| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹22.5 L+₹14,096.70 (0.63%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹23.7 L+₹1.4 L (6.14%)Rejected-AOC CHENNAI | L3 | Rejected-AOC Rejected | |
| 4 | L4₹25.7 L+₹3.3 L (14.9%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹25.9 L+₹3.6 L (16.0%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
1 Feb 2024, 6:00 pmClosed
GE Tirunelveli
Garrison Engineer Naval Post Base Vijayanarayanam Tirunelveli -627119
REPAIR/MAINTENANCE OF LT LINES,LT PANELS, UG CABLES AND ALLIED WORKS AT PARUNDU AND 7N DET AND REPAIR/MAINTENANCE OF INTERNAL ELECTRIFICATION,FANS, GEYSERS AT 7N DET
2024_MES_635733_1
GE/TVL/8339/E8 of 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Ramnad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Tirunelveli
₹42,000
Yes
28 Mar 2024
4 Jan 2024
3 Feb 2024
4 Jan 2024
1 Feb 2024
18 Jan 2024
5 Jan 2024 - 12 Jan 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc., removing materials for taking into credit and making good disturbed surfaces of walls, floors etc.
Point wiring with 1.5 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable FRLS-H 1100 volts grade single core drawn into and including non-metallic rigid PVC conduit of 20 mm dia/ PVC Casing capping along with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated FRLS-H 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof with and including 1.6 mm thick MS sheet fabricated terminal boxes flush mounted for mounting the switches, sockets, fan regulator etc as required with 3mm thick laminated hylum sheet top cover all as specified and directed for the following:-
(a) One light point controlled by one switch
(b) One fan point controlled by one regulator / switch.
(c)One 3 pin socket outlet 5 amps socket on independent board
(d) One 3 pin socket outlet 5 amps socket on Same board
(e) One light point controlled by two Nos of two way switches.
(f) One bell/buzzer point controlled by one push button
All as per item No. 2 here-in-before but with 4 sqmm cable for one 3 pin socket outlet 15 Amps on independent board
Supply and fix in repairs switch piano flush type single pole one way 5 A 240 Volts complete all as specified and as directed.
Supply and fix in replacement switch flush type single pole two way 5 A 240 Volts complete all as specified and as directed.
Supply and fixing in replacement Socket outlet 2 in 1, 3 pin, 5A complete all as specified and as directed.
Supply and fix in replacement switch Socket combination 2 in 1, 5 Amps Flush type 240 Volts complete all as specified and as directed.
Supply and fix in replacement switch Socket combination 5 Amps / 16 amps, 5 in 1 flush type 240 Volts complete all as specified and as directed.
Supply and fix in replacement ceiling rose 3 ways PVC / Polycarbonate, isolated body complete all as specified and as directed.
Supply and fix in replacement Call bell, ding-dong, suitable for working on 230 volts AC supply, single pole, complete all as specified and as directed.
Supply and fix in replacement Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and as directed.
Supply and fix in replacement Bell push flush type 5 A 240 Volts complete all as specified and as directed.
Supply and fix in replacement Modular switch 1 way 5A, 1 Module complete all as specified and as directed.
Supply and fix in replacement Modular switch 1 way 16A, 1 Module complete all as specified and as directed.
Supply and fix in replacement Modular bell push ,5 A, 1 Module complete all as specified and as directed.
Supply and fix in replacement Modular Socket 5A-2/3 pin combined 2 Module complete all as specified and as directed.
Supply and fix in replacement Modular Socket 5A / 15A - 2 / 3 pin combined 2 Module complete all as specified and as directed.
Supply and fix in replacement Modular fan regulator step type , 2 Module complete all as specified and as directed.
Supply and fix in replacement 3mm thick laminated sheet top cover on switch boards including cutting, fixing and screwing etc and making good the disturbed surface of wall complete all as specified and directed.
Taking down carefully old unserviceable sub main wiring with aluminum /copper conductor cable 4/6 Sqmm in PVC conduit complete removing the materials for taking into credit and making good the disturbed surface of wall / floor etc.
Material and labour for sub main wiring with two run single core 4 sqmm multi stranded copper conductor FRLS-H PVC insulated unsheathed cable 1100 volts grade and one run of 4 sq mm multi stranded copper conductor FRLS-H cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 20 mm dia/PVC casing capping 20 mm including conduit accessories all as specified and directed. Note: Three runs of 4 Sqmm cable and one run of 20mm conduit / casing capping will be measured as one unit length.
Material and labour for sub main wiring with two run single core 6 sqmm multi stranded copper conductor FRLS-H PVC insulated unsheathed cable 1100 volts grade and one run of 6 sq mm multi stranded copper conductor FRLS-H cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 32 mm dia/PVC casing capping 25 mm including conduit accessories all as specified and directed. Note: Three runs of 6 Sqmm cable and one run of 25 mm conduit / casing capping will be measured as one unit length.
Material and labour for sub main wiring with four runs single core 4 sqmm multi stranded copper conductor FRLS-H PVC insulated unsheathed cable 1100 volts grade and two runs of 4 sqmm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit, 25 mm dia/PVC casing capping 25 mm and conduit accessories concealed/surface of wall/roof/ceiling etc complete all as specified and directed. Note: Four runs of 4sqmm and two runs of 4 sqmm cable and one run of 25mm dia conduit/casing capping shall be measured as one unit length.
Material and labour for sub main wiring with four runs single core 6 sqmm multi stranded copper conductor FRLS-H PVC insulated unsheathed cable 1100 volts grade and one run of 6 sqmm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 32 mm dia/PVC casing capping 32 mm including conduit accessories all as specified and directed. Note: Five runs of 6 Sqmm cable and one run of 32 mm conduit / casing capping will be measured as one unit length.
Supply and fix in replacement Sheet metal enclosures with socket plug top and MCB SPN 20A, 240 volts, with a two pin and earth plug socket complete with one single MCB 20 Amps, 240 volts (for AC ) complete all as specified and directed.
Supply and fix in replacement sheet metal enclosure powder coated double door for Distribution Board, SPN 4 way DB ,240 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , disconnecting electric connections, dismantling from position complete all as specified and as directed.
Supply and fix in replacement sheet metal enclosure powder coated double door for Distribution Board, SPN 8 way DB with 200 A bus bar ,240 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, complete all as specified and as directed.
Supply and fix in replacement sheet metal enclosure powder coated double door for Distribution Board, TPN 4 way DB ,415 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, for taking into credit complete all as specified and as directed.
Supply and fix in replacement sheet metal enclosure powder coated double door for Distribution Board, VTPN 4 way DB with Degree of Protection IP 54 including , Disconnecting electric connections complete all as specified and as directed.
Supply and fix in replacement MCB SP 5 A to 32 A , B curve, 10 kA including , Disconnecting electric connections, complete all as specified and as directed.
Supply and fix in replacement MCB SP 40 Amps , B curve 10 kA including , Disconnecting electric connections, complete all as specified and as directed.
Supply and fix in replacement MCB SPN 32 Amps , C curve 10 kA including , Disconnecting electric connections, complete all as specified and as directed.
Supply and fix in replacement MCB SPN 40 A- 63Amps , C curve 10 kA including , Disconnecting electric connections, complete all as specified and as directed.
Supply and fix in replacement MCB TP 25A - 63 A , B curve 10 kA including , Disconnecting electric connections, complete all as specified and as directed.
Supply and fix in replacement MCB TPN 16 A- 32 Amps , B curve 10 kA including , Disconnecting electric connections, complete all as specified and as directed.
Supply and fix in replacement MCB TPN 40A- 100 A , B curve 10 kA including , Disconnecting electric connections, complete all as specified and as directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised steel earth wire 4mm dia as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 connected to earthing test point, including 20 mm GI pipe (Medium grade) for watering and 40 mm GI pipe (Medium grade) for protection of earth strip and etc.. including testing on completion ,PCC chambers in PCC1:3:6 type C1, RCC M25 type cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wire mesh ,funnel, lugs and charcoal, salt etc all as applicable including taking down old unserviceable earthing for taking into credit complete all as specified and as directed by the Engineer-in-Charge Note:-(i) The rates quoted is inclusive of 4mm dia GI wire earth conductor and protection pipe upto a length of 7.5m from the earth pit.
Supply and laying earth continuity conductor of galvanised steel earth wire 4mm dia including taking down old unserviceable GI earth wire complete all as specified and as directed.
Supply and fix in replacement MCCB 4 pole 415 volts , 100 Amps, with rupturing capacity 16 KA complete all as specified and as directed .
Material and labour for Painting the DB Boxes as required at site after scraping out completely the old paint with one coat of red oxide primer and two coats of synthetic enamel paint including carrying out minor welding works if required as directed by the Engineer in charge NOTE:Colour of paint shall be decided by the Engineer-in-charge.
Demolition of Cement concrete (unreinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for providing cement concrete 1:2:4 type B-1,85 mm thick using 20mm graded aggregate for making good the disturbed road surface after laying of pipe line over returned filled and compacted earth surface to match with existing road level complete all as specified and as directed.
Supply and fix in replacement LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed Make : Philips/GE/Jaquar
Supply and fixing in replacement LED light fitting 1x9W/1X10W bulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make : Philips/GE/Jaquar
Supply and fix in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make : Philips/GE/Jaquar
Supply and fix in replacement LED luminaries 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. Make : Philips/GE/Jaquar
Supply and fix in replacement round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make : Philips/GE/Jaquar
Taking down carefully unserviceable ceiling fans of any size from its position, dismantling blades, taking the fan motor to electrical replacement shop and bringing back the fan motor after making it serviceable & testing and hanging the ceiling fan in its position after fixing the removed blades properly and making necessary connections to ceiling rose complete all as specified and directed. Note:- Replacement of unserviceable spare parts shall be measured and paid separately under respective items of this schedule here-in-after.
All as per Sl item No 48 above but for exhaust fan of any size/model.
Material and labour for replacing Bearing Heavy Duty double ball bearing set (2 nos) with tolerance, Hardened Carbon Steel Balls with protective seal lubricated with high quality grease for smooth running for Ceiling fan complete all as specified and as directed.
Material and labour for replacing Bearing Heavy Duty double ball bearings/bush bearing set (02 nos) with tolerance, Hardened Carbon Steel Balls with protective seal lubricated with high quality grease for smooth running for exhaust fan complete all as specified and as directed.
Material and labour for replacing condenser 2.5 mfd for Ceiling fan, oil type complete all as specified and as directed.
Material and labour for replacing condenser 2.5 to 4 mfd for exhaust fan, oil type complete all as specified and as directed.
Material and labour for removing the burnt winding of ceiling fan of any size, cleaning the slot, rewinding with super enameled copper wire of suitable size, varnishing heating and insulating complete all as specified and directed by Engr-in-charge.
All as per Item No. 54, but exhaust fan of size 300mm sweep.
All as per Item No. 54 but exhaust fan of size 450mm sweep.
Material and labour for replacing shaft of ceiling fan complete all as specified and directed by Engr-in-charge.
All as per Item No. 57 but exhaust fan of size 300mm sweep.
All as per Item No. 57 but exhaust fan of size 450mm sweep.
Material and labour for replacing shackle accessories to hold with fan hook complete with rubber bush, bolt, nut, split pin complete all as specified and directed.
Supply and fix in replacement canopy suitable for ceiling fans of size 48"/56" all as per existing type and model & Colour of fan at site complete all as specified and directed.
Material and labour for replacing condenser holder/clamp PVC or metal for fixing capacitor/ condenser complete all as specified and directed.
Material and labour for painting of ceiling fan/exhaust fan of any size/make/model complete in site with synthetic enamel paint of approved colour by brush including filling cavities with fillers, one coat of after cleaning dust and rewriting the fan number etc all as directed.
Material and labour for replacing fan blade set high quality for 1200 mm sweep fan with fixing screws complete all as specified and directed..
Material and labour for replacing fan blade set made of aluminium for 300 mm sweep exhaust fan with fixing screws complete all as specified and directed.
Material and labour for replacing fan blade set made of aluminium for 450 mm sweep exhaust fan with fixing screws complete all as specified and directed.
Supply and fix in replacement louvers/mesh for exhaust fan of any size complete all as specified and directed.
Material and labour for dismantling and taking out of unserviceable geyser of any capacity/make/model, transporting to the workshop for complete over-hauling, testing of copper container, rectifying the defects including replacement of glass wool/insulating material of existing quality and returning to the site at INS Parundu, refixing and connecting up with the water connection and testing including replacement of following parts :- Note :- Replacement of spares will be measured and paid for separately under respective items of the schedule here-in-after as supply only.
Removing the door assembly and removing the deposits by scraping or cleaning the element with diluted Hydrochloric acid and flush out sediments deposited in the tank.
Supply only glass lined Incoloy 800 heating element of capacity 2 KW with rubber gasket complete all as specified and directed.
Supply only capillary type high precision thermostat (2 nos) preferably with highest safety VDE mark suitable for storage type water heater complete all as specified and directed.
Supply only non-self resetting capillary thermal cutout preferably with highest safety VDE mark suitable for storage type water heater complete all as specified and directed.
Supply only Steel (SS) braided ,Flexible Hoses (2 nos) having a minimum pressure rating of 8 bar and compatible for hot water applications including making end connections for water inlet/ outlet from/to water heater or to the discharge line complete all as specified and as directed.
Supply only Anode rod made of aluminium / magnesium .
Supply only Temperature control knob
Supply only Heating indicator lamp and power indicator lamp
Supply only drain valve.
Supply only geyser tank of capacity 25 Ltrs made out of heavy gauge stainless steel with glass enamel coating or coated complete all as specified and directed.
Supply only multifunction safety relief valve/pressure relief valve suitable for geyser complete all as specified and directed.
Supply only brass Non return valve 15 mm/20 mm dia suitable for geyser complete all as specified and directed.
Supply only Apparatus plate assembly suitable to fix thermostat, heating elements as of geyser and nuts etc complete all as specified and directed.
Supply only brass Fusible plug
Material and labour for Painting of water heater (Geyser) up to 25 Ltr capacity with synthetic enamel paint of approved colour over a coat of red oxide after removing of old paint by scraping and filling of cavities with fillers.
Supply only 3 core 4.0 Sqmm copper conductor cable suitable for geysers of any size complete all as specified and directed.
Supply and fix in replacement 3 pin plug top suitable for metal socket of capacity 25 Amps complete all as specified and directed.
Material and labour for removing the tank from the geyser, brazing to arrest the leakage, reassembling and refixing complete all as specified and directed.
Supply only in replacement Bottom inspection chamber cover suitable for 25 Ltrs capacity geyser of any make/model complete all as specified and directed.
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for laying pipes and getting out in any type of soil, complete all as specified
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified
Removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
Spreading of riddled earth obtained from trenches for cable cushioning on top and bottom of cable as specified for cable protection complete all as specified and directed. (Note: Only punned thickness of riddled earth shall be measured)
Supply and lay bricks in trenches , common burnt clay building bricks, subclass `B’ designation 75, old size ,with width equal to the length of the brick; complete all as specified and directed.
Material and labour for horizontal direction boring under road for laying 50 mm/80 mm dia GI Pipe at a depth not less than 450 mm and not exc. 800 mm complete all as specified. Note : The rate is inclusive of all the materials, equipments and labour required for doing trenchless horizontal boring under the road, nothing extra shall be admissible on any account then the rates quoted above.
Material and labour for 100 mm thick cement concrete 1:2:4 type B-1, using 20mm graded aggregate for making good the disturbed road surface after laying of pipe line over returned filled and compacted earth surface to match with existing road level complete all as specified and as directed.
Supply and lay LT under ground cable 1100 volts grade Cross linked Polyethylene (XLPE) insulated PVC Sheathed Cables: armoured multistranded heavy duty electric cable with aluminium conductor laid in trenches/ duct / walls including cable gland and lugs on both end termination including laying, connecting to various switches in panel board, testing and commissioning etc including taking out existing unserviceable cables of following sizes complete all as directed & as specified:-
(a)3.5 Core 25 Sqmm
(b)3.5 Core 35 Sqmm
(c)3.5 Core 70 Sqmm
(d)3.5 Core 95 Sqmm
(e)3.5 Core 150 Sqmm
(f)3.5 Core 240 Sqmm
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 32x6mm GI strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 connected to earthing test point, including 20 mm GI pipe (Medium grade) for watering and 40 mm GI pipe (Medium grade) for protection of earth strip and etc.. including testing on completion ,PCC chambers in PCC1:3:6 type C1, RCC M25 type cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wire mesh ,funnel, lugs and charcoal, salt etc all as applicable including taking down old unserviceable earthing complete for taking into credit all as specified and as directed by the Engineer-in-Charge Note:-(i) The rates quoted is inclusive of 32x6mm GI strip earth conductor upto a length of 7.5m from the earth pit.
Material and labour for writing letters (Block Roman, Italic or Indian) with thick paint ,stand out boldly and solidly without showing signs of brush marks, if necessary, repainted until the desired result is obtained , not exc 30 cm height and painting with contrasting colour in the background of letter complete as directed. NOTE: Colour of paint shall be decided by the Engg-in-charge.
Material and labour in replacement of GI pipe light grade of size 50mm dia for protection of UG cable on walls/under floors/road crossings/in trenches complete all as specified and as directed by the Engineer-in-Charge .
Material and labour in replacement of GI pipe light grade of size 80mm dia for protection of UG cable on walls/under floors/road crossings/in trenches complete all as specified and as directed by the Engineer-in-Charge .
Supply and fix danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size, , complete all as specified and as directed by the Engineer-in-Charge
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed .
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 100 amps, with rupturing capacity 25 KA complete all as specified and as directed .
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 160 Amps, with rupturing capacity 36 KA complete all as specified and as directed.
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 200 Amps, with rupturing capacity 36 KA complete all as specified and as directed .
Material and labour for repair of old LT panel board of any size/type incl cleaning with compressed air, tightening of all electric connections to bus bar & switchgears, re-fixing of door (front & backside) with proper fixing & replacement of butt hinges/ Lock with key, replacement of bus bar ,replacement of worn-out lugs, nut, bolts, proper connection to main earth lead, glands to be provided/replaced as required at cable entries, fixing of door front & back side with proper locking arrangement, repair to PCC foundation as required at site and spray painting with powder coated paint with smoke grey paint in outer/inner side of panel after cleaning and preparing surface complete all as directed. Note : Aluminium bus Bar shall be measured and paid under respective item.
Supply , installation, testing and commissioning of outdoor LT feeder pillar box in replacement , CPRI Approved , factory fabricated in an factory having modern fabrication and testing process which includes seven tank pre-treatment process comprising of degreasing, rinsing, de-rusting , rinsing, phosphatising, rinsing and passivation followed by powder coat painting having thickness not less than 100 microns .The bus bar chamber comprising of high conductivity aluminium bus bar of capacity 400 Amps three phase and half the capacity for neutral. The doors shall be provided with suitable gasket and latch including PCC foundation for erecting the panel board. Feeder pillar shall be suitable to accommodate the following as specified and as directed.:- OUTER SHELL : The outer shall be made out of 3.15 mm thick CRCA sheet &MS angle section 50x50x6 mm frame, factory fabricated with front & back open able, double door system lockable/open able by keys from both sides having chromium plated locks. ‘U’ type gasket shall be used to make the outer shell completely vermin proof. The bottom of the outer shell contains a detachable plate of thickness 3.15 mm powder coated having provision for entry of armoured cable of adequate size with glands. The outer shell shall be powder coated Siemens grey structural RAL 7032 shade.
INNER SHELL : inner shell shall be made out of 2.0 mm thick CRCA sheet duly compartmentalized for each control gear, front & back open able single door system lockable / open able by keys from both sides having chromium plated locks (2 Nos in each compartment),having louvers & air vent gasket for natural flow of air. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size ‘F’ class insulator made on non hygroscopic, non combustible , track resistant, high strength FRP/SMC/DMC material at an interval not more than 500mm throughout the length of the TPN bus bar. INCOMING (a) MCCB 415 V,250 A, 4 pole breaking capacity 25 KA- 01 Nos. (b) Change over switch 250 A - 01 Nos. (c) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard practice ---1 Job OUT GOING (a) MCCB 160 A, 415V , 4 pole , breaking capacity 25 KA - 01 Nos (b) MCCB 100 A, 415V ,4 pole , breaking capacity 16 KA - 02 Nos (c) MCCB 63 A, 415V ,4 pole , breaking capacity 16 KA - 03 Nos (d) MCB 40A, 415V , TPN , 10kA C Curve - 03 Nos (e) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard practice ---6 Job
Supply and fix in replacement ON Load Change over switch 415V 4 pole 160 Amps in sheet metal enclosures with cable gland, auxiliary switch and spreader links as applicable to frame size complete all as specified and directed.
Dismantling & taking out LT burnt cable ends of any size from transformer/LT panel/LT feeder pillar box/trenches any type/size, for repair/making suitable for reconnection to cable, providing lugs to burnt end of cables, preparing fresh terminals and reconnection, fixing the removed portion of cable with transformer/in trenches/along pole/ panel/feeder pillar box, including excavation of loop & refilling complete using old bricks and sand returning filling the excavated soil complete
Material and labour for cable route indicator 150mm dia 3mm thick made out of cast aluminum duly marked with size and type of cable fixed on 40x40x6mm angle iron support embedded in PCC 1;2:4 type B1 using 20 mm graded (300x300x400mm size) and painted with 2 coats of anticorrosive paint over a coat of red oxide primer all as specified and as directed.
Material and labour for De-hydration/ filtration of transformer oil by employing on line filtration plant to achieve di-electric strength not less than minimum 50 KV including following work services :- (a) Removal of all suspended particles such as dust, rust, scales, collided Carbon oxidation sludge, etc upto < 1 micron. (b) De-hydration of transformer oil under vacuum. (c) Circulation of heated oil and filling of treated oil in transformer tank. (d) Top up the transformer oil upto the level NOTE : (i) Contractor shall use the vehicle mounted filtration plant with new suitable size heavy duty hose pipe. (ii) The transformer oil required for replacing/top up shall be measured and paid separately . (iii) Conducting field testing of di-electric strength of the transformer oil before and after filtration
Material and Labour for topping up transformer oil in transformer complete all as specified and directed.. Note : Sealed container only will be brought at site with minimum BDV 60 KV
Material and labour for disconnecting HT/LT connection of transformer, 11000/433 V, 3 Phase, 4 wire system and opening up the top cover of transformer of capacity 200 KVA for checking the conditions to carryout replacements at site, including draining out oil from the transformer in suitable container (containers to be provided by the contractor) and replacement to the transformer with replacement of parts (as required), checking the lead connection from winding to bus rods including necessary soldering/jointing etc and after complete replacement refilling the dehydrated oil, replacing perished gasket with new gasket of same size and testing on full load after connecting the HT/LT connections complete all as directed by Engineering charge Notes : (i) Major parts as under shall be measured and paid separately under appropriate item of this BOQ (iii) Dehydration/ filtration of transformer oil shall be measured and paid separately under relevant item of this BOQ’ (iv) T&P and minor parts will be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item (v) Rate deemed to be inclusive of securing the cables on HT/ LT side for tension free at cable entry box.
Material and Labour for Replacement of HT bushing of transformer 11/0.433 KV of capacity 200 KVA complete all as specified and directed
Material and Labour Replacement of LT bushing of transformer 11/0.433 KV of capacity 200 KVA complete all as specified and directed.
Material and Labour for Replacement of silica gel breather of 11000/433 V transformer of capacity 200 KVA complete all as specified and directed.
Material and Labour for Replacement of silica gel standard type complete all as specified and directed.
Material and Labour for painting of transformer 11000/433 V, 3 Phase, 4 wire system of capacity 200 KVA with one coats with synthetic enamel grey colour paint with spray gun complete incl surface preparation complete all as specified and directed
Material and Labour for replacement of Single Post insulator, 11 KV with hardware fittings etc. complete all as specified and directed by Engr-in-charge.
Supply and Fixing for replacement of 11 KV Lightning Arresters expulsion type complete with all fittings, transmission class discharge capacity 65 kilo Amps etc as required testing and commissioning complete all as directed Engineer-in-Charge.
Material and Labour for replacement of ACSR Conductor of weasel type for HT connection complete all as specified and directed.
Material and labour for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm complete all as specified and directed.
Material and labour for preparation of old painted surfaces of HT 4 pole structure, channels and clamps, section size up to 100x50 mm, clamps etc and applying one coat of zinc chromium primer and 2 coats of aluminium paint for cross arms any numbers of each pole incl clamps etc all as specified and directed.
Supply and laying, testing and commissioning HT 11KV XLPE cable, PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), cable of size 3 core 185 sqmm laid in trenches / floor / duct / fixed on poles / through GI tubing including brass cable glands complete all as specified and directed.
Supply and fixing for replacement of cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 185 sqmm x 3 core complete all as specified and directed.
Supply and fixing for replacement of cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 185 sqmm x 3 core complete all as specified and directed.
Supply and fixing for replacement of cable jointing kit for 11 KV (Earthed) grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 185 sqmm x 3 core including taking down old item, complete all as specified and directed.
Supply and fix for replacement of MCCB four pole 415 volts 63 Amps, with rupturing capacity 16 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge . .
Material and labour for servicing High mast light control gear suspension system with stainless steel wire rope guage and double drum winch with luminaries mounting arm, pulley assembly, complete all as specified and directed.
Supply and fixing in replacements LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including all accessories complete all as specified and as directed.
Supply , erection, testing of maintenance free chemical earthing by auguring & installation of copper bonded rod using machine bore and filling with backfill compound using copper bonded rod of dia 20 mm , length 3m , made of low carbon high tensile steel with copper plated (250+ microns) for preventing external corrosion, with top end connected with copper plated welded bus bar terminal of dimension 150mm x 50mm x 6 mm , complete conforms to IS : 3043 - 1987 and carbon based, high conductive backfill compound 'Conductolite' with resistivity < 0.5 ohm-metre (In dry conditions) & resistivity is non-moisture dependant,pH Value : 8.0 - 9.0, electronic & ionic conduction, less susceptible to shrinkage, with hygroscopic & corrosion resistive properties and covering with heavy duty polyplastic earth pit chamber cover . Make : M/s Ashlok Safe Earthing Electrode Limited or equivalent as approved by GE.
Material and labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified
Material and labour for expulsion type single pole drop out fuse assembly HT 11 kV, 50 - 100 Amps including dismantling the unserviceable item complete all as specified
Material and labour for Air break gang operated switch, Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for 11 kV, current rating upto 200 amps complete all as specified and directed.
Dismantling of ACSR Conductor complete all as specified and directed.
SRI LAKSHMI GANESH ENGINEERING WORKS
VVM CONSTRUCTIONS
AISWARYA ENTERPRISES
THIRUMURUGAN ENTERPRISES
sri manikandan enterprises
SIVA MARUTHI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .