| 1 | L1₹28.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹29.9 L+₹1.8 L (6.22%)Rejected-Finance NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹30.9 L+₹2.8 L (9.76%)Rejected-Finance H O 20 D INDUSTRIAL ESTATE LEH LADAKH 194 101 J K | LEH | LEH | LADAKH | 194101 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹31.4 L+₹3.3 L (11.5%)Rejected-Finance 30 B 1 DEEN DAYAL NAGAR NAWABGANJ DEEN DAYAL NAGAR KANPUR NAGAR UTTAR PRADESH 208002 | KANPUR NAGAR | UTTAR PRADESH | 208002 | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹31.6 L+₹3.4 L (12.1%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
₹29.1 L
EMD Value
₹58,300
Closing Date
12 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE
GE 860 EWS
PROVN OF TOILET BLOCK WITH ALLIED INFRA AT KSP TANGTSE AND OTHER SANCTIONED WORKS AT TANGTSE AND DURBUK GRN UNDER GE 860 EWS
2021_MES_453921_1
8150/2021-22/E8
Open Tender
Civil Works
Item Rate
270 days
Tangtse
Class D category a i
9 documents required · 9 mandatory
₹500
Yes
GE 860 EWS
₹58,300
Yes
29 Sept 2021
23 Jun 2021
14 Aug 2021
23 Jun 2021
12 Aug 2021
5 Aug 2021
60 days
Amount
Excavation in trenches in any type of soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide and getting out including trimming of sides, for foundations, laying of cables & foundation of poles, stay assembly, complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 3.0 m depth for foundation of poles and getting out in any type of soil complete all as specified and directed by Engr-in-Charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed by Engr-in-Charge.
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to UG cable, complete all as specified and directed by Engr-in-Charge.
Material and labour for PCC 1:3:6 type C–2 (using 20 mm crushed graded stone aggregate/as in, coping to poles/ stay and necessary form work for rough finished surface complete all as specified and as directed.
Taking out old unserviceable/serviceable un-reinforced concrete PCC cable covers from excavated trench all as directed by the Engineer-in-Charge. Note:- Serviceable un-reinforced concrete PCC cable cover kept in safe custody for reuse at site and unserviceable un-reinforced concrete PCC cable cover through in low lying area complete all as directed by Engineer-in-Charge.
Laying only old reinforced PCC cable cover of any size as retrieved from serial item No- 07 here-in-before , complete all as directed by Engineer-in-Charge.
M&L for factory made un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for UG cable protection on the top of the sand cushioning, complete all as specified and directed by Engr-in-Charge.
S&F of galvanized iron pipe of 50 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall including painting with two coats of aluminium paint over a coat of red oxide paint, complete all as specified and directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate.
Supply and erection in vertical position steel tubular swaged pole type 410 SP-22 (8.5 metres long) with Mild Steel base plate of size 30cmx30cmx6 mm thick continuously welded to pole , final taper plug ,bolts ,nuts and screws all as specified including factory painted with two coats of black bituminious paint internally throughout and externally for embedded position and two coats of aluminium paint over a coat of red oxide primer over the ground and making 30cm wide strip (total 5 Nos ) with black and yellow paint including numbering complete all as specified .
Dismantling and taking down unserviceable street light fitting of any watt from LT poles and Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and LED alongwith fixing Clamps Nuts,Bolt etc on building, wall or pole complete all as specified and directed.
Dismantling and taking down Street light bracket, flat iron clamp, nuts bolts etc and supply and fix GI Street light bracket of size 32mm light grade of 1.5 metre length in new or old loction alingwith two numbers of clamp, nut bolt and washers of suitable size for fixing bracket all as directed at site.
M&L, in replacement, junction box outdoor type of size 17cmX22cm made out of MS sheet of thickness not less than 1.6 mm having hinged front opening door with two nos aluminium strip bus bar fitted on resin based insulator and including one No MCB SP 6 Amps rating and flat iron fixing clamp of size 25mmX3mm and complete painted with two coat of synthetic enamel aluminium paint over a coat of red oxide primer complete all as specified and as directed.Make Hensel/Syntex
Taking out old LT under ground cable from trenches / floor / road / wall / pipe / pole of any size and description incl joint, complete all as specified and directed by Engr-in-Charge.
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor (Stranded) 1100V grade cross-sectional area 16 Sqmm 4 core laid in trenches or passing through pipe or fixed on pole etc complete all as specified and directed by Engr-in-Charge.
Supply and fixing steel tube medium grade galvanized with all fitting and fixed complete to walls/ poles/ ceiling or laid in floor of size 40 mm bore for the protection of UG cables including dismantling/ taking out old, unserviceable one complete all as directed by Engineer-in-Charge.
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor (Stranded) 1100V grade cross-sectional area 10Sqmm 2core laid in trenches or passing through pipe or fixed on pole etc complete all as specified and directed by Engr-in-Charge.
Supply and fixing sheet Metal enclosure double shutter type for DB’s 240Volts Single Pole and Neutral 4 way with 200 Amps rated bus bar complete including wooden board of required size duly painted with matching colour paint complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing SPN 40 to 63 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single pole and neutral in the MCB DB complete with connection testing and commissioning.
Supply and fixing SP 5 to 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single pole and neutral in the MCB DB complete with connection testing and commissioning.
Excavation in post holes in hard/dense soil each n.exc 0.50 cum getting out, returing in and ramming earth or broken rubble mixed with earth around in layer not exc 25 cm watering and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and as directed by the Engr-in-Charge
M&L for cement concrete in foundation, filling and mass concrete type B1 1:2:4 (20 mm graded crushed stone aggregate) including necessary form work complete all as specified and as directed by the Engr-in-Charge
M&L for two coats of synthetic enamel paint over a coat of red oxide on new steel surfaces of any description, not otherwise described over 10 cm width or grith after preparation complete all as specified and as directed by the Engr-in-Charge
S&F MS pipes heavy grade with all fittings fixed to walls/coloumn complete all as specified and as directed by the Engr-in-Charge (Average dia 100 mm)
Material and labour for point wiring with 1.5 Sqmm copper conductor (Multi-standard) PVC insulated and unsheathed electric cable 1100 volts in and including PVC casing and capping of 25 mm and above (as per conductor run ) with all fittings/ accessories and including PVC insulated and unsheathed electric cable 1100 volts1.5 Sqmm ( multi-stranded) copper conductor single core( Green colour) cable as continuous earth wire connected to common earth dolly including 50 mm deep box made of 2nd class hard board of required size and shape etc covered with 3 mm thick plastic laminated sheet ( Make Hylum) for one light point independent controlled by one, one way switch complete all as specified and as directed by the Engineer-in-Charge.
All as per item Srl No 27 here in before, but for one 3 pin socket outlet 5 Amp on same board complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing switch piano flush button single pole one way 5 Amps complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing socket outlet multipurpose 2 pin and 3 pin, 5 Amp, flush type complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing angular lamp holder, metal cased body of brass with back plate suitable for 18 watt CFL/60 watt bulb for batten fittings, including Plastic square box of required size complete all as specified and directed by the Engineer-in-Charge.
S&F LED lamp 9/10/15W Complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing ceiling rose, surface bakelite, 65 x 50 mm, three terminals complete all specified and as directed by the Engineer-in-Charge.
Supply and fixing LED lights fitting 1x 20/22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
Supply and fixing sheet Metal enclosure double shutter type for DB’s 240 Volts Single Pole and Neutral 8 way with 200 Amps rated bus bar complete including wooden board of required size duly painted with matching colour paint acomplete all as specified and as directed by the Engr-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanized iron earth wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR 2009 Part-I and connecting to MCBDB’s earth test point all as specified or indicated including testing on completion .
Excavation over area n.exc n.exc 1.50m deep and getting out in any type of soil complete all specifiedand as directed by Engineer-in-Charge.
All as per item No.38 here in before but exc 1.50m and n.exc 3.00 mtr complete all specifiedand as directed by Engineer-in-Charge.
M & L for PCC 1:4:8 type D-2 ( Nominalmix) using 40 mm graded stone aggregate as in foundation filling , foundation of pole/stay and similar work complete all specifiedand as directed by Engineer-in-Charge.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete etc complete all specifiedand as directed by Engineer-in-Charge.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished square, rectangular or polygonal surfaces of concrete complete all specifiedand as directed by Engineer-in-Charge..
Formwork to sides of concrete roof beam, LBs sides and soffits (if any) of similar work; vertical or to batter for rough finished flat surfaces of concrete complete all specifiedand as directed by Engineer-in-Charge.
Formwork to soffits of suspedded slabs such as roof slabs, floor slabs landings and similar work ,vertical or to batter for rough finished flat surfaces of concrete complete all specifiedand as directed by Engineer-in-Charge.
M&L for rough finished formwork to edges of concrete flats, treads, break in floors, window cills, concrete railings, floor and roof n.exc 20 cm wide and side of RCC/ PCC band in walls, horizantal or sloping or similar work exc 10 cm but n. exc 20 cm wide complete all specifiedand as directed by Engineer-in-Charge.
M&L TMT bars 10mm dia and over in reinforcement cut to length bent to shape required incl hooking ends and binding with MS wire (annealed) not less than 0.9mm dia complete all as specifiedand as directed by Engineer-in-Charge.
M&L TMT bars 6 to 8mm dia and over in reinforcement cut to length bent to shape required incl hooking ends and binding with MS wire (annealed) not less than 0.9mm dia complete all specifiedand as directed by Engineer-in-Charge.
TMT bars for reinforcement 5mm to 10mm dia as in stirrups/spacers/binders etc. cut to length bent to shape required including bending cranking and hooking ends and binding with including MS wire not less than 0.9mm(annealed) dia complete all specifiedand as directed by Engineer-in-Charge.
M & L for providing RCC M- 25 in foundations, including rafts,footings, foundation beams, plinth beams, bases of columns and similar work complete all specifiedand as directed by Engineer-in-Charge.
M & L for providing RCC M- 25 in columns, pillars, piers, post and struts etc complete all specifiedand as directed by Engineer-in-Charge.
M & L for providing RCC M- 25 in Beams, cantilevers,and lintels and chajja etc complete all specifiedand as directed by Engineer-in-Charge.
M & L for providing RCC M- 25 in Slab supported in walls beams and columns in roof ,Landing, balconies, deck slabs and in shelves and similar work complete all specifiedand as directed by Engineer-in-Charge.
Walling of random rubble stone masonry, uncoursed, well bonded, bedded and solidly hearted, build in cement mortar 1:4 complete all specifiedand as directed by Engineer-in-Charge.
Walling of random rubble stone masonry, uncoursed, well bonded, bedded and solidly hearted, laid dry complete all specifiedand as directed by Engineer-in-Charge.
M & L Precast cement concrete block masonry type C1 1:3:6 (20mm graded aggregate) with solid blocks, exc. 10cm in width and, setting in cement mortar 1:6 complete all specifiedand as directed by Engineer-in-Charge.
M&L for Rendering 10mm thick in cement mortar 1:6 on PCC block walling or concrete surfaces, finished even and smooth without using extra cement complete all specifiedand as directed by Engineer-in-Charge.
M&L for Rendering 15mm thick, in cement mortar 1:4 on PCC block walling or concrete surfaces and finished even and fair without using extra cement complete all specifiedand as directed by Engineer-in-Charge.
M&L for Rendering 5mm thick in cement mortar 1:3 on ceiling surface, finished even and smooth without using extra cement complete all specifiedand as directed by Engineer-in-Charge.
S&F 2nd class soft wood plain, solid, straight chowkhats and frames, wrought,framed rebated on the solid , rounded or chamfered, put together with glue pinned at joints,complete all as specified and as directed by Engr-in-Charge.
M&L 30mm thick flush shutter,solid core construction,with block boand core and ply wood face panel,commercial type on both sides complete all specifiedand as directed by Engineer-in-Charge.
S&F 2nd class soft wood glazed/skeleton shutters 30mm thick for window , ventilators etc open rebated prepared to receive glass, gauze etc devided in squares with plain, chamfered or rounded, mitred and rebated sash bars any number with plain, chamfered or rounded, mitred and rebated beads for securing glass gauze etc complete all specifiedand as directed by Engineer-in-Charge.
S&F mild steel butt hinges medium weight cold rolled of size 100mm .shutters complete all specifiedand as directed by Engineer-in-Charge.
S&F Extruded Aluminium alloy handle fabricated type, anodised of size 125mm complete all specifiedand as directed by Engineer-in-Charge..
S&F Aluminium anodised barrel tower bolt of extruded section of size 200mm complete all specifiedand as directed by Engineer-in-Charge.
S&F Aluminium alloy, anodised sliding door bolt, with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded section and fixing bolts and sloding bolt of extruded section or cast alluminium alloy of size 250mm complete all specifiedand as directed by Engineer-in-Charge.
S&F mild steel butt hinges medium weight cold rolled of size 75mm complete all specifiedand as directed by Engineer-in-Charge..
S&F Aluminium anodised barrel tower bolt of extruded section of size 100mm complete all specifiedand as directed by Engineer-in-Charge.
S&F Extruded Aluminium alloy handle fabricated type, anodised of size 100mm fixed complete all specifiedand as directed by Engineer-in-Charge.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all specifiedand as directed by Engineer-in-Charge.
M& L for cement concrete 75mm thick type D - 2 using 40mm graded stone aggregate as in sub base to receive floor finish etc complete all specifiedand as directed by Engineer-in-Charge.
M& L for cement concrete 40mm thick type B - 1 using 20mm graded stone aggregate over sub base to receive floor finish etc complete all specifiedand as directed by Engineer-in-Charge.
S & F non skid ceramic coloured tiles 7 to 8mm thick (square or rectangular) area of each tiles exceeding 0.0.06sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match, over and including 15mm thick screed bed in cement mortar (1:6) complete all specifiedand as directed by Engineer-in-Charge.
S&F for Glazed ceramic coloured tiles in vertical surface 300x200x7mm thick , set and jointed in neat cement slurry and pointed in coloured cement to match tiles over and including 10mm thick backing coat in cement mortar 1:4 complete all specifiedand as directed by Engineer-in-Charge..
M&L for preparation of new plastered surface of walls and applying two coats of oil bound distember including preparity to plastered surface for distempering complete all specifiedand as directed by Engineer-in-Charge.
M&L for preparation of new plastered surface of ceiling and applying two coats of white washing and preparity to plastered surface ccomplete all specifiedand as directed by Engineer-in-Charge.
M&L for preparation of new plastered surface of walls and applying two coat of cement base paint on walls complete all specifiedand as directed by Engineer-in-Charge.
M&L for screed bed or bedding layers of mortars 15 mm thick with water proofing compound in cement mortar 1:4 laid over concrete surface when concrete is green at roof complete all specifiedand as directed by Engineer-in-Charge.
M&L for preparing new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all specifiedand as directed by Engineer-in-Charge.
Supply and fixing steel water tubing `medium grade’ galvanized 15 mm bore with all fittings and fixed complete to walls and joints fixed with adhesive complete all as specified & directed.
Supply and fixing steel water tubing `medium grade’ galvanized 20 mm bore with all fittings and fixed complete to walls and joints fixed with adhesive complete all as specified & directed.
S&F gun-metal stop cock 20 mm bore, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all specifiedand as directed by Engineer-in-Charge.
S&F stop valves 15mm bore cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all specifiedand as directed by Engineer-in-Charge.
S&F wash basin, Vitreous China white flat back of size 550x400mm including cutting for and pinning in ends of brackets or erecting stand but excluding taps, waste, chain and plugs and proclain stopper but including brackets complete all specifiedand as directed by Engineer-in-Charge.
S&F 32mm waste coupling of PTMT (half or full threaded) minium weight 45 gms and fixed complete all specifiedand as directed by Engineer-in-Charge.
S&F PVC connection 15mm size with PTMT nuts of length 450 fixed complete all as specified and directed.
S&F Vitreous china Urinal bowl, flat back,size of 465x355x265mm white minium with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securign urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement (excluding flushing cistern, flush pipe) and waste pipe with discharge arrangement complete all as specified fixed in repairs.
S&F urinal spreader of PTMT of any colour for fixing with 15mmdia pipe complete all as specified and directed.
S&F Viterous China water closet squatting pan, 'Orrisa' pattern, size 580 x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete including connectoin to trap, and to flushing pipe, anti syphonage pipe etc. including trap set in and including concrete and making good to floor complete all specifiedand as directed by Engineer-in-Charge..
Supply and fix PVC 10 Ltrs valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with flush pipe etc. ISI approved complete all specified and directed.
S&F brass chromium plated tubular towel rail 20mm dia 600 mm long, fixed complete all as specified and as directed.
S&F bib taps,15mm bore cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all specifiedand as directed by Engineer-in-Charge.
S&F 15mm bore pillar tap cast copper alloy chromium plated screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screw shanks screwed for iron pipe or union complete all specifiedand as directed by Engineer-in-Charge.
S&F rotational moulded polyethylene water storage tanks 500 ltr capacity (cylindrical vertical with closed top ) hoisted and fixed in position complete with ball valve of high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball and screwd for iron pipe 20mm bore ocomplete all specifiedand as directed by Engineer-in-Charge.
M&L for broken stone or boulder hard core of gauge not exc 63 mm deposited spread and levelled in layers not exc.15 cm thick watered and rammed to a true surfaces complete all specifiedand as directed by Engineer-in-Charge.
M&L for 75mm thick cement concrete 1:3:6 type C - 2, using 40mm graded stone aggregate as in plinth protection and finishing the surface even and smooth with using extra cement complete all specifiedand as directed by Engineer-in-Charge.
Supply and fixing 75mm bore SWR pipes single socketed in any length with rubber ring joints fixed to walls ,floors, trenches etc complete all specifiedand as directed by Engineer-in-Charge.
Supply and fixing PVC (SWR )bends (any radius) 75mm bore complete all specifiedand as directed by Engineer-in-Charge.
S&F 75mm dia outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all specifiedand as directed by Engineer-in-Charge.
S&F sheet glass shelf assembly consisting of 5.50mm thick sheet glass self 12cm wide with chromium plated brackets guard and railing 60 cm long complete all specifiedand as directed by Engineer-in-Charge.
S&F PVC (SWR) pipes 150 mm dia single socketed in any length with rubber rings joints, laid in trench, or in floors complete all specifiedand as directed by Engineer-in-Charge.
Plain cement concrete 1:3 :6 type C-2 (using 40 mm graded crushed stone aggregate) for bed to drain pipes including packing under and haunching against the sides of pipe for 150 mm bore after they are laid and tested complete all as specified and as directed.
M&L for Precast RCC 1:2:4 type B-1 (using 20 mm graded stone agg) as in manhole's cover slab etc placed in position including necessary form work and set in cement mortar 1:4 complete all specifiedand as directed by Engineer-in-Charge.
SINGH CONST CO
MS INFRATECH
M/S ASHISH AND CO
M/S VISION ENGINEERS
RAJ MOHD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .