| 1 | L1₹33.3 LAccepted-AOC ALPHA HOUSE PLOT NO 29 AGP P10 ASHWIN SECTOR NEW CIDCO NASIK 422 009 | NASHIK | MAHARASHTRA | 422009 | L1 | Accepted-AOC SINCE L1 | |
| 2 | L2₹35.7 L+₹68,522.13 (1.96%)Rejected-Finance | L2 | Rejected-Finance SINCE NOT L1 | |
| 3 | L3₹36.4 L+₹1.4 L (3.98%)Rejected-Finance | L3 | Rejected-Finance SINCE NOT L1 | |
| 4 | L4₹36.6 L+₹1.6 L (4.65%)Rejected-Finance | L4 | Rejected-Finance SINCE NOT L1 | |
| 5 | L5₹37.8 L+₹2.9 L (8.17%)Rejected-Finance | L5 | Rejected-Finance SINCE NOT L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
29 Aug 2022, 6:00 pmClosed
GE DEOLALI
GE DEOLALI, 422401
SPL REPAIRS TO JCOS MESS KITCHEN AND DINING HALL WHICH INCLS REPLACEMENT OF COMPLETE ROOF WITH CORRUGATED SHEETS, REPLASTERING AND PAINTING IN BLDG NO. MLS 8/9A OF 201 ARMY AVN SQN UH, SPLREPAIRS TO BLDG NO. MLS 04 SIGNAL, TECH / BQJ, GUN AND MT STOR
2022_MES_542641_1
8130/E8
Open Tender
Civil Works
Item Rate
180 days
GE DEOLALI
CLASS D cat a i
8 documents required · 8 mandatory
₹500
Yes
GE DEOLALI
₹90,000
Yes
15 Nov 2022
2 Aug 2022
31 Aug 2022
2 Aug 2022
29 Aug 2022
16 Aug 2022
Amount
Dismantling of single layer mangalore pattern or similar tiles in roofing complete all as specified and directed.
Dismantling of battens for tiles, shingles etc, of any size including titing fillets spaced exc 15cm complete all as specified and directed.
Dismantling timber scantling 40 Sq cm and over in section in any position as in unframed work complete all as specified and directed.
M & L for Clean sawn 2nd class hard wood in scantling as a post and rafter complete all as specified.
S&F steel work (tubular/hollow) in trusses, rafters, beams, purlins etc, including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and as as directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering including ridges /cladding to wall, fixed with self tapping screws as specified and directed.
S&F for 0.50mm thick pre-painted galvalume aluminium zinc coating GI based plain steel sheet any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specified and directed.
M&L for preparation of New or old previously untreated steel or iron surfaces of any description over 10cm in girth or width and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Demolition of brickwork of stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stone work and precast concrete articles complete all as specified and as directed.
M&L for Brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and as directed.
M&L for Brickwork with fly ash old size bricks, straight or curved on plan built in CM (1:6) in half brick thick walls etc., complete all as specified and as directed.
M&L for rendering 15mm thick plaster in CM (1:6) on faces of brick work or concrete surfaces, finished with 1.5mm thick wall care putty finish complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth (without using extra cement ) complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards / slabs / blankets, any thickness, including cover fillets complete all as specified and directed.
S&F for powder coated aluminum alloy interlocking snap grid 600mm x 600mm consists of Main Tee runners of size 38mm x 25mm x 1.5mm and cross Tee of size 25mm x 25mm x 1.5mm, spaced between the main Tee at 600mm centre to centre to form a grid of 600mm x 600mm and wall angle 25mm x 25mm x 2mm fixed to wall perimetrs at 450mm centres and shall conform to IS 733, IS 1285 with and including hangers of 3mm dia. G.I. (upto 1200mm length and 1200mm centres) adjusting level fixed to roof steel members by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long etc complete all as specified and directed .
M&L for 4mm thick non asbestos fibre cement building boards of make 'E Board classic designer board (Cascade or Occenic) of M/S Everest industries Ltd or equivalent as approved, fixed or laid/ inserted to timber/GI/Aluminium framework complete all as specified and directed .
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified.
Demolition of cement concrete in ground floors & paving not exc 15cm thickness (below or above ground level) complete all as specified.
M&L for 50mm thick cement concrete type D-2, 1:4:8 (40 mm graded stone aggregate) as a sub base complete all as specified.
M&L for screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 etc., complete all as specified.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for Non-skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry with and pointed in coloured cement match the colour of tiles etc.,complete all as specified.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10mm thick backing coat in CM (1:4) complete all as specified and as directed.
M&L for Glazed ceramic coloured tiles of size 350 x 250 x 7mm/450 x 350 x 7mm thick on vertical surfaces of walls such as skirting dado etc., over 10mm thick screed bed/backing coat in CM 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match etc., complete all as specified.
M&L for Granite 20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including griding and polishing etc., complete all as specified.
M&L for Machine cut cudappa stone slab 25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc., complete all as specified.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations all as specified.
M&L for Complete removal of existing treatment, washing, scrubbing down, preparing surfaces and over 1.5mm thick putty and providing one priming coat and two coats of oil bound distemper on walls all as specified.
M&L for preparing new plastered or unplastered surfaces of walls, and applying two coats of oil emulsion distempering over a coat of interior wall primer etc., complete all as specified and directed.
Taking down Chowkats or frames exc.1.5 sq.m but not exc. 4 sq.m each but with shutters (without taking off shutters from the frame) and removing to or from store etc., complete all as specified.
Taking down chowkat or frame with shutters (with out taking off shutter from the frame) not exceeding 1.5 Sqm each and removing to or from store etc., complete all as specified.
S&F 18 mm thick Plywood BWR type BB, fixed with screws to timber frame work complete all as specified and directed.
S&F flush shutter, solid core construction ,with block board core and plywood face panels ,commercial type on both faces including teak wood beading 6mm thick all around, 30 mm thick etc., complete all as specified.
M&L for 0.9mm thick decorative laminate type 1, of surface finish, colour and pattern as approved fixed with approved adhesive as per manufacturer instructions etc., complete all as specified.
S&F powder coated aluminium sliding window, three/two track shutters, side hung type with sash bars, locking rails, locking arrangements including necessay joinery cleats, glazing clips, rubber packing, Chowkats aluminium snap beading, screws, suitable handle etc with and including sheet glass or ordinary glazing quality of 5mm thick and incl GI wire mesh 0.56 mm nominal dia of wire and average width of aperture 1.18 mm , size of side rails , top rails , bottom rail 85x44.5mm and size of chowkat frame 101.6x44.45mm and thickness of aluminium member shall be 1.40mm thick complete all as specified in MES SSR, Part-I clause 10.37 all as specified and as directed.
S&F in repairs extruded Brass handles, fabricated type polished 150 mm complete all as specified.
S&F in repairs brass, barrel tower bolts, with cast or sheet barrel and rolled or cast bolts 200 mm complete all as specified.
S&F in repairs brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts 300mm complete all as specified.
S&F in repairs floor door stopper of brass, body and tongue with hard drawn steel spring 140mm overall length of cover plate complete all as specified.
S&F in repairs Butt hinges, medium weight, Brass, type B-11 and fixed 125 mm length complete all as specified.
S&F framed work such as grills, gratings, etc with ends of bars, shouldered and /or riveted, or forged into spikes, framed guard bars, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 410-0 all as specified.
S&F in repairs 25mm dia fancy stainless steel curtain rod with fancy fixing brackets, fancy stops/supports, rollers etc. complete all as specified.
Dismantling of boarding any description fixed in any position with nails complete all as specified and as directed
M&L for Prelaminated particle board of 18/19mm thick, interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination with teak wood leaping fixed with screws as in cupboard shutters of bed room, kitchen and internal shelves complete all as specified.
S&F in repairs Butt hinges, medium weight, Brass type B-12, and fixed 75 mm length complete all as specified.
S&F in repairs for hasp and staple aluminium anodished safety type with mild steel hinges pin incl bolt to hinge plate and fixed with screw 125mm size.
S&F in repairs for 75mm long Aluminium anodizes barrel tower bolts of extruded section complete all as specified and as directed.
S&F in repairs 100 mm size aluminium anodized handle complete all as specified and as directed.
S&F in repairs for magnet catches with striking plate for closing of cupboard shutters complete all as specified.
S&F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and as directed.
Taking up or down 20mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and as directed.
S&F 15mm boreTubes, `medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S&F 20mm boreTubes, `medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Dismantling of PVC Pipes with fittings upto 75mm to 110mm dia complete all as specified and as directed.
S&F for 110mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed.
S&F for 75mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed.
S&F PVC (SWR) bend with access door any radius 110mm complete all as specified and directed.
S&F PVC (SWR) bend with access door any radius 75mm complete all as specified and directed.
S&F for 110mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and directed.
S&F PVC (SWR) bend any radius 75mm complete all as specified and directed.
S&F PVC (SWR) bend any radius 110mm complete all as specified and directed.
S&F in repairs 75mm bore PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F in repairs 15mm bore Bib taps CP fancy type, cast copper, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S&F in repairs 15mm bore, 450mm long, PVC connections with brass unions internally threaded both ends complete fixed to iron pipe at both ends as fixed in repairs complete all as specified and as directed.
S&F in repairs CP fancy type stop/angle valves, cast copper alloy, screwed both ends for iron pipe or for union of 15mm bore complete all as specified and as directed.
Taking down cement plaster any description on brick or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed.
S&F for 20mm thick boarding second class with nails/screws in any situation (except flooring and skirting) clean sawn with butt joints.
M&L for preparation of New or old previously untreated wood or wood based surfaces of any description over 10cm in girth or width and painting with two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
M&L for Complete removal of existing treatment and applying three coats of white wash complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core
Supply & fix Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole 20 A MCB
M & L for sub main wiring with 4 single core, 4 Sq. mm, PVC insulated unsheathed,multi stranded copper conductor FRLS cable 1100 Volts grade incl 4.0 Sqmm PVC insulated unsheathed multi stranded copper conductor FRLS as continuous earth wire and connecting to common earth terminals complete all as specified and directed in capping- casing. Note :-(i) four run of copper cable and one run of earth wire and casing capping shall be measured as one length.
Ditto all as per item No - 74 above but with 2 runs of 6 Sqmm cable with one run of 4 Sqmm cable for earthing.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) TPN and 63 Amps current carrying capacity in the DB complete with connection testing and commissioning.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) TP and 32 Amps current carrying capacity in the DB complete with connection testing and commissioning.
Supply and fix sheet metal enclosure with 200 Amps rated bus-bar DB TPN 4Way 415 V, double door type
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
M&L for sand cushioning to under ground cable providing with a layer of and 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge (Note : punning thickness of 18 cm will be measured for payment)
Supply only of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground all as specified and directed ( earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to GI strip 25mm x 4mm by means of bolts, nuts, check nuts & washers of galvanized iron all as shown in electrical plate No 5 connected to earth test point all as specified or indicated and testing on completion including necessary excavation and earth work in any type of strata, PCC pit and RCC cover GI protection pipe 15 mm bore light grade upto 7.5 m length earth lead upto meter board, watering pipe, wire mesh etc, all as specified and directed by Engineer-in-Charge.
Taking down unserviceable carefully copper/aluminium point wiring (light, fan, socket or power) complete with teak wood battens including fittings such as switches, socket outlets, ceiling roses, pendent brackets, holders etc. but excluding fan regulators, tube light fittings and sketch fittings and making good disturbed surfaces of walls, floor etc.complete all as directed.
Material and labour for point wiring with stranded copper conductor PVC insulated unsheathed 1.5 Sqmm FRLS cable in and including PVC casing caping of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow,Tee,collers bend, PVC conduit for crossing etc. complete with PVC terminals box for mounting switches, sockets, fan regulators etc with one single core continuous 1.5 Sqmm,FRLS copper cable for earth wire complete all as specified and as directed for the following :-
One Light point controlled by one switch
One fan point controlled by one switch
One 5 pin socket outlet. 5 Amps on the same board.
One 5 pin socket outlet. 5 Amps on the independent. board
All as item No- 86 above but One 15 A socket outlet independent with 2.5 sq mm PVC cable and 1.5 sqmm cable as earth continuity wire.
Supply and fix switch piano flush type single pole one way 5 Amps complete all as specied .
Supply and fix switch socket combination 3 pin 5 Amps flush type (multi purpose ) complete all as specified and as directed.
Supply and fix switch socket combination 2 in 1, 3 pin, 5 and 15 amp flush type universal complete all as specified and as directed.
Supply and fix ceiling rose of size 65mm X 25 mm surface Bakelite three terminals complete all as specified and as directed.
S & F lamp angle/batten holder Bakelite complete all as specified and as directed.
S&F in replacement LED tube light 20 Watt fitting white powder coated slim box type batten made of formed CRCA sheet with snap on installer sutable for double side connection LED tube in and including batten and tube etc complete in all respect.
Supply and fix in replacement fan regulator 100 watts electronic type for ceiling fan of size 900 mm to 1400 mm sweep working on 230 Volts AC supply with all necessary connections etc complete all as specified and as directed.
Supply and fix in repairs sheet metal enclosure DBs SPN, 240V with 200 Amps rated bus bars double door complete all as specified and as directed of following sizes:-
Supply and fix in replacement MCB SP 6 to 32 Amps, 240 volts complete all as specified and as directed.
Supply and fix in replacement MCB SPN 32 Amps, 240 volts complete all as specified and as directed.
M & L in replacement of sub main wiring with 2 single core, 6 Sq. mm, PVC insulated unsheathed,multi stranded copper conductor FRLS cable 1100 Volts grade incl 4.0 Sqmm PVC insulated unsheathed multi stranded copper conductor FRLS as continuous earth wire and connecting to common earth terminals complete all as specified and directed in Existing conduits/ PVC capping- casing. Note :-(i) Two run of copper cable and one run of earth wire shall be measured as one length. (ii) If Casing- capping required at site, they will be measured and paid under respective items
Ditto all as per item No - 97 above but with 2 runs of 4 Sqmm cable with one run of 2.5 Sqmm cable for earthing.
S & F in repairs Plug & socket enclosure in sheet metal enclosure with 20A SP MCB complete all as specified and as directed.
Taking down old u/s post top lantern fittings and S&F New generation, post-top energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light sourceof 25 watt.
S&F LED Bldg Security light Endura Pearl having long life versalite pressure die-cast aluminium housing with high power LED as Lighting source and lens embedded PC Cover having top opening seperate driver compartment with IP66 and impact resisitance of IK 07 roadway luminaries with high power 25 W LED as light source with acrylic cover
M & L for bracket made out of GI tubing 40 mm dia,light grade 1.0 mtr long including fixing with MS clamps -2 Nos made out of 50 mm wide 5mm thick flat iron with M.S. nuts, bolts 75 mm long 12 mm dia -4 Nos & flat washer (3mm thick) 01 No. for each including preparation of steel surfaces and painting with two coats of aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete all as specified and as directed.
S & F of Recess mounting 34W LED 6000K luminaire fixture diffused suitable for ceiling size 2'X2'(Feet) (580X580 mm), fixture size (595X595 MM) armstrong / grid/ POP Ceiling with separate eletronic driver & High brightness LEDs including required accessories and eletric connections complete all as specified and as directed.
S&F in replacement decorative wall light, stainless steel, rust free fixture with white glass diffuser suitable for & including 7.5 W LED filament lamp, E27 base.
M&L for renewal of earthing of poles,system with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick buride vertically in ground not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground leveland conected to GI wire 4 mm by means of nuts,bolts and washers and encased in and including 40mm dia GI light grade pipe upto 2.4 mtr height from ground level fixed by MS flat iron clamp 40mm x 5mm with nut,bolt and washers ,GI wire fixed to base along pole and connected to existing system with alternate layer of charcoal dust ,salt packed around plate 150mm thick including watering GI pipe ,light grade 20 mm dia 1.5 mtr long fixed to funnel with wire mesh complete with PCC chamber and RCC chamber cover all as per electrical plate NO3 of SSR Part-1 -2009 including excavation and earth work in any type of starta and testing on completion.(Note:-GI wire and GI pipe beyond 7.5mtr long shall be measured and paid separately.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circula 10 sqmm
Note: Amount of sch of credit of Rs.90897/-will be deducted from total amount of BOQ.
M/s Nilesh Enterprises
Vinod Enterprises
Vishal Constructions
J Sams Contructions
JEET CONSTRUCTIONS CO.
M/S R.K.S. CONSTRUCTION
UNITED ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .