Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹3.6 Cr+₹5.8 L (1.53%)Accepted-AOC | ₹3.6 Cr+₹5.8 L (1.53%) Quoted ₹3.9 Cr | L2 | Accepted-AOC Work Order issued against FOB |
| 2 | L1₹3.8 CrRejected-AOC VILL CHAPAGURI ROAD P O NORTH BONGAIGAON DIST BOGAIGAON ASSAM | ₹3.8 Cr | L1 | Rejected-AOC L2 |
| 3 | L3₹4.5 Cr+₹72.3 L (18.9%)Rejected-AOC WARD NO 6 KOKRAJHAR BAZAR ROAD P O DIST KOKRAJHAR BTC ASSAM | DHUBRI | ASSAM | 783331 | ₹4.5 Cr+₹72.3 L (18.9%) | L3 | Rejected-AOC L3 |
| 4 | L4₹4.7 Cr+₹87.9 L (23.0%)Rejected-AOC R N B ROAD KOKRAJHAR 783370 | KOKRAJHAR | ASSAM | 783370 | ₹4.7 Cr+₹87.9 L (23.0%) | L4 | Rejected-AOC L4 |
Tender Value
₹3.8 Cr
EMD Value
₹7.6 L
Closing Date
16 Oct 2021, 2:00 pmClosed
CE, PWD (Bldg), Assam, Chandmari, Ghy-3
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
Proposed construction of DC Bunglow of Kamrup (Rural) at Amingaon
2021_PWBNH_23087_1
SMC/44/2021/4 Dated Guwahati 20th September 2021
Open Tender
Civil Works - Building
Item Rate
730 days
Amingaon
Please refer Tender documents.
6 documents required · 6 mandatory
₹11,500
Assam State Road Board Maintenance (Road) Fund
₹7.6 L
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
17 Jan 2022
30 Sept 2021
16 Oct 2021
30 Sept 2021
16 Oct 2021
30 Sept 2021
6 Oct 2021
Amount
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified upto a depth of 2.00 m below the existing G.L. - In Ordinary Soil
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified upto a depth of 2.00 m below the existing G.L. - In hard/dense Soil
Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified. (a) Within Guwahati city only
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately) - In prop. 1:3:6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using mixture machine)
Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) Using mixture machine (A) In sub - structure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level - M20 grade concrete
(B) In Super-structure ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing - M20 grade concrete a) In Ground Floor
a) In First Floor
a) In second Floor
iii) Vertical and horizontal fins (thickness not more than 100mm) individually or forming box louvre and projected band - M20 grade concrete a) In Ground Floor
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. - Using 38mm thick plank
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: i) Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face a) In Ground Floor
b) In First Floor
b) In Second Floor
ii) Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties for depth not exceeding 1.0M. a) In Ground Floor
b) In First Floor
b) In Second Floor
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. a) In Ground Floor
b) In First Floor
b) In Second Floor
Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete - Brick on flat soling.
Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in sub-structure up to plinth level - In proportion 1:5.
112 mm thick 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) - In cement mortar in proportion 1:4 (1 cement:4 sand) a) In Ground Floor
b) In First Floor
b) In Second Floor
Stone masonary work in retaining wall, wing wall, abutment, foundation, steps, plinth etc. in cement mortar in prop 1:6 with levelling course of 1:6:12 with both faces hammer dressed including bonding, providing face stone, through stone and centering including racking of joints, curing and supplying and all carriage of stone as directed including payment of forest royalty and sales tax and carriage. (a) Random Rubble Masonry
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department).ii) Of size 600mmx600mm and above
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department).b) Of size 800mmx800mm and above
Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department).ii) Of size 300mmx450mm and above
Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department).iii) Of size 300mmx600mm and above
Providing 18mm thick Granite slab on vertical face of pedestal laid over 10 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as directed with approved quality of shade.
18 mm thick Marble stone slab flooring of sizes 1200x1200 including treads and risers of steps, skirting, laid over 20 mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels. (i) Dungri slab
Extra for Granite finish in marble slab / tiles at all levels.
10 mm thick Cement plaster in single coat for plastering on celling and soffits of stairs up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed - In cement mortar 1:3 a) In Ground Floor
b) In First Floor
b) In Second Floor
15 mm thick Cement plaster in single coat on rough side of single or half brick wall for plastering under Ceramic Tile / Vitrified Tile flooring up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed - - In cement mortar 1:4 a) In Ground Floor
b) In First Floor
b) In Second Floor
Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc.complete as directed by the department for all levels. (P.C.C. to be measured and paid for seperately).(a) 1.25mm thick sheet.(v) Size 165mm x 60mm (Double rebate)
Providing fitting and fixing SS (304 grade) railingmade of hollow tubes, channels, plates ets...... As per approval of Engineer in Charge
Providing, fitting and fixing M.S. grill of requiredpattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. ii) Ornamental Grill - Fixed to Brickwork/P.C.C/R.C.C.
Supplying and installing uPVC- Sliding Windows made out of Lead free green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including interlock profile, glazing bead, grooving bead, brush seal, aluminum sliding track, stainless steel rollers, sealing wedge block, Espag, int handle, pop up handle, keeper, drain cap, fisher screws, packing pieces with all necessary stainlessness screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of silicon sealant from inside / outside of Dowcorning / GE or equivalent. With 5mm clear glass.(a) 2 Track Sliding Window with Flyscreen using uPVC section of sizes 88mm x 50 mm x 2.4mm thick wall for frame with inbuilt flyscreen track, 37mm x 61mm x 2.4mm thick wall for glass sash, 25mm x 49mm x 2.4mm thick wall for flyscreen sash having 1.5mm thick reinforcement, Interlock: 43mm x 23mm (Glass Panel) (a) 2 Track Sliding Window with Flyscreen using uPVC section of sizes 88mm x 50 mm x 2.4mm thick wall for frame with inbuilt flyscreen track, 37mm x 61mm x 2.4mm thick wall for glass sash, 25mm x 49mm x 2.4mm thick wall for flyscreen sash having 1.5mm thick reinforcement, Interlock: 43mm x 23mm (Glass Panel) (WINSTA KOMMERLING/ FINESTA/ ENCRAFT)(i) 2-Panel with 5mm clear float glass(approx 200sqm) (WINSTA KOMMERLING/ FINESTA/ ENCRAFT).(ii) 4-Panel with 5mm clear float glass
(ii) 4-Panel with 5mm clear float glass
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. 12.5 mm thick
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) suspended ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 298mm c/c. Then 12.5mm thick square edge Fulltone/ Sundance/ Cratone/ Louvertone/ Textured. Gypboard panels of size 595mmx595mm (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 290mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, grill diffusers etc. cut out to be made with the frame of perimeter channel supported suitably and measured and paid separately as and where necessary). (Glass wool to be measured and paid separately). M/F Frame Work with Design Type Semi Perforated Gypboard (Sundance) Tiles (NRC value 0.20 with 50mm glass wool mat backing) 12.5mm thick.
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) - Thickness = 1.5 mm thick
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.
Finishing old/new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Dulux (ICI) paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper with ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter - Surfaces over 100mm in width or girth for General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (a). With ready mixed paint , Wood primer (pink)
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i).Surfaces over 100mm in width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level) - TMT-Corrosion Resistant Steel (Fe-500) reinforcement bar (TATA/SAIL) a) In Ground Floor
b) In First Floor
b) In Second Floor
Providing plinth protection 50mm thick to cement concrete 1 : 3 : 6 with coarse agg.of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished.
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. ii) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Pre construction anti - termite treatment in the back fill in immediate contact with the foundation structure after completion, column, wall etc. to a depth of 450mm and width 300mm (when required refill in 200mm thick layers) applying the emulsion @ 5 (five) litres per square meter towards the concrete and masonry walls so as to ensure earth in contact with the structure well treated - with chemical (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete - With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Providing polished tiles of approved quality, size, shape of specified thickness on pavers over a base of 100mm compacted sand gravel including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department).
Construction of Granular sub-base by providing close graded…………………. maboratory as directed by the deptt.) (a)Using Grading I material
Supply, Installation, Fixing of ABC stored Pressure Fire Extinguisher with built – In Pressure Gauge to know the Ready ness of the Extinguisher Squeeze Grip Handle as per IS:13849 with ISI mark. (10 kg capacity) BRAND : FIRESTOP / FIREND / FIRE SHIELD
(A) Supplying, mixing, laying and applying the following waterproofing systems over Raft slabs, Roof slabs, Terraces etc. including curing complete as specified and directed by the Department at all levels.: (i) 1mm thick single coat of Master Crete M-81 of Choksey Chemicals /Dr. Sealkit Sealcrete (Asian Chemicals)/ mixed with cement in the ratio 1:2 as a prime coat. (ii) 3mm thick Polymer modified mortar - Cement sand mortar (in prop 1:3) mixed with Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals) @ 15% by weight of cement. (iii) 1mm thick coat of Master Crete M-81 /Dr. Sealkit Sealcrete (Asian Chemicals) mixed with cement in the ratio 1:2 as final coat.
Providing, fitting and fixing factory made wooden panelled doors with panel inserts of 75mm to 50mm width and 12mm to 20mm thickness,joined together with continous tongue and groove joints glued together with Movicol or other approved adhesive leaving a vertical groove of 7.5mm to 15mm between the inserts,the edges of panel inserts being feather tongue into styles and rails including providing three pairs of oxidised M.S butt hinges (100mm x75 mm x3.55mm),300x12 mm Aluminium Tower bolts-2nos,150 mm Aluminium Door handle-2nos, 300x16mm- Aluminium Sliding Door bolts-2nos and Door stopper with rubber stopper-1nos with necessay screws and furnishing with moulded timber beading of size 25mmx15mm around the panels complete as per drawing .I) Using Electro Coloured Iron fittings.A) With Teak wood / Sissu wood.(ii). 35 mm thick.
Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. a) Decorative type face panel and block board core. (ii) 35 mm thick .
(iii) 30 mm thick .
Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ). a) Sliding door bolts i) 300mm x 16mm
ii) 250mm x 16mm
b) Tower bolts i) 300mm x 10mm
ii) 250mm x 10mm
c) Door handles iii) 150mm
e) Butt hinge i) 125mm x 50mm x 4mm
iii) 100mm x 50mm x 4mm
o) Mortice cylindrical type(Godrej make)-polished Brass
v) Door stopper with rubber stopper
Providing,fitting and fixing Door closer of various type UL listed and fire rated good quality depending on the door specification.Types like single speed,Double Speed,Heavy Duty etc are available and as directed & specified by the department. A) Godrej d) Sleek Door Closer( 215mm x 51mm x 45mm)
Supplying, fitting and fixing drapery rods along with all accessories in doors, windows and other openings complete as specified and directed by the departmentb at all levels. (A) MAC Drapery rod vii) Nature line
Supplying, fitting and fixing MAC blinds horizontal and vertical complete as specified and directed by the department at all levels. (B) Horizontal blinds iv) 25 mm printed blind
viii) 25 mm timber blind
Providing cast in-situ manually driven reinforced cement concrete piles of using required grade of cement concrete of required bore-diameter, bulb diameter, lengths and with reinforcement as per specifications and drawings. Reinforcement to be measured and paid seperately as per item no. 21.4.1 C) UNIFORM PILE (I) Concret garade M20 c) Pile Dia 350 mm i) Upto 10 M
f) Pile Dia 500 mm i) Upto 10 M
Above 10 M
Extra for boring specified diameter pile in high sub-soil water level requiring use of drilling mud and extra cement (ii) 350 mm dia
(v) 500 mm dia
Empty boring for specified diameter piles from ground level to cut-off level. c) Pile Dia 350 mm
f) Pile Dia 500 mm
REINFORCEMENT Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code, for reinforced cement concrete works in piles including straightening, cleaning, cutting and bending to proper shapes and length as per specifications and drawings. The rings should be welded with vertical reinforcements as per specified IS codes of practice. (Inclusive of lap length, hook, chair, bend, anchor...etc) (A) TMT bar made of Primary producer (From Primary producer)
Routine test for test loading to 1.5 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. (Rate for Safe working Load)
Initial test for test loading to 2 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. (Rate for Safe working Load)
integrity testing of pile using low strain/sonic integrity test /sonic echo test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust and cheaping lean concrete lumps etc and use of computerised equpment and high skilled trained personal for conducting the test and submission of results ,all complete as per direction of engineer in charge.
Cutting of floating peat, water born vagitaion including carriage of cut peat by dragging or by boat carriage to the shore and stacking the cut peat at shore and disposal of the styacked material up to a distance of 9.50 km by mechanical means including loading and unloading
Providing fitting and fixing white vitreous EWC( without pedestal) P Trap water closet (European type W.C pan 400mm high) of Parryware make with seat and lid ,CP brass hinges and rubber buffers ,as directed and specified.
Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) A) Parryware make a) White (ii) Combination Closet S Trap (Cat No.C0205) (inclusive of seat cover)
Providing fitting and fixing Vitreous china wall hang water closet (European type W.C pan 400mm high) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) a) Parryware make (i) Pal Walvit Pan (inclusive of seat cover and fittings) (white/coloured) (Cat. No. C844K)
Supplying, fiting and fixing concealed cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) A) Parryware make (i) Rios with Chorme Push Plate (Cat no.8174/ Cat. No.C813726)
Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. (i) New Magnum (Cat. No.C0575)
Supplying, fiting and fixing automatic flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately)Auto Cister 10 litre (Cat. No.C61002)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately).(v) Cascade NXT 550 x 440 with short Pedestal and spring set (Cat. No.C0404/C0379/C8298)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) PEDESTAL BASIN (with pedestal) (A) Parryware Make (a) White (i) Duke 660 x 495 (Cat. No.C8416/27) (white/coloured)
Providing fitting and fixing Decorative Mirror complete as directed and specified.
Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified.(i) Jaquar Make(a) Continental (Cat.No.ACN-1331N)
Providing fitting and fixing Glass Shelf complete as directed and specified. Glass shelf with C.P. guard rail (i) Agmeco make (a) Cubin (Cat. No.CB-00104)
Providing, fitting and fixing CP towel rail complete as directed and specified. (a) Jaquar make (i) Continental 300mm for wash basin (Cat.No. ACN-1101N)
(vi) Kubix- Grab bar (300mm long) (Cat.No.AKB-35701)
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. i) 110mm dia.
ii) 75mm dia.
b) Concealed by chiselling or breaking brick wall/C.C/R.C.C. and making good to the damages. i) 110mm dia.
ii) 75mm dia.
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc.as necessary complete at all levels including below G.L. as directed and specified. i) In exposed surfaces or in trenches - 110mm dia
ii) In exposed surfaces or in trenches - 75mm dia
Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. i) In exposed surfaces or in trenches - 110mm dia
ii) In exposed surfaces or in trenches - 75mm dia
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. i) In exposed surfaces or in trenches - 110mm dia
ii) In exposed surfaces or in trenches - 75mm dia
Supplying fiting and fixing PVC single ‘Y’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. i) In exposed surfaces or in trenches - 110mm dia
ii) In exposed surfaces or in trenches - 75mm dia
Supplying fiting and fixing PVC cross ‘T’ plain of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. i) In exposed surfaces or in trenches - 110mm x 110mm
ii) In exposed surfaces or in trenches - 75mm x 75mm
Providing fitting and fixing 75mm dia. PVC cowel of ISI make complete as directed and specified.
Providing fiting & fixing C.P.Grating to the floors complete as directed and specified 100mm dia i) 75mm dia
ii) 100mm dia
Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) b) 40 mm dia
c) 32 mm dia
e)20 mm dia
f)15 mm dia
(B) Concealed pipe with cutting chases & making good the walls f)15 mm dia
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) - Jaquare make - Continental /Clarion - 2-Way bib cock
Crabtree Frattini brand ( For V.I.P. use) (C.P.) (a)Maestro (half turn / full tern) ii) C.P. Bibcock long body with flange Cat. No.7014
ii) C.P. 2-way bibcock double handle with flange Cat No.21017
Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) Jaquar (a) Continental / Clarion (i)15mm dia Male / Female (long thread)
(b) Queen's collection/ The Stealth Ranger (For VIP use. Prior approval of Chief Engineer PWD (Bldg) must be taken before use) (i) Angular stop cock with wall flange
Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed - Jaguar make - Continental Pillar cock (ISI) / Pillar cock
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes i) 2000 Lt capacity - Sintex make
Labour for erecting and placing PCVCTank over the stagging of 5.00m up to 8.00m complete as directed. a) 2000 litre capacity
Supplying fitting and fixing Chrome Plated (C.P.) shower 15mm dia. Of approved brand as directed and specified. (Pipes will be measured and paid separately) Jaquar make a) Continental (iii) Pressure adjustable shower with revolving joint
c) Stealth Rangers (i) Overhead rose shower with revolving joint & 150mm long shower arm with wall flange
Supplying, fitting and fixing Chrome Plated (C.P.) basin mixer complete as directed. Crabtree Frattini make (For VIP use. Prior approval of Chief Engineer PWD (Bldg) must be taken before use) a) Florence i)Central hole basin mixer without pop-up Cat No.21051 for wash basin
Supplying, fitting and fixing Chrome Plated (C.P.) wall mixer complete as directed. Jaquar make a) Continental/ Clarion i) Wall mixer non telephonic Cat No.217 for wash basin
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. b) 40 mm dia.
c) 25 mm dia.
Supplying and fitting ball valve as specified and directed.. b) 20mm dia. (gun metal/Copper)
Supplying fitting and fixing gun metal check valve including necessary threads to pipes. b) 40 mm dia (Heavy type)
Supplying fitting and fixing G.I. Foot valve with strainer including cutting necessary threads to pipes. b) 40 mm dia (Heavy type)
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
Providing fitting and fixing (600x600)mm 90mm thick C.I. Man hole cover and frame of 25 Kg. weight complete as directed and specified
Labour for test boring with 40mm (internal) dia G.I. Pipes including keeping surplus of earth and every 2.00m after first 3.00m depth and delivering the same in nearest P.W.D. camp in the small tin container (container, scaffolding, tools etc. will have to be arranged by the contractor at his own cost).
Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. vi) Bore hole of 200mm diameter
Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. PVC PIPE SUPREME /PRINCE / FUSION /SFMC Brand viii) 200mm diameter
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. B) PVC PIPE SUPREME / PRINCE / FUSION /SFMC Brand iv) 50mm diameter
Supplying fitting and fixing ISI approved PVC filter 3.00 metre long. ii) 50mm diameter
Supplying fitting and fixing check valve (non return valve) including thread to pipes. iii) 40mm diameter
Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained
Flushing, clearing, washing and watering of the tube well
Wiring for light/ fan/ call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in recessed conduit wiring system with 2 mm thick 20mm dia rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) complete SP upto 3.00 metre length.
MP upto 6.00 metre length.
LP upto 10.00 metre length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in recessed 2 mm thick rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete. SP upto 3.00 metre length.
MP upto 6.00 metre length.
LP upto 10.00 metre length.
Wiring for 5 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 2 mm thick 20 mm. dia. rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) SP upto 3.00 metre length.
MP upto 6.00 metre length.
LP upto 10.00 metre length.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 3 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 6/10/13 Amps INTERNATIONAL SOCKET , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. 3 module
6 module
12 module
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. 3 module
6 module
12 module
Supplying with fitting fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying and fixing of polished Brass Bracket of 18 S.W.G, 25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lamp
Supplying, installation, testing and Commission of the following indoor Decorative Recess mounted LED down lighter luminaries of model no-DN 394B LED 16 S -6500 PSU WH / MV1857RLOO / MV1840RLOO /MV1830RLOO / MV1830RLOO / MV1857R500 / MV1857R500 / MV1840RLOO / CRDL11R023HP57 complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Philips / LT / Wipro make).
Supplying,installation,testing and Commission of the following indoor surface Mounted LED Luminaires complete with all accessories such as driver etc. and necessary connection with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department Philips lighting luminaire 10 W EnduraLED Bulkhead Model WT 202W LED 6S PSU S1 PC or equivalent as approved by the Deptt.
Supplying fitting & fixing of LED Kubik Batten tube light fitting 300mm length as required and as directed by the department ( Jaquar or eqvt. make). kubik Series Batten tube fitting 10W
Supplying, fitting fixing of LED Batten Tubes high quality aluminium extruded with decorative end caps connection with 1.5 Sq.mm 1 core PVC insulated round copper conductor as required and as directed by the department. BN 021C LED 20 S PSU CW GR S2
Supplying fitting & fixing of LED Bulb non-dimmable in the existing batten / angle holder as required and as directed by the department ( Jaquar or eqvt. make). Prima Series Bulb 12W
Installation of earth station with 40mm dia and 4.5 mtr. long GI pipe with necessary GI reducing socket 40mmx20mm size locking arrangement with hinged cover plate, funnel, GI nuts, thorough bolts etc.for putting pipe and refitting with necessary enclosure on the top etc. as required complete.
Extra for using salt 5Kg and charcoal 64 Kg. for pipe earth electrode as required.
Supplying and laying with 6 SWG GI earth wire at 0.50 mtr. below ground level or conductor earth electrode including soldering, excavation work and refitting etc.as required complete.
Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make) Energy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent make
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Power Flow 225 mm sweep (ORIENT make)
Supply installation, testing and commissioning of 5 star rating Carrier make inverter air conditioning machine 1.5 Ton capacity.
Supplying with fitting and fixing Voltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND / Vee-Dee / V GUARD / VERTEX/ INDO/ VENUS make) 4.0 KVA Automatic Input 90-280 V Out put 200-240 V
Supplying with fitting and fixing of Single Phase Modular Motor Starter switch of the following specification complete including making necessary connection as specified and directed by the deptt. Overload Relay Range 16 - 25 Amps in 3 Module
Supplying and fitting fixing of electric storage water heater [Geyser] of VENUS/RAMSON/RACOLD/V Guard/ HAIER or equivalent make) including necessary connection etc. as required complete and as directed by the Department. Vertical 15 Litre Capacity
G. MCB/MCBDB/RCCB ETC. Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 12 way SPN double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 4way TPN (4+12) double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (Schneider MG, legrand, Hager make) 6-32A
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4P RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 100/300mA sensitivity 4P RCCB (ABB, Schneider MG, legrand, Hager make) 40A
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 30mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make) 40A
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) Core - 3 & 1/2 A2XWY A2XFY 70.00 Sq.mm 3&1/2 Core U.G. cable in 50mm dia medium duty G.I. pipe
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager make) 63A
Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved by the Deptt. as specified and directed by the deptt. 25 KA 415V 50 Hz 3P MCCB (Schneider, legrand, Siemens make) 125A
Wiring for drawing sub-main line with 2x1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system, including connection as required complete as directed and specified by the Deptt. With 2 x 1.5 sq. mm. cable in flat 19 mm ISI marked casing 'n' capping system,
Supply, installation, testing & commissioning of 1 Loop Intelligent / Analogue Addressable Fire Alarm Panel Microprocessor based character display Network option built in Alarm, Trouble & supervisory relays LPCB listed. make : HONEYWELL, MORLEY IAS or equivalent as approved by the Deptt.)
Supply, Installation, Testing, Commission of Loop card for Addressable Panels make- MORLEY/FIRELITE/Apollo or equivalent as approved by the Deptt.)
Supply, installation, testing & commissioning of Network Card/RS 232 Communication Board etc complete.make- MORLEY/FIRELITE/Apollo or equivalent as approved by the Deptt.)
Supply, Installation, Testing, Commission of Addressable Semi Flush Mounting Resettable (NonBreaking Glass) MCP, Supplied with Special Reset Tool BRAND : MORLEY/FIRELITE/Apollo or equivalent as approved by the Deptt.)
Supply, Installation, Testing, Commission of Intelligent Addressable Optical Detector with Remote Indicator Output With Base BRAND : MORLEY/FIRELITE/Apollo or equivalent as approved by the Deptt.)
Supply, Installation, Testing, Commission of Addressable / Convectional Beam Detector with Reflector Brand : MORLEY/FIRELITE/Apollo or equivalent as approved by the Deptt.)
Supply, Installation, Testing, Commission of Addressable Wall Mounting Sounder / Hooter Cum Strobe Brand : MORLEY/FIRELITE/Apollo or equivalent as approved by the Deptt.)
Supply, Installation, Testing, Commission of Addressable Input / Ouput Module Brand : MORLEY/FIRELITE/Apollo or equivalent as approved by the Deptt.)
Supply, Installation, Testing, Commission of Addressable Loop Isolator Brand : MORLEY/FIRELITE/Apollo or equivalent as approved by the Deptt.)
Supply, Installation, Testing, Commission of Response Indicator
Supply, installation, testing & commissioning of intelligent plug in Thermal Detectors having features like integral communication, dual LED for 360° viewing angle, walk test with address display etc. UL / LPCB approved, :HONEYWELL or equivalent as approved by the Deptt.)
Supply, installation, testing & commissioning of Response Indicator to give visual indication of detection of smoke - RED colour LED for indication. make - Agni Suraksha, or equivalent as approved by the Deptt.)System Sensor.
Supply, installation, testing & commissioning of intelligent plug in Laser based Smoke Detectors. UL / LPCB approved, make : HONEYWELL, MORLEY IAS or equivalent as approved by the Deptt.)
Supplying, installation, testing and commissioning of the following capacity Copper wound out door type sub-station complete with transformer,HT/LT side fittings and all other following accessories as required complete including payment of ASEB's supervision charge, labour charge, cost of ASEB's materials like metering equipment, CT/PT set etc.(excluding payment of load security),arrangement of charging approval of sub-station from Chief Electrical inspectorate and consisting of the followings: 35.1.2) 63KVA,50Hz,11/.433KV oil filled transformer with off circuit tap change.
Installation of earth station with 40mm dia and 4.5 mtr. long GI pipe with necessary GI reducing socket 40mmx20mm size locking arrangement with hinged cover plate, funnel, GI nuts, thorough bolts etc.for putting pipe and refitting with necessary enclosure on the top etc. as required complete.
Extra for using salt 5Kg and charcoal 64 Kg. for pipe earth electrode as required.
Supplying and laying with 6 SWG GI earth wire at 0.50 mtr. below ground level or conductor earth electrode including soldering, excavation work and refitting etc.as required complete.
Supply and laying of following size PVC/XLP E insulated and PVC sheathed 11KV gd aluminium conductor LT armoured U.G. cable laid in air (10%of cable length) including exavation of cable trench upto depth of 75cm,refilling, protective brick covering, sand cushioning etc. complete handling of surplus spoil,debries etc. to the proper as specified and directed by the deptt. 6.00mm2 2core U.G.Cable.
Supply and laying of following size PVC/XLP E insulated and PVC sheathed 11KV gd aluminium conductor LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing and partially in air through GI pipe(Tata/Nezon make) with necessary bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the department 6.00mm2 2core U.G.Cable in 25mm dia GI pipe
Supplying including fitting and fixing of the following luminaries complete with all accessories and makig necessary connection with 2x2.5sqmm P.V.C insulated S.C copper conduor as required and as directed by the department. Post top lantern HPS3601xCDMTD 70W, Philips or equivalent make.
Supplying including installation of the octagonal pole which shall be designed to withstand the maximum wind speed of 169km/hr. The top loading i e, area and weight of the fixtures are to be considered to calculate maximum deflection of the pole and the same shall meet the requirement of BS:5649 Part VI 1982. The pole shaft shall have octagonal cross section and shall be continously tampered with single longitudinal welding.There shall not be any circumferential welding of the pole shaft.The welding of the pole shaft shall be done by submerged welding process. All octagonal pole shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 foundation bolts.The base plate shall be fillet welded to the pole shaft at two locations i,e from inside and outside. The welding shall be done as per process approved by third party inspection agency(BAJAJ/PHILIPS/VALMONT/PARUTHI ENGGR/NEZONE make) Pole type BOP or equivalent-7030 Height 7m. The material of the pole is as following: conforming to grade 5355JO, base plate:Fe 410 conforming to IS226/IS 2062,Foundation bolts 6.8Gr, as per IS 1367,pole section:The octagonal pole shall be hot deep galvanised as per IS 2629/IS2633/IS4759 standard with average coating thickness of 65 micron.The galvanising shall be done in single deeping. Door opening:The octagonal pole shall have door of approximate 500mm length at the elevation of 500mm from the base plate.The door schall be vandel resistant and shall be weather proof to ensure safety of inside connection as approved by the department.The door shall be flush with the exterior surface and shall have suitable locking arrangement.The pole shall be adequetely strengthened at the location of the door compansate for the loss in section. There shall also be suitable arrangement for the purpose of earthing, smart pack junction box with 6 MCB and terminals for mounting inside base compartmentof pole. Top dia:70mm, Bottom dia:130mm, sheet thickness 3mm, Base plate dimensions in mm(LxBxT) 220x220x12, foundation bolt bolt size(noxdia) 4x20,Pitch circle dia.(PC 205) Bolt Length 750, projected bolt length 100mm, Anchore plate thickness:4mm, pole foundation: The octagonal pole shall be bolted on a pre cast foundation with a set of 4 foundation bolts of greater rigidity. Foundation: The foundation shall be done with(Earth work:-2.04 work:2.04cm RCC:1:1.5:3 proportion 0.65cm, steel:22.43kg, shuttering:4.32 sqm.
Supplying and fixing of Jaquar or equivalent Philips/ Wipro LED street light fittings complete with all accessories including connection cable, as approved by the Deptt.s etc. as required. LED Street Light 70W
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 3&1/2core A2XFY 50.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 3&1/2core A2XWFY,A2XFY 50.00 Sq.mm 3&1/2 Core U.G. cable in 50mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
Supply incl. installation of submerssible type water suply motor pump-set with all accesso ries incl.panel board on C.C foudation of proportion 1:2:4 jamped with MS nuts and bolts wire rope submerssible cable without suction GI pipe incl.making necessary connection etc as required complete. 3 HP Three phase
Supplying including installation, testing and commissioning of Air/Water Cooled Diesel Generator set coupled to suitable alternator of 220/415 V, AC, 1/3-Phase 0.8 p.f.(la mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) Standard Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the Technical Specification.. as per manufacturer. (RANGE FROM 5 KVA TO 625 KVA) Kirloskar green/bliss, Leyland, Volvo Penta, Perkinson, Mahindra, Greaves, Escort engine and Kirloskar, Stamford, Leroy somer alternator. KVA- PHASE- Approx size- Approx Wt - COOLING 62.5 3 3980x1240x1680 1920 Kg A/C
Construction of 3 phase 11 KV Line on 8.5 m PSC Pole using AAA Raccoon conductor 7/3.81mm with T cross arm average span 70m.
Art E Mide Construction Private Limited
Bajrang Bhadani
Kamal Singh Dugar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .