Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹27.3 LAccepted-AOC NO 3 JAMI JAM KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | 1 | Accepted-AOC BEING LOWEST TENDERER AND FULFILLING ALL THE REQUISITE CRITERIA | |
| 2 | 2₹32.1 L+₹4.8 L (17.4%)Rejected-Finance OLD NO 338 NEW NO 17 19TH NEDUMANEHLIAN STREET G K M COLONY CHENNAI 600 082 | CHENNAI | CHENNAI | TAMIL NADU | 600082 | 2 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 3 | 3₹32.6 L+₹5.3 L (19.3%)Rejected-Finance NO 2C THANGAVEL VAITHIYAR STREET TRIPLICANE CHENNAI 600 005 | CHENNAI | CHENNAI | TAMIL NADU | 600005 | 3 | Rejected-Finance NOT BEING LOWEST TENDERER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
24 Jan 2024, 6:55 pmClosed
GE
GE CHENNAI FORT ST GEORGE CHENNAI-9
REPAIRS TO ROOF, WALL, SEEPAGE, GALVALUME SHEET ROOF, PLASTERING, BRICK WALL IN AOR OF AGE B/R-I UNDER GE CHENNAI
2023_MES_634304_1
8717
Open Tender
Civil Works
Item Rate
183 days
chennai
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE CHENNAI
₹80,000
Yes
2 Mar 2024
23 Dec 2023
31 Jan 2024
23 Dec 2023
24 Jan 2024
10 Jan 2024
Amount
Dismantling of Plain or corrugated steel sheeting,any gauge, thickness, includingNainital or similar pattern roofcoverings
Excavating in post holes (or similar holes) each n exc 0.5cu m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard/dense soil complete all as specified and directed.
Dismantling of wall and ceiling boards ( fibre pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
M&L for flyash brick work with sub class B bricks straight or curved on plan exc 6M mean radius built in CM 1:4
Taking down cement plaster on brick work or stone walls etc including racking out of joint , hacking for key scrubbing down with water etc
M&L for rendering 15mm thick on fair faces of brick work in two layers, first layer 10mm thick in CM 1:6 and second finishing coat 5mm thick in CM 1:4 mixed with water proofing compound as per manufacturers instructions and finished even and fair on external surfaces.
M&L Rendering in CM 1:3, 10 mm thick as in ceiling on fair faces of concrete surfaces including finished even and fair in patches all as specified and as directed.
M & L for applying three coat of white wash as in ceiling incl preparation of newly plastered ceiling surfaces all as specified and as directed.
Material and labour for applying two or more coats of 100% premium acrylic mulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete including preparation of newly plastered /treated surfaces of walls all as specified and as directed by the Engineer-in-Charge.Make : APEX of Asian or equivalent of shalimar / Nerolac/ Berger.
S&F in repairs 20 mm bore Ball valves highpressure of PTMT withepoxy coatedAluminium rod &highdensity plastic ballscrewed for iron pipeand fixed. (Minimumweight 2 0 m m - 2 1 0 g m s) .
S&F in repairs 25 mm bore Ball valves highpressure of PTMT withepoxy coatedAluminium rod &highdensity plastic ballscrewed for iron pipeand fixed. (Minimumweight 2 5 m m - 455 g m s .)
M&L forPreparing the surface thoroughly by cleaning, washing and removing dust, dirt, oil, grease and loose particles.In existing old terraces with brickbat coba or screeds, damaged or hollow portions, sharp edges, etc. and demolishing/dismantling/taking down and removing existing finishes of any type over existing roof slab till the mother slab is exposed and washing down with clean water to remove all dirt etc. The slab should be recoated with slurry of Dr. Fixit Pidicrete URP or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP and cement in 1:1 proportion. After drying, the surface cracks must be filled with Dr. Fixit. Crack-X or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP or polymer-modified mortar in case cracks are wider than 5 mm.Cracks less than 2 mm, should be cleaned free of dust with a vacuum cleaner. Apply Dr. Fixit Primeseal or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP in the crack and let it dry. Then pour Dr. Fixit Newcoat or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP into these cracks and waitfor it to dry.Bitumen based waterproofing treatments if existing, must be completely removed by mechanical scarification or by any other effective mechanical means and Dilute 2 parts of Dr. Fixit Primeseal or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP with 1 one part of water. This dilution shall cover 7 to 8 sq.mt. Allow it to dry for6 to 8 hrs.Apply the first coat of Dr. Fixit Newcoat or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP without any dilution at the rate of 2 sq mt per litre and allow it to dry before taking up the second and third coats, the rate of application being the same. and open woven glass fibre mesh of 2.5 mm x 2.5 mm must be sandwiched between the first and second coat. While the 1st coat is still wet, place the fibre mesh on it. After the coat dries, start applying the 2nd coat of Dr. Fixit Newcoat or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP .
This reinforcement with fibre mesh shall be extended up to the drip mould over the angle fillets. Drying time between coats will be 6 to 8 hrs. Allow the system to air cure for 7 days minimum. A total thickness of 1 to 1.2 mm must be achieved when Newcoat is dry. The thickness of coat shall be got verified in the presence of Engineer in charge and recorded building wise in abound register and submitted alongwith claims for payment. Note: All above treatment will be measured as one unit of square metre and paid accordingly.
M&L for Preparation of new wall Surface for treatment by thoroughly cleaning of dirt etc. by washing down. Priming saturated surface dry condition using Dr. Fixit Primeseal or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP diluted in 2:1 ratio with water (2parts Primeseal diluted with 1 part water) @ 8-10 sq mtr per litre for a single coat application to achieve about 20 – 25 microns DFT. Allow it to dry for 6-8 hrs. Apply one coats of Dr. Fixit Raincoat Waterproof Coating or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP without dilution by brush or roller for at the thickness of 120 – 130 microns all as specified and directed . Note: All above treatment will be measured as one unit of square metre and paid accordingly.
M&L for Preparation of Existing surfaces to remove all dirt, mildew and other contaminants. Treat areas affected by Algae, moss or fungal growth with biocide wash solution and pressure cleaning equipment with a minimum capability of 100-140 bar water pressure. All grease, oils and asphalt materials must be removed completely.. All surface cracks up to 5 mm width should be filled up with Dr. Fixit Crack-X or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP.Cracks more than 5 mm and all separation gaps should be filled up with Dr. Fixit Pidicrete URP modifiedmortaror its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP. Priming using Dr. Fixit Primeseal or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP diluted in 2:1 ratio with water (2parts Primeseal diluted with 1 part water) @ 8-10 sq mtr per litre for a single coat application to achieve about 20 – 25 microns DFT. Allow it to dry for 6-8 hrs. Apply one coats of Dr. Fixit Raincoat Waterproof Coating or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP without dilution by brush or roller for walls at the thickness of 120 – 130 microns all as specified and directed . Note: All above treatment will be measured as one unit of square metre and paid accordingly.
M&L for aplly a tack coat coat of bitumen 85 /25 at the rate of 1.20 Kg /Sqm on roof surfaces including cleaning of surfaces in patches including sealing the open joints in the water proof felt including one coat solar reflective aluminium painting @ 0.10 Litre per sqm on repaired portion complete all as as specified and directed
M&L for PCC 1:2:4 type B1 (using 20mm graded aggregate) in copings, kerbs, channels, water through and the like including weathering, slightly rounded or chamfered angles and throating etc complete all as specified and as directed.
S&F pre- painted galvatume aluminum zinc coating GI based corrugated steelsheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Dismantling of wrought iron or mild steel work of any description not otherwise provided for all as specified and directed by Engr-in-charge
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running railsand guides for sliding doors; fixed with angle cleats or other connecting plates Fe-410- W(Gde- E-250) quality-B all as specified and as directed
M&L for applying two coats of synthetic enamelled paint over a coat of red oxide on steel or iron surface based materials of any description , not other wise described over 10 cm width or girth including preparation of new surfaces.
S&F for Framed brackets of angles or tees with web and flanges cut toshape, drilled and countersunk for screw, including bending andwelding angles, as necessary, gusset plates, riveting, etc.. n exc10 kg each brackets, conforming to Fe.290.Gde-E-165 (Bracketsover 10 kg each to be measured under 'Structural Steel')all as specified and as directed
S&F for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. Fe-410- W(Gde- E-250) quality- B(cut to ordinary lengths i.e. Within 20mm of the length indicated) all as specified and directed.
Preparation of new steel surfaces and appying two coats of black bituminous paint all as specified and directed.
Cutting holes into or through brick walls but in brick walls superficial area n.exc 150sqcm built, in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete. and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required
Cutting holes into or through brick walls built in but in brick walls area exc 150 sqcm but n.exc 400 sqcm built in lime mortar and stone walls and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required
Complete removal of existing roof treatment any type including vegetation, plants etc and demolition of cement concrete padding at roof slab n exc 15cm thickness all specified and directed by Engr-in-Charge
M & L for plain cement concrete 40mm thick average thickness as roof padding type B0, 1:2:4 (12.5mm graded aggregate) finished fair and even over concrete surface on roof top, and finished even and smooth with 10mm thick cement plaster in CM 1:4 mixed with WPC @ 200 ml per bag, when the concrete is green all as per manufacturer instructions ( Note: Water proofing compound will be paid under measured seperately)
Supply only Liquid water proofing compoud
Cleaning and preparation of newly plasteres roof surfaces and applying the water proofing treatment as under. (a) Applying 1st course of bituminious (oil based) primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed. (b) Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm. (c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlap and 100 mm overlap by forced / torch application as per manufactures instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane, (e) Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on roof surfaces complete all as specified and directed. Note: All above treatment will be measured as one unit of square metre and paid accordingly.
Note: All above treatment will be measured as one unit of square metre and paid accordingly.
Taking down of existing cement or lime plaster alongwith the existing water proofing treatment on walls and applying 10 mm thick cement plaster 1:3 mixed with liquid Water Proofing Compound @ 200 ml per bag, cleaning and preparation of newly plastered wall surfaces and applying the water proofing treatment as under. (a) Applying 1st course of bituminious (oil based) primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed. (b) Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm. (c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlap and 100 mm overlap by forced / torch application as per manufactures instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane, (e) Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on wall surfaces complete all as specified and directed.
Note: All above treatment will be measured as one unit of square metre and paid accordingly.
M & L for galvanised powder coated snap grid framework of size 605 x 605mm for false ceiling all as specified including vinyl laminated MPL gypsum panels ( GYPTECH) 9mm thick of size 60 x 60 cm fixing with stapples on snap grid by means of GI wires not less than 4mm dia hooks and raw plug etc centre of amke. GYPTECH/ARMSTRONG or equivalent all as directed by Engr-in-Charge
M&L PCC Type B2 (1:2:4) using 40mm graded stone aggregates as in foundation, filling and mass concrete
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
Disconnecting existingtanks, setting aside (orlowering if required) for repairs, cleaning, etc. andCleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. Capacity exc 250ltrs but n.exc 500ltrs complete all as specified and directed.
All as per item 36 above but For exc 500 lt and not exc 1000 lt capacity
All as per item 36 above but For exc 1000 lt and not exc 2000 lt capacty
S&F Galvanised steel water tubing medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed to walls/ceilings or laid in floors etc., complete including taking up (or) down the existing GI pipe completely all as specified for 15mm bore pipes.
All as per item no 39 above but 20mm bore pipes
All as per item no 39 above but 25mm bore pipes
Refixing only Galvanised steel water tubing medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed to walls/ceilings or laid in floors etc., complete including taking up (or) down the existing GI pipe completely all as specified for f15mm bore of pipes.
All as per item no 42 above but 20mm bore pipes
All as per item no 42 above but 25mm bore pipes
M & L Gun metal globe or gate valve with iron wheel head screwd both ends for iron pipe and fixed for 25 mm dia bore pipes fixed in repairs
M & L Gun metal globe or gate valve with iron wheel head screwd both ends for iron pipe and fixed for 20 mm dia bore pipes fixed in repairs
S&F Rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position capacity of tank 1000 ltrs including dismantling of existing tank of any description and S&F 20 mm ball PTMT Ball valve high pressure with exposy coated aluminum rod and high density plastic ball screwed for iron pipe.
S&F Rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position capacity of tank 500 ltrs including dismantling of existing tank of any description and S&F 20 mm ball PTMT Ball valve high pressure with exposy coated aluminum rod and high density plastic ball screwed for iron pipe.
S&F Rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position capacity of tank 2000 ltrs including dismantling of existing tank of any description and S&F 20 mm ball PTMT Ball valve high pressure with exposy coated aluminum rod and high density plastic ball screwed for iron pipe.
PVC (SWR) pipes 110mm single socketed , in any length with rubber ring joints ,fixed to walls /floor ,spouts etc complete including dismantling existing pipes of any description all as specified and directed.
PVC (SWR) bends with oval access door 110mm fixed in repairs complete all as specified and directed.
GK ENTERPRISES
M/SJAYAM CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .