix Modular switch, single pole, Two way, 6 Amps one module complete all as specified and directed.
Supply and Fix Modular 6A 3 pin universal socket outlet, 2 module complete all as specified and directed.
Supply and Fix Modular switch, single pole, one way, 16 Amps one module complete all as specified and as directed.
Supply and Fix Modular socket outlet 16 Amps, 2 module complete all as specified and as directed.
Supply and fix ceiling rose, surface mount type, PVC/ Polycarbonate, insulated body 3 terminals complete all as specified and as directed.
Supply and Fix lamp holder PVC/ Polycarbonate insulated body with back plate complete all as specified and directed.
Supply and Fix modular stepped type electronic fan regulator 220 volts, 100Watt complete all as specified and as directed.
Supply and Fix modular bell push 6 Amps 1 module complete all as specified and as directed.
Supply and Fix Bell electronic 230 volt, AC single pole complete all as specified and directed.
Supply and Fix 9 W LED bulb of base B22 gear with colour temp 6500K complete all as specified and directed.
Supply, fix, test and commissioning of Wall mounted LED tube light fittings1x22 Watts, 230 Volts Decorative ultra slim aluminium LED lighting fixture with high lumen output, environmental friendly, energy efficient with all accessories, prewired all as per Cat No.LHEXBLP7PN1W022 of Havells or techno-commercially equivalent of other specified makes fixed on surfaces of wall or ceiling with necessary hanging/fixing arrangements and connecting of flexible wire twin core from ceiling rose to fitting drawn through and including flexible conduit etc., complete all as specified and as directed.
Material and labour for concealed sub main wiring complete with two runs of 6.0 Sqmm single core, multistranded, FRLS PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including new non metallic rigid PVC conduit 25mm dia medium grade, ISI marked with conduit fittings and accessories suitable for concealing in walls/ on surface for roof trusses etc including one run of 6.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly etc., complete including taking down and removing the existing sub main wiring complete all as specified and as directed. Note: (a) Two runs of 6.0sqmm multistranded cable and one run of 6.0sqmm cable as earth continuity conductor along with one run of non metallic rigid PVC conduit 25mm dia medium grade shall be considered as one unit length. (b) Cutting chases in brick masonry walls/concrete surfaces for concealed conduit wiring and making good the disturbed surfaces shall be measured and paid separately. (c) The wiring shall be done in proper colour coding using Red, Yellow, blue for phases, black for neutral and green for earth.
Supply, fix, test and commissioning of new generation energy saving and environment friendly long life 35Watts LED security light fitting made up of cast aluminium housing with high power led as lighting source and lens embedded PC cover as diffuser having top opening separate driver compartment with IP66 protection and impact resistance of IK0 suitable for operation on AC single phase 220-240 Volt, 50 Hz supply all as per Cat No.ENDURASUNDOWNSL35WLED765PASYBOPC of Havells or techno-commercially equivalent of other specified makes with all accessories three run of 1.5 Sqmm copper conductor cable drawn through flexible conduit from ceiling rose to fitting etc including lamp bracket alongwith GI medium grade tube of 40mm dia, 1.5 metre long bend to shape 120 degree and 2 Nos of MS clamp 25 x 4mm of required length/size including nuts nd bolts with one coat of red oxide & two coats of silver metallic paint fixed complete with impact and corrosion resistant paint., complete all as specified and as directed.
Refixing of serviceable LED fittings as retrieved from taking down BOQ Item No.138 here-in-before of any wattage, type and make with all accessories internally prewired and connecting up with twisted flexible PVC copper conductor cable of 23/0.0076 from ceiling rose all as specified and directed.
Supply, fix, connecting and testing factory made, prewired Vertical type distribution board, (MCCB DB) TPN, 4 way, having degree of protection IP 43-IK-09 with metal double door, 415 Volts, flush type made out of CRCA sheet metal, duly powder coated and conforming to IS 8623, BS 5486 with 250 Amps rated copper bus bar all as per Cat No.DHDLVDRWAOFO04 of Havells or 5077 45 of Legrand or 811893 of Indoasian or techno-commercially equivalent of other specified makes with common neutral link earth bar, din bar for mounting MCBs, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc as required complete concealed and fixed flush to wall and making good the disturbed surfaces etc., complete all as specified and as directed. including connecting, testing and taking down the existing DB with MCB and MCBs etc., complete all as specified and as directed. Note :- (i) The unit rate quoted shall be deemed to include the cost of cutting chases into walls for concealing MCCB DB and making good the disturbed surfaces with cement work and finishing the surfaces to match with the existing surface. (ii) Incoming MCCB and Outgoing MCBs shall be measured and paid separately.
Supply, fix, connecting and testing MCCB, Four Pole, 100 Amps, breaking capacity 16kA, 415Volts, (lcs=75%lcu) with Fixed Thermal & Fixed Magnetic setting, G Frame conforming to IS: 13947-2 all as per Cat No.IHLGNF0100 # of Havells or techno-commercially equivalent of other specified makes complete all as specified and as directed.
Supply, fix, connecting and testing MCB, Single Pole (SP), 6-32 Amps, 240 volts of rupturing capacity 10kA, 'C' series all as per Cat No.DHMGBSPF006-032 of Havells or techno-commercially equivalent of other specified makes complete all as specified and as directed.
Supply, fix, connecting and testing MCB, Single Pole Neutral (SPN), 40 Amps, 240 volts of rupturing capacity 10kA, C series type all as per Cat No.DHMGCSNF040 of Havells or techno-commercially equivalent of other specified makes complete all as specified and as directed
Material and labour for Earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm, 6.0mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.5m below normal ground level, surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and earth plate connected to galvanized iron (GI) earth lead wire 4 mm dia as earthing conductor by means of bolts, nuts, check nuts and washers of galvanised iron or steel including 15mm bore light grade GI protection pipe up to 7.5 meter long for GI earth wire all as shown in electrical plate No.3 of MES Schedule (Part I) (2009) connected to earth test point/ main switch/ DB testing on completion all as specified including PCC (1:3:6), type C-1 pit with 50mm thick precast cover of size 540mm x 540mm in RCC (1:1.5:3), type A-1 reinforced with 12mm dia MS bars @ 150 mm c/c both ways with lifting hooks made out of 12mm dia MS bars, wire mesh funnel with watering pipe 20mm dia medium grade, as specified including necessary excavation and earth work in any type of soil etc., complete all as specified and as directed.
Material and labour for Earth continuity conductor or main earthing lead of 4mm dia galvanised iron or steel wire including GI protection pipe light grade 15mm bore fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and as directed. Note:- Earth lead and GI Protection pipe provide beyond 7.50 metre in earthing only shall be measured against this item.
Supply and laying GI tubing of 20 mm bore galvanized medium grade of any length including all fittings, socket welded for fan down rod complete all as specified and as directed.
Supply, install, testing & commissioning of Exhaust fan, metal body with automatic back shutter louvers 230 mm sweep, 1400/1350 RPM or more, Air Delivery not less than 510 Cum/Hour, single phase, 240 Volts, AC, 50 Hz all as per Ventil Air - DSP of Havells or techno-commercially equivalent of other specified makes including cutting hole in to the wall / existing window / ventilator etc., and making good the disturbed surfaces and connecting up complete including provision of cable 3/2 core of suitable size from ceiling rose to fan in flexible hose including taking down the old unserviceable exhaust fan etc., complete all as specified and as directed. Note :- The unit rate quoted shall be deemed to include the cost of making hole in walls (RR Masonry or brick wall of any thickness)/other surfaces, making good the disturbed surfaces including any framework/cement work/wood work/welding work etc. required for proper fixing of the exhaust fan and matching to the existing surface.
Disconnecting the electric supply and taking down ceiling fan of 1200/1400mm sweep from any height, sealing cable end, dismantling blades and removing fan and blades and deposit to MES store etc., complete all as specified and as directed.
Hanging/Fixing of ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
Supply, fix, test and commissioning of Energy efficient Ceiling fan with three blades including down rods, stepped type electronic regulator and other accessories, 230 V, 1200mm sweep, Minimum air delivery 210 CFM with service value 6.00 BEE, Five star rated with Brushless Direct Current motor (BLDC) all as per Cat No.Efficiencia Neo (BLDC 26 W) of Havells or techno-commercially equivalent of other specified makes fixed to roof/ceiling with suitable clamp including provisioning of flexible copper cord of size 23/0.0076 of required length from ceiling rose or connector to ceiling fan etc., complete all as specified and as directed.
Taking down and refixing energy meter of any type complete all as specified and directed.
Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings steps, cills, sunshades, shelves, lintels, etc, and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting not exc 10 cm girth complete all as specified and directed.
Supply and fix Electric storage water heater (Geyser) of capacity 25 litres, BEE 5 Star rated, 2 kw, vertical type with tank made of ultra thick super cold rolled steel plates Feroglas dry powder coated, 800 glass coated heating elements (Shock proof and hard water proof) and powder coated metallic body conforming to IS:2082 all as per Cat No.Puro Turbo Dx of Havells or techno-commercially equivalent of other specified makes including drilling holes into the walls, provision of 2 Nos of 450 mm long Hot & cold PVC connections , 4 Nos of suitable size anchor bolts, nuts and washers, connecting up electrical and water supply lines, testing, commissioning and making good the disturbed surfaces etc., complete all as specified and as directed .
Material and labour for Cutting the existing 15/25 mm GI pipe and inserting suitable GI Tee incl necessary threading, union etc complete all as specified and as directed.
Taking down existing LT cable of any description up to size of 3.5 core X 50 sq mm making good the disturbed surfaces of walls, floors etc.
Supply and lay in trenches / drawn through pipes or in road crossings / paths / drains / ducts / floors / along poles / equipments etc., of LT cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade confirming to IS-7098 (Part-I) 1988 of size 16 Sqmm x 4 Core including connecting up using suitable size aluminium lugs testing and commissioning etc., complete all as specified and as directed. Note : Excavation earth work, sand cushioning and brick / PCC cover cable protection shall be measured and paid separately.
Supply and lay in trenches / drawn through pipes or in road crossings / paths / drains / ducts / floors / along poles / equipments etc., of LT cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade confirming to IS-7098 (Part-I) 1988 of size 50 Sqmm x 3.5 Core including connecting up using suitable size aluminium lugs testing and commissioning etc., complete all as specified and as directed. Note : Excavation earth work, sand cushioning and brick / PCC cover cable protection shall be measured and paid separately.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for laying of cables, pipes, laying of poles in trenches and getting out in soft/loose soil complete all as directed and specified.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtrs above from the starting point, spread, levelled uniformly in layers not exceeding 25cm each complete all as all as specified and directed.
Supply, lay / spread in trenches clean dry sand for cushioning of cable to the full width of excavated trench, 8cm thick before laying cable and 15cm thick above the cable, gently punned down, stretching and testing of cable on transformer yard etc., complete all as specified and as directed. Note : Punned thickness only will be considered or payment.
Supply and lay burnt Bricks, old size, sub class "B" of size 230 x 115 x 75mm, laid flat adjacent to each other, perpendicular to cable with width equal to length in trenches for protection of cable etc., complete all as specified and as directed.
Supply and lay GI tube light grade, 40mm nominal dia, ISI marked with all fittings, complete, fixed to walls, pole ceiling or laid in trenches under road crossing/floor for cable protection at road crossing / on poles etc., complete all as specified and as directed. Note:- Excavation and earth work where required shall be measured separately.
Supply and lay GI tube light grade, 50mm nominal dia, ISI marked with all fittings, complete, fixed to walls, pole ceiling or laid in trenches under road crossing/floor for cable protection at road crossing / on poles etc., complete all as specified and as directed. Note:- Excavation and earth work where required shall be measured separately.
Supply, installing, testing and commissioning, factory made and tested, CPRI type tested/OEM tested LT panel board outdoor type, weather, vermin proof, cubical type, semi flush to wall, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed, with necessary bus bar arrangement with insulated bus bar 200 Amps rating , 4 strips, the panel should be dust proof, IP 54 class protection and made out of 3.00mm thick CRCA mild steel sheet , hinged doors, front opening for each chamber arrangement and duly powder coated on the out side and inside, cable glands and lugs for incoming and out going cable etc, independent chamber to Provision of 08 number meters incl plinth of panel of size 1200 x 1000 x 300 mm as requirement of site complete all as specified and directed including following accessories :- (a)MCCB 4 pole adjustable, 125 Amp, 415 Volts 25KA- - 01 Nos (Incoming) (b)MCB ,SP&N 40 Amp, 24 Volts 10KA- - 08 Nos (Outgoing) (c) Panel wiring with suitable size PVC insulated heavy duty 1100 volts grade single core cable with copper conductor multistranded with cable end termination lugs.
Supply, installing, testing and commissioning, factory made and tested, CPRI type tested/OEM tested LT panel board outdoor type, weather, vermin proof, cubical type, semi flush to wall , suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed, with necessary bus bar arrangement with insulated bus bar 200 Amps rating , 4 strips, the panel should be dust proof, IP 54 class protection and made out of 3.00mm thick CRCA mild steel sheet , hinged doors, front opening for each chamber arrangement and duly powder coated on the out side and inside, cable glands and lugs for incoming and out going cable etc, independent chamber to Provision of 05 number meters incl plinth of panel of size 1200 x 1000 x 300 mm as requirement of site complete all as specified and directed including following accessories :- (a)MCCB 4 pole adjustable, 125 Amp, 415 Volts 25KA- - 01 Nos (Incoming) (b)MCB ,SP&N 40 Amp, 24 Volts 10KA- - 05 Nos (Outgoing) (c) Panel wiring with suitable size PVC insulated heavy duty 1100 volts grade single core cable with copper conductor multistranded with cable end termination lugs.
Material and Labour earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note :- The cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with 32x6mm galvanised iron strip all as specified .
Supply and fixing and testing factory made, sheet metal enclosure MCB DB SPN 8 way with suitable rated bus bar 240 volts double door with magnetic locking system all as per Cat No.DHDLVDRWAOFO04 of Havells or techno-commercially equivalent of other specified makes with common neutral link earth bar, din bar for mounting MCBs, terminal connectors for all incoming and outgoing circuits, complete all as specified and as directed
Supply and Fix Weather proof outdoor bus bar chamber made out of 3mm thick MS sheet comprising 4 Nos aluminium strips each of 300Amps, 60cm long duly insulated mounted on insulators including 200 Amps MCCB with 4 No’s mounting legs made out of 25mm x 25mm x 6mm angle iron grouted in PCC block of size 30cm x 30cm x 90cm (30cm depth below ground level and 60cm above ground level) in cement concrete 1:3:6, type C-2 (using 40mm grade crushed stone aggregate), and connections with suitable size of aluminium thimbles, nuts, bolts & washers, cable glands at entry and outlet points and excavation, earth work, returning filling in and removal of surplus soils including taking out old unserviceable bus bar chamber complete all as specified and directed.
R. Wadhumal and Sons (BID ID -3110635)
Shree Construction Co. (BID ID -3107176)
Megha Construction Co. (BID ID -3119022)
SRICO PROJECTS PVT LTD (BID ID -3119166)
Sai construction & services (BID ID -3119283)
M/s Imperial Coastal Infra (BID ID -3110945)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .