Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAccepted-AOC 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L1 | Accepted-AOC Being overall rate reasonable | |
| 2 | L2₹41.9 L+₹1.5 L (3.81%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹42.2 L+₹1.8 L (4.57%)Rejected-Finance SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹43.5 L+₹3.2 L (7.84%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹44.0 L+₹3.6 L (9.01%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
1 Dec 2021, 6:00 pmClosed
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE-411003
REPAIR REPLACEMENT TO EXTERNAL WATER SUPPLY SYSTEM WITH REPLACEMENT OF OLD PIPES VALVES REPAIR TO WALL PITS REPAIR OF PUMP SETS AND FOUNDATION UNDER AGE EM II IN GE C KIRKEE
2021_MES_485932_1
8534/E8 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE CENTRAL KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹80,000
Yes
18 Jan 2022
2 Nov 2021
6 Dec 2021
2 Nov 2021
1 Dec 2021
17 Nov 2021
2 Nov 2021 - 16 Nov 2021
Amount
Material & Labour for Excavation in trenches not exceding 1.5 m wide not exceding 1.5 m in depth and getting out Hard/dense soil for taking down or laying of water pipe line complete all as specified and as directed by Engineer in Charge.
Material & Labour for Returning filling in, including spreading, leveling watering well ramming in layer n.exc 1.5 cm thick in soft/loose soil complete all as specified and as directed by Engineer in Charge.
Material & Labour for Removal of excavating material n.exc 50m & deposited where directed and n.exc 1.5m above the starting point complete all as specified and as directed by Engineer in Charge.
Material & Labour for chemical testing of water sample at 4 months interval at any Govt recognised water testing lab for the following parameters : Turbidity, PH, Total Hardness, Alkalinity, Chloride, Nitrate, TDS, Iron, Fluorides, calcium, Magnesium, Aluminium, Sulphide, Lead, Arsenic, Manganese, Copper, Mercury, residual chlorine etc as per IS standards complete all as specified and as directed by Engineer in Charge. Note: i) Sample of water to be collected from River Side pump house in sterilised bottle provided by the lab. (ii) Contractor should provide all arrangment for collection of sample as per the specifications of testing lab and will submit report (in Triplicate) to Engineer in Charge. (iii) Test shuld be carried out in scheduled time as specified by Engineer in Charge , otherwise recovery shall be effected thrice the quoted rate. (iv) All parameters of testing shall be considered as one Job. (v) Rate quoted by the contractor is deemed to be inclusive of testing charges of lab, cost of materials required, cost of trasportation and report etc
Supply and laying GI tubes, medium grade, 50mm dia, in trenches/wall /floor with all fittings complete all as specified and as directed by Engineer in Charge.
All as item No- 5.00 above but of size 40mm bore.
All as item No- 5.00 above but of size 25mm bore.
All as item no-5.00 above but of size 20mm bore.
All as item no-5.00 above but of size 15mm bore.
Supply & Fix Gun metal gate valve, cast copper alloy, screwed down, high pressure with iron wheel handle, screwed both ends for iron pipe or unions of size 50mm dia including taking down old gate valve complete all as specified and as directed by Engineer in Charge.
All as item no-10.00 above but of size 40mm bore.
All as item no-10.00 above but of size 25mm bore.
All as item no-10.00 above but of size 20mm bore.
All as item no-10.00 above but of size 15mm bore.
Material & Labour for disconnecting and taking down carefully Electric driven pumping set of capacity 10/15HP (motor and pump) from foundation, disconnecting suction and discharge water line for carrying out repair work of pump set, dismantling of pump set, cleaning, repair replacement of all unserviceable parts, reassembling complete pumping set, reinstalling , mounting and fixing on base channel on existing foundation and coupling properly to existing motor with proper balancing and alingment including recoupling of suction and discharge line, testing on full load for smooth functioning complete all as specified and as directed by Engineer in Charge.
Note: (i) Rate quoted by contractor is deemed to be inclusive of minor spares like gland, grease, nut bolts and major spares required for work shall be measured and paid separately and rate quoted shall be deemed to be inclusive of fixing charges of major new spares under this item. (ii) Contractor should visit site before quoting the rates. (iii) Cost of transportation shall be deemed to be included in the rate quoted for these items. (iv) While taking out pump for repairs , the contractor shall make arrangement for pluging suction and discharge line with dead flanges without extra cost, so that pumping of installation is not disturbed and there is no leakage of water. (v) The contractor shall repair and refix the pump set within three working days from the date of opening and making it functionable.
All as per item No.15.00 above but of capacity 30HP complete all as specified and directed.
All as per item No.15.00 above but of capacity 60HP complete all as specified and directed.
All as per item No.15.00 above but of capacity 75HP complete all as specified and directed.
Supply only following spare/parts of pump set for incorporation in the Item Ser No 15.00 to 18.00 above complete all as specified and as directed by Engineer in Charge :-
Pressure gauge 0-30 PSI with 15mm valve & connector
MS shaft for pump of capacity 60 HP
Impeller MS/CI suitable for pump of capacity 60 HP
MS geard coupling with suitable size of key for pump of capacity 60 HP
Gasket set suitable for pump of capacity 60 HP
Gland bush (shaft sleeves) suitable for pump of capacity 60 HP
Gland Plates suitable for pump of capacity 60 HP
Brass Distance bush suitable for pump of capacity 60 HP
MS shaft suitable for pump of capacity 15 to 30 HP
Impeller bush brass suitable for pump of capacity 15 to 30 HP
Impeller MS/CI suitable for pump of capacity 15 to 30 HP
Coupling (As per sample) suitable for pump of capacity 15 to 30 HP
Gasket set suitable for pump of capacity 15 to 30 HP
Gland plates MS (As per sample) suitable for pump of capacity 15 to 30 HP
Gland bush / Shaft sleeve (As per sample) suitable for pump of capacity 15 to 30 HP
MS shaft suitable for pump of capacity 75 HP
Impeller bush brass suitable for pump of capacity 75 HP
Brass Impeller suitable for pump of capacity 75 HP
Gasket set suitable for pump of capacity 75 HP
Gland bush / Shaft sleeve (As per sample) suitable for pump of capacity 75 HP
MS Coupling suitable for pump of capacity 75 HP
Bearing No. NU-308/309/310/313 for electric motor & pump
Bearing No. 6313/6310/6314 for electric motor & pump
Bearing No. 3309 for electric motor & pump
Material & Labour for demolition of old foundation and construction of PCC foundation for pump set of 60 HP Capacity using PCC 1:2:4 (Type B-1) as per requirement with and including foundation bolts/stud grouted in the PCC all as directed by Engr-in-Charge at site, including replacement of old rusted chassie/MS foundation as per existing size, commissioning and installation of pump set with proper allignment for smooth functioning complete all as specified and as directed by Engineer in Charge.
Note for Item No 20 above :- (i) Rate quoted by the contractor shall be inclusive of material and labour required for disconnecting and reconnecting electric connection, suction and delevery pipe line of pump set etc. (ii) While taking out pump set, contractor shall make arrangement for pluging suction and discharge line with dead flanges without extra cost, so that pumping of installation is not disturbed and there is no leakage of water. (iii) Contractor should visit site before quoting the rate.
Material & Labour for disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding, taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire of same guage/size to get the same output of motor with and including material such as varnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing complete all as specified and directed by Engineer in Charge of capacity 15 HP.
All as per item No 21.00 above but of capacity 30 HP
All as per item No 21.00 above but of capacity 60 HP
All as per item No 21.00 above but of capacity 75 HP
Material & Labour for cleaning/overhauling of Cooling tower including taking down fan motor, cleaning fan, cleaning of cooling tower internally and externally, painting complete, replacement of honey comb complete all as specified and as directed by Engineer-in-Charge. Note:- (i) Quoted rate is deemed to be inclusive of the cost of painting of complete cooling tower internally and externally with two coats of epoxy paint over a coat of primer as directed by Engr-in-Charge. (ii) Contractor should visit site before quoting the rate.
Material and Labour for Dismantling existing control & power wiring of LT starter Panel of pump motor of capcity 15 HP to 75 HP & rewiring with PVC insulated copper wire of existing size of control & power wiring for proper sequential working of contactors with delay timer, over load relay of water pumps, cooling tower motor, mccb etc. by making proper connections to contactors, relays, fuses, switches, voltmeter, ammeter including Repair/Replacement of damaged hinges of each compartment of panel, taking down existing bus bars and cleaning with CTC applying with becktol red solution, providing bus bar insulation and refixing with new nuts, bolts, washers etc including testing and commissioning complete all as specified and as directed by Engineer in Charge. Note:- (i) Cost of electric cable, lugs & connectors etc required for the work is deemed to be included in the Rate quoted by the Contractor. (ii) The quoted rate is deemed to be inclusive of the cost of painting the panel with two coats of synthetic enamel paints over a coat of primer complete all as specified and as directed by Engineer in Charge. (iii) MCCB, Contactors ,Relay meters etc required for the job shall be measured and paid separately under relevant items of this schedule.
Material & Labour for Attending Complaints by deploying sufficient labours for rectification of leakage of water pipe lines of size 250 to 350 mm Bore pipe of any description such as CI/DI/GI pipe line at any location under AGE E/M-II including necessary excavation, earth work, dewatering, including repairs with suitable flanges, rubber packing, lead wool or any other packing material complete all as specified and as directed by Engineer in Charge.
All as per Item No 27.00 above but of size 100 to 200mm bore.
All as per Item No 27.00 above but of size 50 to 80mm bore.
Note for item No 27.00 to 29.00 :- i) Complaint will be notified to contractor on mobile phone at any time between 0800 hrs to 2200 hrs and contractor shall rectify the complaints within 24 hours after notification, failing which Rs 500/- per day per complaint shall be deducted from the payment due to the Contractor. ii) Contractor shall visit the site before quoting the tender iii) Any misc items required for completing the job are deemed to be included in the rate quoted by contractor. iv) Pipes, valves, GI Fittings and mechenical joints needed for work shall be mesured and paid under relavant items of schedule.
Supply & Fix Cast Iron Non return valve suitable for 150 mm bore pipe with bypass arrangement, Double flanged swing type as per IS-5312 (Part I) of pressure rating PN 1.6, with and including gasket, nutbolts and washer etc and dismantling/ removal of Unsv NRV complete all as specified and directed by Engineer in Charge.
Supply & Fix Cast Iron Sluice Valve of size 300mm dia with flanged ends drilled of class PN 1.6 with SS spindle complete with rubber gasket 6mm thick ,nuts bolts and washers etc complete including taking out old unserviceable sluice valve complete all as specified and as directed by Engineer in Charge.
Supply & Fix Cast Iron Sluice Valve of size 200mm dia with flanged ends drilled of class PN 1.6 with SS spindle complete with rubber gasket 6mm thick, nuts, bolts and washers etc complete including taking out old unserviceable sluice valve complete all as specified and as directed by Engineer in Charge.
Supply & Fix Cast Iron Sluice Valve of size 150mm dia with flanged ends drilled of class PN 1.6 with SS spindle complete with rubber gasket 6mm thick, nuts, bolts and washers etc complete including taking out old unserviceable sluice valve complete all as specified and as directed by Engineer in Charge.
Supply & Fix cast iron foot valve of size 200 mm dia with flanged end including rubber gaskits , nut bolts,and washers etc complete including taking out old unserviceable foot valve complete all as specified and as directed by Engineer in Charge.
Supply & Fix cast iron foot valve of size 150 mm dia with flanged end including rubber gaskits , nut bolts,and washers etc complete including taking out old unserviceable foot valve complete all as specified and as directed by Engineer in Charge.
Supply & Fix cast iron air valve of size 50 to 100 mm dia with flanged end including rubber gaskets, nut bolts,and washers etc complete including taking out old unserviceable air valve complete all as specified and as directed by Engineer in Charge.
Supply & Fix Non return valve CI, 100mm dia with bypass arrangement and GI pipe 20mm dia and gate valve etc , Double flanged swing type as per IS-5312 (Part I) of pressure rating PN 1.6, single Door type including removal of old gasket , nut bolts etc & removal of unserviceable NRV complete all as specified and as directed by Engineer in Charge.
Supply & Fix in replacement cast iron Foot valve of size 150mm dia, conforming to IS 4038, complete all as specified and directed by Engineer in Charge.
Supply & Fix in replacement cast iron Foot valve of size 200mm dia, conforming to IS 4038, complete all as specified and directed by Engineer in Charge.
Supply & Fix CI/MS fittings such as collar ,bends, tail piece, of size 100 to 300 mm dia including gasket, nutbolts, handle etc & including removal of Unsv fittings complete all as specified and directed by Engr-in-Charge.
Material & Labour for Construction of masonry valve chamber of 1200mm x 1200mm x 1200mm size ,100 mm thick foundation using PCC 1:4:8, type D-2, over 15cm thick hard core, 20cm thick solid block masonry with blocks cast using PCC 1:3:6, type C-1, set in cement mortar 1:4, 15MM thick plaster to internal surfaces and external surfaces up to 15cm below ground level and top of floor in cement and sand mortar 1:4, finished even and smooth with out using extra cement , 3.15mm thick MS sheet cover including 50mmX50mmX6mm thick MS angle frame fixed in PCC 1:2:4, type B1 coping with 25mmX6mm flat iron hold fasts, handle, hinges with locking arrangements, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of surplus soil to a distance not exceeding 50M complete all as directed and as specified by Engineer in Charge.
Surface Excavation n. exc. 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed by Engineer in Charge.
Material & Labour for providing hardcore of gauge n. exc 63mm, deposited, spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engineer in Charge.
Material & Labour for coloured machine pressed precast concrete interlocking paver block glossy finish (Two colour combination ) any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 grade with grey cement and pigment laid over sand cuhsion complete all as specified and as directed by Engineer in Charge.
Dismantling of stone sett paving laid bedded and pointed in cement mortar of any description or thickness complete all as specified and directed by Engineer in Charge.
Demolition of cement concrete in ground floors and paving n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer in Charge.
Material & Labour for PCC 1:4:8 Type D-2 ( using 40 mm graded agg) 100 mm thick, as in sub base for stone sett paving finished even and fair complete all as specified and directed by Engineer in Charge.
Material & Labour for stone sett flooring with stone setts of size 200 to 150 mm long ,150 to 200 mm wide and 150 mm deep and sides dressed, bedded in cement mortar 1:3 joints 20 mm thick ; grouted in cement mortar 1:2 with an admixture of metallic floor harder 5% by weight of cement and struck flush complete all as specified and directed by Engr-in-Charge.
All as item no 48.00 above but except stone complete all as specified and directed by Engr-in-Charge.
Material & Labour for flush pointing 20mm thich to stone sett paving any decription in cement mortar 1:3 with an admixture of metallic floor harder 5% by weight of cement complete all as specified an directed by Engineer in Charge.
Removal of debris (concrete, broken stone etc.) to location as directed (distance exceeding 1.5 KM but 5KM from the site ) an depositing where directed complete all as specified an directed by Engineer in Charge.
Material & Labour For Cutting existing CI/DI/MS pipe of 100 to 350 mm dia for inserting of CI/MS/DI fitting / Mecanical joint of existing size and making good the work space complete all as specified and as directed by Engr-in-Charge. Note :- The cost of pipe cutter and Tools & Plant required for the work shall be deemed to be included in the rate quoted by contractor.
Supply and fixing for Mechanical joint collar coupling long sleeve with rubber washer, mild steel screw bolts (machine made) with both ends screwed of dia as per flange hole and required length, each screwed end to be fitted with washers and hexagonal nut suitable for 100mm CI/DI/MS pipe complete all as specified and as directed by Engineer in Charge.
All as per item no-53.00 above but of size 200mm bore.
All as per item no-53.00 above but of size 300mm bore.
All as per item no-53.00 above but of size 350mm bore.
Supply & fixing of MCCB 250 Amps 36KA, 4 Pole with Adjustable thermal magnetic release with and including suitable rotary handle,spreader links etc in the control panels complete all as specified and as directed by Engineer in Charge. Make :- Legrand/Schinder/L&T as approved by GE.
Supply & fixing of MCCB 400 Amps 36KA, 4 Pole with Adjustable thermal magnetic release with and including suitable rotary handle,spreader links etc in the control panels complete all as specified and as directed by Engineer in Charge. Make :- Legrand/Schinder/L&T as approved by GE.
Supply & fixing of MCCB 630 Amps 36KA, 4 Pole with Adjustable thermal magnetic release with and including suitable rotary handle,spreader links etc in the control panels complete all as specified and as directed by Engineer in Charge. Make :- Legrand/Schinder/L&T as approved by GE.
Supply & Fixing of Gate Light fittings, decorative type, LED 40 Watt, 360 degree indirect light, IP 65 protection all including fixing material on gate posts, connecting to the nearest light point complete all as specified and as directed by Engineer in Charge. Make:- Crompton, Cat No: LPTO-40-CDL or Equivalent in Bajaj/ Philips as approved by GE.
Supply & Fixing of LED bollard light fittings, 10 Watt, with IP65 protection, including installation and electric connection to light point complete all as specified and as directed by Engineer in Charge. Make: Crompton, Cat No: LBLA1-10-CDL or Equivalent in Bajaj/ Philips as approved by GE.
Material & Labour for PCC surface preparation by cleaning the surface from any moisture,dirt,wax, grease, flux residues and all other contaminants and applying two coats of AS 2045 Epoxy primer on PCC surface and applying two coats of Dielectric coating on the prepared surface having minimum electric strength of 32.2 KV/mm, minimum dielectric dissipation of 0.074, minimum dilectric constant of 10.93K, flash point above 25 Degree Celsius, minimum thickness of film shall be 3 mm complete all as specified and as directed by Engineer in Charge.
Note for Item No 62:- (i) The contractor shall submit a certificate from Govt Approved Lab certifying all the characteristics and properties of Dielectric coating to the Engineer in Charge. (ii) The contractor shall submit test report of the coating to Engineer in Charge. (iii) The rate quoted by the contractor is deemed to be inclusive of materials, T&P and Labour required for surface preparation.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire, one twin core cable flat or circular of size 6 Sqmm complete all as specified and as directed by Engineer in Charge.
Material & Labour for Cross arms, bracings, supports,clamps, MS Pipe, MS Plates fabricated from structural steel sections including nuts,bolts,washers, welding , bending cold or hot, drilling holes for bolts,in any shape or sizes as indicated at any loaction or as directed by Engr-in-Charge at site and inclusive of one primer coat and two coats of syntetic paint complete all as specified and directed. Note: Contractor should visit site before quoting the rate. Rates quoted by the contrcator is deemed to be inclusive of all safety equipments and T&P required for execution of work.
venkateshwara infra
M/S kirpan Enterprises
M/S. Niksun Electro-Infra Private Limited
ONKAR ELECTRIC AND GENERAL STORE
M/S. OM ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .