Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹30.6 L+₹1.7 L (5.76%)Admitted-Finance RADHA NIKUNJ L 2 SOUTH CIVIL LINES ROORKEE HARIDWAR UTTARAKHAND 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | L2 | Admitted-Finance | |
| 3 | L3₹31.7 L+₹2.9 L (9.89%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹32.0 L+₹3.1 L (10.7%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹35.7 L+₹6.8 L (23.5%)Admitted-Finance KORAMANGALATH HOUSE TOMY LANE SOUTH PANAMBILLY NAGAR KADAVANTHRA P O KOCHI 682 020 | KOCHI | ERNAKULAM | KERALA | 682020 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | R.K. Builders L1 | STANDARD ENGINEERING L3 | K.V.GEORGE AND COMPANY L5 | K R A ENGINEERING & CONSTRUCTION L4 | EX SOLDIERS MECHANICAL WORKS L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down split /window AC, Refrigerator and water cooler of any capacity from existing place in any position and deposited to MES store yard complete all as specified and as directed . | 43 | Each | 501 ₹21,543 Lowest | 1,100 ₹47,300 | 5,900 ₹2,53,700 | 1,800 ₹77,400 | 1,200 ₹51,600 |
| 2.00 | Disconnecting the cables and dismantling the PCC and taking down pumps of any capacity from existing place and deposited to MES store yard complete all as specified and as directed . | 2 | Each | 560 ₹1,120 Lowest | 1,000 ₹2,000 | 2,990 ₹5,980 | 1,000 ₹2,000 | 5,000 ₹10,000 |
| 3.00 | Supply, installation, testing and commissioning of split air conditioning unit 1.5 TR capacity with inbuilt air filter complete with cordless remote control, BEE 5 star rated, latest enegry efficient model eco friendly refrigerant gas, 50 Hz, 240 volts, air cooled condensor with all accessories varied speed including fixing the outdoor unit with suitable site requirement and fixing of indoor unit on high wall with necessary wall cutting/ making holes to pass the refrigerant pipes, drain pipes, cables etc and making good to match with existing finishing complete, providing and making interconnection including refrigerant piping with nitrile rubber insulation from indoor to outdoor as provided by OEM and control cable from indoor to outdoor & power cabling from isolator/enclosure to indoor unit as per site requirement, first charging of refrigerant gas including cordless remote, drain piping of suitable size including connection drain lines from unit to nearest drain points complete all as specified and as directed. | 25 | Each | 68,300 ₹17,07,500 | 68,000 ₹17,00,000 | 72,500 ₹18,12,500 | 74,000 ₹18,50,000 | 63,000 ₹15,75,000 Lowest |
| 4.00 | S & F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and a capacity of 5 KVA complete all as specified and directed. | 25 | Each | 3,900 ₹97,500 Lowest | 9,900 ₹2,47,500 | 4,550 ₹1,13,750 | 6,200 ₹1,55,000 | 5,800 ₹1,45,000 |
| 5.00 | S & F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 240 V 20 Amps complete all as specified and as directed . | 25 | Each | 1,400 ₹35,000 Lowest | 2,200 ₹55,000 | 1,650 ₹41,250 | 2,100 ₹52,500 | 1,800 ₹45,000 |
| 6.00 | M&L Submain wiring with two runs of 4.0 sqmm size multi stranded copper conductor PVC insulated unsheathed cable (FRLS) in and including PVC casing & caping and one run of 4.0 sqmm size multi stranded copper conductor PVC insulated unsheathed cable (FRLS) for continous earth wire complete all as specified and as directed
Note : Three Runs of 4.0 sqmm cable and one run of PVC casing & caping and shall be measured as one unit. | 400 | Rm | 320 ₹1,28,000 Lowest | 380 ₹1,52,000 | 475 ₹1,90,000 | 480 ₹1,92,000 | 450 ₹1,80,000 |
| 7.00 | S & F MCB SP 5 to 32 A 240V, 10 KA 'B' curve complete all as specified and as directed. | 25 | Each | 265 ₹6,625 | 300 ₹7,500 | 350 ₹8,750 | 320 ₹8,000 | 230 ₹5,750 Lowest |
| 8.00 | Supply, installation, commissioning of Water cooler partialy stainless steel body electric driven,single phase having storage capacity 80 Ltrs and nominal cooling capacity of 40 Ltrs per hour complete all as specified and as directed . | 6 | Each | 57,000 ₹3,42,000 | 51,000 ₹3,06,000 | 69,200 ₹4,15,200 | 46,200 ₹2,77,200 Lowest | 54,000 ₹3,24,000 |
| 9.00 | Supply, installation, commissioning of Water cooler partialy stainless steel body electric driven,single phase having storage capacity 40 Ltrs and nominal cooling capacity of 40 Ltrs per hour complete all as specified and as directed . | 3 | Each | 45,000 ₹1,35,000 Lowest | 50,000 ₹1,50,000 | 66,900 ₹2,00,700 | 61,200 ₹1,83,600 | 53,000 ₹1,59,000 |
| 10.00 | Supply, installation, commissioning of refrigerator of capacity 190 litres electric driven,single phase complete all as specified and directed . | 6 | Each | 27,500 ₹1,65,000 | 27,400 ₹1,64,400 | 37,200 ₹2,23,200 | 22,000 ₹1,32,000 Lowest | 38,000 ₹2,28,000 |
Tender Value
₹36.7 L
EMD Value
₹73,440
Closing Date
23 Aug 2025, 6:00 pmClosed
GE NAVY LAKSHADWEEP
GE (Navy) Lakshadweep Kavaratti
SPECIAL REPAIRS REPLACEMENT OF BER SPLIT ACS REFRIGERATOR WATER COOLER DEEP FREEZER AND PUMPSETS AT NAVY STATIONS UNDER GE NAVY LAKSHADWEEP
2025_MES_722587_1
8420
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
LAKSHADWEEP
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE NAVY LAKSHADWEEP
₹73,440
Yes
12 Sept 2025
25 Jul 2025
25 Aug 2025
25 Jul 2025
23 Aug 2025
8 Aug 2025
Amount
Taking down split /window AC, Refrigerator and water cooler of any capacity from existing place in any position and deposited to MES store yard complete all as specified and as directed .
Disconnecting the cables and dismantling the PCC and taking down pumps of any capacity from existing place and deposited to MES store yard complete all as specified and as directed .
Supply, installation, testing and commissioning of split air conditioning unit 1.5 TR capacity with inbuilt air filter complete with cordless remote control, BEE 5 star rated, latest enegry efficient model eco friendly refrigerant gas, 50 Hz, 240 volts, air cooled condensor with all accessories varied speed including fixing the outdoor unit with suitable site requirement and fixing of indoor unit on high wall with necessary wall cutting/ making holes to pass the refrigerant pipes, drain pipes, cables etc and making good to match with existing finishing complete, providing and making interconnection including refrigerant piping with nitrile rubber insulation from indoor to outdoor as provided by OEM and control cable from indoor to outdoor & power cabling from isolator/enclosure to indoor unit as per site requirement, first charging of refrigerant gas including cordless remote, drain piping of suitable size including connection drain lines from unit to nearest drain points complete all as specified and as directed.
S & F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and a capacity of 5 KVA complete all as specified and directed.
S & F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 240 V 20 Amps complete all as specified and as directed .
M&L Submain wiring with two runs of 4.0 sqmm size multi stranded copper conductor PVC insulated unsheathed cable (FRLS) in and including PVC casing & caping and one run of 4.0 sqmm size multi stranded copper conductor PVC insulated unsheathed cable (FRLS) for continous earth wire complete all as specified and as directed Note : Three Runs of 4.0 sqmm cable and one run of PVC casing & caping and shall be measured as one unit.
S & F MCB SP 5 to 32 A 240V, 10 KA 'B' curve complete all as specified and as directed.
Supply, installation, commissioning of Water cooler partialy stainless steel body electric driven,single phase having storage capacity 80 Ltrs and nominal cooling capacity of 40 Ltrs per hour complete all as specified and as directed .
Supply, installation, commissioning of Water cooler partialy stainless steel body electric driven,single phase having storage capacity 40 Ltrs and nominal cooling capacity of 40 Ltrs per hour complete all as specified and as directed .
Supply, installation, commissioning of refrigerator of capacity 190 litres electric driven,single phase complete all as specified and directed .
Supply, installation, commissioning of refrigerator of capacity 310 litres electric driven,single phase complete all as specified and directed .
Supply, installation, commissioning of glass top Deep Freezer of capacity 400 litres single phase 240 volt, 50 Hz complete all as specified and directed .
S & F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 270 V with output voltage stabilized at 200 - 240 V with accuracy of +/- 2.5% and a capacity of 2 KVA complete all as specified and directed.
Supply, fixing, testing and commisioing of centrifugal monoblock pump of capacity 1.5 HP, 12 Mtrs head, single phase, 220 V, 50 HZ including foundation complete all as specified and as directed.
Supply, fixing, testing and commisioing of centrifugal monoblock pump of capacity 1.0 HP, 11 Mtrs head, single phase, 220 V, 50 HZ including foundation complete all as specified and as directed.
S&F direct onload starter upto 2 HP single phase,230 volts, 50 HZ, complete all as specified and as directed .
EX SOLDIERS MECHANICAL WORKS (BID ID -3403454)
STANDARD ENGINEERING (BID ID -3403420)
K R A ENGINEERING & CONSTRUCTION (BID ID -3400458)
K.V.GEORGE AND COMPANY (BID ID -3403946)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .