Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 CrAccepted-AOC | ₹37.8 Cr Quoted ₹38.0 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹44.7 CrRejected-Finance 421 4TH FLOOR TOWER A 2 SPAZE ITECH PARK SECTOR 49 SOHNA ROAD GURGAON | GURUGRAM | HARYANA | 122001 | ₹44.7 Cr | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹46.7 CrRejected-Finance | ₹46.7 Cr | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹46.9 CrRejected-Finance A 2 45 JANAKPURI NEW DELHI 110058 | NEW DELHI | NEW DELHI | DELHI | 110058 | ₹46.9 Cr | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹48.1 CrRejected-Finance | ₹48.1 Cr | L5 | Rejected-Finance Other than lowest |
Tender Value
₹47 Cr
EMD Value
₹15 L
Closing Date
25 Oct 2024, 6:00 pmClosed
CE Delhi Zone
HQ CE Delhi Zone Delhi Cantt-10
PROVN OF 126 DUS AND ALLIED WORKS AT DELHI CANTT (40 DUS FOR SENIOR OFFICERS)
2024_MES_671995_2
CEDZ/TOKEN-16 OF 2024
Open Tender
Civil Works
548 days
Delhi Cantt
As per tender documents
10 documents required · 10 mandatory
₹3,000
GE (P) East
₹15 L
Yes
19 Dec 2024
11 Oct 2024
28 Oct 2024
11 Oct 2024
25 Oct 2024
18 Oct 2024
Amount
Lump sum price worked out by the contractor for Schedule 'A' Section-II (Site Clearance) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-III (Exacavation and Earth Work) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-IV (Internal Electric supply) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-V (Internal Water Supply) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-VI (Demolition and Dismantling) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-VII (Road, Path and Culvert) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-VIII (External Water Supply) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-IX (External Electric Supply) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-X (Sewage Disposal) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-XI (Area Drainage) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-XII (Compound, Boundary Wall and Gate) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-XIII (Rain Water Harvesting) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-XIV (Hot Water Supply) (Ref pre priced Schedule attached seperately)
Description of Work / Item(s)
Amount
BUILDING WORKS
Lump sump price worked out by the contractor for Construction of Md accn for Senior Officers including Servant Quarter and Garrage with permanent specification in single storey independent bldg complete all as specified and shown on drawings.
Lump sump price worked out by the contractor for Construction of Pump House Bldg with permanent specification in single storey bldg complete all as specified and shown on drawings.
Lump sump price worked out by the contractor for Construction of Guard House with Rest room with permanent specification in single storey bldg complete all as specified and shown on drawings.
Lump sump price worked out by the contractor for Construction of Sentry Post with permanent specification in single storey bldg complete all as specified and shown on drawings.
Lump sump price worked out by the contractor for Construction of UG SUMP 320000 ltr For water supply with permanent specification complete all as specified and shown on drawings.
INTERNAL ELECTRIC SUPPLY
S&F Modular AC Box , power socket top 240 Volts AC Complete with one SP MCB 20 Amp all as specified and directed at site.
s &F wall monted fan of 300 mm sweep, 03 blades aerodynamically balanced with 60 degree oscillation, air delivery not less than 55 M3/Min, 1350 RPM, 230 V, 50Hz and Noise level not more than 64 dB with 2 years warranty complete all as specified and directed.
S & F LED bracket light fitting 1x 12 W, 220V,AC LED Lamp decorative wall mounting fixture made up of Aluminum body including LED 12 watt with System level efficacy of the Luminary is > 90 lm/W , Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5 Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix Sheet metal enclosure distribution board Loadline Vertical TPN, 415 volts, 4 way Horizontal/vertical type as per site requirement, double door type, metal door, not less than 1.2mm thickness, 120 Amps rated neutral copper bus bar for housing MCBs, blank plates and including provision for fixing MCCB 63 Amps,415 V, 16kA, TP/FP, as incommer and MCBs as outgoing connecting complete all as directed at site.
S & F of Fresh air ventilation fans of 250 mm sweep, speed 1280 RPM, Air delivery not less than 780 m^3 / Min, rated voltage 220-230, 50 Hz, Min two years warranty complete all as specified and directed.
S&F Building security light fittings, with pressure die cast aluminium housing, suitable for 30 Watt LED, complete pre-wired, including fixing bracket made using 0.6 mtr long 32mm dia light grade GI pipe bend to shape for fixing light on wall or any indicated locaction. The system wattage of fitting should not be more than 10 watt ± 10%, surge protection of minimum 2 kV, power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed. all as specified and as directed.
S & F Transparent Acrylic cover for fixing smart prepaid meter of suitable size including hinges and arrangement for sealing the box complete all as directed.
S&F USB charging port suitable for all type of Mobiles as directed by Engineer-in-charge.
SEWAGE DISPOSAL
S & F Steel Fibre Reinforced Concrete (SFRC) manhole solid cover of size 1.00 m x 0.5 m x 0.075 m thick complete all as specified.
M&L for DWCPE (SN8) 180 (Outer Dia), 163 (Internal Dia) mm dia pipe laid in trenches and jointed as specified
M&L for DWCPE (SN8) 200 (Outer Dia) 175 (Internal Dia) mm dia pipe laid in trenches and jointed as specified
RAIN WATER HARVESTING
M&L for drilling 300 mm dia bore hole by DTH cum Rotary at any depth below the ground level in any kind of rock/soil up to 100 m depth including disposal of surplus soil to a distance not exc. 50 mtr away all as specified and directed.
S&F self perforated UPVC pipe 160mm dia for pressure rating 10 Kg/Sqcm fixed complete to floors lowering and jointing self perforated in bore hole all as specified.
S&F PVC web cap 160mm dia all as specified and diredted.
ARBORICULTURE
Supply only fine sand at site including royalty and carriage for preparing compost at site (sand shall be brought at site and stacked for measurement before incorporating in the work) complete all as specified.
Supply only sweet / good earth at site including royalty and carriage for preparing compost for pits/required for planting trees and shrubs etc (sweet/good earth free from objectionable extraneous matter, toxic material and termites shall be brought at site and stacked for measurement before incorporating in the work. 20% of computed volume shall be reduced for loose stacking, complete all as specified.
Supply only manure at site including royality and carriage for preparing compost at site. Manure shall be brought at site and stacked for measurement before incorporating in the work. 8% computed volume shall be reduced for loose stacking completely all as specified.
Preparing compost pits of size 0.60x0.60x0.60 by excavation in ordinary soil carrying out antitermite treatment, planting trees & refilling of the pit with compost (manure, sand & sweet earth mixed in ratio (1:1:4) breaking moulds, ramming and flooding with water filling with more compost if necessary and fine dressing including removal of rubbish unserviceable materials & surplus soil to a distance n.exc 100 m. ATT shall be in form of 200 gms neem cake mixed with every cum of compost followed by Dursban or equivalent applied at 2 ml per litre in the first watering of 20 litres per pit, complete all as specified. Note :- (i) The rate for excavation and getting out of soil shall be deemed to be included in the unit rate of this item. (ii) The rate for mixing only earth, manure and sand is deemed to be included in the unit rate of this item supply of sweet earth, manure and sand shall be paid under respective item of this schedule.
Preparing compost pits of size 0.90x0.90x0.90 by excavation in ordinary soil, applying antermite treatment, planting the tree & refilling of pit with compoost (manure, sand & sweet earth mixed in ratio 1:1:4) breaking mould, ramming and flooding with water with more compost if necessary and fine dressing including removal of rubbish unserviceable materials and surplus soil to a distance n.exc 100m. ATT shall be in form of 200 gms neem cake mixed with every cum of compost followed by Dursban or equivalent applied at 2 ml Per litre in the first watering of 20 litrs per pit. Note:- 1. The rate for excavation and getting out of soil shall be deemed to be included in the unit rate of this item. 2. The rate for mixing only earth, manure and sand, deemed to be included in the unit rate of this item supply of sweet earth, manure and sand shall paid under respective item of this schedule.
Supply and planting following trees in location where shown on drawing and described in schedule 'A' and specifications/directed by Engr-in-Charge, girth 80mm to 100mm minimum (measured at 150mm top of roots) and complete provided necessary pots whereas required as per plants and height as shown under.
(a) Bottle palm `4' height
(b) Cycus palm 4' height
(c) Kochnar 4' height
(d) Champa 4' height
(e) Jacarnda mimo safelia 4' height
(f) Deloniox Regia (Gulmohar) 4' height
(g) Cassia fistala (Amaltas) 4' height
(h) Chinese Palm 4' height
(j) Bougenvillia varigelta 4' height
Supply and planting shrubs i.e. Aclypha 2', Calliandraz', Crotons 3', Hamcha, Jasminum capensis `Hibisew, Ticoma, Golden Dorangta, Red Hedge and complete provided necessary pots whereas required as per plants as directed by Engr-in-Charge.
INTERNAL WATER SUPPLY
M & L for CP Brass Wall Mixer 15mm bore for mixing hot & cold water screwed down for pipe and fixed complete
M & L for CP Brass Wash Hand Basin Mixer 15mm bore for mixing hot & cold water screwed down for pipe and fixed complete
S & F CP Brass Sink Mixer 15mm bore for mixing hot & cold water screwed down for pipe and fixed complete
S & F Bib Tap CP Brass Short body 15mm bore screwed down for pipe and fixed complete
S & F Stainless Steel Kitchen Plate Rack 900x1219x250mm with hanging to wall complete
S & F Soap dish CP brass complete
S & F Stainless steel Towel Ring round shape complete
S & F Liquid saop dispensor complete
S & F Bathroom Mirror Cabinet Fancy type complete
S & F Stainless steel anticocroch grating with frame complete
S & F chromium plated Tumbler Holder for WHB complete
S & F CP Brass Toilet paper holder with flap complete
S & F Stainless steel Towel Rack premium quality 24"complete
EXTERNAL WATER SUPPLY
Supplying, laying, jointing, testing and commmisioning of DI Pipe size 150 mm bore as per IS 8329-2000, class K-7 with inside cement mortar lining with spigot and socket ends laid in trenches all complete with tyton joint (with SBR gasket , IS-5332 marked ) suitable for the DI pipe complete all specified and directed by Engineer-in-charge.
Provn of valve pit chamber of size 900 X 900 X 900 mm internal dimension , 6mm thick MS steel cover with 2 Nos MS hinger suitable size welded with angle iron frame of 40x40x6mm thick with lifting hooks and locking arrangement complete with necessary earth work, brick work in cm (1:6), 230 mm thick PCC bed (1:4:8) type D-2, 150mm thick, 15mm thick cement plaster in cm 1:4 internal surface complete and external surface of wall up to 300 mm front top and applying a coat of black bituminous paint to the steel surface complete all as specified and directed.
Provn of valve pit chamber of size 300 X 300 X 300 mm internal dimension , 6mm thick MS steel cover with 2 Nos MS hinger suitable size welded with angle iron frame of 40x40x6mm thick with lifting hooks and locking arrangement complete with necessary earth work, brick work in cm (1:6), 230 mm thick PCC bed (1:4:8) type D-2, 150mm thick, 15mm thick cement plaster in cm 1:4 internal surface complete and external surface of wall up to 300 mm front top and applying a coat of black bituminous paint to the steel surface complete all as specified and directed.
Supply & installed complete foot valve conforming to IS 4038 of size 100mm dia
M&L for fabrication , installation testing MS pipe distribution header of under mentioned size including branches complete with welding work with two coat of anti corrosive spray paint over a coat of red oxide primer complete with end plates PCC work and FI clamps with suitable nut,bolt for securing of header pipe in PCC blocks as per following:- (a) Main Header- Main header of size 200 mm bore 4.0 mtr long made of MS pipe complete with end plates 10 mm thick welded at both ends. (b) Incoming- Incoming branch of size 50 mm bore GI pipe from borewell to headerwith one sluice valve 50 mm bore PN 1.6 & one NRV 50 mm bore PN 1.6 complete - 05 Nos. (c) Out going-Branch connection of size 100 mm bore MS pipe with one sluice valve 100 mm bore PN 1.6 each complete -01 Sets
M&L for fabrication , installation testing MS pipe distribution header of under mentioned size including branches complete with welding work with two coat of anti corrosive spray paint over a coat of red oxide primer complete with end plates PCC work and FI clamps with suitable nut,bolt for securing of header pipe in PCC blocks as per following :- (a) Main Header- Main header of size 200 mm bore 4.0 mtr long made of MS pipe complete with end plates 10 mm thick welded at both ends. (b) Incoming- Incoming branch of size 100 mm bore GI pipe from sump to headerwith one sluice valve 100 mm bore PN 1.6 & one NRV 100 mm bore PN 1.6 complete - 01 Nos. (c) Out going-Branch connection of size 100 mm bore GI pipe with one sluice valve 100 mm bore PN 1.6 each complete -02 Sets
M&L for fabrication, installation testing MS pipe distribution header of under mentioned size including branches complete with welding work with two coat of anti corrosive spray paint over a coat of red oxide primer complete with end plates PCC work and FI clamps with suitable nut,bolt for securing of header pipe in PCC blocks as per following :- (a) Main Header- Main header of size 200 mm bore 4.0 mtr long made of MS pipe complete with end plates 10 mm thick welded at both ends. (b) Incoming- Incoming branch of size 80 mm bore GI pipe heavy duty from each motor to headerwith one sluice valve 80 mm bore PN 1.6 & one NRV 80 mm bore PN 1.6 complete - 02 Nos. (c) Out going-Branch connection of size 150 mm bore MS pipe heavy with 0.5 mtr extended MS pipe with welded flanged of PN 1.6 each complete -01 Sets
Cast iron air valves singal air out lets conforming to IS 14845 of size 150mm dia bore and fixing up in cast iron water supply mains of size 150mm.
Supplying, installation, testing and commissioning of FP Box 2.0mm mm thick cubical indoor type weather proof, totally enclosed with IP 65 protection made out of CRCA sheet angle iron of size 50 mm x 50 mm x 6 mm suitable for 3 phase, 440 volts, 50 Hz including cable glands, phase indicators, internal wiring, voltmeter, ammeter, air passing holes with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc and locking arrangement with two locks godown type welded inside of the shutter with duplicate keys, spray painting with two coats of light gray paint over a coat of red oxide primer including writing and marking for all incoming and outgoing feeder with synthetic white coloured super enameled paint in one inch letter/number and mounted on two No bricks pillars including excavation and earth work complete PCC (1:2:4) brick work (1:4) and plastering complete:- INCOMING (a) MCCB 4 Pole 250 Amp 415 volts 25 KA rup cap=01No (b) Aluminium bus bar not less than 375 Amps with insulator-04 Nos (c) Multifunction energy meter three phase to Measure V, I, Hz, Kw, KVAr, KVA, PF, PA, I/E, KWH &KVArh, KVAh, Demand & Max Demand - A, Kw & KVA, etc. with necessary CTs acc class 0.5 , 10 VA Aux Supply: 230 V :- 01 Sets (d) Indicator lamp – one set (RYB)
OUTGOING (a) Providing single phase preventer- 03 Nos (for starter) (b) MCCB 4 Pole 63 Amp 415 volts 25 KA rup cap=06No (05Nos for submersible +01 Spare) (c) Dry Type Star Delta Starter for Motor with Pump, 415 V, 3 phase for 30 HP Motor - 03 Nos (d) MCB TPN 20 Amp-01 (e) MCB TPN 30 Amp- 01 (f) Phase sequence corrector – 01 No
Supplying, installation, testing and commissioning Centrifugal Pump set horizontal type split casing complete with electric motor of 30 HP, 415 Volts 3 phase, 50 Hz, AC supply, 1450 RPM capacity not less than 22 LPS at 60 mtr head inclusive of coupling and coupling guard and base frame complete with PCC foundation as per manufacturer specificaiton.
Supplying, installation, testing and commissioning Direct cylinder mounted type vacuum chlorinator for pressure feed including all gauges pump ,motor conforming to IS 10553 part -2 having capacity 1 to 1000gm/hr.
BOREWELL
M&L for MS reducer, bail plug, well cap, MS etc strip for centring, MS iron clamps, electric logging and sample strata box (40cm x 30cm x 20cm).
Material and Labour for drilling the pilot (Trial) bore of 200 mm by DTH/ Rotary rig drilling method below ground level upto 100 mtr for each bore in any type of soil, hard rock/ soft rock complete all as specified and directed by Engr-in-Charge.
Development of trial bore holes into tube wells by reaming upto 525 mm for 60 RM from ground level including casing pipe of 200 mm dia and thickness 8 mm and pea gravel complete all as specified and directed by Engr-in-Charge.
Development of trial bore holes into tube wells by reaming upto 525 mm from depth exceeding 60 meter to 100 meter including MS mediam grade casing pipe of 200 mm dia confirming to IS: 4270:2000 and thickness 8 mm and pea gravel complete all as specified and directed by Engr-in-Charge.
Development of trial bore holes into tube wells by reaming upto 525 mm from depth exceeding 60 meter to 100 meter including slotted pipe of 200 mm dia confirming to IS: 4270:2000 and thickness 8 mm and pea gravel complete all as specified and directed by Engr-in-Charge.
M&L for development of borewell by means of compressor and after pumping by pump with 25% extra capacity . Complete all as specified and directed by Engr-in-Charge.
M&L for yield test of the bore well by contineously pumping for 16 hrs to determine safe pumping yield.
M&l for water potable chemical analysis test from a govt approved lab inculding collecting the water from the given point into a glass/plastic jar, taking sample to the lab for testing and submiting the report as per the direction of Engineer -in - charge.
Material and labour for Supply, installation, lowering, testing and commissioning of submersible pumping set with outlet dia of pump not exceeding 32 mm having capacity 10 HP at 100 mtr head complete with submersible motor of suitable capacity, complete all as specified and directed.
Supply, lowering and fixing MS column pipe, ISI marked both end flanged 50 mm dia bore in 3 mtr length having wall thickness 4.8 mm as per IS-1239 complete including rubber gasket, slot cutting in flanges for passing of submersible cable and nut bolts etc all as specified and directed by Engr-in-charge.
Supply fabricate, installation and testing of LT Feeder Pillar Box outdoor type 45cm height from ground to bottom of pillar box, front openable door with locking arrangement with duplicate keys fixed with hinges throughout the wall of panel mounted on and incl PCC foundation and connecting LT panel cubical flush pattern made out of MS sheet 3.15mm thick with angle iron base frame of size 45x45x6mm for mounting of panel , dust proof, welded steel structure with locking arrangement having TPN Bus Bar 100 Amps rating capacity aluminium strip fixed with insulators 4 wire system painting of steel work with 2 coats of synthetic enamel paint over a coat of primer comprising of the following :- INCOMING (a) MCCB TP 415 Volts 40 Amps 10 KA – 01 No OUTGOING (a) MCB TP 415 Volts 32 Amps – 02 No (b) Multifunction energy meter three phase to Measure V, I, Hz, Kw, KVAr, KVA, PF, PA, I/E, KWH &KVArh, KVAh, Demand & Max Demand - A, Kw & KVA, etc. with inbuilt RS 485/MODBUS Card along with necessary CTs acc class 0.5 ,10 VA Aux Supply: 230 V :- 01 Sets (c) Dry type star delta starter suitable for 10 HP pump complete with over voltage and under voltage protection with over current and under current protection system -01 Nos (d) Phase indicating lamp (RYB) – 01 Set. (e) Phase sequence corrector with single phase preventor – 01 No
S&F submersible cable flat copper conductor PVC insulated and PVC sheathed 6.0 sqmm 3-core 415 V, 1100 V grade fixed to column pipe with suitable clamps jointing material complete.
EXTERNAL ELECTRIC SUPPLY
Supplying, installing, testing and commissioning of Indoor(IP4X) arc flash protected Draw-Out with roll on floor type Vacuum Circuit Breaker Panel, rated for 11kV, 630 Amp, 26.3kA/3-sec, comprising of 01 Nos outgoings, confirming to IEC 62271-200, Internal Arc Classified IAC AFLR – 26.3kA for 1sec, Accessibility Class LSC2B-PM Class, comprising of 800 Amp, continuous rated Insulated Copper busbars and droppers in all bus / breaker/ adaptor and cable chambers , 01no. Rack-In-Rack-Out Handles, structure made from AluZinc/GI/ Powder Coated CRCA sheets to prevent corrosion and rusting. The complete panel incl. HT and LT chamber with FRLS wiring and accessories shall be manufactured by approved OEM at its own manufacturing in house facility, and same will be verified via stage/final inspection. The Make of the VCB, Panel And Relay Shall be of the Same Make.The panel shall consist of following OEM / Makes: ABB/ Siemens/ Schneider Notes: (i) These HT panels shall be installed in with the existing / fixed with the existing VCB and Rate Quoted Shall be inclusive of the Adapter Panels/ connecting Copper Bus Links. (ii) Necessary Cat 6 and Modbus cabling from panels to existing RTU panel shall be provided by the contractor within this scope only. (A) 01 X Outgoing Panel each comprising of:- (i) 11 KV, 630 Amp, 26.3 kA/3- second, Draw out Vaccum Circuit Breaker as per IEC 62271-100 woth roll on floor type Vaccum Circuit Breaker having 03 Nos. Vaccum bottles of same make as of circuit breaker and panel, motorized spring charging mechanism (230VAC) with integral spring charging handle for manual charging, associated push-buttons, anti-pumping feature, and associated shunt Trip/close Coil (24 volts DC) (ii) Current transformer 11Kv, 200-100/1A, Core1 : Class5P10,. 5VA, Core2: Class0.5, 5VA- Set of 03 Nos per breaker
(V) Metering Equipment including :- (a) Digitel Ammeter (Acc.cl.0.05) (b) 01 No. Multi-Function-Meter (acc.Cl.0.5) shall be provided with LCD display for measuring current, voltage, power, power-factor and energy-parameters, Total Harmonic Distortion and Max. Demand indication, same shall be communicable on ModBus via RS485 port. (vi) LED Indications :- (a) Breaker ON/OFF/TRIP/Spring-Charged, (b) DC Available LED with push-button (c) AC Supply Fail (e) Trip Circuit Health (vii) 08-Windo Annunciator with Hooter to indicate following alarms :- (a) OC Trip, (b) EF Trip (b) Trip Circuit Failure (c) Inter-Tripping Fault, The Annunciator will be complete with required Acknowledge/Test Buttons as required (viii) Control Equipment incl :- (a) 01 x TNC Switch (b) 01 x Local/Remote Switch (c) 01 x Emergency Trip Push Button, (d) MCBs for AC (e) 3-Pin Socket with ON/OFF Switch - 01 No (f) LED Lamp with ON/OFF Switch-01 No (g) Power PAck (230V) AC to 24DC. (ix) Flush mounted Auxillary Protection Relays incl :- (a) Trip Circuit Supervision Relay, (b) Master Trip Relay, (c) DC Supervision Scheme
Supply, installation, testing & commissioning of 11kV 630Amps 21KA/3 sec. One-Extensible Outdoor (IP54) Ring Main Unit Compact switchgear consisting of 6 nos.( 02 Nos LBS and 04 Nos VCB) fixed motorized operated Vacuum Circuit Breaker Module in SF6 insulated inside 2.5mm thick SS304 grade stainless steel enclosure and Internal arc type tested for 21KA for 1 sec with AFLR classification for gas chamber & Cable compartment. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. The substation should be enclosed in chain link fencing with standard fittings comprise with spreading of pabbles all around minimum .30 mtr. The RMU shall be consisting for followings: (a) Microprocessor based IDMT Relay for aech Circuit Breakers - Self Powered along with series trip coil. (b) Capacitive voltage indication fixed type system with LED for each feeder (c) SF6 Gas pressure indicator and Battary 2X12V & Charger (d) VCB operating sequence must be O-0.3sec-CO-3MIN-CO (e) Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 nos. for each feeder (f) Metering CT shall be minimum 40/1A ,2.5VA ,0.5 class. - 3 nos. for each feeder (g) Single phase or 3 phase Air Insulated Voltage transformer 11KV/110V , 20 VA, accuracy: 0.5 (h) Auxiliary PT single phase 11KV/230V , 500VA for 230V AC supply to Battery charger (j) Multifunction meter with RS 485 port over Modbus for each VCB module for reading A, V, PF, KVA, KW, KWH, KVAR, KVARH etc (k) Right Angle Cable boot for each Module. (l) Civil Foundation for RMU as per OEM's recomandation and upto the satisfaction of site In-charge
Package Sub Station Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station ,315kVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation. Vacuum Interrupter,RMU,LT panel, MFM and CSS shall be of same make to ensure life cycle optimization. The substation should be enclosed in chain link fencing with standard fittings comprise with spreading of pabbles all around minimum .30 mtr. Note : CSS shall be from OEMs only . Licensed System Integrators are not allowed to supply. Package substation will have the following equipment :- HT SWITCHGEAR (a) 11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of 1 nos. fixed motorized operated Vacuum Circuit Breaker Module along with aditional cable module in SF6 insulated stainless steel enclosure (2.5mm thick SS304 grade stainless steel) enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No. (b) Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil. (c) Capacitive voltage indication fixed type system with LED. (d) SF6 Gas pressure indicator and Battary 2X12V & Charger.
(e) VCB operating sequence must be O-0.3sec-CO-3MIN-CO (f) Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 nos. (g) All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set TRANSFORMER (a)315 KVA 11KV/433V DYN-11 Copper Wounded Cast Resin Dry Type Transformer with Off load tap links of -5% to +5% @ 2.5% with WTI scanner,Class of Insulation: F, Temperature rise limits 90 deg.C over an ambient of 40 degrees. Losses shall be as per latest ECBC-2021 code with WTI scanner. - 1 No. (b) Winding Temperature Indicator with 1 alarm and trip contact. - 1 No. (c) Surge arrestor in the HV side. - 1 Set LT PANEL (a) LVS PANEL 700 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.6/2 mm thick CRCA sheet INCOMER FROM TRANSFORMER (a) 01 Nos.500 Amps 415V 4P 50Hz 50KA microprocessor releaseType Moulded Case Circuit Breaker (MCCB) (b) Multifunction meter of class 0.5 accuracy. - 1 No. along with suitable CT
OUTGOING (a) 03 Nos. 250 Amps 415V 4P 50Hz 25KA microprocessor releaseType Moulded Case Circuit Breaker (MCCB) (b) Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control) to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (c) All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturer's recomandation are included in scope of work. OUTDOOR ENCLOSURE (a) Outdoor type encloser of 1.6 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT panel, MFM and CSS shall be of same make to ensure life cycle optimization.
Supply & installing, testing and commissioning factory made and tested (incl proto type being CPRI test certified) LT main panel, outdoor type, IP-65, floor mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system having bus bar chamber duly insulated copper bus bars four strip of rating 400 Amps for phase & neutral, installed on epoxy/SMC type insulator. The panel shall be dust and vermin proof IP-54 class protection and made of 3.15 mm CRCA sheet and powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer inside, internal wiring with PVC insulated, copper conductor, FRLS cables IS-694 marked of adequate size but not less than 1.5 Sqmm etc. complete all as specified and directed. PCC foundation as per OEM, MS frame made out of 50 x50 x6 mm agnle iron having four legs 750mm long each 300mm embedded in ground , lugs of suitable size cost of cable gland for incoing and outgoing are included. The scope of work includes the following :-(Security Light and Pump House) (a) Incoming :- (i) ON LOAD change over switch 415V,4 pole of capacity 250 Amps -01 Nos (ii) MCCB FP 415V with adjustable microprocessure release, breaking capacity 50KA, Capacity 250 Amp - 01 Nos (iii) Multifunction energy meter three phase to Measure V, I, Hz, Kw, KVAr, KVA, PF, PA, I/E, KWH &KVArh, KVAh, Demand & Max Demand - A, Kw & KVA, etc. with inbuilt RS 485/MODBUS Card along with necessary CTs acc class 0.5 ,10 VA Aux Supply: 230 V :- 01 Sets (iv) Indicating Lamps : 01 set (R Y B) (b) Outgoing :- (i) MCCB FP 415V with adjustable microprocessure release, breaking capacity 50KA, Capacity 160Amp- 01 Nos (For Supply Water Pump Panel)
(ii) MCCB FP 415V with adjustable microprocessure release, breaking capacity 50KA, Capacity 100 Amp- 01 Nos (For Submerisble Pump) (iii) MCB 4 Pole 32 Amp 25KA, 415V (for Building light and security light -01 No (iv) All incoming & outgoing feeders shall be connected by cable through suitable size gland plate/glands. (v) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
Supply & installing, testing and commissioning factory made and tested (incl proto type being CPRI test certified) LT main panel, outdoor type,IP-65, floor mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system having bus bar chamber duly insulated copper bus bars four strip of rating 2000 Amps for phase & neutral, installed on epoxy/SMC type insulator. The panel shall be dust and vermin proof IP-54 class protection and made of 3.15 mm CRCA sheet and powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer inside, internal wiring with PVC insulated, copper conductor, FRLS cables IS-694 marked of adequate size but not less than 1.5 Sqmm etc. complete all as specified and directed. The LT Panel should be enclosed in chain link fencing with standard fittings comprise with spreading of pabbles all around minimum .30 mtr .PCC foundation as per OEM, MS frame made out of 50 x50 x6 mm agnle iron having four legs 750mm long each 300mm embedded in ground , lugs of suitable size cost of cable gland for incoing and outgoing are included.. The scope of work includes the following :- (a) Incoming :- (i) ACB 4 pole 415 V with microprocessor release IPR E based, breaking cap 50 KA , current rating 1250 Amps, drawout type. - 01 No (incoming from T/F 630 KVA to Main LT Panel) (ii) Multifunction energy meter three phase to Measure V, I, Hz, Kw, KVAr, KVA, PF, PA, I/E, KWH &KVArh, KVAh, Demand & Max Demand - A, Kw & KVA, etc. with inbuilt RS 485/MODBUS Card along with necessary CTs acc class 0.5 ,10 VA Aux Supply: 230 V :- 01 Sets (iii) Indicating Lamps : 01 set (b) Outgoing :- (i) MCCB FP 415V with adjustable microprocessure release, breaking capacity 25KA, Capacity 250 Amp- 04 Nos(36 Maj Gen qtr) (ii) MCCB FP 415V with adjustable microprocessure release, breaking capacity 25KA, Capacity 315 Amp- 01 Nos(Servent Qtr Panel No-1) (iii) MCCB FP 415V with adjustable microprocessure release, breaking capacity 25KA, Capacity 315 Amp- 01 Nos(Servent Qtr Panel No-2)
(iv) ACB 4 pole 415 V with microprocessor release IPR E based, breaking cap25 KA , current rating 630 Amps, drawout type. - 01 No APFC Panel) (v) MCCB FP 415V with adjustable microprocessure release, breaking capacity 25KA, Capacity 200 Amp- 01 Nos(Lift) (vi) MCCB FP 415V with adjustable microprocessure release, breaking capacity 25KA, Capacity 100 Amp- 01 Nos(Pump) (vii) MCCB FP 415V with adjustable microprocessure release, breaking capacity 25KA, Capacity 160 Amp- 01 Nos(Fire Fighting) (viii) MCCB FP 415V with adjustable microprocessure release, breaking capacity 25KA, Capacity 125 Amp- 01 Nos(STP ) (ix) MCB 4 Pole 25 Amp 25KA, 415V (Street Light)-01 (x) Space for MCCB 4P 100 A.-01 No (xi) All incoming & outgoing feeders shall be connected by cable through suitable size gland plate/glands. (xii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
Supply & installing, testing and commissioning factory made and tested (incl proto type being CPRI test certified) LT main panel, outdoor type, IP-65, floor mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system having bus bar chamber duly insulated aluminium bus bars four strip of rating 600 Amp for phase & neutral, installed on epoxy/SMC type insulator. The panel shall be dust and vermin proof IP-54 class protection and made of 3.15 mm CRCA sheet and powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer inside, internal wiring with PVC insulated, copper conductor, FRLS cables IS-694 marked of adequate size but not less than 1.5 Sqmm etc. complete all as specified and directed. The LT Panel should be enclosed in chain link fencing with standard fittings comprise with spreading of pabbles all around minimum .30 mtr .PCC foundation as per OEM, MS frame made out of 50 x50 x6 mm agnle iron having four legs 750mm long each 300mm embedded in ground , lugs of suitable size cost of cable gland for incoing and outgoing are included.. The scope of work includes the following :- (Bldg Panel to House for Lt Gen Qtr) (a) Incoming :- (i) MCCB FP 415V with adjustable microprocessure release, breaking capacity 25KA, Capacity 250 Amp (ii) Multifunction energy meter three phase to Measure V, I, Hz, Kw, KVAr, KVA, PF, PA, I/E, KWH &KVArh, KVAh, Demand & Max Demand - A, Kw & KVA, etc. with inbuilt RS 485/MODBUS Card along with necessary CTs acc class 0.5 ,10 VA Aux Supply: 230 V :- 01 Sets (iii) Indicating Lamps : 01 set (b) Outgoing :- (i) MCCB, 4P, 415V with thermal magnetic, breaking capacity 16KA, Capacity 40 Amp- 11 Nos (ii) Street light timer switch with analoge type timer with TPN contractor of switchable rating toggle switch for auto/ manual mode complete in all respect - 01 Set (iii) All incoming & outgoing feeders shall be connected by cable through suitable size gland plate/glands. (iv) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
Supply, installing, testing and commissioning of Lt Automatic power factor panel 125 KVAR, outdoor type, 13 Setps of (5x3 + 10 x 6 + 12.5x4 KVAR) Shall be dust and vermin proof, protection class (IP-65) and made of 3.15 mm thick CRCA Sheet & suitable frame work/ support made out of 50 x 50 x 6 mm, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade.The LT Panel should be enclosed in chain link fencing with standard fittings comprise with spreading of pabbles all around minimum .30 mtr. PCC foundation as per OEM, MS frame made out of 50 x50 x6 mm agnle iron having four legs 750mm long each 300mm embedded in ground , lugs of suitable size cost of cable gland for incoing and outgoing are included. The scope of work also comprising of the following:- ( for 315 KVA Transformer) (a) Microprocessor based MCCB, 3 Phase of required ratng, MD-XL capacity capacitor 440V rating, heavy duty capacitor switching contactor, Mircroprocessor based intelligent power factor corrector relays. The APFC panel shall have following safety features over voltage/ under voltage protection, short circuit protection, No volt release feature to immediately disconnect all capacitors in the event of power failure & automatic resetting after restoration of electric supply Note : The equipment offered shall be complete in all respects. Any material and components not specifically stated in this specification but which is necessary for trouble free operation of the equipment and accessories specified in this specification, shall be deemed to be included unless specifically excluded. The equipment shall conform in all respects to high standards of engineering design and workmanship and shall be capable of performing in continuous operation.
Supply, installing, testing and commissioning of Lt Automatic power factor panel 300 KVAR, outdoor type, 15 Setps of (5x4 +10 x 8+2x25 + 50 x3) KVAR each, Shall be dust and vermin proof, protection class (IP-65) and made of 3.0 mm thick CRCA Sheet & suitable frame work/ support made out of 50 x 50 x 6 mm, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade. The LT Panel should be enclosed in chain link fencing with standard fittings comprise with spreading of pabbles all around minimum .30 mtr. PCC foundation as per OEM, MS frame made out of 50 x50 x6 mm agnle iron having four legs 750mm long each 300mm embedded in ground , lugs of suitable size cost of cable gland for incoing and outgoing are included. The scope of work also comprising of the following:- ( for 630 KVA Transformer) (a) Microprocessor based MCCB, 3 Phase of required ratng, MD-XL capacity capacitor 440V rating, heavy duty capacitor switching contactor, Mircroprocessor based intelligent power factor corrector relays. The APFC panel shall have following safety features over voltage/ under voltage protection, short circuit protection, No volt release feature to immediately disconnect all capacitors in the event of power failure & automatic resetting after restoration of electric supply. Note : The equipment offered shall be complete in all respects. Any material and components not specifically stated in this specification but which is necessary for trouble free operation of the equipment and accessories specified in this specification, shall be deemed to be included unless specifically excluded. The equipment shall conform in all respects to high standards of engineering design and workmanship and shall be capable of performing in continuous operation.
Supplying, transporting to site, erection and fixing in position, Hot dipped GI octagonal pole 8 mtr height having top dia 70mm, botton dia 130mm, sheet thickness 3.0 mm, base plate of size 220mm x 200mm x 12mm foundation bolt 4 x M20x 750mm (No x dia x lenght) with OCD 225mm complete with in build juction box with cable termination arrangement for 3.5 x 35 sqmm cable, 1 mtr long single arm bracket of hot dipped GI top mounted type complete, with 01x 06 A MCB SP, 10K with foundation RCC as per manufacturere specifications complete all as specefied and directed.
S&Fixing only LED 36 W street light fitting with pressure die cast Al housing with heat resistant toughened glasss and IP-65 protection complete with suitable fixing arrangement on steel tubular pole using suitable pipe, clamps etc and connection with 3 core 1.5 sqmm PVC copper cable up to junction box complete all as specified and directed.
S& Fixing only LED 120 W flood light with pressure die cast Al housing with heat resistant toughened glasss and IP-65 protection complete with suitable fixing arrangement on steel tubular pole using suitable pipe, clamps etc and connection with 3 core 1.5 sqmm PVC copper cable up to junction box complete all as specified and directed.
S&F route indicator for HT cable embeded in PCC
S&F route indicator for LT cable embeded in PCC
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure
Supplying, fixing 3 core 1.5 Sqmm PVC cable complete all as specified and directed.
DG SET
Supply , installation, commissioning and testing silent diesel engine driven Gen Set 100 KVA (80 KW at 0.8 PF) capacity 415 Volts, 3 phase, 4 wire acoustic weather proof enclosure as per CPCB -IV norms and noise level shall not exceeding 75 db at a distance of 1 metre, Engine as per IS-10001/1002 an d Alternator as per IS-13364 installed on PCC platform as per manufacture recommendation complete comprising the following components:- (a) Diesel Engine :- Diesel Engine developing suitable BHP, 1500 water cooled engine inclusive of the following standard accessories (i) spider coupling guard (ii) Fly wheel (iii) Fly wheel housing complete with starter gear ring and coupling (iv) Fuel pipe (v) Air cleaner (vii) Fuel & Lub oil filter (vii) By pass filter (ix) Fuel pump (x) Lub oil pump (xi) Electric Starter 12 Volts DC (xii) Battery charging generator (DC alternator) (xiii) Industrial silencer (xiv) Lub oil cooler (xv) flexible pipe for sinencer (xvi) DC voltmeter (xvii) lub oil pressure gauge, lub oil/water temperature gauge. (xviii) Speedo meter and engine running hours meter (xix) Display for fault (xx) Governor (xxi) Battery as per manufacturer recommendation-01 No.
(b) ALTERNATOR: Alternator suitable for continuous operation generation 100 KVA at 1500 RPM 415 V at NTP, 0.8 power factor 3 phase, 50Hz, self excited and regulated with ball/roller bearing confirming to IS-4722 (c) AMF PANEL(Inbuild) : AMF Panel, factor made, outdoor double door, cubical type, front open able fabricated out of CRCA sheet 3.15 mm thick of suitable size complete as per manufacturer's specification, suitable for DG set of Cap 100 KVA and consisting of the following:- (i) Contactor of suitable capacity (ii) Aluminium Bus bar (iii) Sensitivity relay set unit with auxiliary CT's (iv) Electronic Circuit with tripping indication. (v) RE-set facilities for complete protection of AMF Panel (vi) Instantaneous tripping device suitable for complete panel over current 0.5 Amps. (vii) 3 Phase AVR relay unit complete. (viii) Self sequential starting relay unit 12 V DC complete with alarm & power contractor (ix) Electronic timer 240V, 50Hz, (180 seconds0 for main contractor with 1 NO/NC auxiliary contracts. (x) --do- As per Srl No (ix) here-in-before but for fuel cut-off-operation. (xi) Battery charging unit complete with digital volt meter & Amp meter. (xii) Digital voltmeter, 0-500 volts, panel mounting of size 96 mm square (xiii) Digital Amp meter, 0-100 Amps with 3 No CT's 100/5 .
HOT WATER SUPPLY
S&F Instant Seyser Useful for Kitchen, quick water heating 5 L Greater the Capacity, more the users can be served for bath/wash 8 Bar : Pressure rating > 8 bar is suitable for High Rise buildings Vertical : Suitable for large wall spaces
COMPOUND/BOUNDARY WALL AND GATE
M&L for 250mm wide, 2.5 mm thick aluminium expansion joint plate with all necessary connections and fittings as directed by Engr-in-Charge.
AMIT ASSOCIATES (BID ID -3149020)
MAHINDER PAL CONSTRUCTIONS PVT LTD (BID ID -3149416)
Satish Chand Rajesh Kumar Pvt. Ltd. (BID ID -3145484)
Global Enterprises (BID ID -3150017)
PRAGMATIC INFRASTRUCTURE LIMITED (BID ID -3149870)
Aalaya Engineering Project Private Limited (BID ID -3145953)
Ktech Engineer Builders Co. Pvt. Ltd (BID ID -3149672)
B D Raizada Projects Pvt Ltd (BID ID -3148919)
TALWADEKARS INDIA BUILDCON (BID ID -3150052)
MUKUL BUILDERS LLP (BID ID -3149764)
SOOD ASSOCIATES PVT LTD (BID ID -3149878)
City Promoter and Buildwell Pvt. Ltd. (BID ID -3149869)
MC Gandhi and Sons (BID ID -3149725)
Som Projects Pvt. Ltd. (BID ID -3149689)
Varindera Constructions Limited (BID ID -3148712)
Aalaya Engineering Project Private Limited (BID ID -3145953)
Global Enterprises (BID ID -3150017)
MAHINDER PAL CONSTRUCTIONS PVT LTD (BID ID -3149416)
Satish Chand Rajesh Kumar Pvt. Ltd. (BID ID -3145484)
AMIT ASSOCIATES (BID ID -3149020)
PRAGMATIC INFRASTRUCTURE LIMITED (BID ID -3149870)
Ktech Engineer Builders Co. Pvt. Ltd (BID ID -3149672)
TALWADEKARS INDIA BUILDCON (BID ID -3150052)
SOOD ASSOCIATES PVT LTD (BID ID -3149878)
B D Raizada Projects Pvt Ltd (BID ID -3148919)
MUKUL BUILDERS LLP (BID ID -3149764)
City Promoter and Buildwell Pvt. Ltd. (BID ID -3149869)
Varindera Constructions Limited (BID ID -3148712)
Som Projects Pvt. Ltd. (BID ID -3149689)
MC Gandhi and Sons (BID ID -3149725)
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid