| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC 197 4 KANTADANGA ROAD P O FINGAPARA KANKINARA NORTH 24 PARGANAS PIN 743129 | KANKINARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹18.9 L+₹48,272.05 (2.62%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹24.4 L+₹5.9 L (32.2%)Rejected-Finance VILL SAROT PALLY PO SANKRAIL DIST HOWRAH PIN 711313 WB | SANKRAIL | HOWRAH | WEST BENGAL | 711313 | L3 | Rejected-Finance Not Being L1 | |
| 4 | Rejected-Technical KHEMASULI P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPUR WEST BENGAL | KHARAGPUR | PASCHIM MEDINIPUR | WEST BENGAL | - | Rejected-Technical Not meeting the criteria of NIT |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
4 Oct 2021, 6:00 pmClosed
GE (AF) Kalaikunda
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
REPAIR AND MAINTENANCE OF SUMMER AND COOLING APPLIANCES AND REPAIRS AND MAINT OF STREET SECURITY LIGHTS, PAINTING OF POLES AND OTHER ALLIED WORKS AT AF STN SALUA UNDER GE (AF) KALAIKUNDA
2021_MES_473334_1
8701/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AF STN KALAIKUNDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) Kalaikunda
₹70,000
16 Dec 2021
7 Sept 2021
5 Oct 2021
7 Sept 2021
4 Oct 2021
22 Sept 2021
Amount
Comprehensive servicing for Window Type Air Conditioner of any make and capacity installed at various location by carrying out necessary repairs,cleaning of filters, adjustments of assemblies, sub-assemblies, check the level of refrigerant, arresting the leakage of any type, replacement of parts, calibration including cleaning of condensor & evaporator coils fins with mild detergent and descaling of condensor coil for window etc. through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed.
Comprehensive servicing for Split Type Air Conditioner of any make and capacity installed at various location by carrying out necessary repairs,cleaning of filters, adjustments of assemblies, sub-assemblies, check the level of refrigerant, arresting the leakage of any type, replacement of parts, calibration including cleaning of condensor & eveporator coils fins with mild detergent and descaling of condensor coil for Split etc. through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed. (NOTES:- (Applicable for BOQ Serial Item No. 1 to 2 here in before) (i)S&F spare parts will be measured and paid separately under relevant item.) (ii) The Contractor shall provide the following comprehensive services arising out of wear and tear of the normal running of Air Conditioners including maintenance of all mechanical, electrical and electronic parts /sub-assemblies. The preventive maintenance report will be as per the Original Equipment manufacturer's instructions and as specified in Particular Specification. (iii) Breakdown Maintenance : The Authorised Service Engineer of OEM or OEM Certified Agencies will carry out all breakdown maintenance after receiving information (written or oral) from GE (AF) KALAIKUNDA officials or their representatives, The OEM's authorised service representative or OEM certified agencies will carry out the required repairs of the units and appraise GE,Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service during maintenence period including defect liablity period . (iv) The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.200.00 (Rupees Two Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contractor. (v) Cost of minor items like teflon tape,insulation tape, metal washers, fibre/rubber washers, screws, small nuts & bolts and like shall be deemed to be inclusive of the quoted rate. (vi) Spares required for replacement of defective ones will be measured and paid seperately .Each maintenance job shall be covered period of 09 Months
Shifting of split type AC from MES yard / existing location to the new location, filling the opening of old location with cement mortor, applying white wash on wall with existing colour of the site and making opening holes on brick wall at new location, well finish with cement mortor (1:3) , applying white wash, distemper etc on wall to match with existing colour of the adjacent surface , installation and commissioning with replacement of insulation of suction & discharge line as per OEM recommendation complete all as directed
Shifting of window type AC from MES yard / existing location to the site/ new location where directed & installation by making necessary opening of brick wall/ window and preparing gap well finished by cement mortor(1:3) applying white washing or as per existing finish in matching with the existing colour, disposal of waste material/ filling gap with ply wood on front side of AC and outer corner of ply wood applying two coats of enamelled paint over a coat of primer on plywood surface to match the existing location all as directed by the Engr-in-Charge.
Shifting of water cooler/refrigerator electric driven single phase having any make and capacity from MES yard/existing location by taking it after disconnection of electric and water line and refixing the same in any other new location incl water line and electric reconnection complete all as specified and as directed
Supply and fixing in replacement of Printed Circuit Board suitable for 2TR Capacity Split Unit Air Conditioners including remote, as per OEMs specifications, complete suitable for existing type etc all as directed by Engr in charge .
All as per Srl item No 06.00 here-in-before but for 1.5 TR Capacity Split Unit Air Conditioners including remote, as per OEMs specifications, complete suitable for existing type etc all as directed by Engr in charge . . Make LG/equivalent as approved by GE
Disconnecting, dismantling and taking out existing burnt out compressor from window/Split type Air conditioner 2 TR Capacity and supply and fixing sealed unit compressor of existing capacity 2 TR, single phase, 230 V AC supply initialy filled with compressor oil as per OEMs specifications, and testing on load for 24 hrs in summer complete all as specified and as directed
All as per srl item No. 8 here-in-before but Cap 1.5 TR Single phase 230 volts AC 50 Hz complete all as specified and as directed
All as per srl item No 8 here-in-before but suitable for water cooler of capacity 40 to 60 Ltr per Hour single phase 230 volts supply complete all as specified and as directed
All as per srl item No. 8 here-in-before but suitable for water cooler of capacity 80 to 120 Ltr per Hour single phase 230 volts supply complete all as specified and as directed
Disconnecting, dismantling & taking out existing burnt out compressor from domestic type refrigerator Cap upto 286 Ltr S&F hematically sealed compressor unit as per OEMs specifications, existing Make & model including initial charging of sealed compressor with refrigerant gas & testing on load on 24 hrs for smooth functioning complete all as specified and as dire cted
All as per Ser Item No. 12.00 here-in-before but suitable for Cap 300/310 Ltrs per hrs single phase 230 volts AC supply complete all as specified and as dire cted
All as per Ser Item No. 12.00 here-in-before but suitable for chest type Deep freezer Cap 300 Ltrs per hrs single phase 230 volts AC supply complete all as specified and as dire cted
All as per Ser Item No. 12.00 here-in-before but suitable for chest type Deep freezer Cap 500 Ltrs per hrs single phase 230 volts AC supply complete all as specified and as directed
Supply & fixing in replacement of AC blower fan motor for AC suitable for 2 TR AC s as per OEMs specifications,suitable for operation on 230 Volt AC supply at 50 HZ complete all as specified and as directed
All as per Ser Item No.16.00 here-in-before but suitable for 1.5 TR AC window type AC suitable operate on 230 Volt AC supply at 50 HZ complete all as specified and as dire cted
All as per srl item No.16.00 here-in-before but suitable for water cooler of Cap 40/80 Ltrs complete all as specified and as dire cted
All as per Srl item No 16 here-in-before but suitable for water cooler of Cap 150 Ltrs complete all as specified and as dire cted
Supply & fixing in replacement of Capacitor 4 MFD as per OEMs specifications,complete all as specified and as directed
Supply & fixing in replacement of Capacitor 36 MFD as per OEMs specifications,complete all as specified and as directed
Supply & fixing in replacement of Capacitor 45+6 MFD as per OEMs specifications,complete all as specified and as directed
Supply & fixing in replacement of Capacitor 50/55+5 MFD as per OEMs specifications,complete all as specified and as directed
Supply & fixing in replacement of Thermostat switch for water cooler/Window AC as per OEMs specifications,complete all as specified and as directed
Supply & fixing in replacement of Drier stainer filter suitable for AC/Water cooler/Refrigertor as per OEMs specifications,complete all as specified and as directed
S&F in replacement of single pole and neutral enclouser with a two pin and earth plug and socket complete with one MCB single pole 20/25 Amps as per OEMs specifications,complete all as specified and as directed
S&F in replacement of Elastomeric Nitrile Foam Rubber 1/6'' size as per site requirement of approved as per OEMs specifications,complete all as specified and as directed
All as per Srl item No 27.00 here-in-before but 1/8'' size as per site requirement of approved make all as spd and directed .
All as per Srl item No 27.00 here-in-before but 5/8'' size as per site requirement of approved make all as spd and directed .
S&F in replacement of Copper pipe of size 1/4'' of approved as per OEMs specifications,complete all as specified and as directed
All as per item No 30.00 here-in-before but size 1/2'' of as per OEMs specifications,complete all as specified and as directed
All as per item No 30.00 here-in-before but size 5/8'' of approved make as per OEMs specifications,complete all as specified and as directed
S&F in replacement of overload relay 1/6 or 1/8 type as per OEMs specifications,complete all as specified and as directed
All as per item No 33.00 here-in-before but size 4/10 type of approved make as per OEMs specifications,complete all as specified and as directed.
M&L for copper codensing coil for Refrigerator 310 ltrs as per existing make/size as per OEMs specifications,complete all as specified and as directed
M&L for copper codensing coil for 2 TR/1.5 TR split type AC as per existing size all as per OEMs specifications,complete all as specified and as directed
S&F in replacement of Evaporator unit (indoor unit ) complete suitable for 2 TR Capacity Split type Air Conditioners as per OEMs specifications,complete all as specified and as directed
S&F in replacement of Evaporator unit (indoor unit ) complete suitable for 1.5 TR Capacity Split type Air Conditioners as per OEMs specifications,complete all as specified and as directed
S&F in replacement of Out door unit complete excluding compressor etc. Suitable for 2 TR Capcity Air conditioners as per OEMs specifications,complete all as specified and as directed
S&F in replacement of Out door unit complete excluding compressor etc. Suitable for 1.5 TR Capcity Air conditioners as per OEMs specifications,complete all as specified and as directed
Supply and fixing in repair Capillary tube size 50 / 60 Suitable for split/ window type AC of capacity 1.5/2.0 Ton as per OEMs specifications,complete all as specified and as directed
Supply and fixing in repair Bracket stand suitable for 2 TR Capacity Split type AC including Fastners, as per OEMs specifications,complete all as specified and as directed
Supply and charging R-22 gas to maintain the required cooling effect as and when required in the split AC/ window type AC & other cooling applinces (charging cost included in this items deemed to be quoated rates) as per OEMs specifications complete all as specified and as directed
Supply and charging R-134 gas to maintain the required cooling effect as and when required in the water cooler, Refrigerator and other cooling applinces incl (charging cost included in this items deemed to be quoated rates) as per OEMs specifications complete all as specified and as directed
Supply and charging Nitrogen Gas for finding out lekage as and when required (charging cost included in this items deemed to be quoated rates)(charging cost included in this items deemed to be quoated rates) as per OEMs specifications complete all as specified and as directed
S&F in replacement of wall mounted voltage stabilizer 4/5 KVA single phase , 230 volts suitable for ACs as per OEMs specifications complete all as specified and as directed
Supply & fixing in replacement of Copper cable flexible 3 core 4 Sqmm. complete all as specified and as directed
Supply & fixing in replacement of Copper cable flexible 3 core 6 Sqmm.complete all as specified and as directed
Taking down old AL/Copper Sub main wirng and M&L for new Sub main wiring using two single core PVC insulated cable(HR&FR) 6 sqmm copper conductor multi stranded and 6.0 sqmm copper conductor insulated cable (HR&FR)using as earth wire and drawing into PVC Casing and Caping complete all as specified and directed .Note- One run of PVC casing caping , 03 run of 6 sq mm PVC copper wire measured as one Unit
Taking down carefully, existing defective storage type water heater (geyser) of any Capacity and Make for repairing, including replacement of defective spares as required and including replacement of terminals with defective connection wires and reinstallation of the geyser in original position including testing and commissioning, complete all as specified and directed. ( NOTES:- (i) Repairs shall be carried out through authorised technicians of the OEMs as approved by GE. (ii) Spares for replacement will be measured and paid separately. )
Supply only heating element any type (i.e; Cup,thread or triangular) as per existing sample 1.5 KW, 220/230 volts ISI marked as per OEMs specifications, complete.
Supply only heating element any type (i.e; Cup,thread or triangular) as per existing sample 2.0 KW, 220/230 volts ISI marked as per OEMs specifications, complete
Supply only Thermostat switch ISI marked as per OEMs specifications, complete Make: Alcone or equivalent
Supply only Head Assy"Brass" 8 to 9 holes suitable for 25 ltrs capacity as per OEMs specifications, complete
Supply only Head Assy"Brass" 8 to 9 holes suitable for 50 ltrs capacity as per OEMs specifications, complete.
Supplyonly Safety plug "brass" ISI marked suitable for 25/50 ltrs geyers as per OEMs specifications, complete
Supply only Hot water connection made of brass pipe,chromium plated upto 18" length complete with rubber washer & brass nuts, ISI marked as per OEMs specifications, complete
Supply only MS outer cover (body) for storage type water heater of capacity 25 Ltrsas per OEMs specifications, complete
All as per srl item No.58.00 here-in-before but water heater capacity of 50 ltrs as per OEMs specifications, complete
Supply only geyser inner assembly of brass with inlet/outlet & over flow provision rubber washer suitable for 25 ltrs capacity as per OEMs specifications, complete
As per Ser No 60.00 here-in-before but suitable for capacity 50 Ltrs as per OEMs specifications, complete
S&F in replacement of bottom cover plate in two halves suitable and as per sample as per OEMs specifications, complete
S&F phase indicator red colour circular/rectangular shape as suitable and as per sample complete as per OEMs specifications, complete
S&F in replacement of non return brass valve of 15mm bore, ISI marked as specified and directed by Engr-in-Charge.
S&F in replacement of plug top 3 Pin 15 Amps 230 volts all as specified and directed by Engr-in-Charge.
Supply only glass wool as per OEMs specifications, complete
Taking down unserviceable street /flood light / Security light fittings any type or any capacity from any location mounted on any type of Poles/Bdgs/ / Tower/ High mast of height up to 18 mtr from bracket after disconnecting of supply cable and refixing the same after carrying out repair and testing on exiting or new location as per site requirement, including repairing of circuit, electrical connection, replacement of defective driver, surge protection device, tracing and rectifying of fault complete all as specified and as directed by Engineer-in-Charge. Note : (i) Supply only LED driver with SPD and electric supply cable will be measured and paid separately under respective item.) (ii) All T&P, ladder etc required at site for the repairing and taking down / refixing of light fitting after repair shall be arranged by the contractor. (iii) If there is any fault in electrical supply line, it shall be contractor liability to identify the fault and get it repair for making the light functional complete all as directed .
S & F LED street lights nominal power 35 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2500, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No.LR02-391-XXX-57-XX of Wipro or equivalent of Make mentioned under Appendix "B" including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 including taking out unserviceable complete all as specified and as directed.
S & F LED street lights nominal power 60 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 6000, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LR02-671-XXX-57-XX of Wipro or Make:- Crompton Cat No. No.Raptor Neo I , Cat No. TRP-409-60-57-SL-GL-NSG OR equivalent of Make mentioned under Particular specification including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 including taking out unserviceable complete all as specified and as directed.
S & F LED street lights nominal power 70 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 7000, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LR02-781-XXX-57-XX of Wipro or equivalent of Make mentioned under Appendix of PS including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 including taking out unserviceable complete all as specified and as directed.
S & F LED flood lights nominal power 120 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LF20-132-060-57-XX of Wipro or equivalent of Make mentioned under Appendix "B" including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. Note for Item No. 68 to 71(i) If connection.cable from pole Juction box to street light and street light bracket up to 2 mtrs be included and measured in unit rate item, Beyond 2 mtrs of length to be paid seperately under respective items. (ii) At location where street lights/flood light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt. (iv)All LED lights have replacement warranty of 3 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submitt warranty certificate from manufacturer . Payment of light fitting will be released after receipt of 3 year replacement warranty certificate from manufacturer. (v) The LED lights will replaced by the contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly. (vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries. (vii) All LED fitting shall be identified by printing or fixing stickers duly mentioned the C.A number and date of completion. (viii) For any change in product or change in catalogue No. etc due to technological upgradation, letter has to be obtained from the lighting company on their letter head signed by an offical of National level. (ix) All T& P required at site for installation of light on Pole / Bldg /Tower or at any location shall be arranged by contractor .
Supply only in repair LED driver suitable for 15/20/30/ 35 watt LED street light , 240 Volt , 50Hz , AC . Make of Driver : Bajaj /Crompton/ C&S/ Havells/ Surya/Philips/Century (As per existing) Note :(i) Before procurement contractor shall check the make and model of u/s LED driver as per existing and bring the same or suitable to make the light functional.
Supply only in repair LED driver suitable for 45/60/70 watt LED street light , 240 Volt , 50Hz , AC . Make of Driver : Bajaj /Crompton/ C&S/ Havells/ Surya/Philips/Century (As per existing) Note :(i) Before procurement contractor shall check the make and model of u/s LED driver as per existing and bring the same or suitable to make the light functional.
M & L for bracket made out of GI pipe 40 mm dia medium grade, 1.5 metre long bent to shape with MS flat iron clamps made out of 40 mm X 6 mm thick mild steel nuts, bolts including taking down existing GI bracket complete all as directed by Engineer-in-charge including taking down old unserviceable.
M&L for polycarbonate 3 phase busbar system pole junction Box dust, weather rain guarded cable entry and exit arrrangement with closing arrangement of size 300 x 200 x 150 mm with housing of 04 Nos 100 Amps aluminium bus bar fixed on porcelain insulator and connected of cables with lugs, nut bolts and washer including 06 Amps MCB all as specified and as directed.
M&L for polycarbonate 1 phase busbar system pole junction Box dust, weather rain guarded cable entry and exit arrrangement with closing arrangement of size 200 x 150 x 150 mm with housing of 02 Nos 100 Amps aluminium bus bar fixed on porcelain insulator and connected of cables with lugs, nut bolts and washer including 06 Amps MCB all as specified and as directed.
M&L for FRLS wiring in existing locatation for circuit alongwith earth wire 2 x 2.5 sqmm + 1 x 1.5 Sqmm copper cable PVC insulated multistranded from junction box to fitting connecting box etc. (Two run of 2.5 Sqmm wire+01 Run of 1.5 Sqmm wire considered as one unit) all as specified and as directed.
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with stranded aluminium conductor of cross sectional area 70 sqmm 3.5core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking out complete as specified and as directed. (NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule 'A').
All as per item No 78 here-in-before but of size 25 Sqmm 4 core complete as specified and as directed.
All as per item No 78 here-in-before but of size 10 Sqmm 2 core complete as specified and as directed.
Material and labour for 40 mm dia Unplasticiscd PVC pipes of pressure rating 10 kgf/cm2 laid in trenches for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc,including clamps, nut, bolt and washers complete all as specified and directed
All as per item Serial No 81 here-in-before but for 50 mm dia pipe including clamps, nut, bolt and washers.
Material and Labour for applying two coats of aluminium paint on old painted surfaces of steel tubular poles, type 410 SP-22/ SP-31 (8.5/9.00 Metres Long), including cross arms,brackets etc., up to 1.5 M above PCC base and marking alternate strip horizontally of width 15 cm with two coats of synthetic enamel paint (ordinary tint) above PCC base up to 1.5 M height and numbering of poles with letters and figures of height 75 mm at a height of 2.60 metre from ground level including preparation of surfaces complete all as specified and directed.
Material and Labour for applying two coats of aluminium paint on old painted surfaces of steel tubular poles, type 410 SP-41 (11 Metres Long), including cross arms,brackets etc., up to 1.5 M above PCC base and marking alternate strip horizontally of width 15 cm with two coats of synthetic enamel paint (ordinary tint) above PCC base up to 1.5 M height and numbering of poles with letters and figures of height 75 mm at a height of 2.60 metre from ground level including preparation of surfaces complete all as specified and directed.
Supply and fixing Ambient light timer switch i.e nature switch which can works bases on measurement of lux level of Infra red rays along with enclosure box having dust & termite proof outdoor type mountable on electric panel or on pole Single Phase with contactor rating 16 Amps, MCB rating 25 Amps and load bearing 3 KW all as specified and directed by Engineer in charge . Note :- The Timer switch having the following features:- (a) Automatic switching on at Dusk (ambient light less than 60 Lux). (b ) Automatic switching off at Dawn ( ambient light greater than 10 lux). (c) Duration based part night operation facility. (d) High voltage protection ( 280 V ) with auto reset. (e) Low voltage protection ( 150 V ) with auto reset. (f) Immunity to dust , bird sitting ,FOG & cloud cover. (g) Degree of protection conform to IP65.
All as per Ser Item No 85.00 but here in before Three Phase with contactor rating 16 Amps, MCB rating 20 Amps and load bearing 5 KW all as specified and directed by Engineer in charge .
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for in ground/ floors complete all as specified and as directed.
M&L for cement concrete in foundation filling and mass concrete (1:3:6) type C2 (using 40 mm graded stone aggregate) complete all as specified.
Materials and Labour for plain cement concrete (1:2:4) type B1 using 20 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height,copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary from work complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and n.exe 1.5 mtr depth including getting out all as specified and directed. Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor beyond every hours till services restored .
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point all as specified and directed.
Supply and laying sub class ‘B’, bricks, in cable trenches, as cable protection complete all as specified and directed.
M&L in dry coarse sand in cable trenches before and after the cables are laid complete all as specified and directed
JEETEN ENTERPRISE
M/s Santosh Industrial Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .