Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LAccepted-Finance | L1 | Accepted-Finance being L1 | |
| 2 | L2₹2.7 L+₹9,500 (3.68%)Rejected-Finance | L2 | Rejected-Finance being L2 | |
| 3 | L3₹2.8 L+₹17,055 (6.60%)Rejected-Finance | L3 | Rejected-Finance being L3 |
Tender Value
Refer Docs
Closing Date
22 Sept 2021, 6:00 pmClosed
GE WEST HISAR
Hisar Mil Stn Hisar - 125006
3077/JOB/03/E3/20-21 PROVN OF 3 PH ups for OT and ICU including external and internal EM service for new oxygen plant
2021_MES_475375_1
3008/JOB/03/E3
Limited
Job Works
Works
60 days
Garrrison Engineer (West) HISAR MILITARY STATION
As per job document
3 documents required · 3 mandatory
₹0
Exempted
27 Sept 2021
15 Sept 2021
24 Sept 2021
15 Sept 2021
22 Sept 2021
16 Sept 2021
15 Sept 2021 - 16 Sept 2021
Amount
PROVISION OF THREE PHASE UPS FOR OT & ICU AND INCLUDING EXTERNAL AND INTERNAL E/M SERVICES FOR NEW OXYGEN PLANT AT MH HISAR
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core. (A/U- RM, Qty-60)
M&L Earthing of machinery/equipment installed at power house/substation using 32 X 6 mm galvanised strip and Galvanised steel earth plate electrode of size 600 x 600 x 6.3 mm as earth electrode burried directly in ground to a depth not less than 2.25 meters deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all arround the plate, using galvanised iron stip 32 X 6 mm as earth strip electrode bolted or revetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate up to equipments, 20 mm dia bore GI pipe 'light grade'as water pipe from each chamber to upper edge od earth plate, test point, GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 TYPE B-1 (Using 20 mm graded stone aggregate ) as in pit chamber and RCC pit cover 50 mm thick precaust RCC 1:2:4 type B-1, duly reinforced with MS round bars 6 mm dia @ 100 c/c both ways 10 mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electrical plate No.3 of SSR part-I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (A/U- Each, Qty-02)
M&L submain wiring with 2 runs of single core 04 sqmm PVC insulated unsheathed multistranded 1100 volts grade with FRLS copper conductor drawn through and including ISI marks PVC surface conduit and conduit accessories of medium grade not less than 25mm dia including one run of single core 4 sqmm FRLS PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth conductor along with wiring and connected from DB to DB/main board complete all as specified and directed. Note :- Two run of 4 Sqmm cable and one run of 4 Sqmm earth cable and one run of 25mm PVC conduit shall be considered as a unit for measurements purpose. (A/U -RM, Qty - 20)
Supply & fixing in replacement LED flood light luminaries of cap 80 watt ,SPD-10KV external with lense, 240 volt,Pressure die cast housing with IP 65 protection, heat resistant toughtened clear glass with frame complete with accessories , pre wired up to a terminal block and mounting attachment,including pvc connector for connection complete all as specified. (A/U -Each, Qty - 06)
M&L for point wiring with 1.5Sqmm PVC insulated and unsheathed FRLS single core multistranded copper conductor point in and including PVC rigid non metalic surface conduit 19/20mm dia, medium duty, ISI marked to be teminated in pressed steel terminal boxes including 1.5Sqmm PVC inslulated and unsheathed FRLS single core multistranded copper earth continuity conductore controlled by one witch and / or one regulator complete for following items complete all as specified and directed :- (a) One light /Ceiling fan/Exhaust fan point controlled by one Switch. (A/U -Per point, Qty - 08) (b) One 3/5 pin switch socket 5/6 Amps on same board. (A/U - Per point, Qty - 01)
M&L for point wiring with 2.5 Sqmm PVC insulated and unsheathed FRLS single core multistranded copper conductor point in and including PVC rigid non metalic surface conduit 19/20mm dia, medium duty, ISI marked to be teminated in pressed steel terminal boxes including 2.5Sqmm PVC inslulated and unsheathed FRLS single core multistranded copper earth continuity conductore controlled by one witch and / or one regulator complete for following items complete all as specified and directed. (A/U -Per point, Qty - 01)
Supply & fixing switch piano 5 Amps, single pole, AC, 230 Volts, flush type, ISI Mark,complete all as specified and directed (A/U -Each, Qty - 09) Supply & fixing switch piano 15 Amps, single pole, AC, 230 Volts, flush type, ISI Mark,complete all as specified and directed (A/U -Each, Qty - 01)
Supply & fixing Socket 15-2/3 pin, single pole, AC, 230 Volts, flush type, ISI Mark,complete all as specified and directed (A/U -Each, Qty - 01)
Supply and fixing Box type LED lights fitting 1x 18 W, 220V, AC box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. (A/U -Each, Qty - 02)
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of SPN current carrying capacity 32 AMP, in the MCB DB Complete with connection testing and commissioning (A/U -Each, Qty - 01)
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5-32 AMP, in the MCB DB Complete with connection testing and commissioning (A/U -Each, Qty - 06)
Supply and Fix of MCB SPN DB , 8 way with 200 amps tated bus bar 240 volts double door with isolated Neutral bar & Shrouded bus bar IP protection 43 having door earthing complete all as specified and directed by Engr charge. (A/U -Each, Qty - 01)
Excavation in trenches in soft/loose soil n. exc. 1.5 mtr deep and not exceeding 1.5 mtr in width for laying LT cables complete all as specified and as directed. (A/U -Cum, Qty - 8.4)
Removal of surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr from starting point complete all as specified and as directed. (A/U -Cum, Qty - 2.835)
Returning filling in including spreading, levelling watering and well ramming in layers not exceeding 25 cm thick in any type of soil after the existing water pipe lines have been taken up/out and new existing pipe line laid and tested complete all as specified and directed. (A/U -Cum, Qty - 5.562)
Material & labour for Sand filling in trenches with clean dry fine sand unwashed including gently punning around cables complete (A/U -Cum, Qty - 2.835)
Material & labour for bricks covering to under ground electric cable using sub class 'B' bricks laid dry, flat, perpendicular to the direction of the cable complete all as specified and directed. (A/U -Each, Qty - 280)
M/s R.S Traders
fauji electric works
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_530358.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .