Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.7 LAccepted-AOC 2 4 136 4TH BLOCK LINGA REDDY MANSION OPP TARBUND SECUNDERABD TARBUND SECUNDERABAD TELANGANA 500009 | HYDERABAD | TELANGANA | 500009 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹47.5 L+₹1.6 L (3.39%)Rejected-AOC | L2 | Rejected-AOC BEING NO L1 |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
4 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (UTILITY) SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
MISCELLANEOUS REPAIRS TO VARIOUS E/M INSTALLATIONS AND CLEANING OF WELLS AND ALLIED WORKS UNDER AGE E/M NO 1 OF GE (U) SECUNDERABAD
2023_MES_577125_1
GE (U)/SEC/TOKEN/70 OF 2022-2023
Open Tender
Civil Works - Water Works
Item Rate
180 days
SECUNDERABAD
AS PER NIT
7 documents required · 7 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹95,000
Yes
11 Aug 2023
25 Jan 2023
11 Mar 2023
25 Jan 2023
4 Mar 2023
8 Feb 2023
Amount
M&L for Cleaning, de-slugging open wells at various locations by Eight Stage Method : - (a) Removal of Complete Debris inside the well and surroundings. During cleaning safety measures like oxygen level inside to be checked. For every feet cleaning, Removing Debris addition of bioenzyme, Disinfection to be used. (b) De-slugging the decomposed waste in the well for every 3000 litter Vacuum suction using Jetting machine. (c) Sending the debris and waste water to Fecal Sludge Treatment Plant (FSTP) for further processing. Vendor should have authorised MOU with GOVT FSTP. (d) Complete disinfection of the well area using 200 ml/liters chlorine solution using mechanical spray/long handled broom. Then addition Bio-Enzyme for further BIO remediation of the organic material at each steps up to depth of 30 to 40ft. (e) Disinfect the water in the well with a 50/100 mg/liters chlorine dosage (depending contamination) and leave for a minimum of 30 min on and dewater the well and allow it to fully recharge. (f) After recharge check the chlorine residual in the water, where necessary, repeat the process of dewatering and recharging the well until, the chlorine level has reduced to 0.5 mg/liters or below. (g) Covering the wells proper Geo Text Tile membrane 0.03 mm Thickness. Authorised dealer certificate required for OEM. (h) Applying of Biological weedicide around the well for good esthetical appearance and no further Bushy Development all as specified and as directed by Engineer-in-Charge.
Note: - Quoted Rates includive of all procedures mentioned above and deemed to be inclusive of the following :- (a) Installation of display board MS 306 Acrylic coated water resistant paint mentioning the details of well, Name of the agency, date of cleaning, expiry date, depth and dia of the well. (b) Agency should produce the Test Certificate of all the chemicals used for cleaning from Govt Approved laboratory. (c) After complete REHABILITATING OF OPEN WELL, water portability to be checked from any govt approved lab. (d) The work shall also include all needed equipment like well dewatering pump for sludge, Air compressor, Crane/winch/manual chain pulley, hoist, tripod, electric generator... etc. and also required safety equipment like (Gumboot, helmets, Safety belts, Safety goggles, torch light etc). (e) Manpower involved in well repair, cleaning and disinfection should be fully trained on the risk and good health and strictly adhere to safety practice. Necessary insurance for safety of working staff to execute the work is responsibility of the contractor. (f) The working area should be fenced, a kerb constructed (of there is no head well) and at least 2 m around the well should be kept clear of objects which could fall in. Lighting arrangements if required to be provided by the contractor, temporarily at his own arrangements and the amount quoted is deemed to be inclusive in the unit rate. Electricity/diesel shall not be provided by the MES. (g) Open well to REHABILITE is not in use for long back. Contractor should visit the site to understand site condition as well as the condition of open well before coating the rates. No claim in this regard will be entertained during execution stage. (h) Vendor who execute the work should be authorised for any Govt department for this kind of work.
M&L for Cleaning, de-slugging open wells at various locations by Eight Stage Method : - (a) Removal of Complete Debris inside the well and surroundings. During cleaning safety measures like oxygen level inside to be checked. For every feet cleaning, Removing Debris addition of bioenzyme, Disinfection to be used. (b) De-slugging the decomposed waste in the well for every 3000 litter Vacuum suction using Jetting machine. (c) Sending the debris and waste water to Fecal Sludge Treatment Plant (FSTP) for further processing. Vendor should have authorised MOU with GOVT FSTP. (d) Complete disinfection of the well area using 200 ml/liters chlorine solution using mechanical spray/long handled broom. Then addition Bio-Enzyme for further BIO remediation of the organic material at each steps up to depth of 30 ft. (e) Disinfect the water in the well with a 50/100 mg/liters chlorine dosage (depending contamination) and leave for a minimum of 30 min on and dewater the well and allow it to fully recharge. (f) After recharge check the chlorine residual in the water, where necessary, repeat the process of dewatering and recharging the well until, the chlorine level has reduced to 0.5 mg/liters or below. (g) Covering the wells proper Geo Text Tile membrane 0.03 mm Thickness. Authorised dealer cert required for OEM. (h) Applying of Biological weedicide around the well for good esthetical appearance and no further Bushy Development all as specified and as directed by Engineer-in-Charge.
Note: - Note: - Quoted Rates includive of all procedures mentioned above and deemed to be inclusive of the following :- (a) Installation of display board MS 306 Acrylic coated water resistant paint mentioning the details of well, Name of the agency, date of cleaning , expiry date, depth and dia of the well. (b) Agency should produce the Test Certificate of all the chemicals used for cleaning from Govt Approved laboratory. (c) After complete REHABILITATING OF OPEN WELL, water portability to be checked from any govt approved lab. (d) The work shall also include all needed equipment like well dewatering pump for sludge, Air compressor, Crane/winch/manual chain pulley, hoist, tripod, electric generator... etc. and also required safety equipment like (Gumboot, helmets, Safety belts, Safety goggles, torch light etc). (e) Manpower involved in well repair, cleaning and disinfection should be fully trained on the risk and good health and strictly adhere to safety practice. Necessary insurance for safety of working staff to execute the work is responsibility of the contractor. (f) The working area should be fenced, a kerb constructed (of there is no head well) and at least 2 m around the well should be kept clear of objects which could fall in. Lighting arrangements if required to be provided by the contractor, temporarily at his own arrangements and the amount quoted that is deemed to be inclusive in the unit rate. Electricity/diesel shall not be provided by the MES. (g) Open well to REHABILITE is not in use for long back. Contractor should visit the site to understand site condition as well as the condition of open well before coating the rates. No claim in this regard will be entertained during execution stage. (h) Vendor who execute the work should be authorised for any Govt department for this kind of work.
Dismantling of existing pump unit, motor, pipes and any other parts of open well of AGE E/M No 1 Sub Station and servicing the pump and make it functional and reinstall after cleaning of wells complete all as specified and directed by Engineer-in-Charge . The work shall also include all needed equipment (hoist, tripod, crane, electric generator... etc.) to complete the work as required. The cleaning of wells shall be measured and paid separately under relevant item of the BOQ.
Taking down unserviceable water softner and Supply , installation, commissioning and testing of water Softner of capacity 3000 LPH. The equipment shall be suitable to operate on a single phase 220v/50Hz power supply including necessary foundation and UPVC water supply pipe line of suitable size for water connection with accessoris and control valve, electrical works all as recommended by manufacterer and any other items required at site for smooth functioning of plant complete all as specified and directed by Engr-in-Charge. Make:- Aqua Soft Softner/ Purit Softener/SVS. The feed shall be having following characters :- (i) Raw water pump - 1.5 HP.(ii) Sand Filter and carbon filter vessel (IS 1865)- 1 Each. (iii) Carbon- 900 iv,- 150 Each.(iv) Sand- 50 KG bag- 6 Nos. (v) Pebbles – 4 Each set. (vi) Multiprt Valve - 40nb-2 Nos. (vii) Distribution Strainer - 4 Nos. (viii) Dosing System- 0-61ph - 1Nos. (ix) 20" Jumbo housing and Jumb filter - 2 Nos. (x) High Pressure Pump - 4E-19- 1 No. (xi) Membrane 8" - 3 No.(xii) SS Skid - 40mm- 1 No. (xiii) Control Panel - 1*3 - 1 Set. (xiv) Flow meter - 4800LPH - 2Nos. (xv) Float - 2 Nos. (xvi) LPS - 1 No. (xvii) Pressure Gauge SS- 21/1”- 2 Nos. (xviii) Solenoid Valve 1”-1 Nos (xix) Dosing Chemical- 5 Lts (xx) Pipe and fittings – 1 Set.
Taking down unserviceable shed and M&L for water softner plant Room of size 3 mtr x 3 mtr x 2 mtr ht incl necessary excavation in hard/ dense soil and all as specified below:- (i) Wall with Precast panels of size 6ft x 1 ft x 40mm made out of M-30 concrete reiforced with 3 nos, 3mm bars and cured for 20 days, jointed neatly with 43 grade cement; fixed on Pre-cast poles of size 150mm x 150mm x 8 ft made out of M-30 concrete reiforced with 5 nos, 3mm bars and cured for 20 days, erected vertically and embedded in PCC 1:3:6 type C1 using 20 mm graded stone aggregate. (ii) Floor with 25mm thick PCC 1:2:4 type B0 using 12.5 mm graded stone aggregates over and above 100mm thick hardcore using 20 mm graded stone aggregates well watered and rammed, finished smooth. (iii) Roof with pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 12mm thick. (iv) Finishing coat:- 2 coats of Cement based paint over a coat of primer externally and 2 coats of Oil Based Distemper over a coat of primer internally. above GL including 150 mm Hard core, 100 mm PCC 1:3:6 type C2 40 mm graded aggregates, 20 mm screed bed complete all as specified and directed
Supply & lay heavy duty PVC insulated multi stranded Aluminum conductor twin core of size 6.0 Sqmm, 230 volts, 50 HZ complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar or cement lime mortar including all quoins, arches,pillars, ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with sub class B bricks, straight or curved on plan exc 6 m mean radius built in cement mortar (1:6) complete all as specified and directed.
M&L for Walling of squared rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar in 1:4 all as specified and directed.
Raking out joints/ pointing to squared rubble masonry, coursed or uncoursed in walls or stone on edge in floors, surface channels, roofs, etc built in cement or cement lime mortar including washing the joints and keeping the surface to be pointed wet for 2 days prior to re-pointing; including removal of vegetation if any all as specified and directed.
M&L for Hammer dressing to face stones and dressing of face beds and joints, as specified, of squared rubble masonry, regular coursed with maximum depression on face from straight edge held against the dressed surface n exc. 20mm for any type stone all as specified and directed.
M&L for Flush pointing to squared rubble masonry, coursed or uncoursed in cement mortar 1:4 all as specified and directed.
Rendering 15 mm thick in cement and sand mortar 1:6 on other than fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement complete all as specified and directed.
Demolishing lime concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
Dismantling asbestos cement (corrugated, semi corrugated) sheets including ridges as in roof covering complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed.
Excavation in post holes (or similar holes) each n.exc 0.50 cu.m getting out in hard/ dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm complete all as specified and directed.
M&L PCC 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) in foundations, filling and mass concrete
S&F steel work in tubular trusses / poles (unframed) including purlins, rafters and special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS-1161-1979 grade St-240 complete all as specified and directed.
M&L for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws including ridge complete all as specified and directed.
M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering etc.; to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe 410-W (Gde-E- 250) quality-A including dismantling of old fencing complete all as specified and directed.
M&L for framed works in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 including dismantling of old fencing complete all as specified and directed.
Supply and fixing in repair chain link MS galvanised fencing wire any size including line wires of weight not less than 3.08kg/sqm, to any type of standards rails, straining bolts etc., including provision of binding with mild steel wire annealed not less than 0.9mm dia etc. complete all as specified and directed.
M&L Two coats of synthetic enamel paint on steel surfaces of any description, over 10cm in width or girth, over a coat of primer incl preperation of new surfaces all as specified
M&L Two coats of synthetic enamel paint on steel surfaces of any description, n.exc 10cm in width or girth, over a coat of primer incl preperation of new surfaces all as specified
Surface excavation not exc 30 cm deep and ave 15 cm deep and getting out in hard/dense soil complete all as specified.
Removing surplus excavated soil to a distance not exc 50 Mt & depositing where directed at a level not exc 1.5 Mt above the starting point complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base or sub floors finishing the surfaces even and rough to receive the topping layer complete all as specified and directed.
M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for machine vibrated precast concrete interlocking paver blocks any shape, any size, confirming to IS 15658-2006 of 80 mm thick and M-40 grade laid over sand cushion with grey cement and pigment complete all as specified and directed. Note:- Sand cushning shall be measured and paid separately .
M&L Precast cement concrete 1:2:4 type B-1( using 20 mm graded stone aggregate) as in road kerbs incl one edge chamfared complete all as directed
M&L Hardcore of broken stone, gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface
M&L for 75 mm thick Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) finishing the surfaces even complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
Mfive waterand environmental solutions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .