Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical UTTAR PRADESH UP | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical GRAM PO DUDHI SONBHADRA U P | Admitted-Fee/PreQual/Technical |
| 5 | Admitted-Fee/PreQual/Technical AURAIYA | Admitted-Fee/PreQual/Technical |
Tender Value
Refer Docs
EMD Value
₹58,000
Closing Date
15 Jan 2026, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE K.C.P.D-4, DUDDHI
EE KANHAR CANAL PROJECT DIVISION 4, DUDDHI SONEBHADRA
Construction of field hostel at Dhanaura Sichayi Colony ,Duddhi Sonebhadra
2025_UPIDC_1102628_6
03/EE/2025-26
Open Tender
Civil Works
Item Rate
180 days
Duddhi Sonebhadra
Please refer Tender documents
2 documents required · 2 mandatory
₹944
₹58,000
6 Feb 2026
2 Jan 2026
16 Jan 2026
2 Jan 2026
15 Jan 2026
2 Jan 2026
Field hostel at Dhanaura Sichayi Colony ,Duddhi
Excavation of foundation in ordinary soil/sandy loam, clay or sand including lift upto 1.5 meter and lead upto 30 meter and including filling, watering, ramming of excavated earth into the trenches or upto the space and sides of the foundation trenches or into the plinth and removal and disposal of surplus earth as directed by Engineer-in-charge upto a distance of 30 meter from the foundation trenches.required for proper completion of work as per direction of engineer-in-charge.
Earth Work in Filling including ramming and dressing the surface to requird levels and slope and also including 1.5m lift and lead upto 1.00km including all labour T&P etc. required for proper completion of work as per direction of engineer-in-charge.
Laying C.C M-15 (1:2:4) in foundation with cement, coarre sand and 4.75 to 20 mm curshed hard stone gait including cost of all Material , labour, T&P etcrequired for proper completion of work as per direction of engineer-in-charge.
Brick work in 1:4 C.M. with sand and F.M. Not less than 2.00 including cost of allLabour T&P etc required for proper completion 0f work as directed by engineer in charge.
R.C.C. work with coarse sand and 2 Cm. gauge stone ballast in the proportion of 1:2:4 lintel/sunshade of doors and windows excluding supply of materials and reinforcement. required for proper completion of work as per direction of engineer-in-charge.
Laying R.C.C M-20 (1:1.5:3) with cement, coarre sand and 4.75 to 20 mm curshed hard stone grit in column and slab including cost of all Material , labour, T&P etcrequired for proper completion of work as per direction of engineer-in-charge.
carriege, cutting, binding ,bending and placing of reinforcement including cost of binding wire labour T&p etc. for proper completion of work. required for proper completion of work as per direction of engineer-in-charge.
Centering & Shuttering for R.C.C. work in slab of building work. required for proper completion of work as per direction of engineer-in-charge.
12mm thick cement plaster in singal coat on fair side of singal or half brick wall for interior plastering up to floor two level i/c internal rounded angles chamfers and /or rounded angle not excending 80mm in grith and finished even and smooth no extra for mixing any additive 1:4 as per S.I.no.584required for proper completion of work as per direction of engineer-in-charge.
25mm thick 1:2:4 plain cement concrete floor with cement, approved coarse sand and 20 mm graded approved stone grit.required for proper completion of work as per direction of engineer-in-charge.
Providing and fixing vitrifield tiles 9mm thick (Light) shade somany/ Kajaria /jonson/orient make, fixing fine sand 1:3 (1 Cement & 3 Sandrequired for proper completion of work as per direction of engineer-in-charge.
Finishing wall with water proofing cement paint of approved make such as super snowcem,durrocem,robiacem, guttucem supercem quality and of required shade on under coated wall surfaces (two coat) over one and i/c one coat white cement primer to give an even shade after thoroughly brushing the surface to powedered materials i/c curing and cost of materials .required for proper completion of work as per direction of engineer-in-charge.
distempring (two coat) with oil bound distemper of approved brand and manufacture & of required shade on undercorated wall surfaceto give an even shade over & i/c a priming coat with cement primerof approved brand & manufacture such as berger ,J&N ,shalimar, asian paints etc required for proper completion of work as per direction of engineer-in-charge.
Wring Point for light with 1 sq.mm. FR PVC insulated multistrand single core copper conductor cable in 2mm thick PVC conduit pipe concealed in the wall complete with 1.5 sq.mm. earth wire drawn inside the conduit & piano type switch, ceiling rose&5 pin socket on 3mm thick phenolic laminated backlite- sheet etc. complete in all respects.CH.XIII/1A required for proper completion of work as per direction of engineer-in-charge.
S/F of 32 mm thick flush door commercial quality conforming to IS 2202 part I (1983) i/c fixing of wooden cleats & stoppers and including fixing and adjustment of hinges, bolt lock, handle, springs, fitting etc. all comp required for proper completion of work as per direction of engineer-in-charge.
Wiring Point For Plug with 1.5 sq. mm. PVC insulated single aluminium conductor cable in heavy guage 2mm thick PVC Conduit Pipe concealed in the wall, complete with 1.5 sq.mm. PVC insulated aluminium conductor cable as earth wire drawn inside the conduit & piano type switch & 5 Pin Socket on 3mm thick phenolic laminated backlite- sheet etc. complete in all respects.CH.XIII/4 required for proper completion of work as per direction of engineer-in-charge.
S/F of 6/10/16/20/25/32 Amp. MCB (10 KA) CH.XIII/8 required for proper completion of work as per direction of engineer-in-charge.
S/F surface/flush mounting 8 way SPN distribution board without MCB complete in all respect and as directed at site. CH. XIII/12
S/F of 63 Amp. D.P. Isolator CH. XIII/9B
S/F of hexagonal fan box with hexagonal side of approx. 80mm. in length fabricated from 16 SWGMS sheet incorporting 10mm. dia M.S. round has duly bent for supporting fan hanger duly painted with red oxide and screw arrangement with wiring conduct laid in the R.C.C. roof before concreting along with supply of all material, labour T&P etc. for proper completion (Complete rate).CH. XIII/43
S/F of Power plug with 15A./250V. flush type switch and 3 pin 15A./250V. flush type socket in suitable M.S. box of 175 x 100 x 50 mm. size with Bakelite sheet cover 3mm thick fixed with brass machine screws and cum washer (complete rate).CH. XIII/42
supply of 9'' size exhaust fan
wiring for circuit / submain wiring along with earth wire with the following size of FRLS pvc insulated copper conductor single core cable core surface / recessed medium class pvc conduct as required 2x2.5 sq mm +1x2.5 sq mm earth wire
wiring for circuit / submain wiring along with earth wire with the following size of FRLS pvc insulated copper conductor single core cable core surface / recessed medium class pvc conduct as required 4x10sq mm +2x6 sq mm earth wire
Add for Invertor wiring in wiring point for Light / Fan / Plug with 1.5 mm Cu Wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A& 15/16 modular socket out let and 15/16 A modular switch, connections etc as per required
Supply and fixing of LED Tube light batten fitting suitable for up to 1x22 watt LED tube light on surface complete in all respect-CAT-AAA
Supply and Fixing of recess/Surface/Pendant mounting round 6 watt 8 watt LED down Lighter having powder Coated die cast aluminium housing with heat sink,diffuser/Reflector and driver Set complete in all respect CAT-AAA
Supply and fixing of led Street light fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 wattt conforming to id 66
supply, installation ,testing and commisioning of 1200 mm sweep ,BEE 5star rated , ceilling fan with brush less direct current (BLDC) Motar , class of insulation B , 3 Nos , blades , 30 cm long down rod , 2 nos canopies ,shacle kit safty rope , copper winding , power factore not less than 0.9 service value (cm/m/w) minimum 6.00 AIR deliver minimum 210 cum/min ,350 RPM (TOLERANCE AS PER IS:374-2019) THD less than 10 % remote or electronic regulator unit for speed control and all remainning accessories including saftey oin , nut bolts washers temperature rise =75 degree C(max ) insulation resistance more than 2 mega ohm suitable for 230v 50 hz single phase AC supply ,earthing etc. complete as required .
supply and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required .
Extra for fixing the labour /shutters complete with frame for exhaust fan of all sizes
Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :Parryware /Hindware /Seabird /Orient (Coral)or equivalent -W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 630x450 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required :- Range of two squatting plates with 5 litre P.V.C. automatic flushing cistern
Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. -Granite Stone of approved shade
Providing and fixing Stainless steel A lsl 304 ('18/B) kitchen sink as per lS:13983 with Cl brackets and stainless steel pug 40mm, including painting of fittings and brackets, cutting and making good the walls wherever rquiaed. Kitchen sink with drain board- 510x1040mm bowl depth 250mm
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.- flexible pipe-32mm dia -40mm dia
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.- 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
C.P. Brass towel ring (jaquer, essco,cera, hindware)
C.P. Shop dish (jaquer, essco,cera, hindware)
Providing and fixing unplasticised PVC connection pipe with brass unions- 45CM Length- 15 mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931- 15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.- 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931- 15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931:- 15 mm nominal bore
Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete-110 MM
Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion- 110 mm
Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.-Coupler 110 mm
Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion-Bend 87.5 110 mm
Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion-Shoe (plain) 110 mm
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.- Concealed work including cutting chases and making good the walls etc.-15mm dia nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.- Concealed work including cutting chases and making good the walls etc.-20mm dia nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.- Concealed work including cutting chases and making good the walls etc.-25mm dia nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. -Internal work-Exposed on wall- 25 MM nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. -Internal work-Exposed on wall- 32 MM nominal dia pipes
Providing and fixing gun metal gate valve with wheel of approved quality. 25 MM nominal Bore
Providing and fixing gun metal gate valve with wheel of approved quality-32 MM nominal Bore
Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].- Capcity in Per Liters
Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m.- All kinds of soil- Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm.
Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.- 200 mm dia
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design- 200 mm dia S.W. Pipes
Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design- 150 x 100 mm size P type- With Sewer bricks conforming to IS : 4885
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 Fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:- Inside dimensions 455x610 mm and 45 cm deep for pipe line with one or two inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 Fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:- Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :- With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Door with chaukhat
window with frame
stage.html
html • 0.03 MB
cancelled_1.pdf
pdf • 0.38 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.98 MB
DocL3.pdf
Tender Documents • 2.96 MB
BOQ_2035327.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .