Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 CrAccepted-AOC 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹11.8 Cr Quoted ₹12.8 Cr | L1 | Accepted-AOC Being Lowest Bidder |
| 2 | L2₹13.2 CrRejected-Finance 1630 SECTOR 7C CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | ₹13.2 Cr | L2 | Rejected-Finance Being other than lowest |
| 3 | L3₹13.2 CrRejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹13.2 Cr | L3 | Rejected-Finance Being other than lowest |
| 4 | L4₹13.4 CrRejected-Finance | ₹13.4 Cr | L4 | Rejected-Finance Being other than lowest |
| 5 | L5₹13.8 CrRejected-Finance 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹13.8 Cr | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹12 Cr
EMD Value
₹9.3 L
Closing Date
30 Dec 2022, 6:00 pmClosed
Chief Engineer, HQ CE Bareilly Zone
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly Cantt 243001
Augmentation and Improvement of Existing Electric Infra at Meerut
2022_MES_559251_1
CEBZ/MRT/T-14 OF 2022-23
Open Tender
Civil Works
365 days
Meerut
As per NIT
8 documents required · 8 mandatory
₹3,000
GE Utility EM Meerut
₹9.3 L
Yes
24 Feb 2023
21 Oct 2022
6 Jan 2023
21 Oct 2022
30 Dec 2022
22 Dec 2022
22 Oct 2022 - 7 Nov 2022
Amount
Supply, Installation, testing, and commissioning of 11KV Extensible Outdoor duty (IP 54 enclosure) SF6 gas insulated 4-way motor operated Ring Main Unit comprising of 3nos. 630 Amps Load Break Switches and 1No, 630 Amps Vacuum Circuit Breaker, cable termination from the front, breaking capacity 21KA/3sec (Internal Arc Classification ALF-R 21kA-1sec both for tank and cable box as per IEC 62271-200), enclosed in robotically welded stainless steel tank having IP67 Degree of Protection, leak rate of SF6 gas less than 0.1% and tested as per IEC 60056/60694/60298. The switchgear shall accommodate all the 4 modules in one tank. Protection CTs shall be ring core type, complete all as specified and directed. Make of RMU : SIEMENS (8DJH-ST)/ SCHNEIDER (FBX)/ Equivalent in ABB).
(A) NOTE:- Others details:- System Particulars:
(i) Nominal System Voltage : 11kV.
(ii) Voltage variation on supply side : ±10 %
(iii) Corresponding Highest System Voltage: 12kV.
(iv) Frequency : 50 Hz with ± 3 % tolerance
(v) Transient condition : -20 % or + 10 % combined variation of Voltage and frequency.
(vi) Number of Phase : 3 Phases.
(vii) Neutral earthling : Solidly earthed.
(viii) Fault level (minimum) kA /Sec : 21/3).
(ix) Lightning Impulse Withstand Voltage (kVp) : 75
(x) One minute dry/wet power frequency withstand voltage primary (kV rms) : 28KV
(xi) Rated Dynamic Withstand Current for 1 second duration (kAp) : 52.5KA
(B) Applicable Standards for this RMU scope of work
(i) The design, manufacture and performance of the Ring Main Units shall comply with all currently applicable statutes, regulations and safety codes.Nothing in this specification shall be construed to relieve the bidder off his responsibilities.
(ii) Unless otherwise specified, the Ring Main Units shall conform to the latest applicable, IEC 62271-100, IEC 62271-200.
(iii) All live parts, bus bars, shall preferably be enclosed in one tank to avoid multiple inter connections & sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank Grade SS304 of minimum 2.5 mm thickness.The RMU shall be type tested for internal arc test of 21KA/1 sec AFLR as per IEC62271-200. The outer enclosure shall cover the full length of the switch gear, to ensure IP54 protection for full door covering of complete switchgear. The protection relay shall be for 3 O/C + 1E/F (IDMT Type) Self powered numerical protection relay with low and high set of over current and earth fault , MODBUS communication along with RS 485 Port .
(iv) RMU and Vaccum Interruptor shall be as per OEM design. No additional plate/ accessories to be add to achieve Internal Arc of the Cable of 21kA-1sec, in the cable box chamber. RMUs should be manufactured, inspected and invoiced from the OEM factory only; no licensee partner manufactered RMU is acceptable.
(v) The SF6 gas filled 11 kV, 630 Amps, extensible type, Outdoor, SCADA compatible Motorized Ring Main Unit with Vacuum Circuit Breaker to be supplied against this specification shall be suitable for satisfactory continuous operation under the following tropical conditions, design ambient temperature (Degree C) 40 as per IEC.
(C) The unit shall include the following with all necessary standard fitting as required at site:
(i) Digital multimeter, Cl-1.0 complete set (Make : Elmeasure / conzerv /Rishabh)
(ii) Power bank suitable for RMU
(iii) Auxiliary relay for OTI, WTI, bucholz for out going transformer complete as per site requirment
(iv) Load Break Switch 12kV 630Amps 21kA-3sec with copper bus Bar and earth switch fitted with fixed type voltage indicator device and fault passes indicator (FPI) will be provided on each load break switch as per IEC.
(v) Vacuum Circuit Breaker 12kV 630Amps 21kA-3sec and fault making type Earthing Switch with micro-processor based selfpowered 3O/C + 1E/F relay fitted with fixed type voltage indicator device as per IEC 61958. Protection CTs suitable ratio 2.5VA burden (CT ratio shall be confirmed at time of drawing approval).-for all VCBs of RMUs
Note: Standard mano meter -01 for each tank, Operating handle - 01, cable clamping provision (standard)-01/for every cable entry suitable for 1RX3C cable upto 300Sqmm, Operation and maintenance manual - 01, RMU Foundation (Earth Work and PCC works) for placing RMU on plinth is deemed to be included in the cost quoted. Height of plinth should not be less than 0.5 mtrs from ground level.
All as per item No 1 above but RMU (Ring Main Unit) 4-way comprising of 02 Nos motorized operated load breaker switches and 02 Nos 630 Amps fixed type motorized spring charging VCB.
All as per item No 1 above but RMU (Ring Main Unit) 3-way comprising of 01 No motorized operated load breaker switches and 02 Nos 630 Amps fixed type motorized spring charging VCB.
All as per item No 1 above but RMU (Ring Main Unit) 3-way comprising of 02 Nos motorized operated load breaker switches and 01 No 630 Amps fixed type motorized spring charging VCB.
All as per item No 1 above but RMU (Ring Main Unit) 3-way comprising of 03 Nos motorized operated load breaker switches. (Note:- Except VCB and self power relay)
All as per item No 1 above but RMU (Ring Main Unit) 4-way comprising of 04 Nos motorized operated load breaker switches. (Note:- Except VCB and self power relay)
Supply and Laying, jointing testing and connecting XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, of size 95 Sqmm, 3 core, IS 7098 marked, suitable for HT 11 KV (E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed.
Supply and Laying, jointing testing and connecting XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, of size 185 sq mm, 3 core, IS 7098 marked, suitable for HT 11 KV (E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed.
Supply and Laying, jointing testing and connecting XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, of size 240 sq mm, 3 core, IS 7098 marked, suitable for HT 11 KV (E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed.
NOTE FOR ITEM No. 7 to 9:- Cable shall be procured from the manufacturer with CA No. mentioned on cable and drum.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil including trimming sides and bottom of trenches complete all as specified.
Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables complete all as specified & directed.
M&L Bricks for protection cover to under ground cable (with standard size fly ash bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm acomplete all as specified & directed.
Supplying and laying un-reinforced precast concrete cable covers class HV, Type-I, ISI marked flat, size 300mm x 180mm x 40mm complete all as specified & directed. Make- Mehtab Tiles Indoor/NTC Tiles Punchkula/Sukhi Enterprises Jamnagar
Taking down and relaying of the existing HT UG cable of any size in trenches / pipes / pole for re-routing the cable all as specified and directed . Note:- (i) Excavation, Removing, Returning filling, cable joint, sand, PCC cover shall be measured & paid under respective items.
Supply & fixing HT PCC 1:3:6 type C-1 cable route indicator of size 175mm x150mm and 750 mm long and upper front side each indicator shall be embracing 4mm deep with words "HT CABLE" and two coats of synthetic enamel brown along HT cable trench after every 30 Mtr and corner & on any turnning, road crossing etc including planting in ground complete all as specified and directed.
Auguring hole by using augering machine suitable for passing 40mm to 150 mm bore pipe in true horizontal position under road, PCC path etc., by means of mechanical ring/ auger after doing ultra sound to prevent any damage to existing cables/pipe line coming in the route, not exceeding 1.5 m in depth below existing surface level of road and not exceeding 30M in length complete all as specified. Note: (i) Pipes shall be measured and paid separately under respective items. (ii) Any damage to existing cables of any type shall be made good within 6 hours by the contractor without any extra cost to department (iii) It is contractor responsibility to liase with civil authorities for necessary permission required for civil road crossing and during laying of cable in Civil Area.
M&L for 100 mm nominal bore GI pipe / tubing, light grade for protection of earth lead / passing cable complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washers complete all as specified (Excavation & Earth work, shall be measured and paid separately) Note:- Jindal/Tata/Swastik
M&L for 150 mm nominal bore GI pipe /tubing, light grade for protection of earth lead / passing cable complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washers complete all as specified (Excavation & Earth work, shall be measured and paid separately) Note:- Jindal/Tata/Swastik
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, complete all as specified and directed. Make- 3M (M-Seal)/Cab Seal/Raychem
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm, complete all as specified and directed. Make- 3M(M-Seal)/Cab Seal/Raychem
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm, complete all as specified and directed. Make- 3M(M-Seal)/Cab Seal/Raychem
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, complete all as specified and directed. Make- 3M(M-Seal)/Cab Seal/Raychem
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm, complete all as specified and directed. Make- 3M(M-Seal)/Cab Seal/Raychem
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm, complete all as specified and directed. Make- 3M(M-Seal)/Cab Seal/Raychem
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for Straight through termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, complete all as specified and directed. Make- 3M(M-Seal)/Cab Seal/Raychem
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for Straight through termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm, complete all as specified and directed. Make- 3M(M-Seal)/Cab Seal/Raychem
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for Straight through termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 400 sqmm, complete all as specified and directed. Make- 3M(M-Seal)/Cab Seal/Raychem
Supply, laying, jointing, testing and commissioning LT underground cables, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-7098 (marked, laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe Complete all as specified and directed of the following sizes:- (NOTE :- Cable shall be procured from the manufacturer with CA No. mentioned on cable and drum)
(a) 120 Sqmm 3.5 core
(b) 150 Sqmm 3.5 core
(c) 185 Sqmm 3.5 core
(d) 240 Sqmm 3.5 core
(e) 300 Sqmm 3.5 core
(f) 400 Sqmm 3.5 core
M&L for plate earthing for sub station equipments (Transformer, lightning arrestor and feeder pillar box, RMUs) complete with galvanised mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of HT/LT equipments etc at the other, earth strip encased in and including 50mm bore GI grade pipe with all fittings from top of electrode to body of equipment fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregate and RCC cover complete all specified and shown in electrical plate No 5 of SSR Pt-I. The scope of work also includes necessary excavation and earthwork.Complete all as specified and directed.
M&L for Installation and testing of LT factory made outdoor cubical type panel board (manufactured from CPRI approved firm), overall dimension not less than 1.0m (L) X 0.5m (W) X 1.2m (H) fabricated with 3.15 mm thick CRCA sheet on mild steel angle iron 50x50x6mm frame, totally enclosed type dust & vermin proof double door, back and front side openable fixed with nut & bolts with hinged shutter and locking arrangement for individual MCCBs, powder coated finished both internally and externally, suitable for 3 phase 4 wire system 415 volts grade, having aluminum busbar chamber of 400 Amps wrapped with PVC sleeves with colour code and provision of making holes, cable connections with copper nut, bolts & washers including hydrograpic insulators with nuts & bolts at both ends including complete internal wiring with 10 sqmm PVC insulated copper wire (FRLS) and provision of PCC 1:3:6 type C-2 foundation platform of suitable size (30 cm above ground level), with provision for fixing MCCBs necessary inter connections with alluminium strips of size 25 x 5mm duly wrapped with coloured insulating tape/sleeves and providing under mentioned equipments & accessories including connections of all out going/in coming existing/new cables of size 35 Sqmm to 400 Sqmm by drawing /digging out cable from loops in trenches out side the Bldgs inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, and taking out of old skelton type panel with control switches/all accessories complete, complete all as specified and as directed. (NOTE:-LT Panel board shall be as per IS/IEC 61439-Part I & II, Test certificates Panel Builder/ with QMS and EMS certfications like ISO9001, ISO14001& ISO45001 will be submitted before executing the job)
(a) Digital VAF + PF Meters with RS 485, Cl 1 of voltage measurement range 50-520 VAC, including CT/PT site programable, flush mounting 96 x 96 mm - 01 No (b) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
INCOMING MCCB 4 Pole, Microprocessor Based 250A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (Make of MCCBs:- Legrand/Siemens/Schneider/ABB) OUTGOING MCCB 4 Pole, Microprocessor Based 125A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -02 Nos along with Spreader terminals and Rotary handle. (Make of MCCBs:- Legrand/Siemens/Schneider/ABB)
M&L for Installation and testing of LT factory made outdoor cubical type panel board (manufactured from CPRI approved firm), overall dimension not less than 1.0m (L) X 0.5m (W) X 1.2m (H) fabricated with 3.15 mm thick CRCA sheet on mild steel angle iron 50x50x6mm frame, totally enclosed type dust & vermin proof double door, back and front side openable fixed with nut & bolts with hinged shutter and locking arrangement for individual MCCBs, powder coated finished both internally and externally, suitable for 3 phase 4 wire system 415 volts grade, having aluminum busbar chamber of 500 Amps wrapped with PVC sleeves with colour code and provision of making holes, cable connections with copper nut, bolts & washers including hydrograpic insulators with nuts & bolts at both ends including complete internal wiring with 10 sqmm PVC insulated copper wire (FRLS) and provision of PCC 1:3:6 type C-2 foundation platform of suitable size (30 cm above ground level), with provision for fixing MCCBs necessary inter connections with alluminium strips of size 25 x 5mm duly wrapped with coloured insulating tape/sleeves and providing under mentioned equipments & accessories including connections of all out going/in coming existing/new cables of size 35 Sqmm to 400 Sqmm by drawing /digging out cable from loops in trenches out side the Bldgs inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, and taking out of old skelton type panel with control switches/all accessories complete, complete all as specified and as directed. (NOTE:-LT Panel board shall be as per IS/IEC 61439-Part I & II, Test certificates Panel Builder/ with QMS and EMS certfications like ISO9001, ISO14001& ISO45001 will be submitted before executing the job)
(a) Digital VAF + PF Meters with RS 485, Cl 1 of voltage measurement range 50-520 VAC, including CT/PT site programable, flush mounting 96 x 96 mm - 01 No (b) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
INCOMING: MCCB 4 Pole, Microprocessor Based 315 A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle all as directed. OUTGOING: MCCB 4 Pole, Microprocessor Based 160A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -02 Nos along with Spreader terminals and Rotary handle. (Make of MCCBs:- Legrand/Siemens/Schneider/ABB)
M&L for Installation and testing of LT factory made outdoor cubical type panel board (manufactured from CPRI approved firm), overall dimension not less than 1.0m (L) X 0.5m (W) X 1.2m (H) fabricated with 3.15 mm thick CRCA sheet on mild steel angle iron 50x50x6mm frame, totally enclosed type dust & vermin proof double door, back and front side openable fixed with nut & bolts with hinged shutter and locking arrangement for individual MCCBs, powder coated finished both internally and externally, suitable for 3 phase 4 wire system 415 volts grade, having aluminum busbar chamber of 500 Amps wrapped with PVC sleeves with colour code and provision of making holes, cable connections with copper nut, bolts & washers including hydrograpic insulators with nuts & bolts at both ends including complete internal wiring with 10 sqmm PVC insulated copper wire (FRLS) and provision of PCC 1:3:6 type C-2 foundation platform of suitable size (30 cm above ground level), with provision for fixing MCCBs necessary inter connections with alluminium strips of size 25 x 5mm duly wrapped with coloured insulating tape/sleeves and providing under mentioned equipments & accessories including connections of all out going/in coming existing/new cables of size 35 Sqmm to 400 Sqmm by drawing /digging out cable from loops in trenches out side the Bldgs inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, and taking out of old skelton type panel with control switches/all accessories complete, complete all as specified and as directed. (NOTE:-LT Panel board shall be as per IS/IEC 61439-Part I & II, Test certificates Panel Builder/ with QMS and EMS certfications like ISO9001, ISO14001& ISO45001 will be submitted before executing the job)
(a) Digital VAF + PF Meters with RS 485, Cl 1 of voltage measurement range 50-520 VAC, including CT/PT site programable, flush mounting 96 x 96 mm - 01 No (b) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
INCOMING: MCCB 4 Pole, Microprocessor Based 315 A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle all as directed. OUTGOING: (a) MCCB 4 Pole, Microprocessor Based 200A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (b) MCCB 4 Pole, Microprocessor Based 100A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (Make of MCCBs:- Legrand/Siemens/Schneider/ABB)
M&L for Installation and testing of LT factory made outdoor cubical type panel board (manufactured from CPRI approved firm), overall dimension not less than 1.0m (L) X 0.5m (W) X 1.2m (H) fabricated with 3.15 mm thick CRCA sheet on mild steel angle iron 50x50x6mm frame, totally enclosed type dust & vermin proof double door, back and front side openable fixed with nut & bolts with hinged shutter and locking arrangement for individual MCCBs, powder coated finished both internally and externally, suitable for 3 phase 4 wire system 415 volts grade, having aluminum busbar chamber of 600 Amps wrapped with PVC sleeves with colour code and provision of making holes, cable connections with copper nut, bolts & washers including hydrograpic insulators with nuts & bolts at both ends including complete internal wiring with 10 sqmm PVC insulated copper wire (FRLS) and provision of PCC 1:3:6 type C-2 foundation platform of suitable size (30 cm above ground level), with provision for fixing MCCBs necessary inter connections with alluminium strips of size 25 x 5mm duly wrapped with coloured insulating tape/sleeves and providing under mentioned equipments & accessories including connections of all out going/in coming existing/new cables of size 35 Sqmm to 400 Sqmm by drawing /digging out cable from loops in trenches out side the Bldgs inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, and taking out of old skelton type panel with control switches/all accessories complete, complete all as specified and as directed. (NOTE:-LT Panel board shall be as per IS/IEC 61439-Part I & II, Test certificates Panel Builder/ with QMS and EMS certfications like ISO9001, ISO14001& ISO45001 will be submitted before executing the job)
(a) Digital VAF + PF Meters with RS 485, Cl 1 of voltage measurement range 50-520 VAC, including CT/PT site programable, flush mounting 96 x 96 mm - 01 No (b) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
INCOMING: MCCB 4 Pole, Microprocessor Based 400 A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle all as directed. OUTGOING: (a) MCCB 4 Pole, Microprocessor Based 200A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (b) MCCB 4 Pole, Microprocessor Based 160A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC, protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (Make of MCCBs:- Legrand/Siemens/Schneider/ABB)
M&L for Installation and testing of LT factory made outdoor cubical type panel board (manufactured from CPRI approved firm), overall dimension not less than 1.0m (L) X 0.5m (W) X 1.2m (H) fabricated with 3.15 mm thick CRCA sheet on mild steel angle iron 50x50x6mm frame, totally enclosed type dust & vermin proof double door, back and front side openable fixed with nut & bolts with hinged shutter and locking arrangement for individual MCCBs, powder coated finished both internally and externally, suitable for 3 phase 4 wire system 415 volts grade, having aluminum busbar chamber of 600 Amps wrapped with PVC sleeves with colour code and provision of making holes, cable connections with copper nut, bolts & washers including hydrograpic insulators with nuts & bolts at both ends including complete internal wiring with 10 sqmm PVC insulated copper wire (FRLS) and provision of PCC 1:3:6 type C-2 foundation platform of suitable size (30 cm above ground level), with provision for fixing MCCBs necessary inter connections with alluminium strips of size 25 x 5mm duly wrapped with coloured insulating tape/sleeves and providing under mentioned equipments & accessories including connections of all out going/in coming existing/new cables of size 35 Sqmm to 400 Sqmm by drawing /digging out cable from loops in trenches out side the Bldgs inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, and taking out of old skelton type panel with control switches/all accessories complete, complete all as specified and as directed. (NOTE:-LT Panel board shall be as per IS/IEC 61439-Part I & II, Test certificates Panel Builder/ with QMS and EMS certfications like ISO9001, ISO14001& ISO45001 will be submitted before executing the job)
(a) Digital VAF + PF Meters with RS 485, Cl 1 of voltage measurement range 50-520 VAC, including CT/PT site programable, flush mounting 96 x 96 mm - 01 No (b) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
INCOMING: MCCB 4 Pole, Microprocessor Based 400 A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle all as directed. OUTGOING: (a) MCCB 4 Pole, Microprocessor Based 160A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (b) MCCB 4 Pole, Microprocessor Based 125A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity -02 Nos along with Spreader terminals and Rotary handle. (Make of MCCBs:- Legrand/Siemens/Schneider/ABB)
M&L for Installation and testing of LT factory made outdoor cubical type panel board (manufactured from CPRI approved firm), overall dimension not less than 1.0m (L) X 0.5m (W) X 1.2m (H) fabricated with 3.15 mm thick CRCA sheet on mild steel angle iron 50x50x6mm frame, totally enclosed type dust & vermin proof double door, back and front side openable fixed with nut & bolts with hinged shutter and locking arrangement for individual MCCBs, powder coated finished both internally and externally, suitable for 3 phase 4 wire system 415 volts grade, having aluminum busbar chamber of 750 Amps wrapped with PVC sleeves with colour code and provision of making holes, cable connections with copper nut, bolts & washers including hydrograpic insulators with nuts & bolts at both ends including complete internal wiring with 10 sqmm PVC insulated copper wire (FRLS) and provision of PCC 1:3:6 type C-2 foundation platform of suitable size (30 cm above ground level), with provision for fixing MCCBs necessary inter connections with alluminium strips of size 25 x 5mm duly wrapped with coloured insulating tape/sleeves and providing under mentioned equipments & accessories including connections of all out going/in coming existing/new cables of size 35 Sqmm to 400 Sqmm by drawing /digging out cable from loops in trenches out side the Bldgs inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, and taking out of old skelton type panel with control switches/all accessories complete, complete all as specified and as directed. (NOTE:-LT Panel board shall be as per IS/IEC 61439-Part I & II, Test certificates Panel Builder/ with QMS and EMS certfications like ISO9001, ISO14001& ISO45001 will be submitted before executing the job)
(a) Digital VAF + PF Meters with RS 485, Cl 1 of voltage measurement range 50-520 VAC, including CT/PT site programable, flush mounting 96 x 96 mm - 01 No (b) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
INCOMING: MCCB 4 Pole, Microprocessor Based 500 A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle all as directed. OUTGOING : (a) MCCB 4 Pole, Microprocessor Based 315A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (b) MCCB 4 Pole, Microprocessor Based 160A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (Make of MCCBs:- Legrand/Siemens/Schneider/ABB)
M&L for Installation and testing of LT factory made outdoor cubical type panel board (manufactured from CPRI approved firm), overall dimension not less than 1.0m (L) X 0.5m (W) X 1.2m (H) fabricated with 3.15 mm thick CRCA sheet on mild steel angle iron 50x50x6mm frame, totally enclosed type dust & vermin proof double door, back and front side openable fixed with nut & bolts with hinged shutter and locking arrangement for individual MCCBs, powder coated finished both internally and externally, suitable for 3 phase 4 wire system 415 volts grade, having aluminum busbar chamber of 750 Amps wrapped with PVC sleeves with colour code and provision of making holes, cable connections with copper nut, bolts & washers including hydrograpic insulators with nuts & bolts at both ends including complete internal wiring with 10 sqmm PVC insulated copper wire (FRLS) and provision of PCC 1:3:6 type C-2 foundation platform of suitable size (30 cm above ground level), with provision for fixing MCCBs necessary inter connections with alluminium strips of size 25 x 5mm duly wrapped with coloured insulating tape/sleeves and providing under mentioned equipments & accessories including connections of all out going/in coming existing/new cables of size 35 Sqmm to 400 Sqmm by drawing /digging out cable from loops in trenches out side the Bldgs inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, and taking out of old skelton type panel with control switches/all accessories complete, complete all as specified and as directed. (NOTE:-LT Panel board shall be as per IS/IEC 61439-Part I & II, Test certificates Panel Builder/ with QMS and EMS certfications like ISO9001, ISO14001& ISO45001 will be submitted before executing the job)
(a) Digital VAF + PF Meters with RS 485, Cl 1 of voltage measurement range 50-520 VAC, including CT/PT site programable, flush mounting 96 x 96 mm - 01 No (b) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
INCOMING: MCCB 4 Pole, Microprocessor Based 500 A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle all as directed. OUTGOING (a) MCCB 4 Pole, Microprocessor Based 250A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (b) MCCB 4 Pole, Microprocessor Based 200A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (Make of MCCBs:- Legrand/Siemens/Schneider/ABB)
M&L for Installation and testing of LT factory made outdoor cubical type panel board (manufactured from CPRI approved firm), overall dimension not less than 1.0m (L) X 0.5m (W) X 1.2m (H) fabricated with 3.15 mm thick CRCA sheet on mild steel angle iron 50x50x6mm frame, totally enclosed type dust & vermin proof double door, back and front side openable fixed with nut & bolts with hinged shutter and locking arrangement for individual MCCBs, powder coated finished both internally and externally, suitable for 3 phase 4 wire system 415 volts grade, having aluminum busbar chamber of 1000 Amps wrapped with PVC sleeves with colour code and provision of making holes, cable connections with copper nut, bolts & washers including hydrograpic insulators with nuts & bolts at both ends including complete internal wiring with 10 sqmm PVC insulated copper wire (FRLS) and provision of PCC 1:3:6 type C-2 foundation platform of suitable size (30 cm above ground level), with provision for fixing MCCBs necessary inter connections with alluminium strips of size 25 x 5mm duly wrapped with coloured insulating tape/sleeves and providing under mentioned equipments & accessories including connections of all out going/in coming existing/new cables of size 35 Sqmm to 400 Sqmm by drawing /digging out cable from loops in trenches out side the Bldgs inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, and taking out of old skelton type panel with control switches/all accessories complete, complete all as specified and as directed. (NOTE:-LT Panel board shall be as per IS/IEC 61439-Part I & II, Test certificates Panel Builder/ with QMS and EMS certfications like ISO9001, ISO14001& ISO45001 will be submitted before executing the job)
(a) Digital VAF + PF Meters with RS 485, Cl 1 of voltage measurement range 50-520 VAC, including CT/PT site programable, flush mounting 96 x 96 mm - 01 No (b) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
INCOMING: MCCB 4 Pole, Microprocessor Based 630 A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle all as directed. OUTGOING : (a) MCCB 4 Pole, Microprocessor Based 400A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (b) MCCB 4 Pole, Microprocessor Based 125A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (Make of MCCBs:- Legrand/Siemens/Schneider/ABB)
M&L for Installation and testing of LT factory made outdoor cubical type panel board (manufactured from CPRI approved firm), overall dimension not less than 1.0m (L) X 0.5m (W) X 1.2m (H) fabricated with 3.15 mm thick CRCA sheet on mild steel angle iron 50x50x6mm frame, totally enclosed type dust & vermin proof double door, back and front side openable fixed with nut & bolts with hinged shutter and locking arrangement for individual MCCBs, powder coated finished both internally and externally, suitable for 3 phase 4 wire system 415 volts grade, having aluminum busbar chamber of 1000 Amps wrapped with PVC sleeves with colour code and provision of making holes, cable connections with copper nut, bolts & washers including hydrograpic insulators with nuts & bolts at both ends including complete internal wiring with 10 sqmm PVC insulated copper wire (FRLS) and provision of PCC 1:3:6 type C-2 foundation platform of suitable size (30 cm above ground level), with provision for fixing MCCBs necessary inter connections with alluminium strips of size 25 x 5mm duly wrapped with coloured insulating tape/sleeves and providing under mentioned equipments & accessories including connections of all out going/in coming existing/new cables of size 35 Sqmm to 400 Sqmm by drawing /digging out cable from loops in trenches out side the Bldgs inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, and taking out of old skelton type panel with control switches/all accessories complete, complete all as specified and as directed. (NOTE:-LT Panel board shall be as per IS/IEC 61439-Part I & II, Test certificates Panel Builder/ with QMS and EMS certfications like ISO9001, ISO14001& ISO45001 will be submitted before executing the job)
(a) Digital VAF + PF Meters with RS 485, Cl 1 of voltage measurement range 50-520 VAC, including CT/PT site programable, flush mounting 96 x 96 mm - 01 No (b) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
INCOMING: MCCB 4 Pole, Microprocessor Based 630 A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle all as directed. OUTGOING : (a) MCCB 4 Pole, Microprocessor Based 250A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -02 Nos along with Spreader terminals and Rotary handle. (b) MCCB 4 Pole, Microprocessor Based 200A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (Make of MCCBs:- Legrand/Siemens/Schneider/ABB)
M&L for Installation and testing of LT factory made outdoor cubical type panel board (manufactured from CPRI approved firm), overall dimension not less than 1.0m (L) X 0.5m (W) X 1.2m (H) fabricated with 3.15 mm thick CRCA sheet on mild steel angle iron 50x50x6mm frame, totally enclosed type dust & vermin proof double door, back and front side openable fixed with nut & bolts with hinged shutter and locking arrangement for individual MCCBs, powder coated finished both internally and externally, suitable for 3 phase 4 wire system 415 volts grade, having aluminum busbar chamber of 1000 Amps wrapped with PVC sleeves with colour code and provision of making holes, cable connections with copper nut, bolts & washers including hydrograpic insulators with nuts & bolts at both ends including complete internal wiring with 10 sqmm PVC insulated copper wire (FRLS) and provision of PCC 1:3:6 type C-2 foundation platform of suitable size (30 cm above ground level), with provision for fixing MCCBs necessary inter connections with alluminium strips of size 25 x 5mm duly wrapped with coloured insulating tape/sleeves and providing under mentioned equipments & accessories including connections of all out going/in coming existing/new cables of size 35 Sqmm to 400 Sqmm by drawing /digging out cable from loops in trenches out side the Bldgs inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, and taking out of old skelton type panel with control switches/all accessories complete, complete all as specified and as directed. (NOTE:-LT Panel board shall be as per IS/IEC 61439-Part I & II, Test certificates Panel Builder/ with QMS and EMS certfications like ISO9001, ISO14001& ISO45001 will be submitted before executing the job)
(a) Digital VAF + PF Meters with RS 485, Cl 1 of voltage measurement range 50-520 VAC, including CT/PT site programable, flush mounting 96 x 96 mm - 01 No (b) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
INCOMING: MCCB 4 Pole, Microprocessor Based 630 A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle all as directed. OUTGOING (a) MCCB 4 Pole, Microprocessor Based 315A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (b) MCCB 4 Pole, Microprocessor Based 125A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -02 Nos along with Spreader terminals and Rotary handle. (Make of MCCBs:- Legrand/Siemens/Schneider/ABB)
M&L for Installation and testing of LT factory made outdoor cubical type panel board (manufactured from CPRI approved firm), overall dimension not less than 1.0m (L) X 0.5m (W) X 1.2m (H) fabricated with 3.15 mm thick CRCA sheet on mild steel angle iron 50x50x6mm frame, totally enclosed type dust & vermin proof double door, back and front side openable fixed with nut & bolts with hinged shutter and locking arrangement for individual MCCBs, powder coated finished both internally and externally, suitable for 3 phase 4 wire system 415 volts grade, having aluminum busbar chamber of 1000 Amps wrapped with PVC sleeves with colour code and provision of making holes, cable connections with copper nut, bolts & washers including hydrograpic insulators with nuts & bolts at both ends including complete internal wiring with 10 sqmm PVC insulated copper wire (FRLS) and provision of PCC 1:3:6 type C-2 foundation platform of suitable size (30 cm above ground level), with provision for fixing MCCBs necessary inter connections with alluminium strips of size 25 x 5mm duly wrapped with coloured insulating tape/sleeves and providing under mentioned equipments & accessories including connections of all out going/in coming existing/new cables of size 35 Sqmm to 400 Sqmm by drawing /digging out cable from loops in trenches out side the Bldgs inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, and taking out of old skelton type panel with control switches/all accessories complete, complete all as specified and as directed. (NOTE:-LT Panel board shall be as per IS/IEC 61439-Part I & II, Test certificates Panel Builder/ with QMS and EMS certfications like ISO9001, ISO14001& ISO45001 will be submitted before executing the job)
(a) Digital VAF + PF Meters with RS 485, Cl 1 of voltage measurement range 50-520 VAC, including CT/PT site programable, flush mounting 96 x 96 mm - 01 No (b) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
INCOMING: MCCB 4 Pole, Microprocessor Based 630 A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle all as directed. OUTGOING : (a) MCCB 4 Pole, Microprocessor Based 315A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (b) MCCB 4 Pole, Microprocessor Based 250A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -02 Nos along with Spreader terminals and Rotary handle. (Make of MCCBs:- Legrand/Siemens/Schneider/ABB)
M&L for Installation and testing of LT factory made outdoor cubical type panel board (manufactured from CPRI approved firm), overall dimension not less than 1.0m (L) X 0.5m (W) X 1.2m (H) fabricated with 3.15 mm thick CRCA sheet on mild steel angle iron 50x50x6mm frame, totally enclosed type dust & vermin proof double door, back and front side openable fixed with nut & bolts with hinged shutter and locking arrangement for individual MCCBs, powder coated finished both internally and externally, suitable for 3 phase 4 wire system 415 volts grade, having aluminum busbar chamber of 1200 Amps wrapped with PVC sleeves with colour code and provision of making holes, cable connections with copper nut, bolts & washers including hydrograpic insulators with nuts & bolts at both ends including complete internal wiring with 10 sqmm PVC insulated copper wire (FRLS) and provision of PCC 1:3:6 type C-2 foundation platform of suitable size (30 cm above ground level), with provision for fixing MCCBs necessary inter connections with alluminium strips of size 25 x 5mm duly wrapped with coloured insulating tape/sleeves and providing under mentioned equipments & accessories including connections of all out going/in coming existing/new cables of size 35 Sqmm to 400 Sqmm by drawing /digging out cable from loops in trenches out side the Bldgs inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, and taking out of old skelton type panel with control switches/all accessories complete, complete all as specified and as directed. (NOTE:-LT Panel board shall be as per IS/IEC 61439-Part I & II, Test certificates Panel Builder/ with QMS and EMS certfications like ISO9001, ISO14001& ISO45001 will be submitted before executing the job)
(a) Digital VAF + PF Meters with RS 485, Cl 1 of voltage measurement range 50-520 VAC, including CT/PT site programable, flush mounting 96 x 96 mm - 01 No (b) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
INCOMING: Air Circuit Breaker (ACB) 4 Pole draw out type 800 Amps, Breaking capacity 50 KA, LED display, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle all as directed. OUTGOING: (a) MCCB 4 Pole, Microprocessor Based 315A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (b) MCCB 4 Pole, Microprocessor Based 250A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version), Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (Make of MCCBs:- Legrand/Siemens/Schneider/ABB) (c) MCCB 4 Pole, Microprocessor Based 160A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC, protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version), Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (Make of MCCBs/ACBs:- Legrand/Siemens /Schneider/ABB/L&T)
M&L for Installation and testing of LT factory made outdoor cubical type panel board (manufactured from CPRI approved firm), overall dimension not less than 1.0m (L) X 0.5m (W) X 1.2m (H) fabricated with 3.15 mm thick CRCA sheet on mild steel angle iron 50x50x6mm frame, totally enclosed type dust & vermin proof double door, back and front side openable fixed with nut & bolts with hinged shutter and locking arrangement for individual MCCBs, powder coated finished both internally and externally, suitable for 3 phase 4 wire system 415 volts grade, having aluminum busbar chamber of 1200 Amps wrapped with PVC sleeves with colour code and provision of making holes, cable connections with copper nut, bolts & washers including hydrograpic insulators with nuts & bolts at both ends including complete internal wiring with 10 sqmm PVC insulated copper wire (FRLS) and provision of PCC 1:3:6 type C-2 foundation platform of suitable size (30 cm above ground level), with provision for fixing MCCBs necessary inter connections with alluminium strips of size 25 x 5mm duly wrapped with coloured insulating tape/sleeves and providing under mentioned equipments & accessories including connections of all out going/in coming existing/new cables of size 35 Sqmm to 400 Sqmm by drawing /digging out cable from loops in trenches out side the Bldgs inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, and taking out of old skelton type panel with control switches/all accessories complete, complete all as specified and as directed. (NOTE:-LT Panel board shall be as per IS/IEC 61439-Part I & II, Test certificates Panel Builder/ with QMS and EMS certfications like ISO9001, ISO14001& ISO45001 will be submitted before executing the job)
(a) Digital VAF + PF Meters with RS 485, Cl 1 of voltage measurement range 50-520 VAC, including CT/PT site programable, flush mounting 96 x 96 mm - 01 No (b) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
INCOMING: Air Circuit Breaker (ACB) 4 Pole draw out type 800 Amps, Breaking capacity 50 KA, LED display, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle all as directed. OUTGOING : (a) MCCB 4 Pole, Microprocessor Based 400A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (b) MCCB 4 Pole, Microprocessor Based 315A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (Make of MCCBs/ACBs:- Legrand/Siemens /Schneider/ABB/L&T)
M&L for Installation and testing of LT factory made outdoor cubical type panel board (manufactured from CPRI approved firm), overall dimension not less than 1.0m (L) X 0.5m (W) X 1.2m (H) fabricated with 3.15 mm thick CRCA sheet on mild steel angle iron 50x50x6mm frame, totally enclosed type dust & vermin proof double door, back and front side openable fixed with nut & bolts with hinged shutter and locking arrangement for individual MCCBs, powder coated finished both internally and externally, suitable for 3 phase 4 wire system 415 volts grade, having aluminum busbar chamber of 1200 Amps wrapped with PVC sleeves with colour code and provision of making holes, cable connections with copper nut, bolts & washers including hydrograpic insulators with nuts & bolts at both ends including complete internal wiring with 10 sqmm PVC insulated copper wire (FRLS) and provision of PCC 1:3:6 type C-2 foundation platform of suitable size (30 cm above ground level), with provision for fixing MCCBs necessary inter connections with alluminium strips of size 25 x 5mm duly wrapped with coloured insulating tape/sleeves and providing under mentioned equipments & accessories including connections of all out going/in coming existing/new cables of size 35 Sqmm to 400 Sqmm by drawing /digging out cable from loops in trenches out side the Bldgs inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, and taking out of old skelton type panel with control switches/all accessories complete, complete all as specified and as directed. (NOTE:-LT Panel board shall be as per IS/IEC 61439-Part I & II, Test certificates Panel Builder/ with QMS and EMS certfications like ISO9001, ISO14001& ISO45001 will be submitted before executing the job)
(a) Digital VAF + PF Meters with RS 485, Cl 1 of voltage measurement range 50-520 VAC, including CT/PT site programable, flush mounting 96 x 96 mm - 01 No (b) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
INCOMING: Air Circuit Breaker (ACB) 4 Pole draw out type 800 Amps, Breaking capacity 50 KA, LED display, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle all as directed. OUTGOING : (a) MCCB 4 Pole, Microprocessor Based 500A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (b) MCCB 4 Pole, Microprocessor Based 160A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (Make of MCCBs/ACBs:- Legrand/Siemens/Schneider /ABB/L&T)
M&L for Installation and testing of LT factory made outdoor cubical type panel board (manufactured from CPRI approved firm), overall dimension not less than 1.0m (L) X 0.5m (W) X 1.2m (H) fabricated with 3.15 mm thick CRCA sheet on mild steel angle iron 50x50x6mm frame, totally enclosed type dust & vermin proof double door, back and front side openable fixed with nut & bolts with hinged shutter and locking arrangement for individual MCCBs, powder coated finished both internally and externally, suitable for 3 phase 4 wire system 415 volts grade, having aluminum busbar chamber of 1200 Amps wrapped with PVC sleeves with colour code and provision of making holes, cable connections with copper nut, bolts & washers including hydrograpic insulators with nuts & bolts at both ends including complete internal wiring with 10 sqmm PVC insulated copper wire (FRLS) and provision of PCC 1:3:6 type C-2 foundation platform of suitable size (30 cm above ground level), with provision for fixing MCCBs necessary inter connections with alluminium strips of size 25 x 5mm duly wrapped with coloured insulating tape/sleeves and providing under mentioned equipments & accessories including connections of all out going/in coming existing/new cables of size 35 Sqmm to 400 Sqmm by drawing /digging out cable from loops in trenches out side the Bldgs inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, and taking out of old skelton type panel with control switches/all accessories complete, complete all as specified and as directed. (NOTE:-LT Panel board shall be as per IS/IEC 61439-Part I & II, Test certificates Panel Builder/ with QMS and EMS certfications like ISO9001, ISO14001& ISO45001 will be submitted before executing the job)
(a) Digital VAF + PF Meters with RS 485, Cl 1 of voltage measurement range 50-520 VAC, including CT/PT site programable, flush mounting 96 x 96 mm - 01 No (b) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
INCOMING: Air Circuit Breaker (ACB) 4 Pole draw out type 800 Amps, Breaking capacity 50 KA, LED display, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle all as directed. OUTGOING : (a) MCCB 4 Pole, Microprocessor Based 400A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (b) MCCB 4 Pole, Microprocessor Based 315A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (Make of MCCBs/ACBs:- Legrand/Siemens/Schneider /ABB/L&T)
M&L for Installation and testing of LT factory made outdoor cubical type panel board (manufactured from CPRI approved firm), overall dimension not less than 1.0m (L) X 0.5m (W) X 1.2m (H) fabricated with 3.15 mm thick CRCA sheet on mild steel angle iron 50x50x6mm frame, totally enclosed type dust & vermin proof double door, back and front side openable fixed with nut & bolts with hinged shutter and locking arrangement for individual MCCBs, powder coated finished both internally and externally, suitable for 3 phase 4 wire system 415 volts grade, having aluminum busbar chamber of 1200 Amps wrapped with PVC sleeves with colour code and provision of making holes, cable connections with copper nut, bolts & washers including hydrograpic insulators with nuts & bolts at both ends including complete internal wiring with 10 sqmm PVC insulated copper wire (FRLS) and provision of PCC 1:3:6 type C-2 foundation platform of suitable size (30 cm above ground level), with provision for fixing MCCBs necessary inter connections with alluminium strips of size 25 x 5mm duly wrapped with coloured insulating tape/sleeves and providing under mentioned equipments & accessories including connections of all out going/in coming existing/new cables of size 35 Sqmm to 400 Sqmm by drawing /digging out cable from loops in trenches out side the Bldgs inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, and taking out of old skelton type panel with control switches/all accessories complete, complete all as specified and as directed. (NOTE:-LT Panel board shall be as per IS/IEC 61439-Part I & II, Test certificates Panel Builder/ with QMS and EMS certfications like ISO9001, ISO14001& ISO45001 will be submitted before executing the job)
(a) Digital VAF + PF Meters with RS 485, Cl 1 of voltage measurement range 50-520 VAC, including CT/PT site programable, flush mounting 96 x 96 mm - 01 No (b) Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
INCOMING: Air Circuit Breaker (ACB) 4 Pole draw out type 800 Amps, Breaking capacity 50 KA, LED display, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle all as directed. OUTGOING: (a) MCCB 4 Pole, Microprocessor Based 500A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (b) MCCB 4 Pole, Microprocessor Based 200A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC & E/F protection conforming to IEC 60947/IS 13947/Pt.II/1993 (Latest version),Ics=100% Icu for short circuit breaking capacity, -01 Nos along with Spreader terminals and Rotary handle. (Make of MCCBs/ACBs:- Legrand/Siemens /Schneider/ABB/L&T)
M&L for shifting of Transformer of Capacity 100 KVA to 630 KVA from one location to another location or MES store yard as directed by Engineer-in-Charge including disconnecting all LT/HT/Earthing/Nut bolts etc connection and shifting to the place as directed including re-connection at new location without disturbing elctrical supply not more than 6 Hours all as directed.
M&L for PCC 1:2:4 type B2 using 20 mm graded stone aggregated as in coping using necessary form work complete all as specified & directed.
M&L for PCC 1:4:8 Type D2 using 40 mm graded aggregate in foundation including form work and finishing the exposed surface of concrete even and smooth complete all as specified & directed.
Dismantling of steel pole/stuts any type including necessary excavation and T&P required at site complete all as specified & directed.
Dismantling of cross arms Channels etc. including necessary T&P required at site complete all as specified & directed.
Dismantling of Insulator including necessary T&P required at site complete all as specified & directed.
Dismantling of Stay assy including necessary T&P required at site complete all as specified & directed.
Dismantling of ACSR Conductor including necessary T&P required at site complete all as specified & directed.
Dismantling of Air break Switch including necessary T&P required at site complete all as specified & directed.
Dismantling of OCBs/VCBs including necessary T&P required at site complete all as specified & directed. (Note:- Resuffling of existing energy meters, relay, Data logger and connected wiring to be carried out from 11/33 KV Roorkee Road to RTO Sub Station VCBs while dismantling)
Supply installation, commissioning and testing of cable fault locating instruments suitable to locate the pin in LT/HT cable 1100 V to 33 KV cable and route tracing instrumens to trace the route of burried cable includes the eqpt shall be suitable for tesinting and pin pointing condutor and insulation fault of low and high resitance, intermittent or flashing nature in PILC, PVC and XLPE Low tension & High tension, under groudn power cables up to 33 KV. The calbe testing and fault locating kit shall be consist of following equipents.
(a) Digital fault locator :- Pre location of faults in cables shall be carried out ussing various fault location method built in the eqpts with the help of highly sophisticated menu driven microprocessor based digital fault locator. The eqpt should have fully menu-guided. Display should be clour LCD, Operation up to 6 hrs in battery mode and supoorted with pulse Echo method and implse current method.
(b) Surge Generator :- The surge generator shall be capable of providing repetitive surges at voltage variable from zero to the voltage mentioned below with output of 1000J (optionally 2000J). An interlock to be provided which ensures that instrument can switched on, Only if the special calbe supplied has been connected to the output sockets. The unit should be provided with automatic discharge device. Tech data of surge generator :- Out put Voltage : 0-32 KV continously varriable. Surge capacity : 1000 J (Optional 2000J) with Internal mounted cpacitors. Timer : 10 pulses per min, 20 pulses per min for automatic surging. Features for DC pressure testign unit. Continuously adjustable ouput voltage, HV Zero interloc, S/C protection by internal current limitation, Voltage indication up to 32 KV, Discharge Device, Thermal over current switch off.
Filter unit : A suitable coupling unit to enable fualt location as per pulse echo method and inpulse current metnod should be provided. The unit should incoroporate discharge device so that high voltage leads are discharged after appx 3 sec, after switching off the main instrument, The activation of the grounding unit should be acknowledged audibly. The discharge device shoul be activated automatically in case of power breakdown or an interruption.
Pin pointing set : Cable Fault PIN Pointing set model AFR A/I (Analogue). The pin pointing set is to be used in conjuction with above surge generator and should be capable of pin pointing acoustic disturbances created by the dissipation of energy from surge generator at the fault. Seismic distrubances picked up should be indicated to the operator both audibly on the head phone and visually on a display meter. The unit should be able to measuresacoustic propagation time wherein time differnce between magnetic and coustic pulse can be measured and evaluated. Instrument offered should also incorporate a magnetic detector with separate amplifier. This should pick up and display caused by each current impluses. The receiver should be light weight with intergrated batteries. The unit should switch off autmatically in case of disconnection from ground microphone. The unit should be provided with suitable ground microphone which can filter out noises for accurate fault pin-pointing. Sheath fault location with two earth probes accoriding to the step voltage method should also be possible The eqpt should have follwoing features :- Method should also be possible. The eqpt should have follwoing features :- (i) Integrated loudspeaker (ii) Water resistang design (iii) Large illuminated LCD display (iv) Adjustable filter to optimise acoustic signal (v) Accurate route tracing (vi) Light weight (vii) Acoustic pin-pointing combined with propagation time easurement (viii) Route tracing (ix) Depth determination.
Technical Data Receivign frequency : 50 HZ - 10 kHZ, 815 Hz, 2 kHZ, 10 kHZ+ 2 adjustable frequencies 50 Hz - 10 kHZ Filter - Digital Passive reception - 50/60 Hz mains signal Amplification : 0-38 dB Propogation velcity range : 0 - 96ms Operating Temp - 20 Degree centigate ... + 55 degree centrigrate Protection - IP54 Power Supply - 4x1.5 v cel (IEC LR6) Battery life (Normal operation) - Over 50h
Cables All cables reqd for operation of cable testing system shall be mounted on drums with take out facility. The cable drum should be provided with screw terminal for protective earth connection with a monitoring swithch so that putting in to operation of the system is only possible when the protective earth lead is conected on the system side. The particulars of cable required are indicated below : Earthing Cable : 15M earthing cable 16 sq mm multistranded flexible copper with rubberised insulation to connect. Power Suppply of LV cable : 15m three core cable for conection of equipment to mains (max 16A) HV cable : 15m, co-axial HV cable to serve as conection between cable fault locator and the cable to be tested. The cross section of core and shed should be 6 sqmm. The lead should be suitable for and oprating voltage up to 70 KV DC. EPR insulation should be used, so that cable can remain flexible even in extreme cold condition. Contd..........
Mounting The eqpt should be moutned on zink coated suitable base frame wheels so that eqpt can be easily transported in a vehicle, and once inserted in a vehicle it can be locked safe for transport. Complete eqpt should be provided as a single system. Safety measure. The instrument should have a built in automatic discharge feature as per which a cable (installation) has to be safety discharge afer a high voltage set. An emergency button on surge generato shall be provided to disconnect all equipments. Equipments shall be discharge on supply failure or disconnection of the unit. Make : CSD Instruments, Megger, Techno, Telemetrics. Note : The contractor will train two persons which has to be nominated by GE/Engr-in-Charge about all functions of fault locator machine and one person should be deployed at their ends to attend any problems which occurs in machine, and the individual will be present. In office/site within days after intimation from office till six month after completion of work.
Note : Tenderers may note that amount of credit Rs 10137000.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
SAGGI ELECTRIC COMPANY
FRIZO INDIA PVT LTD
B D Raizada Projects Pvt Ltd
Sant Construction Co.
Phoenix Infra
M/S BHATIA BUILDERS AND CONTRACTORS
JAY BEE Industries
TRIVENI CONSTRUCTIONS
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid