Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.4 LAccepted-Finance | 1 | Accepted-Finance Accept | |
| 2 | 2₹23.3 L+₹7.8 L (50.6%)Accepted-Finance 2ND FLOOR SHOP NO 303 MARUTI PLAZA RONCHI BANGAR TOWNSHIP MATHURA | MATHURA | UTTAR PRADESH | 281001 | 2 | Accepted-Finance Accept | |
| 3 | 3₹23.6 L+₹8.1 L (52.5%)Accepted-Finance | 3 | Accepted-Finance Accept | |
| 4 | Not Admitted-Fee/PreQual/Technical 01 KATYANI CONSTRUCTION COMPANY H NO 1 SHOP NO 1 RATAN LAL NAGAR KANPUR NAGAR UTTAR PRADESH 208022 | KANPUR NAGAR | UTTAR PRADESH | 208022 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
5 Dec 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE ETD FATEHGARH
ETD FATEHGARH, 132 KV S/S BEWAR ROAD FATEHGARH, FARRUKHABAD-209602
WORK
2022_UPTCL_750620_1
T-26/ETD(F)/2022-23
Open Tender
Electrical Works
Fixed-rate
90 days
KANNAUJ
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,832
UPPTCL ETD FATEHGARH
₹48,000
3 Feb 2023
19 Nov 2022
5 Dec 2022
19 Nov 2022
5 Dec 2022
19 Nov 2022
Amount
ERECTION OF FOLLOWING AT 132 KV SUB-STATION KANNAUJ FOR CONSTRUCTION OF 132 KV AND 33 KV BAY.
Erection of Main & Auxiliary Sub-Station Structure for 40 MVA Transformer Bay
Proper stacking and shifting of Main & auxiliary structure in open switchyard at erecting place as per shop bill norms
Erection of Main & Auxiliary structure lattice type ATM,AXM,XPM,YMM,BBL,BCT,ALP,ABL etc. consisting of column, beam, peak, mast etc. and auxiliary structure for installation of isolator, CTs, PTs, LA etc. erection of structure as per drawing with the help of GI nuts & Bolts flat spring washer matching the hole, cutting and matching the member if required include cost of all men and T & P excluding GI structure nut and bolts to complete the work erection of main & auxiliary structure lattice type upon foundation and its proper tightening.
Making hole in part of GI Main/auxiliary structure / cutting of GI angle drilling of hole existing/ defective structure /plate/Angle and grinding machine with all cost of men, T & P etc.
Erection of following equipment as per instruction manual of various equipment’s and technical specification including shifting of material / equipment from store to erection site including all other associated works to complete the job satisfactorily.
Erection of 145 KV SF6 Circuit Breaker
Erection of 36 KV Vacuum Circuit Breaker
Erection of 145 KV Current Transformer
Erection of 36 KV Current Transformer
Erection and mounting of 145/36 KV CT/PT junction box.
Erection of 145 KV bus Isolator without earth switch
Erection of 36 KV Bus Isolator.
Erection of 120 KV Lighting Arrestors
Erection of 30 KV Lighting Arrestors
Erection of following control and relay Panels as per instruction manual and technical specification including shifting of panel from store to erection site including all other associated works to complete the job satisfactorily.
Erection of 132 KV control relay panel for 40 MVA Transformer.
Erection of LT out door cubical for LT supply
Erection of 40 MVA RTCC Panel.
Stringing of 132 KV jack bus of ACSR panther conductor of 36 mtr length span as mentioned below .the work includes cutting &bending of conductor fixing of single /double bolted type tension fitting /suspension hoisting of disc Insulator and shifting of material from store .site to erection site and all other associated work to complete work satisfactorily as per drawing and technical specification.
132 KV Jack Bus for 40 MVA Transformer
Bay wise interconnection of equipment with specified conductor of various 132 KV & 33 KV Equipment with Main /Transfer / jack Bus bar of ACSR Zebra /Panther conductor. The work Includes cutting of conductor. Bending in proper shape .clamping with the help of clamp and all other associated work to complete job.
40 MVA Transformer Bay 132 KV side Bus
33 KV side Transformer bay Twin Moose
Laying and Termination of following size control cable in trench/cable trays from different control room equipment to 132/33 KV Isolator, circuit breakers CT/PT & their junction boxes. Transformer marshaling box. Isolator box & other outdoor equipment’s installed in 132/33 KV switch yard as per cable schedule. Including carriage of cable drum from store and all other associated work.
Control cable of size 2 core x 2.5 mm2
Control cable of size 4 core x 2.5 mm2
Control cable of size 6 core x 2.5 mm2
Control cable of size 10 core x 2.5 mm2
Termination of control cable
Installation work of 40 MVA Transformer
Shifting of main tank of 40 MVA Transformer from unloading point to the plinth up to 30 Mtr. distance including turning of tank if required including all T & P and labour required to complete the job satisfactorily.
Complete erection of 40 MVA 132/33 KV Transformer by erection of radiator, conservator t and all bushing oil pipe lines, cooling fans etc. to complete the job satisfactorily.
Circulation of complete Transformer oil in Transformer tank through centrifuging machine, centrifuging machine shall be provided by the contractor, oil capacity (Approx. 20 KL)
Errection of 250 KVA, 33/0.4 KV station transformer on plinth after shifting it from stacking place to errection site. Work also including its neutral and main tank earthing. Jumpering its BSI form main 33 KV bus by single panther conductor. Errection of fuse set interconnection of its HV side terminal by BSI through fuse set using standard rating fuse set.
Laying & Termination of following size PVC power cable from ACDB /DCDB installed on control room to 33/.04 KV station Transformer marshaling box etc. in 132/33 KV switchyard in side 500mm below ground level including excavation of trench & laying on its edge along with cable of both side filling the same with Ganga sand and then putting the bricks on 115mm side cover the trench & then filling with earth. Proper termination at both side by providing crimping type aluminum lugs as per requirement including cost of bricks sand cable route marker as per cable schedule including carriage of cable drum from store and all other associated works.
Power cable 31/2 core x 300 mm2 /150 mm2
300 mm2 Power cable termination.
Fabrication of 3 meter long electrode with 40 mm dia. M S round bar having 150 mm long conical shape by digging cutting, straightening etc. and then placing it vertical. inside the ground with Top 700mm below the ground level including shifting of MS round bar from storage place at the Sub-Station to switchyard.
Delta earthing of 120KV ,33 KV LA's and132/33 KV 40 MVA Transformers neutral by consisting of 6/3 Nos. 3.0 Mtr long electrode of 40mm dia. having 150mm long conical shape, its placing inside the ground in rectangular/triangular shape and connection all 6/3 Nos. electrodes with 75x10/50x6mm MS flite laid on its edge and then this rectangle/triangle shape be connected to main earth mat at two place in opposite direction strictly as per drawing.
120 KV Lighting Arrestors (Rectangle shape 6 electrode )
30 KV Lighting Arrestors (Rectangle shape 6 electrode )
132/33 KV 40 MVA Transformer (Triangular shape 3 electrode)
Earthing of equipment’s by cutting straightening, bending, laying 700mm below ground and above ground of following size of MS flat for earthing of main and auxiliary structure, equipment’s structure. Transformer body and its neutral point including welding with main earthmat and with object to be earthed excavation of trenches its back filling. All other associated work as required to complete the work. MS Flat shall be provided by the contractor.
Laying of MS Flat of size 75x10 mm
Laying of MS Flat of size 50x6 mm
Laying of MS Flat of size 25x6 mm
Painting of MS flat of different size after cleaning of rusted surface 1st coat of Red Oxide and 2 coat of Bus Green Paint to complete the work.
MS Flat of size 75x10 mm
MS Flat of size 50x6 mm
MS Flat of size 25x6 mm
Periphery and switchyard lighting
Providing and fixing of half round bend GI pipe OD-50mm for mounting the 120 Watt LED light upon gantry mounting of 2 No GI bracket up on gantry and fixing GI pipe complete with nut bolt and washer as per technical specification.
Providing and fixing of junction box on gantry structure with 1 No MS flat 40x5 mm of size 200x200x150 mm made of MS sheet of 16 gauge dully powder coated inside mounting 1 No 6 Amp MCB 1 No TB of 4 terminal & 1 No Kit Kat 16 Amp fixed upon mica sheet and back side mounting a flat 40x5 mm with 1 No 16mm dia. hole and mounting PVC pipe from ground level to box as per technical specification.
Providing & fixing of new generation energy saving and environment friendly long life versatile pressure die cost aluminum out door high been flood light with high power 120 Watt LED as light source and exclusively designed polycarbonate cover along with electronic driver complete fitting suitable for 220 V input supply for ISI make CGL/Hevels/ Surya/ Philips/Bajaj of equivalent etc. including electrical connection also to be done by the contractor.
STRENTHENING OF 33 KV MAIN BUS FROM SINGLE TARANTULLA TO TWIN MOOSE SHALL BE CARRIED OUT AS DETAILED HERE UNDER.
Dismantling of 33 KV Old/ Damaged Main bus bar Sections (R, Y, & B) of Single Tarantulla conductor and lowering down of conductor from sub-station gantry to complete dismantling work including dismantling of all associated Tension clamps, fittings & Disc insulators etc.
Dismantling of Jumpering of 33 KV Equipment, jumper from main bus to 33 KV switchgear, Moose/Panther conductor.
Dismantling of Jumpering of 33 KV Equipment, jumper from Section Isolator 33 KV switchgear, Moose/Zebra conductor.
Stringing and proper sagging of new 33 KV Main bus bar Sections (R, Y & B) by Twin Moose conductor the work includes fitting of tension clamps, Hoisting of 70 KN Disc, tension fittings, Spacers PG Clamps etc. and cutting of conductor as required.
Jumpering of 33 KV Equipment, jumper from main bus/Line Isolator to 33 KV switchgear, Twin Panther conductor.
Jumpering of 33 KV Equipment, jumper from Section Isolator for Twin Moose Conductor.
SUPPLY
Supply of following material required for construction of 132/33 KV bays for 40 MVA T/F 3rd and strengthening of existing 33 KV main bus
PG Clamp Moose to Moose
PG Clamp Moose to Panther
PG Clamp Panther to Panther
Spacer for 250mm spacing for Twin Moose Conductor 02 bolted complete with hot dip galvanized nut, bolts & washer as per technical specification.
Spacer for 100mm spacing for Twin Moose Conductor 02 bolted complete with hot dip galvanized nut, bolts & washer as per technical specification.
33 KV Circuit Breaker clamp suitable for Twin Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
33 KV CT clamp suitable for Twin Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
Bolted type single gun, Tension fitting for Panther Conductor suitable for 1x10 No Disc insulators complete with hardware set as per technical specification.
Bimetallic terminal connector for 40MVA T/F HV side bushing rod 30 mm dia. made of aluminum alloy LM-6 suitable for ACSR Zebra /Moose conductor of matching with bushing rod complete with hot dip galvanized nut & bolts as per technical specification.
Bimetallic terminal connector for 40 MVA T/F LV side bushing rod 30 mm dia. made of aluminum alloy LM-6 suitable for Twin Zebra /Moose conductor matching with bushing rod complete with hot dip galvanized nut & bolts as per technical specification.
Supply of 33 KV bolted type tension fitting for Twin Moose conductor 1x4 No. disc insulator with turn buckle complete with hardware fitting d-sackle, d-socket, ball hook, yoke plate, d-clip it tension clamp etc. as per technical specification.
Supply of 33 KV bolted type tension fitting for Twin Moose conductor 1x4 No. disc insulator without turn buckle complete with hardware fitting d-sackle, d-socket, ball hook, yoke plate, d-clip it tension clamp etc. as per technical specification.
33 KV LA Clamp for ACSR Panther Conductor Complete with HDG nuts & bolts and washer as per technical specification.
33 KV PT Clamp for ACSR Panther Conductor Complete with HDG nuts & bolts and washer as per technical specification.
33 KV Isolator clamp suitable for Twin Panther conductor one side connecting the Panther conductor and another side a plate with 04 Nos. 12mm dia. hole as per technical specification.
33 KV Section Isolator clamp suitable for Twin Moose conductor one side connecting the Moose conductor and another side a plate with 04 Nos. 12mm dia. hole as per technical specification.
Spacer for 60mm spacing suitable for Twin Panther conductor 01 bolted made of aluminum alloy LM-06 complete with hot dip galvanized nut bolt and washer as per technical specification.
M/s S.S. Refregeration
M/S JAI SHREE ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .