Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.9 LAccepted-AOC FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹33.9 L+₹48,578 (1.46%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹36.4 L+₹3.1 L (9.20%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
2 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Khadakwasla
GE Khadakwasla NDA Khadakwasla Pune-411023
REPAIRS TO CERTAIN BR AND EM WORKS AT NO 5 BN ATT HOR SWIMMING POOL JTT AND RAKESH SHARMA BLOCK ETC AT NDA KHADAKWASLA
2023_MES_602980_2
8710/E8
Open Tender
Civil Works
Item Rate
180 days
GE Khadakwasla
As per Tender documents
9 documents required · 9 mandatory
₹500
GE Khadakwasla
₹70,000
Yes
31 Aug 2023
14 Jul 2023
4 Aug 2023
14 Jul 2023
2 Aug 2023
21 Jul 2023
14 Jul 2023 - 20 Jul 2023
Amount
S&F in repairs SS Butt hinges, heavy weight, cold rolled, mild steel length of hinges 100 mm etc all as specified and as directed.
S&F in repairs SS Butt hinges, heavy weight, cold rolled, mild steel length of hinges 125 mm etc all as specified and as directed.
S&F in repairs extruded aluminium alloy Plate handle 'D' Type fabricated type anodized 150 mm long etc all as specified and as directed.
S&F in repairs Aluminum alloy anodized sliding door bolt 250mm long with hasp and staple (bolt type) and fixing bolts and sliding bolts of extruded such or cast aluminum alloy etc all as specified and as directed.
S&F in repairs Brass sliding door bolt 300mm long with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed all as specified and as directed.
S&F in repairs Aluminum anodized barrel tower bolt of extruded section 150mm long etc all as specified and as directed.
S & F in repairs 150 mm aluminium anodised barrel tower bolts, stove enamelled black, with bright bolt and fixed etc all as specified and as directed.
S&F in repairs door stopper aluminium anodized white dale 40mmx40mm and 2mm thick dia 150mm having rubber bash 25mm dia long (high) at end the sheet/fixed to door shutter with steel cadmium places screw all as specified etc all as specified and as directed.
S&F in repairs Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete etc all as specified and as directed.
S&F in repairs steel curtain rod 20mm dia fixed including fancy type brackets and 6 hooks for each rod complete for fixing in repair etc all as specified and as directed.
Resecuring or easing & adjusting without taking down shutters of any description n.exc 1 sqm each . Note : (i) The rates for necessary scafolding required shall be deemed to be included.
Resecuring or easing & adjusting and refixing in same opening including taking down shutters if necessary, necessary grinding, sanding, repair/replacement of damaged rail/panel of any description n.exc 2 sqm each . Note : (i) Rate deemed to be inclusive of 1st class hardwood plain panel, style, rail required to be replaced of size matching wih existing and making the surface good by necessary polishing/painting/oiling (ii) The rates for necessary scafolding required shall be deemed to be included.
Hacking out old broken glass (any thickness, size,quality or description) from wooden frames glazed with putty or fixed with beads complete all as specified and directed.
S&F 3mm thick glass sheet ordinary quality and glazing with oil putty fixed with beads n.exc 0.5Sqm in each pane complete all as specified and directed.
S&F 4 mm thick one side ground glass sheet ordinary quality and glazing with oil putty/ wooden beading n.exc 0.5Sqm in each pane complete all as specified and directed.
S&F Rough cast, wired figured glass, 6.4mm thick and glazing with oil putty in squares n exc 0.5 sq.m in each pane complete all as specified and directed..
Taking down shutters of any description n.exc 1 Sqm each complete all as specified and directed.
All as per item No 17 above but exc 1 Sqm and n.exc 2 Sqm each as directed.
Taking down chowkhats or frames but with shutters (without taking off shutters from the frames) exc 1 Sqm and n exc 2 Sqm each complete all as specified and directed.
Taking down chowkhats or frames but with shutters (without taking off shutters from the frames) exc 1.5 Sqm and n exc 4 Sqm each complete all as specified and directed.
S&F 2nd class hardwood Plain, framed,panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, 30mm thick all as specified and directed
S&F 30mm 2nd class hard wood glazed and skeleton shutter open rebated and prepared to receive glass gauze, etc. ( without sash bars) edges of framing plain, chamferred or rounded fitted with cut and mitered bends for securing glass etc size of members of shutters as specified in as Part I Ses 8 Cl 8.20 (a), complete all as specified and directed.
S&F 30mm thick Flush shutters, solid core construction, with particle board core , if both facescovered with decorative face laminates with lipping/frame to match complete all as specified and directed.
S&F PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, suplying & fixing in the frame at site complete all as specified and directed.
Taking down existing aluminum chowkats or frames of any description and in any position not exceeding 4 sqm each with shutter (w/o taking off shutter from the frames) complete all as specified and directed.
S&F, Powder coated (minimum thickness of powder coating 50 mm micron) aluminium frame & shutter for door, window and ventilator including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, hinges, tower bolt, etc complete all as specified & directed Note :- Floor door spring & sheet glass shall be measured and paid seperately under respective items
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete etc all as specified and as directed.
S&F 5.5 mm thick sheet glass, ordinary quality and glazing in squares not exceeding 0.5 Sqm in each pane complete all as specified & directed
S&F 5.5 mm thick sheet glass, ordinary quality and glazing in squares exceeding 0.5 Sqm in each pane complete all as specified & directed
S&F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturs complete all as specified & directed
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed
S&F SS Butt hinges, heavy weight, cold rolled, mild steel length of hinges 75 mm etc all as specified and as directed.
S&F SS Butt hinges, heavy weight, cold rolled, mild steel length of hinges 125 mm etc all as specified and as directed.
S&F SS Butt hinges, heavy weight, cold rolled, mild steel length of hinges 100 mm etc all as specified and as directed.
S&F 150 mm aluminium anodised barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and directed.
S&F extruded aluminium alloy plate handle 'D' Type fabricated type anodized 150 mm long complete all as specified and directed.
S&F Aluminum alloy anodized sliding door bolt 250mm long with hasp and staple (bolt type) and fixing bolts and sliding bolts of extruded such or cast aluminum alloy etc all as specified and as directed.
All as per item no. 38 above but 300mm long.
S&F in repairs 2nd class hardwood Plain fillets. square, rectangular or triangular in section , clean sawn, secured with nails or brads fixed in repairs.exc 3 sq cm & n exc 6 sqcm complete all as specified and directed.
S&F in repairs 2nd class hardwood Plain fillets. square, rectangular or triangular in section , clean sawn, secured with nails or brads fixed in repairs.exc 6 sq cm & n exc 13 sqcm complete all as specified and directed.
M&L for painting two coats of Synthetic enemal paint over a coat of pink primer on new wooden surfaces complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets etc.complete all as specified and directed.
M&L for 4mm thick Non Asbestos fibre cement plain sheet 600 x 600 for ceiling on anodized aluminium grid work 610 x 610 mm with using 36.5mmx23.5mmx1.5mm thick main tee, 23.5 x23.5mmx1.28mm cross tee and 25x25x1.5mm angles fixed to perimeter of wall for false ceiling including necessary supporting hanger with 3.0mm dia GI wire and 'J' bolts washer nuts for securing frame work to ceiling suspended @ 120 cm C/C both ways, size of grid shall be 610x610mm complete all as specified and directed.
S&F asbestos cement plain building boards 4mm thick, fixed to timber /GI/MS framework with screws complete all as specified and directed.
M&L for anodised aluminium snap grid 605 x 605 mm frame work for false ceiling includingexposed metal frame ceiling with 8mm calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mm x 600mm grid complete all as specified and directed.
S&F in repairs 12mm thk Prelaminatd particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame /snap grid work complete all as directed.
Dismantling timber scantling 40 Sqcm and over in section and at any position as in unframed work complete all as specified & directed.
M&L for 2nd class hard wood clean sawn battens at 30 cm centre, sectional area exc 5 & n.exc 15 sqcm complete all as specified & directed.
M&L for 12 mm thick plywood, grade BWP type BB fixed with screws to timber frame work complete all as specified & directed.
M&L for 0.9 mm thick decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacture's instruction complete all as specifird & directed.
S&F in repairs stainless steel wiremesh 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with wooden beads complete as specified and directed
S&F in repairs Toilet paper holder of stainless steel fixed in repair to walls with chromium plated brass screws complete etc all as specified and as directed. Make : M/S Cera Cat part No F5007110, M/S Shri Laxmi Industries (P) Ltd, Classic or equivalent
S&F in repairs brass chromium plated tubular towel rail 30mm dia D type 60cm long between flanges etc complete all as specified and directed. Make : Cera Cat part No F5006103 or equivalent in makes as mentioned at makes list in PS
S&F in repairs heavy duty Plantex high grade stainless steel towel rack 600mm long with lower hanferan hooks fixed on wall complete all as specified and as directed. Make : Cera cat Part No F5003101 Ormond range, Parryware, Hindusthan sanitary ware industries or equivalent
Taking down SWG/rainwater pipes 100mm dia (any size or pattern), including all fittings,heads, shoes, bends, swan-necks, etc., complete all as specified and directed.
S&F 110mm dia PVC (SWR) grade Type B, single socketed pipes in any length complete with rubber ring joints fixed to wall etc using synthetic rubber adhesive cement solvent complete all as specified and directed
S&F 110mm dia PVC (SWR) bends any radius complete all as specified and directed
Dismantling of cast iron 100/75 mm bore pipes jointed in cement motar including all fittings complete all as specified and directed
S&F for providing cast iron soil & waste and vent spun pipes in any length with or without ears with cement joints fixed to walls using pipes 100mm bore pipes etc complete all as specified and as directed.
S&F for providing cast iron soil & waste and vent spun pipes in any length with or without ears with cement joints fixed to walls using pipes 75mm bore pipes etc complete all as specified and as directed.
S&F CI bend 100 mm bore with oval access door etc complete all as specified and as directed..
S & F 100 mm size branch piece , single (equal or unequal) ordinary or inverted (spigot or socket type) or with parellel branches etc complete all as specified and as directed..
S&F CI cowl 100 mm size etc complete all as specified and as directed.
S&F in repairs 110mm dia PVC (SWR) bends any radius complete all as specified and directed
S&F in repairs 110mm dia PVC (SWR) junction single(single T), Type B complete all as specified and directed
S&F in repairs 110mm dia PVC (SWR) branch piece, single (single Y) equal or unequal, Type B, complete all as specified and directed
S&F in repairs 110mm dia PVC (SWR) Type B vent cowl complete all as specified and directed
S&F 75mm dia PVC (SWR) grade, Type B, single socketed pipes in any length complete with rubber ring joints fixed to wall etc using synthetic rubber adhesive cement solvent complete including taking down of existing pipe all as specified and directed
S&F 75mm dia PVC (SWR) Type B, bends any radius complete all as specified and directed
S&F in repairs PVC low level flushing cistern including brackets 10 litre capacity with inlet ball valve float, handle,flush pipe etc. complete fixed as in repairs etc complete all as specified and as directed. Make : Cera Cat part No B1010107 or or equivalent in makes as mentioned at makes list in PS
S&F in repairs wash hand basin (match to existing) vitreous china white (flat back) of size 550x400mm including 15 mm dia pillar cock , CI bracket 15mm dia polythene connection , 32mm dia waste coupling and 32mm dia PVC waste pipe 90cm long etc. complete all as specified and directed
S&F in repairs white vitreous china wash down water closet pan (pedestal pattern) with mild steel chromium plated or aluminised hinging device including connection to drown pipe and flushing pipe complete all as specified and directed
S&F in repairs Vitreous water closet (squatt pattern) 'long pan', size 580/630mm white with 'P' or 'S' trap, front or back inlet any pattren complete all as specified and directed
S&F in repairs SS gratings 100/125mm dia complete all as specified and directed
S&F in repairs PTMT gratings 100/125mm dia complete all as specified and directed
S&F in repairs vitreous China urinals, half stall (match to existing) type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed
S&F urinal spreader of CP cast copper alloy for fixing with 15 mm dia pipe. (match to existing fittings) complete all as specified and directed
S&F 32mm dia waste coupling suitable for urinals of SS (half or full threaded) (minimum -weight 32mm-45 gram) complete all as specified and directed
S&F 32mm dia PVC (flexible) waste pipe for wash hand basin completecomplete all as specified and directed
S&F in repairs 32mm dia waste coupling suitable for WHB of SS (half or full threaded) (minimum -weight 32mm-45 gram/40 mm-60gms complete all as specified and directed
S&F in repairs 32mm dia waste coupling suitable for urinals of SS (half or full threaded) (minimum -weight 32mm-45 gram) complete all as specified and directed
S&F in repairs 32mm dia PVC (flexible) waste pipe for wash hand basin complete complete all as specified and directed
S&F 15 mm PVC connections 15 mm size with PTMT nuts of length 375 mm complete all as specified and directed
S&F in repairs 15 mm PVC connections 15 mm size with PTMT nuts of length 375 mm complete all as specified and directed
S&F in repairs for providing urinal valve auto closing system with built in control cock & wall flange, cast copper alloy chromium plated 15mm fancy type, screwed down for iron pipe or for brass ferrule complete all as specified and directed . Make : Jaquar Cat part No PRS-CHR-077 or equivalent in makes as mentioned at makes list in PS
S&F in repairs for providing two way bib cock cast copper alloy fancy type screwed down high pressure with cruntch or butterfly handle, screwed both ends for iron pipe or for union and fixed for 15mm bore of pipe with long shunk and cup complete all as specified and directed. Cat Part No - CERA Cat No F1015163 or equivalent in makes as mentioned at makes list in PS
S&F in repairs for providing long body bib taps with wall flange ,cast copper alloy chromium plated 15mm fancy type with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specified and directed. Cat Part No - CERA Cat No F2002152 or equivalent in makes as mentioned at makes list in PS
S&F in repairs 15mm dia brass ball valve high pressure with float and fly nut complete, screwed for iron pipe or brass ferrule & fixed complete all as specified and directed
S&F in repairs 20mm dia brass ball valve high pressure with float and fly nut complete, screwed for iron pipe or brass ferrule complete all as specified and directed
S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed Make - Cera cat part No 8030104 , Jaguar ALD CHR-593 or equivalent in makes as mentioned at makes list in PS.
S&F in repairs stay, suitable for health faucet complete all as specified and directed.
S&F in repairs CP Knob, suitable for basin mixture complete all as specified and directed.
S&F in repairs for stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed for bore of size 15mm dia complete all as specified and directed . Make : Cera cat part No F8040204 or equivalent in makes as mentioned at makes list in PS
S&F in repairs 15mm pillar taps, cast copper alloy with captain heads chromium plated screw down high pressure with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed Make : Cera cat part No F2002103, or equivalent in makes as mentioned at makes list in PS
S&F in repairs brass chromium plated shower rose 125mm size complete all as specified and directed
S&F in repairs plastic water closet seat, cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed
Taking down up or down steel tubing and connections incl cleaning for re-fixing or removal to stores ,15mm dia pipes complete all as specified and directed .
Ditto all as per item no. 100 above but 20mm dia pipes.
S&F galvanised mild steel medium grade tubes 15mm dia bore with all fittings and fixed to wall , floor etc.. complete all as specified and directed
Refixing old steel tubing and conection in new or old position on wall, ceiling, floor etc.. 15 mm bore pipe complete all as specified and directed .
S&F galvanised mild steel medium grade tubes 20mm dia bore with all fittings and fixed to wall, floors etc.. complete all as specified and directed
Refixing old steel tubing and conection in new or old position on wall, ceiling, floor etc.. 20 mm bore pipe complete all as specified and directed
S&F in repairs PVC flush tank ball cock set complete all as specified and directed.
S&F in repairs 20 mm bore GI tank nipple complete all as specified and directed.
S&F in repairs 15 mm bore GI tank nipple complete all as specified and directed.
S&F in repairs spindle for 15mm/20mm CP / brass bib cock, stop cock & concealed stop valves, WHB mixtures etc complete all as specified and directed.
S&F in repairs 15 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe complete all as specified and directed
S&F in repairs 20 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe complete all as specified and directed
S&F in repairs 25 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe complete all as specified and directed
S&F in repairs 40 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe complete all as specified and directed
S&F in repairs door closer hydraulically regulated,aluminium (die cast) body ,universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed
Repairs to aluminium door / window by removing from position and fixing in same position by reparing in all means. Area not exceeding 1.50 Sqm each complete all as directed.
All as per item No 115 above but area exc 1.50 sqm and n exc 4.00 sqm each. NOTE For Item No- 115 & 116 :-New aluminium section requried for replacement shall measured and paid separately under respective item.
Taking down cement plaster of any description incl racking out joints hacking for key and scrubbing down with water to remove dust etc.complete all as specified and directed
M&L for rendering 15 mm thick plaster in CM (1:6) on wall surface finished even and smooth without using extra cement complete all as specified and directed
M&L for newly plaster surface on wall and applying two coats of distemper oil emulsion over a priming coat with chalk whiting preparatory to distembering complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
M&L for coloured Glazed ceramic tiles in vertical surface 300x 200x 7mm or 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick backing coat in CM 1:4 etc complete all as specified and directed
M&L for coloured Glazed ceramic tiles (200x200mm) x 7mm thick, in floors or wall surfaces etc. set and jointed in neat cement slurry and pointed in white or colour cement to match over or backing coat 15 mm thick screed bed in CM 1:4 etc complete all as specified and directed .
M&L for coloured Glass Mosaic tiles (300x300mm) x 7mm thick, in vertical/ floors etc. set and jointed in neat cement slurry and pointed in white or colour cement to match over 15 mm thick backing coat/screed bed in CM 1:4 etc complete all as specified and directed
M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:4 etc complete all as specified and directed
M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:4 etc complete all as specified and directed
M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:4 etc complete all as specified and directed
M&L for 300X300X10mm thick glazed designer dura stone tiles of any approved colour, heavy duty machine pressed including 15 mm thick screed bed of CM (1:6) in floors ccomplete all as specified and directed
M&L for Vitrified (double charged) ceramic tiles 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floor etc set jointed and pointed in white or coloured cement to match the colour of tiles with screed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6. complete all as specified and directed
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc laid beded & pointed any type of morter complete all as specified and directed
M&L for 16 to 18mm thick granite (of any type any colour) work (table rubbed 7 polished ) in window door cills/jambs, platform like in cement morter (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shed with granite etc complete all as specified and directed
M&L for 16mm thick granite both side polished for urinal partition / vertical surfaces etc. in cement morter 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shed with granite etc complete all as specified and directed
M&L for Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed
M&L for granite work (black, lakha red, flamed where ever necessary) (table rubbed 7 polished ) thick granite stone slab (of any type ) work (table rubbed and polished ) as in floor, steps, jambs, pillars, window cills, laying over 15mm thick CM 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting and making good for disturbed surfaces and chamfering for exposed edges,surfaces complete all as specified and directed
M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and including polishing complete over and including 20mm thick screed in CM 1:4 complete all as specified and directed
M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and including polishing complete over and including 15mm thick screed in CM 1:3 all as directed .
M&L for pre-polished coloured Chequered cement concrete tiles 20cm x 20cm x 25mm or 25cm x 25cm x 25mm or 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry with grey cement and pigments over 20 mm thick screed bed in CM 1:6 in floors complete all as directed and as specified.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as directed and as specified.
S&F in repair Co-polymer Poly-propylene (CP-PP) white swimming pool overflow pin grating size 100mm to 400mm width, match to existing pin complete all as specified and directed.
Taking up/down plants or vegetation growth from wall upto roof level by means of cutting hole into brick wall and making good the surface of dismantled portion (not exc 150 sq cm superfical area and not exc one brick depth) using brick bats /aggregate and plastering in cement mortar (1:4) to distrubed portion and applying two coats of cement base paint / weather coat to match the existing surface upto forth floor complete all as specified and directed
M& L for sunken treantment to Floors of toilets/Baths/WCs/Kithcen as under :- (a) Clean the sunken portion of toilet/Bath/WC/Kitchen throughly to remove laitance, dirt, dust, etc. (b) Form angle fillet of size 40 mm x 40 mm along the junction of wall and floor using polymer modified mortar ("Dr Fixit" Pidicrete URP" or eqvt) (c) Sanitary pipes entering through walls and floor shall be sealed with "Dr Fixit Bathseal Tape" and the gaps to be grouted with non-shrink cementitous grout "Dr Fixit Bath seal Grout" or eqvt. Nahani traps, etc to be fitted securely and the gaps around it to be grouted in the same manner. (d) Apply one coat of a Bitumen-modified polymer coating "Dr Fixit Bathseal Plus" or eqvt on all angle fillets by brush and cover it with 100 mm open woven mesh when it is still wet. Apply second coat of the same coating on the angle fillets and allow it to dry completely. (e) In the remaining area, in dry sustrate condition brush apply first coat of the same coating and further apply second coat when first coat is dry. Extend the coating upto 150 mm above the FFL. Above FFL, another cementitious waterproof coating "Dr Fixit Pidifin 2 K" or eqvt can be further applied right upto 2.1 mm to waterproof the shower area also, it is a bathroom or bath cubicles of a sanitary annex and apply second coat after 6-8 hours and allow to dry completely. (f) After 2 to 3 days, sunken portion must be overlaid with a 50 mm thick concrete screed M 15 type B0 mixed with intergral WPC (Liquid) laid to slope 1:60 towards outer face of wall. Provide 40 mm OD UPVC pipe at the lowest point with 300 mm projection beyond the outer face of the wall. Then fill up the sunken portion with lean concrete 100mm 1:5:10 type E2.
S&F Framed work for framed chajja, grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete including dismantling of exiting all as specified and directed
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges:large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete including dismantling of exiting all as specified and directed
S&F in repairs 1mm Plain, galvanised, mild steel sheeting in stepped flashings (measured as the minimum rectangle from which the pie-ces can be cut) complete all as specified and diredted.
S&F in repairs 2nd class hardwood timber in clean sawn battens or fillets complete all as specified directed.
M&L for complete removal of existing treatment from wall to make the surface free from dust, loose paint and loose plaster by scrapping manually / mechanically as directed by engr-in-charge (nails, screws if any to be removed properly before scraping) complete all as specified and directed.
All as per item No 145 above but for Ceiling surface complete all as specified and as directed.
M&L for providing and applying water proof cement base putty of 1mm thick over prepared old plastered / old painted surface to prepare the surface even and smooth upto desired finishes by manually / mechanical means etc complete all as specified and directed.
All as per item No 147 above but for Ceiling surface complete all as specified and as directed.
M&L for one coat of acrylic water based interior grade primer @ 0.8 ltr (undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied on wall with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface for painting of subbsequent coats complete all as specified and directed.
All as per item No 149 above but for Ceiling surface complete all as specified and as directed.
M&L for applying two coats of oil bound distemper on wall using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper shall be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed.
All as per item No.151 above but for Ceiling surface complete all as specified and as directed.
M&L for preparation of old surfaces (plastered or unplastered) of walls including cornices, with Mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint and finished surface smooth, etc. by skilled labour and applying one coat of oil bound distemper on wall using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed.
All as per item No 153 but for Ceiling surface complete all as specified and as directed.
M&L for one coat of acrylic water based exterior grade primer on wall @ 0.9 ltr (undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed.
M&L for Two coats water based premium acrylic smooth exterior emulsion paint on wall of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti fangal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint complete all as directed.
M&L for preparing old surface with Mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint and finished surface smooth, etc. by skilled labour and applying One coat of water based premium acrylic smooth exterior quality emulsion paint on old wall surfaces of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti fangal properties in one coat @ 0.75 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over preparing surfaces with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. etc complete all as specified and directed.
M&L for preparation of old wooden surface smooth with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc or flaming polish which ever is suitable for site and fill the gap or crack with wood filler, POP or putty etc by removing latches / sliding door bolt and refixing the same in the door and applying one coat of synthetic enamel paint exc 10 cm width or girth with fully automatic airless spray machine complete all as specified and directed.
M & L for one coat of synthetic enamel paint with fully automatic airless spray machine including preparation of old painted surfaces of wood, wood based surfaces, AC sheet in ceiling exc 10 cm width or girth etc in ceiling incl filling of gaps between wooden planks with putty,POP complete all as specified and directed.
M&L for preparing the old wooden surfaces of any description, with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc or flaming polish which ever is suitable for site and fill the gap or crack with wood filler, POP or putty etc by removing latches / sliding door bolt and refixing the same in the door and apply one or more coats of french polishing till the desired finish is obtained complete all as specified and directed.
M&L for preparation of old treated wooden Surfaces of any description, over 10cm in width or girth, fill the gap or crack, hole with wood filler or POP, putty etc including cleaning and make the surface smooth and applying One coat Varnishing etc till the surface became fine glosy finish complete all as specified and directed.
M&L for one coat of aluminium paint incl preparation of old painted steel surfaces exc 10 cm width or girth complete all as specified and directed
M&L for one coat of synthetic enamel paint incl preparation of old painted steel surfaces exc 10 cm width or girth complete all as specified and directed
M&L for one coat of Subsequent cement based paint on wall surfaces incl preparation of old treated surface complete all as specified and directed.
M&L for one subsequent coat of white washing on Ceiling surfaces incl preparation of old treated surface complete all as specified and directed.
M&L for preparation of old steel surfaces over 10cm width or girth and applying two coats of polyurethane paint over one coats of epoxy rich primer (grey/red) complete ass as specified and directed.
Repair / maintenance of internal light fitting of any type like tube lights / wall bracket light fittings / ceiling lights / bulk head light / mirror lights incuding switches etc in its position, testing all the compenents / parts, wiring etc, identifying and replacing the defective components like tube rod, side holders, holders, lamps, switches, sockets, ceiling roes, etc all as directed by Engr-in-charge. Note: (i) The rate against the above mentioned item is deemed for cost of labour only. (ii) Cost of spares like capacitor, lamp holder, connector, connection wire, switches, sockets, ceiling roes etc. replaced against above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below. (iii) The contractor's representative will report to concerned JE E/M at 0900hrs daily to collect the list of defects and will submit the completion report on following day before 0900hrs to the JE E/M. (iv) The contractor shall rectify the defects and make the light fittings functional within 24 hours from the time the list of defective lights is handed over to him / his rep by the concerned JE E/M. In case the light fitting is not made functional for whatsoever reason within the specified time limit, an amount of Rs 100/- per such defective light fitting per day will be recovered from the amount due to him through RAR / Final Bill.The contractor shall engage separate team of technicians / repairer for each at NO 5 BN, ATT, HOR, SWIMMING POOL, JTT AND RAKESH SHARMA BLOCK (v) The contractor shall maintain proper record of repair / maint in a binded compliant register and complaint slip books duly signed by the user and bringing out the details of spares replaced and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (vi) The contractor shall maintain sufficient stock of spares / material required for repair / maint of light fittings with the concerned JE E/M against the supply only items here-in-below.
Supply only following spares for light fittings of branded make as mentioned in the list of make enclosed with Particular specifications for replacement :- (a) Spring loaded G13 side holders (set of 2) suitable for 36/40W FTL fitting
(b) PVC /polycarbonate lamp holders batten/Angle type
© Supply only switch piano flush type 5 Amps SP one way all as specified.
(d) Supply only switch piano type 15 Amps SP one way all as specified.
(e)Supply only socket 5/6 Amps flush mounted 3 pin all as specified.
(f) Supply only socket 5/15 Amps flush mounted 3/5 pin multi purpose all as specified.
(g) Supply only ceiling rose, 2 to 3 terminals /PVC/Polycarbonate, isolated body.
S&F in replacement modular step type fan regulator 120W, 2 module complete all as specified and directed.
S&F in replacement modular switch piano type 10 amps one way one module complete all as specified and directed.
S&F in replacement modular switch piano type 20 amps one way one module with neon indicator complete all as specified and directed.
S&F in replacement modular Socket, 6A - 2/3 pin 2 module complete all as specified and directed.
S&F in replacement modular Socket, 6/16A - 2/3 pin 2 module complete all as specified and directed.
S&F in replacement of 1 module Blanking plates complete all as specified and directed.
S&F in replacement of switch socket combination 5/6 Amps flush mounted 5 pin multi purpose complete all as specified and directed.
S&F in replacement of switch socket combination 5/15 Amps flush mounted 3/5 pin multi purpose complete all as specified and directed.
M&L in replacment of fan regulator electronic step type suitable for 1200/1400 mm sweep fan as per the sample provided complete all as specified and directed.
M&L in replacement of door bell AC 230 volts single phase ding dong type complete all as specified and directed.
M&L in replacement bell push, flush type 5 Amps complete all as specified and directed.
S&F in replacement of switch socket combination with box 5/6 Amps flush mounted 5 pin multi purpose complete all as specified and directed.
S&F in replacement of switch socket combination with box 5/15 Amps flush mounted 3/5 pin multi purpose complete all as specified and directed. .
Taking down carefully copper/aluminium point wiring (light/fan/socket) including all accessories wire, casing caping/conduit, screws etc and making good the disturbed surfaces complete all as specified and directed.
M&L point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metalic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type switches, sockets, fan regulator etc for following :- (a) One light/Fan point controlled by one way switch 6 Amps 240 volts
(b) All as per item no. 189 above but One 3 pin 6 Amps socket out let point on independent board.
(c )All as per item no. 189 above but One 3 pin 6 Amps socket out let point on same board.
(d) All as per item no. 189 above but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq mm size.
M&L point wiring with 2.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unseathed cable and including surface, Non metalic rigid PVC casing capping double lock type ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLSH cable size 2.5 sq mm copper conductor as earth wire to common earth dolly including PVC box , modular cover plate with frame suitable for 15 Amps socket and switch outlet power point independent circuit complete all as specified and directed.
M&L for point wiring in and including new concealed PVC conduit medium grade with the help of multi-stranded unsheathed FRLS copper cable 1.5 sqmm 650/1100V conforming IS : 3419 -1988 adhereing to colour code including earth wire of the size 1.5Sqmm green colored with terminal boxes as required at site steel or cast iron as indicated and shall conform to IS 14772-2000 including making good the distrubed surfaces and matching it with existing surface including PVC box , modular cover plate with frame complete all as specified and directed. :- (a) One light/Fan point controlled by one way switch 6 Amps 240 volts complete all as specified and directed.
All as per item no. 194 above but One 3 pin 6 Amps socket out let point on independent board.
All as per item no. 194 above but One 3 pin 6 Amps socket out let point on same board.
All as per item no. 194 above but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq mm size.
M&L for point wiring in and including new concealed PVC conduit medium grade with the help of multi-stranded unsheathed FRLS copper cable 4sqmm 650/1100V conforming IS : 3419 -1988 adhereing to colour code including earth wire of the size4 Sqmm green colored with terminal boxes as required at site steel or cast iron as indicated and shall conform to IS 14772-2000 including making good the distrubed surfaces and matching it with existing surface including PVC box , modular cover plate with frame suitable for 15 Amps socket and switch outlet power point independent circuit complete all as specified and directed.
M&L for secruing loose wiring and repair to point wiring with necessary rigid non metalic PVC casing caping double lock type/ PVC conduit ISI marked of size not less than 25 mm inclusive all accessories complete as specified and directed.
S&F flexible conduit pipe ivory grey in colour of dia not less than 25 mm complete all as specified and directed.
M&L for sub main wiring with two single core PVC insulated FRLS cables with stranded copper conductors 1.5 Sqmm , 1100 Volts grade in and including PVC Conduit/casing caping medium grade not less than 25 mm complete with conduit accessories and copper cable 1.5 sqmm continuous earth wire complete all as specified and directed Note: Two runs of 1.5 Sqmm cable with 01 run of 1.5 Sqmm earth wire along with casing caping/conduit shall be measured as one RM
M&L for sub main wiring with two single core PVC insulated FRLS cables with stranded copper conductors 2.5 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with conduit accessories and copper cable 2.5 sqmm continuous earth wire complete all as specified and directed Note: Two runs of 2.5 Sqmm cable with 01 run of 2.5 Sqmm earth wire along with casing caping/conduit shall be measured as one RM
M&L for sub main wiring with two single core PVC insulated FRLS cables with stranded copper conductors 4 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with conduit accessories and copper cable 4 sqmm continuous earth wire complete all as specified and directed Note: Two runs of 04 Sqmm cable with 01 run of 4 Sqmm earth wire along with casing caping/conduit shall be measured as one RM
M&L for sub main wiring with two single core PVC insulated FRLS cables with stranded copper conductors 6 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with accessories and copper cable 6 sqmm continuous earth wire complete all as specified and directed Note: Two runs of 06 Sqmm cable with 01 run of 6 Sqmm earth wire along with casing caping /conduit shall be measured as one RM
Taking down carefully sub main wiring of any type and size and making good disturbed surfaces complete as directed.
S&F 1100 volts grade heavy duty cable 4 Sqmm two core PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular including taking down of existing complete all as specified and directed.
S&F in replacement factory made epoxy powder coated Distribution Board TP&N 4 way double door (VTPN MCCB DB ) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishes complete all as specified and directed. Note: MCBs/ MCCBs will be measured and paid seperately under respective Sch A item in the schedule
S&F in replacement MCB DB 12 way SPN double door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar,surface mounting complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and making good distrubed surface and touch up with the same fineshes complete all as specified and directed. Note - MCBs will be measured & paid separately under respective item of sch A, if required to be replaced.
All as per item no 208 above but 08 way SPN DB (Double door)
All as per item no 208 above but 04 way SPN DB (Single door)
All as per item no 208 above but 04 way SPN DB (Double door)
All as per item no 208 above but 02 way SPN DB (Single door)
S&F in replacement distribution box 18 Module 230V, 5 HZ, IP-65 & IK-09 Class-II, weatherproof cabinets, door and cabinet fully reversible, removable chassis and faceplates, including weatherproof glands, rails qty-1 Nos, coppper fork type 100 A busbars as short link including end caps, qty-1 nos, MCB SPN 06 Amp 230V, 50 HZ, complete all as specified and directed Make: Legrand Catpart No.601835 or equivalent in make as mentioned at makes list in PS
S&F in replacement of MCCB with rating of 100 Amps,415Volts 3pole with 16kA breaking capacity,thermal magnetic asdjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu).MCCB should be with suitable spreaders and phase barriers for each terminals complete all as specified and directed
S&F in replacement of MCCB with rating of 63 Amps,415Volts 3pole with 16kA breaking capacity,thermal magnetic asdjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu).MCCB should be with suitable spreaders and phase barriers for each terminals complete all as specified and directed
S&F in replacement of C Curve MCB SP 6-32 Amps working on 240 volts,50 Hz 10 KA all as specified and directed.
S&F in replacement of C Curve MCB DP 6-32 Amps working on 240 volts,50 Hz 10 KA all as specified and directed.
S&F in replacement of C Curve MCB SPN 40-63 Amps working on 240 volts, 50 HZ,10 KA all as specified and directed.
S&F in replacement of C Curve MCB TP 63 Amps working on 240 volts, 50 HZ,10 KA all as specified and directed.
Supply and fix in replacement of C Curve MCB TPN 40-63 Amps working on 240 volts, 50 HZ,10 KA all as specified and directed.
Taking down ceiling fan/exhaust fan of any sweep for servicing / repairing / maintenance, opening up, identifying and replacing the defective parts, cleaning, greasing,etc, reassembling and hanging up/fixing back at its original position, connecting up and testing complete all as directed. Note : 1.Cost of spares such as capacitors, bearings etc will be measured and paid for separately under respective Item of sch A as supply only.
Supply only capacitor of 2.5 mfd for ceiling fan/exhaust fan. Make:Tibcon/Epcos
Supply only bearing No.6201/6202/6203 or any other No matching to the existing size and suitable for ceiling fan/exhaust fan/wall mounted fan. Make:SKF
S&F in replacment aluminum fan blades sutable for heavy duty exhaust fan of any sweep as per the sample given complete all as specified and directed.
Disconnecting electric connection and taking down carefully fan of any type and size/sweep as described below, removing the burnt winding of fan motor rewinding with super enarneled copper winding wire of suitable gauge or of matching size to the exisiting wires including all insulating material such as insulation paper sleeve, tape, varnishing etc and reassembling, testing, transporting back to site and reflxing to original position all as directed by Engineer-in-charge for following :- (a) Celling fan of size 1200 sweep.
All as per item no. 225 above but Exhaust fan of 300 mm sweep.
All as per item no. 225 above but wall mounted fan of 400 mm sweep.
M&L for painting the ceiling fan of any sweep with two coats of synthentic enamel paint by rubbing/removing the old paint carefully without any damage to the fan or fan blades complete all as specified and directed.
All as per item no. 228 above but exhaust fan of size 12" (300 mm) sweep
Dismantling and removing rusted louvers (set of 4) suitable for 300 mm sweep exhaust fan supply and fix MS louvers duly painted gray coloured suitable for 300mm heavy duty exhaust fan alongwith four number mounting bracket with bolts, nuts washers etc complete all as directed.
S&F in replacement of high speed wall mounted fan of sweep 400 mm, full copper motor, auto thermal overload protection,compact style and powder coated guards & pull cord switch for speed regulation and oscillation control including connectng up the power cord to the socket and necessary fixing accessories all as specified and directed.
S&F in replacement of Plastic ventilation fan with BLDC motor, energy efficient of 200/250 mm sweep inclduing replacing the plywood as per the site requirement. (Note: Old Exhuast fan should be deposited in MES store yard)
S&F in replacement of Metal body ventilation fan of 225 mm sweep inclduing replacing the plywood as per the site requirement complete all as specified and directed. (Note: Old Exhuast fan should be deposited in MES store yard) Make: Bajaj MAXX AIR/ Crompton Greaves Trans Air/ Havells VENTILAIR DB NEO or equivalent makes as mentioned at makes list in PS
S&F in replacement of Metal body ventilation fan of 300 mm sweep inclduing replacing the plywood as per the site requirement complete all as specified and directed (Note: Old Exhuast fan should be deposited in MES store yard) Make: Bajaj MAXX AIR/ Crompton Greaves Trans Air/ Havells VENTILAIR DB NEO or equivalent makes as mentioned at makes list in PS
S&F in replacement sheet metal enclosures Single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 volts complete with all accessaries etc complete all as specified and directed
S&F in replacement metal clad plug top 3 pin,10Amps, 230 volts, ISI marked heavy duty for geyser connection cord complete all as specified and directed.
S&F in replacement plug top 3 pin, 15/16 amps, 230 volts, ISI marked heavy duty for geyser connection cord complete all as specified and directed.
S&F in replacement plug top 3 pin, 5/6 amps, 230 volts, ISI marked complete all as specified and directed.
S&F in replacement 3mm thick white coloured hylam sheet (bakelite) for mounting switches complete all as specified and directed
S&F in replacement 1x10 watt,230V surface and wall mounted LED batten suitable for mirror light with polycarbonate housing and integrated electronic electronic driver including connecting up with twin core twisted flexible copper conductor cable from ceiling rose complete all as specified and directed.
S&F in replacement of 18/20watt,230V surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling rosecomplete all as specified and directed. Make- Luker LT5M20 / Havells ENDURALINEARNEOBS20WLED865SPCWH or equivalent makes as mentioned at makes list in PS
S&F in replacement of PVC unbreakable surface boxes of size 4"x4".complete all as specified and directed.
S&F in replacement of PVC unbreakable surface boxes of size 6"x6" complete all as specified and directed.
S& F in replacement of PVC unbreakable surface boxes of size 4"x7" complete all as specified and directed.
S& F in replacement of PVC unbreakable surface boxes of size 6"x8" complete all as specified and directed. .
S& F in replacement of PVC unbreakable surface boxes of size 8"x10" complete all as specified and directed.
S&F in replacement for white cover plate with frame 1 or 2 module. Make:As per the sample given
S&F in replacement for white cover plate with frame 3 module. Make:As per the sample given
S&F in replacement for white cover plate with frame 4 module.Make:As per the sample given
S&F in replacement for white cover plate with frame 6 module.Make:As per the sample given
S&F in replacement for white cover plate with frame 8 module.Make:As per the sample given
S&F in replacement for white cover plate with frame 12 module.Make:As per the sample given
S&F in replacement for white cover plate with frame 1 or 2 module complete all as specified and directed. . Make:As per the sample given
S&F in replacement for white cover plate with frame 3 module complete all as specified and directed. . Make:As per the sample given
S&F in replacement for white cover plate with frame 4 module complete all as specified and directed. .Make:As per the sample given
S&F in replacement for white cover plate with frame 6 module complete all as specified and directed. .Make:As per the sample given
S&F in replacement for white cover plate with frame 8 module complete all as specified and directed. .Make:As per the sample given
S&F in replacement for white cover plate with frame 12 modulecomplete all as specified and directed. .Make:As per the sample given
M/S AKASH ENTERPRISES
DARSHAN ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .